THF Series Industrial High Efficiency Filters

Similar documents
WFH Series. High Efficiency Filters

High efficiency compressed air filtration. Truly Innovative Compressed Air Purification. LF Series

CFH Series High Efficiency Filters

20 21,250 SCFM GLOBAL AIR TREATMENT. FIL Series

Compressed Air Filters

RHP & FHP Series. High Pressure Air Treatment Global Air Treatment

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

AirCel. AG Aluminum. SH Steel. Industrial Filter Housings

D-Series 2 D 3. ultra-high purity compressed air dryers. Flow Capacity: Nm 3 /hr ( scfm)

MODULAR HIGH CAPACITY REFRIGERATED AIR DRYERS. GMRN & GMRC Series

Energy Saving Refrigerated Compressed Air Dryers DES Series 90 to 675 scfm (153 to 1148 nm 3 /h)

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

High Efficiency Coalescers Parker Filtration 8000 Series

HEAT OF COMPRESSION DESICCANT AIR DRYERS. DHC Series

Compressed Air Filtration

DELTA FILTER. G 3/8 to G 2


HIGH INLET TEMPERATURE REFRIGERATED AIR DRYERS. GHRN Series

RDS SERIES REFRIGERATED COMPRESSED AIR DRYERS ENERGY SAVING REFRIGERATED COMPRESSED AIR DRYERS SCFM

SR Series Refrigerated Dryers SCFM

Regenerative Desiccant Dryers. KAD, KED, KBD and Hybritec Series

CMMD Series Membrane Air Dryer

Downstream Equipment. Intelligent Air Technology

Manual Desiccant Dryer Numbering System

Non-Cycling Refrigerated Air Dryers. HPRplus SERIES 100 to 3000 scfm (170 to 5097 nm 3 /h)

THERMAL MASS CYCLING REFRIGERATED AIR DRYERS. GTRC Series

QUINCY QPNC SERIES NON-CYCLING QUINCY QRHT SERIES HIGH TEMP

Heat of Compression Desiccant Air Dryers. NRG-LES SERIES scfm ( nm 3 /h)

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series

industry revolves around VMMD Series Membrane Air Dryer

NON-CYCLING REFRIGERATED AIR DRYERS. GSRN Series

Blower Purge Desiccant Compressed Air Dryers IBP SERIES 500-4,300 SCFM

Refrigerated Compressed Air Dryers

HEATLESS DESICCANT AIR DRYERS

Air Treatment Solutions. kaeser.com

CNC Series Refrigerated Air Dryer CFM

DESICCANT AIR DRYERS. BD + CD + CD series

HeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 75 2,400 SCFM. Independently Verified Performance ( scfm models)

MultiPlex INNOVATIVE COMPRESSED AIR SOLUTIONS LARGE CAPACITY TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS

Refrigerated Air Dryers

EXTERNALLY HEATED DESICCANT AIR DRYERS. GEHD Series

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

Making Compressed Air and Gas Work Better

Compressed Air Dryers

Filters & Centrifugal Separators

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Adsorption Dryers. AD 7 to 1300

ECO DRI CYCLING REFRIGERATED AIR DRYERS 100 TO 8000 CFM

UA Series Air Dryers. 10 Year Warranty Limited ( SCFM) Setting a new standard in Quality and Reliability WAS 360

EXTERNALLY HEATED BLOWER PURGE DESICCANT AIR DRYERS. GBPD Series

REFRIGERATED AIR DRYERS

UA Series Air Dryers. 10 Year Warranty Limited ( SCFM) Setting a new standard in Quality and Reliability WAS 360

The Next Generation PORTABLE COMPRESSED AIR TREATMENT SYSTEM

Series 57 WATER/OIL SEPARATORS

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

Compressed Air Specialists

HeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance ( scfm models)

