PÕLEMISE LIIGID HOONEAUTOMAATIKASÜSTEEMID AAR Page 1 OSA VI-II AUTOMAATNE TULEKAHJUSIGNALIS ATSIOON ( ATS ) ÜLO KALA

Similar documents
HOONEAUTOMAATIKASÜSTEEMID AAR

TULEKAHJU TEATENUPP HOONEAUTOMAATIKASÜSTEEMID AAR ÜLO KALA. Page 1. OSA VI-III ATS kesk ja lisaseadmed GKS VKS AAR0130 ÜLO KALA

Conventional Fire Detection

Xenex Conventional Fire Detection & Alarm System

Basic Fire Alarm SystemTraining. Arman Alnasar

AP200 SERIES INTELLIGENT ALARM DEVICES

AP200 SERIES INTELLIGENT ALARM DEVICES

All the security you need in one housing

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

esserbus -PLus maximum security, minimum costs

ELECTRONIC SOUNDER STROBE Model : AVD-C407

IQ8Control C Fire Alarm Panel

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

IQ8Quad. The highlight of every fire detection scenario. Fire detection technology

5 Sounds and Indications

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

CORNELL Emergency Response Systems

HEAD OFFICE, SECURITY DEPARTMENT

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

2004 AUSTRALIAN STANDARDS UPDATE

Our Mission. About Us. To create awareness of the essentiality attached to a firefighting system, as an important requisite in everyday life and loss

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

XP95/Series 90 Test Set

IQ8Quad. The highlight of every fire detection scenario. Fire detection technology

"Pegaso" wireless alarm system

Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618

ICC CODE CORNER 2015 International Fire Code

Date Issued: December 14, 2017 Revision: 2.1

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

"Pegaso" wireless alarm system D.I.Y. wireless kit

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Emerald 3000 MK3 GJD010 Lighting Controller

Electrisaver User and Installation Instructions

Fibre Optic Basics FIA Summer Seminar 2014

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

SOUNDER BASES AND SOUNDER BEACON BASES

TrueAlarm ES Analog Sensing

Intellia Sounder Bases and Sounder Beacon Bases

The supplier and installer of the system should be approved by the local civil defence authority.

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

2200 and 2200L ALARM CONTROL SYSTEMS

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

VTG-32E Spatial Sounder 24Vdc EN54 part 3 approved

Conventional Audible Visual Range

Group A Carlos Castro, Courtnie Coleman, Lucas Plager, Patrick Schexnayder

Acoustic door holder fitting instructions

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

This document is a preview generated by EVS

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

The EN54 Part 2 and 4 Fire System

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Floor Warden Training

Analogue Detectors. Series 200 plus

PROGRAM THEUNISSEN TECHNICAL TRADING BV

Opal TM AV Devices. Data Sheet. Benefits

Consultant Specification AGILE Wireless Fire Detection System

X10 Mini, Midi & Maxi

EWM 1000 GENERAL SPECIFICATION

Fire Detection Systems Product Catalogue (Version )

The new detector from Rafiki

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

This document is a preview generated by EVS

Intelligent technology made simple

Flexit SPIRIT UNI 3 - UNI 4 UUS! Ventilatsiooni keskseadmed-ja kontrollaparatuur

Fire Safety Basics II: Detection & Warning Systems

This document is a preview generated by EVS

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

Fire Signalling. Signalling Solutions

Ex Products Highest level of safety under the most difficult conditions

Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations

POWER METER INSTRUCTION MANUAL

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

ACP10 & ACP50 Security Systems

FlexSQUARE Square shaped beacons

Opal TM AV Devices. Data Sheet. Benefits

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Condominium Security Management System

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

This document is a preview generated by EVS

Circuit Schematics Control Unit with Camera. Power Supply

INPUT / OUTPUT MINI MODULES

Phone: Fax: Web:

Industrial & Commercial Thermal BCU 580

The EN54 Part 2 & 4 Fire System

Quick Selection Guide Fire Systems LSN Periphery

INSTALLATION MANUAL SECURIT 802 CONTROL PANEL

ISO INTERNATIONAL STANDARD

UV - flame detector dual fuel burners for intermittent burner operations

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

PROGRAMMING PROCEDURES (Table 3)

St. Vincent s Health System Page 1 of 6

Transcription:

HOONEAUTOMAATIKASÜSTEEMID AAR0130 2010 OSA VI-II AUTOMAATNE TULEKAHJUSIGNALIS ATSIOON ( ATS ) ÜLO KALA 1 PÕLEMISE LIIGID PUU PÕLEMINE LAHTISE LEEGIGA 2 PUU PÜROLÜÜS Page 1

