MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

Similar documents
GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

MK 45 A. Stainless Steel Design. Installation Instructions Steam Trap MK 45 A

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

BK 46. Installation Instructions Steam Trap BK 46

GESTRA Steam Systems ER 50-1, ER Installation Instructions Level electrode

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

SMK 22 SMK SMK SMK 22-82

TRG 5-6x. GESTRA Steam Systems. Installation Instructions

GESTRA Steam Systems NRGS 11-2, NRGS Installation Instructions Level Electrode Types

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

BK 45 BK 45-U BK 45-LT BK 46

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

NRG NRG NRG NRG

GESTRA. Program for Universal Connections. The Smart Solutions

Temperature Sensor TRG Original Installation Instructions English

Level Electrode NRG NRG Original Installation Instructions English

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

Level Electrode NRG Original Installation Instructions English

Conductivity Electrode LRG Original Installation Instructions English

Installation & Operating Instructions

GESTRA Steam Systems OR Installation Instructions Oil & Turbidity Detector OR 52-7

Steam Traps and Steam Trap Testing

Model: 1100 Float-Controlled Condensate Trap, PN 25

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Mechanical seals external, single or double, to DIN EN 12756

GESTRA. Steam Traps and Steam Trap Testing. For all applications

GESTRA Information A 1.5

GESTRA Information A 1.7

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

Operating and installation instructions

GESTRA. Product Overview. The optimum components for every application

GESTRA. Product Overview. The optimum components for every application

Inverted Bucket Steam Traps

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Product overview. the optimum components for every application

Friwa Compact. Operating instructions EN

GESTRA. Steam traps and monitoring equipment. The right choice in every case

GESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51

INSTALLATION, OPERATION

Installation, Operation and Maintenance Instructions Electric Flow Heater OM009

HKF 8180 Operating instructions

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

THERMODYNAMIC STEAM TRAP

GESTRA. GESTRA Steam Systems NRS For ONE Electrode. English. Installation Instructions Level Switch NRS 1-50

Series 1140 and 1141 Temperature Regulators

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

Water level controller and limiter

GESTRA. GESTRA Steam Systems TRS English. Installation & Operating Instructions Temperature Switch TRS 5-50

MFP14 Automatic pumps. for condensate and other industrial fluids

INSTALLATION, OPERATION

Mechanical Seal RG-4 stationary, double, liquid sealed

Installation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

Water Safety Shut-Off Valve HON 790. Product information. serving the gas industry worldwide

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

FLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25)

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

MFP14 Automatic pumps for condensate and other industrial fluids

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

GESTRA Valves for Pure and Sterile Steam Systems. Intelligent solutions for sensitive processes

Installation and Maintenance Manual

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

FT14 Ball Float Steam Trap (Screwed)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

INSTRUCTIONS CertoClav EL

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

Safety. Operating instructions Ionization pilot burners ZAI, ZMI, ZKIH DANGER. Contents WARNING CAUTION Edition 12.11

Instructions for Installation, Operation, Care and Maintenance

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

KESSEL Grease separator EasyClean free Standard, Direct - oval in NS 2, 4, 7, 10, 15, 20, 25, 30 for set-up in frost-free rooms

Instruction Manual. Pharma-line ESE02198-EN Original manual

Mikrotherm. Manual Radiator Valves With presetting

FSW300 Series Flow Switch

Operation of heat exchangers

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

13-1. Temperature Regulator

STEAM - WATER MIXERS ADCAMIX MX20

1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450

Bedienungsanleitung. Fass-, Behälter- und Containerpumpen. F dichtungslos. F ,98% Fassentleerung. F

Care and Maintenance

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

USER S MANUAL ATH WH220

Bulletin K. Type RSF. Size: 1/2" - 4" (13-100mm) Suitable For: Ammonia, R-22, R-134a, R-502 and Other Common Refrigerants

Transcription:

GESTRA Steam Systems MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2 Installation Instructions 810348-07 Steam Traps MK 45-1, MK 45-2, MK 45 A-1, MK 45 A-2

Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED (Pressure Equipment Directive)...4 ATEX (Atmosphère Explosible)...4 Explanatory Notes Scope of supply...5 Description...5 Function...5 Technical Data Corrosion resistance...6 Sizing...6 Name plate / Marking...6 Design Component parts MK 45-1, MK 45-2, MK 45 A-1, MK 45 A-2...7 Thermostatic capsule...8 Key...9 Installation MK 45-1, MK 45-2, MK 45 A-1, MK 45 A-2...10 Flanged traps...10 Socket-weld traps...10 Screwed-socket traps...10 Butt-weld traps...11 Attention...11 Heat treatment of welds...11 Tools...11 Commissioning MK 45-1, MK 45-2, MK 45 A-1, MK 45 A-2...11 Attention...11 2