V A C U U M A N D P R E S S U R E T E C H N O L O G Y

Dual Tower Heat Reactivated Desiccant Air Dryer

REFRIGERATED COMPRESSED AIR DRYERS TRUE-CYCLING TM OPERATION

New standard in compressed air treatment, providing Energy Savings up to 99%

Refrigerated Compressed Air Dryers

DESICCANT AIR DRYERS. BD + CD + CD series

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series

CLEARPOINT THE WINNING COMBINATION FOR CLEAN COMPRESSED AIR

DGH Series Global Air Treatment

Equipment Designed for Industrial Applications

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series

REFRIGERATED AIR DRYERS

F o r Te x t i l e I n d u s t r y

Chapter 9: The basics of air preparation

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

RNC Series SCFM Global Air Treatment

Clean, Dry Air System

Global Leader in Efficiently Treating Compressed Air EXCELLENCE IN DESIGN, MANUFACTURING AND SERVICE

RNC Series SCFM Global Air Treatment

Meeting Your Compressed Air Treatment Needs

DRYAIRE DESICCANT SYSTEM MODEL 6760

Flexible Solutions for Air Quality

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

SECTION AIR COMPRESSORS AND ACCESSORIES

Devair and Miscellaneous Table of Contents

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series

NC Series. Multi-ModuleSeries. Non-Cycling Refrigerated Compressed Air Dryers INNOVATIVE COMPRESSED AIR SOLUTIONS

Installation, Operation, and Maintenance Manual Balston Model 76-01, 76-02, 76-10, and Membrane Air Dryers

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series

SRV. Unmatched Energy Savings and Unrivaled Product Quality. DRYERS. Variable Operation Dryers SCFM

Downstream Equipments

GRF Series Non-Cycling Refrigeration Dryers ANDARD ELECTRONIC DRAIN STANDARD ELEC SS EXPANSION VALVE F PRESSURE DEWPOINT

LARGE CAPACITY, REFRIGERATED COMPRESSED AIR DRYERS WITH TRUE-CYCLING TM OPERATION AND REDUNDANT OPERATING SYSTEMS. MultiPlex.

SYNRAD Technical Bulletin # 0015d

Pressure Swing Desiccant Dryers

RN SERIES REFRIGERATED COMPRESSED AIR DRYERS NON-CYCLING REFRIGERATEDERATED COMPRESSED AIR DRYERS SCFM

Heat of Compression Desiccant Air Dryers. HOC SERIES scfm ( nm 3 /h)

Non-Cycling Refrigerated Air Dryers. HPRplus SERIES 100 to 3000 scfm (170 to 5097 nm 3 /h)

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

Leading Innovation in Compressed Air Treatment CTS SERIES ELIMINATOR II OIL WATER SEPARATORS

Transcription:

www.titusfilters.com TH Series Industrial High fficiency ilters

and Save energy dollars protect your air system The ompressed ir hallenge, a government/ industry sponsored energy savings awareness program, estimates that $1.5 billion dollars a year is spent in the US toward compressed air. Over 20% of this could be saved by better design and management of compressed air systems. xcessive filter pressure drop is a key target to achieve this goal. The Titus ompany s TH Industrial High fficiency ilters can save energy dollars because they have a lower pressure drop throughout the ilter lement life, when compared to competitive filters using older element technology. on t be fooled by calculated savings from competitive de-mister filter modules. They do not have the efficiency of the Titus element, so tiny particulates flow downstream to pneumatic equipment, causing the wear and damage that a filter should prevent. Your compressed air is contaminated! irborne water vapor and dust are drawn into your compressor intake. The compressor adds oil aerosols, vapors and wear metals. Piping can add rust and scale. Real ollars xample: With a 200 HP ir ompressor running 24 hours per day, at 93% motor efficiency, and an electrical cost of $0.10/kW-HR, the 3 psid lower average pressure drop of a TH filter would represent an annual saving of over $3,000! system that has three filters can save up to $9,000 per year. TH Technology with 3 psid lower average pressure drop over element life