PÕLEMISPROTSESS PÕLEMINE ENERGEETILISED PÕLEMISPRODUKTID AINELISED PÕLEMISPRODUKTID SOOJUSÜLEKANNE SOOJUSKIIRGUS MITTELENDUVAD PRODUKTID LENDUVAD PRODUKTID UV LEEGIANDUR ÕHUVOOLUD ULTRAVIOLETT KIIRGUS TUHK VEEAUR, CO, CO2 OPTILINE SUITSUANDUR HELID NÄHTAV KIIRGUS NÄHTAV SUITS TEMPERATUURIANDUR TEMPERATUUR IR LEEGIANDUR INFRAPUNANE KIIRGUS VEDEL JÄÄK IONISATSIOON VÕI SININE SUITSUANDUR PÕLEMISGAASID JA AEROSOOLID 3 SUURSILMUS (BUS/LOOP) Edasine kaabeldus Silmus jääb täielikult töökorda anduri eemaldamisel) ALUS Optilised suitsuandurid Intelligentsed andurid O 2 T fire detector OTG detector (optical/thermo/gas) Temperatuuriandurid Fixed Rate-of-rise Kahekordne reserveeritus esserbus ja lühiseeraldi igas anduris 4 Page 2

SISEKASUTUSE PUNKTANDUR Smoke Detector Heat Detector Black ring LASER Barcode label LIGIKAUDU 95% ANDURIST 5 MODIFIKATSIOONID IQ8Quad (TEMPERATUURI, OPTILINE VÕI GAASIANDUR) IQ8Quad LISATUD VILKUR IQ8Quad HELISIGAAL VASTAVALT EN 54 IQ8Quad SÕNALI NE ETTEPROGRAMMEERITUD TEADE KUIDAS VÄLJUDA ALATES 2011 KA KAAMERA 6 Page 3

KUNI 4 KOMPONENTI KOOS Detector: High-tech SUITSUANDUR Integrated flasher: INTEGREERITUD VILKUR Integrated sounder: SIREEN VAST. EN 54 Integrated speech function: SÕNALISE ALARMI TEATED Tulemas on : SISSEEHITATUD KAAMERA CIF 5 FPS 7 INTEGREERITUD VILKURIGA Alarm Ootel 8 Page 4

Audible signals (Example) Demo Speech outputs Demo Signal component Tone 1 (GB) Tone 2 (GB) Tone 3 (GB) Signal component Phrase 6 Phrase 7 Phrase 8 Phrase 9 Description of signal FP 1063.1 Telecoms BS 5839 Pt1-Tone 1 Alternating signal tone, Fequency 800 / 970 Hz @ 2Hz FP 1063.1 Telecoms BS 5839 Pt1-Tone 2 Alternating signal tone, Frequency 800 / 970 Hz @ 1Hz FP 1063.1 Telecoms BS 5839 Pt1-Tone 3 Cyclic signal tone, Frequency 970 Hz @ 1Hz 0,5 s Description of signal This is a fire alarm. Please leave the building immediately by the nearest available exit. Attention please. This is an emergency. Please leave the building by the nearest available exit. An incident has been reported in the building. Please await further instructions. This is a test message. No action is required. Duration [s] 4,00 4,00 4,00 Duration [s] 5,27 5,82 4,37 3,18 9 Phrase 10 The emergency is now cancelled. We AAR0130 apologise ÜLO for any KALA inconvenience. 2010 4,46 2 JOON või LIINIANDURID IR KIIRANDUR (SAATJA) (VASTUVÕTJA) 100 M LINEAARNE TEMPERATUURIANDUR 10 Page 5

OPTILINE LIINIANDUR IR KIIRANDUR (SAATJA) (VASTUVÕTJA) 100 M 11 PEEGLIGA LIINIANDURID VASTUVÕTJA SAATJA REFLEKTORe hk PEEGEL VASTUVÕTJA SAATJA REFLEKTORe hk PEEGEL 12 Page 6

OPTILISTE LIINIANDURITE PAIGUTUS T max = 12 m T ma1 > 6% Mst Mst MAKSIMAALNE TÖÖKAUGUSKAUGUS 13 6 m OPTILISTE LIINIANDURITE PAIGUTUS T max = 12 m T ma1 < 6% Mst Mst MAKSIMAALNE TÖÖKAUGUSKAUGUS 14 6 m Page 7

LIINIANDURITE PARAMEETRID 15 16 Page 8

ANALOOG TEMPRATUURI LIINIANDUR NEG. TEMP. KOEF.MATERJAL VASKSOON KAABEL KAITSEKEST PVC 17 DIGITAALNE TEMPRATUURI LIINIANDUR 18 Page 9

TUNNELITE DIGITAALNE TEMPERATUURIANDUR 19 TEMPERATUURID TUNNELIPÕLENGUL 20 Page 10

FIIBEROPTILINE TEMPERATUURISENSOR 21 FIIBER SENSORI TÖÖPÕHIMÕTE 22 Page 11

RUUMIANDURID VIDEO SUITSUANDUR LEEGIANDUR 23 VIDEO SUITSUANDUR KAITSTUD ALA enkooder 24 Page 12

SUITS MÄRGATUD EELALARM SUITS LEEK MÄRGATUD 25 LEEGIANDURID UV LEEDIANDURID - LEEGI UV KIIRHUSELE IR LEEGIANDURID - KUUMUSE MUUTUSELE SOOVITATAV MONTAAZIKÕRGUS ON 2 X OBJEKTI KÕRGUS 26 Page 13