Introducing high technology filter elements Unique push-fit, double o-ring seal ilter element-to-head chamfered connection for ease of installation and removal; push-fit design eliminates tie rods. Stainless steel perforated support core iberglass inner support Provides pre-filtration of larger particles. eep bed multi-wrap orosilicate glass microfiber Large flow passages reduce high pressure drop and allow for a high dirt holding capacity. Wrap tension prevents channeled air flow. iberglass outer support Stainless steel perforated support core Suitable for temperatures up to 250 /120 ompatible with synthetic and mineral lubricants. Low average pressure drop over life of element. Regular replacement suggested for best performance and energy cost savings. Push-it esign Polyester needle felt sleeve Provides a unique coalescing action to quickly drain oil and will not crush like competitive foam socks. Ultrasonically welded down length which will not decay with age. No foam socks Many other brands of filters include a foam sock that is vulnerable to lubricants, corrosives, heat, and decay. nd cap durable and non-corrosive glass filled nylon which is attached to the element with a multi-part urethane resin. The element is then held in place by internal ribs within the filter housing for positive sealing. Low operating cost RGULR ILTR LMNT RPLMNT SVS MONY. IT MINIMIZS PRSSUR ROP N NSURS PROTTION O YOUR OMPRSS IR SYSTM, PNUMTI QUIPMNT, N INISH PROUT.

21st century filtration ifferential pressure indicator Modular NPT connections Option to bolt multiple filters together with Hi-Nitrile O-ring connection for ease of installation, leak elimination and reduced space requirement. Heavy aluminum construction astings 100% leak-tested, 300 psi / 20 barg pressure and 250 /120 temperature ratings. nnular seal and captive O-ring etween head and bowl with threaded connection to prevent leaks. xternal ribs or easy bowl removal. Internal ribs Secure element in-place and form quiet air zone to prevent condensate re-entrainment. Large capacity condensate sump With allowance to install internal float drain. Hex head on bottom or easy bowl removal. Threaded bottom port xternal auto or manual drain. Only 4-7 / 100-175mm clearance for element removal RQUIR LRN OR LMNT RMOVL ON OMPTITIV ILTR PROUTS

eatures and benefits Performance monitoring asy indication of excessive pressure drop to reduce energy costs. ccessories Mounting rackets llows convenient wallmounting of single or multiple filters. Pop-up P indicators (standard on TH20/30) Nylon pop-up is compatible with synthetic oils and lubricants. elta-p gauge (standard on TH65 and above) P gauge face is not pressurized. Unique magnetic sensor survives high impact. P gauge can be remote or panel mounted. Remote contact P alarm (optional) ry contacts close at 6 psid / 400mbar to send a notification signal to a bell, light, or control panel. an be field installed. Modular head design Multiple filters can be bolted together with O-ring seal. Minimizes threaded connections - leak points. Simplifies installation. Saves space. Modular mounting kits available with high tensile strength cap screws with nuts and O-ring. Side port (65-16100 scfm) Side mounting of external auto drain for low clearance applications. an be used as a separate manual drain or as a vent line connection to an external demand drain mounted to bottom connection. Port Plates llows for easy change from standard port size to match larger pipe size and reduce pipe fittings. Prevents costly oversizing of filters to pipe size. onnecting Kits llows linking of multiple filters in air system. vailable for models 15-1500 SM. Ring Spanner llows for easy bowl removal. Manual rain Valves vailable for all models. ottom drain adapter plate (1000-1500 scfm) Releases drain adapter for ease of float drain maintenance. asy disconnect of external drain when element is changed.

Typical compressed air treatment systems R ilter grade selection R General purpose, coalescing and bulk contaminant removal; point-of-use. P Pre-filtration to refrigerated dryer; higher efficiency, coalescing; point-of-use. H High efficiency coalescing oil removal after refrigerated dryer; upstream of desiccant dryers. H Oil vapors/odor/taste removal downstream of filter. RP Reverse low P afterfilter to heatless desiccant dryer. RH RH Reverse low H ombination particulate/ vapor removal. Large flow SM and RN code filter vessels eatures and benefits Welded to SM VIII construction. side mounted differential pressure gauge is fitted as standard, this can be read clearly from either side. Same unique filtration media as in aluminum casting. Inlet/outlet tappings for P reading. 2 to 12 flanges, up to 16100 scfm. Maximum working pressure 235 psig /16 barg and maximum temperature 250 /120. Lifting lug. One element, common to all sizes. Stainless Steel tie rod connections. Stainless Steel distribution plate. Painted inside and out. Side drain port with dip tube for low clearance applications or for vent line to demand drains. bottom drain port is standard to ease installation of demand drains and balance pipes. ompressed air purity classes ISO 8573-1 The ISO 8573 group of International Standards is used for the classification of compressed air. It also provides the test methods and analytical techniques for each type of contaminant. The table below summarizes the maximum contaminant levels specified in ISO 8573 Part 1 (2010) for the various compressed air quality classes. ach compressed air classification can be achieved by installing a specific filter grade or a combination of filter grades, depending upon required performance. Purity lass Specification R P H General Purpose Point-of-Use Pre-filtration / oalescing High fficiency ctivated harcoal uplex Particle removal micron 5 1 0.01 0.01 0.01 Maximum carryover at 68 /20 ppm 5 0.1 0.01 0.003 0.003 Recommended temperature / 100 / 38 100 / 38 100 / 38 77 / 25 77 / 25 Maximum temperature / 250 / 120 250 / 120 250 / 120 250 / 120 250 / 120 Pressure drop - clean and dry psid / mbar 0.4 / 30 1.0 / 70 1.5 / 100 1 / 70 2 / 140 Pressure drop - oil saturated psid / mbar 1.0 / 70 2.0 / 140 3.0 / 210 (see note) 3.0 / 210 Pressure drop - change element psid / mbar 6.0 / 400 6.0 / 400 6.0 / 400 (see note) (see note) lement media 0.1μm < d 0.5μm borosilicate microfiber multi-wrap carbon impregnated paper Housing material high quality aluminum/sm high carbon steel Maximum working pressure psig / barg 300 /20 (230 / 16 with internal float drain) /SM code vessels 235 / 16 combined &H Note: ctivated charcoal filters must not operate in oil saturated conditions and will not remove certain types of gases including carbon monoxide and carbon dioxide. hange interval depends on application, please contact your distributor. orrection actors or maximum flow rate, multiply model flow rate shown in the top chart by the correction factor corresponding to the working pressure. See specifications for maximum pressure. Operating Pressure (psig) 10 20 30 40 50 60 70 80 90 100 110 125 150 175 200 225 250 275 300 orrection actor 0.32 0.45.055 0.64 0.71 0.78 0.84 0.90 0.95 1.00 1.05 1.12 1.22 1.32 1.41 1.49 1.57 1.65 1.72 Note: To reduce pressure drop by 50%, reduce flow rate by 30%. Particles Water Oil Maximum number of particles per cubic meter as a function of particle size, d a Vapor Liquid a Total Oil a 0.5μm < d 1.0μm 1.0μm < d 5.0μm Mass oncentration p mg/m³ Pressure ewpoint oncentration Liquid Water w g/m³ 0 s specified by the equipment user or supplier and more stringent than lass 1 Liquid, aerosol, vapor mg/m³ 1 20 000 400 10 - -70-0.01 2 400 000 6 000 100 - -40-0.1 3-90 000 1 000 - -20-1 4 - - 10 000 - +3-5 5 - - 100 000 - +7 - - 6 - - - 0 < p 5 +10 - - 7 - - - 5 < p 10 - w 0.5-8 - - - - - 0.5 < w 5-9 - - - - - 5 < w 10 - X - - - p > 10 - w > 10 >5