27 SÄDEMEANDURID 28 Page 14

SÄDEMEANDURIGA TULETÕKESTUSSÜSTEEM SÄDEMEL ANDURITE VAHEL RAKENDUB KIIRE SULGEMEHHANISM MIS ISOLEERIB OHTLIKU KANALI OSA 29 PROOVIVÕTU ANDURID 30 Page 15

RAKENDUSKIIRUS ALGSTAADIUM ILMA NÄHTAVA N SUITSUTA NÄHTAV SUITS LEEGI TEKE INTENS. KUUMUS STAGE 1 STAGE 2 STAGE 3 BEAM STAGE 4 SPRINKLER PHOTO FLAME SUITSU TIHEDUS ION 31 AEG PROOVIVÕTUSÜSTEEMI EHITUS PROOVIVÕTU TORU VESDA LaserPLUS 88 32 Page 16

OLULISELT VARASEM HOIATUS NÄHTAVAT SUITSU POLE NÄHTAV SUITS LEEK INTENSIIVNE KUUMUS STAGE 1 STAGE 2 STAGE 3 BEAM STAGE 4 SPRINKLER PHOTO FLAME SUITSU TIHEDUS ION 33 AEG EELHÄIRE I EELHÄIRE II TULI TUNDLIKKUS KUNI 10 000 X SUUREM KUI TAVALISEL SUITSUANDURIL PAIGALDUS RIPPLAELE KAPILLAARTORU PROOVIVÕTUTORU MINIATUURNE PROOVIVÕTU PUNKT RIPPLAGI PEIDETUD PROOVIVÕTU PUNKT 34 Page 17

ANDURITE VÕRDLUS 35 ALARMISEADMED ANDUR KOOS INTEGREERITUD VÄLKLAMBI,SIREENI,JA SÕNALISE ALARMIGA, ERALDI ALARMSEADE KOOS INTEGREERITUD VÄLKLAMBI,SIREENI,JA SÕNALISE ALARMIGA 36 Page 18

MINIMAALNE HELITUGEVUS EN 54-3, OSA 4.6.2 NURK 15 45 75 105 135 165 DIN TOON 81 db 89 db 94 db 94 db 89 db 81 db Madal toon 730 Hz 81 db 90 db 95 db 95 db 90 db 81 db Keskmine 830 Hz toon 80 db 85 db 90 db 90 db 85 db 80 db Kõrge toon 970 Hz 82 db 91 db 96 db 96 db 91 db 82 db 37 38 VÕIMALIKUD TOONID Tone No. Frequency / Tone type 1) 1. Signal tone 730Hz tone, 1 Hz intermittent 2. Signal tone 730Hz tone, 2 Hz intermittent 3. Signal tone 830Hz tone, 1 Hz intermittent 4. Signal tone 830Hz tone, 2 Hz intermittent 5 Signal tone 970Hz tone, 1 Hz intermittent 6. Signal tone 970Hz tone, 2 Hz intermittent 7. Signal tone Alternating tone 730/830 Hz, 1Hz impulse 8. Signal tone Alternating tone 730/830 Hz, 2 Hz impulse 9. Signal tone Alternating tone 970/830 Hz, 1Hz impulse 10. Signal tone Alternating tone 970/830 Hz, 2 Hz impulse 11. Signal tone Continuous tone 730 Hz 12. Signal tone Continuous tone 830 Hz 13. Signal tone Continuous tone 970 Hz 14. Signal tone Signal tone according to DIN 33404-3 Page 19

NÕUDED ALARMISEADMETELE EELNEVALT TULEB MÕÕTA MÜRATASET PAIGALDUSKOHAS. ALRMSEADME HELITUHEVUS PEAB OLEMA VÄHEMALT 65 db JA KKÕIGIS RUUMI PUNKTIDES PEAB HELITUGEVUS OLEMA VÄHEMALT10dB KÕRGEM TAUSTAST TULEB MÕÕTA KA ALARMSEADME HELITUGEVUST PAIGALDUSKOHAS ALARMSIGNAAL PEAB OLEMA SELGELT TAUSTAST ERISTATAV 39 HELIRÕHU MUUTUS EEMALDUMISEL 92dB 1m 72dB 10m ~ -20dB ALARMSEADME POOLT TEKITATAV HELIRÕHK ON ANTUD 1 M KAUGUSEL SEADMEST KAUGUSE SUURENEMISEL 2 KORDA VÄHENEB HELIRÕHK 6 db (freefield measurement). 40 Page 20