imensions 3 3 3 1.6 1.6 1.6 Model TH20* to TH30* Models TH15 to TH30 Models TH65* to TH650* Models TH1000* to TH1500* Models TH700* to TH16100* ual certified SM and RN coded vessels are standard. SM & RN code vessels luminum housings Model low Rate imensions (inches) NPT onnections Weight Replacement Number SM Nm3/h In/Out Side ottom** lbs lement model TH15 15 25 3.00 12.00 4.00 6.00 7.00 1/4 N/ 1/4 MPT 2.0 TH15*** TH30 30 51 3.00 12.00 4.00 6.00 7.00 3/8 N/ 1/4 MPT 2.0 TH30*** TH20* 20 34 3.00 7.5 4.00 1.50 N/ 1/4 N/ 1/4 MPT 1.5 TH20 [ * ] TH30* 30 51 3.00 7.50 4.00 1.50 N/ 3/8 N/ 1/4 MPT 1.5 TH30 [ * ] TH65* 65 110 4.50 10.50 6.00 1.50 1.25 1/2 1/4 1/4 MPT 4.5 TH65 [ * ] TH75* 75 128 4.50 10.50 6.00 1.50 1.25 3/4 1/4 1/4 MPT 4.5 TH75 [ * ] TH100* 100 170 4.50 14.00 6.00 1.50 1.25 1 1/4 1/4 MPT 5.5 TH100 [ * ] TH150* 150 255 4.50 14.00 6.00 1.50 1.25 1 1/4 1/4 MPT 5.5 TH150 [ * ] TH225* 225 382 5.75 19.00 6.50 2.00 1.50 1 1/2 1/2 1/4 12.0 TH225 [ * ] TH300* 300 510 5.75 19.00 6.50 2.00 1.50 1 1/2 1/2 1/4 12.0 TH300 [ * ] TH450* 450 765 5.75 19.00 6.50 2.00 1.50 2 1/2 1/4 12.0 TH450 [ * ] TH650* 650 1105 5.75 26.75 6.50 2.00 1.50 2 1/2 1/4 12.5 TH650 [ * ] TH1000* 1000 1700 9.00 27.50 7.00 2.50 1.50 3 1/2 1/2 32.0 TH1000 [ * ] TH1250* 1250 2125 9.00 32.50 7.00 2.50 1.50 3 1/2 1/2 33.5 TH1250 [ * ] TH1500* 1500 2550 9.00 38.50 7.00 2.50 1.50 3 1/2 1/2 35.5 TH1500 [ * ] TH700* 700 1190 12.50 5.56 32.00 46.60 37.60 2 flg 1/2 1/2 92 TH700 [ * ] (1 ea.) TH1400* 1400 2380 18.00 8.63 32.00 45.30 38.30 3 flg 1/2 1/2 215 TH700 [ * ] (2 ea.) TH2100* 2100 3570 18.00 10.80 32.00 48.20 38.40 4 flg 1/2 1/2 326 TH700 [ * ] (3 ea.) TH2800* 2800 4760 20.00 12.80 32.00 50.30 39.30 6 flg 1/2 1/2 439 TH700 [ * ] (4 ea.) TH3500* 3500 5950 20.00 12.80 32.00 50.30 39.30 6 flg 1/2 1/2 439 TH700 [ * ] (5 ea.) TH4200* 4200 7140 20.00 14.00 32.00 54.30 40.40 6 flg 1/2 1 536 TH700 [ * ] (6 ea.) TH5600* 5600 9520 24.00 16.00 32.00 55.10 40.60 8 flg 1/2 1 647 TH700 [ * ] (8 ea.) TH7000* 7000 11900 28.00 18.00 32.00 58.10 42.60 8 flg 1/2 1 778 TH700 [ * ] (10 ea.) TH8400* 8400 14280 28.00 18.00 32.00 58.10 42.60 10 flg 1/2 1 778 TH700 [ * ] (12 ea.) TH9800* 9800 16660 28.00 20.00 32.00 59.40 42.80 10 flg 1/2 1 936 TH700 [ * ] (14 ea.) TH11200* 11200 19040 33.00 24.00 32.00 61.00 43.20 10 flg 1/2 1 1214 TH700 [ * ] (16 ea.) TH12600* 12600 21420 33.00 24.00 32.00 61.00 43.20 10 flg 1/2 1 1214 TH700 [ * ] (18 ea.) TH16100 16100 27370 32.00 12 flg 1/2 1 TH700 [ * ] (23 ea.) * ill in element grade (R,P,,H,RP,RH) to appropriate model number. ** ottom drain, 1/8 NPT with mechanical float drain. ***Includes 1 ea. of &H grade element.

36 Mountain View Road Morgantown, P 19543 www.titusfilters.com P: 610-913-9100 : 610-913-9200