Contents continued Operation Page MK 45-1, MK 45-2, MK 45 A-1, MK 45 A-2...12 Thermostatic capsule...12 Maintenance MK 45-1, MK 45-2, MK 45 A-1, MK 45 A-2...12 Check steam trap...12 Clean / exchange capsule and nozzle insert...12 Clean / exchange strainer...13 Tools...13 Torques...13 Spare Parts MK 45-1, MK 45-2, MK 45 A-1, MK 45 A-2...14 Spare parts list...14 Decommissioning Danger...15 Disposal...15

Important Notes Usage for the intended purpose Use steam traps MK 45-1, MK 45-2, MK 45 A-1 and MK 45 A-2 only for the discharge of condensed water or for air venting from steam spaces. Use this equipment only for the discharge of condensate from steam lines within the specified pressure and temperature ratings and check the corrosion resistance and chemical suitability for the application in question. Safety note The equipment must only be installed and commissioned by qualified staff. Maintenance and retrofitting must only be performed by adequately trained persons who have a recognised level of competence. Danger The steam trap is under pressure during operation. When loosening flanged connections, plugs or the regulator, hot water and/or steam may escape. This presents the risk of severe scalding. Installation and maintenance work should only be carried out when the system is depressurized (0 bar): isolate the trap from both upstream and downstream pressure. The trap becomes hot during operation. This presents the danger of severe burns to hands and arms. Installation and maintenance work should only be carried out when the system is cold (20 C). Sharp edges on internal parts present a danger of cuts to hands. Always wear industrial gloves when replacing the regulator or the strainer. Attention The name plate indicates the technical specification of the equipment. Do not commission or operate a steam trap without a name plate. PED (Pressure Equipment Directive) The equipment fulfills the requirements of the Pressure Equipment Directive PED 97/23/EC. For applications with fluids of group 2. According to section 3.3 the equipment is excluded from the scope of this directive and must therefore not be CE marked. ATEX (Atmosphère Explosible) The equipment does not have its own potential source of ignition and is therefore not subject to the ATEX Directive 94/9/EC. The equipment can be used in potentially explosive areas 0, 1, 2, 20, 21, 22 (1999/92/EC). The equipment is not Ex marked. 4

Explanatory Notes Scope of supply MK 45-1: 1 Steam trap MK 45-1 1 Installation manual MK 45-2: 1 Steam trap MK 45-2 1 Installation manual MK 45 A-1: 1 Steam trap MK 45 A-1 1 Installation manual MK 45 A-2 1 Steam trap MK 45 A-2 1 Installation manual Description Thermostatic steam trap with corrosion-resistant thermostatic capsule unaffected by waterhammer. Integral Y-type strainer and non-return valve. Asbestos-free cover gasket (graphite/crni). Installation in any position. The traps with standard capsule N discharge condensate with virtually no banking-up, the traps with special capsule U with an undercooling of approx. 30 K (degc). n MK 45-1 with tandem seat (double sealing) Particularly suitable for low condensate flowrates. Optionally either with standard capsule 5N1 or undercooling capsule 5U1. n MK 45-2 with single seat For larger condensate flowrates. Optionally either with standard capsule 5N2 or undercooling capsule 5U2. n MK 45 A-1 with tandem seat (double sealing) Particularly suitable for low condensate flowrates. Optionally either with standard capsule 5N1 or undercooling capsule 5U1. n MK 45 A-2 with single seat For larger condensate flowrates. Optionally either with standard capsule 5N2 or undercooling capsule 5U2. Function The MK 45... is a thermostatic steam trap with membrane regulator. The capsule is filled with a liquid which boils at a temperature a few degrees lower than water. As long as condensate flows through the steam trap the liquid in the capsule is completely condensed due to the low ambient temperature. The pressure inside the capsule is lower than the surrounding pressure (service pressure) and the membrane with the valve disc is pushed in the opening direction. As the condensate temperature approaches steam temperature, the liquid filling of the capsule starts to boil and evaporate. The pressure in the capsule rises and the membrane with the valve disc is moved in the closing direction. Automatic air-venting is provided both, during start-up and during normal operation. The correct functioning of the MK 45... is neither affected by fluctuations in the upstream pressure nor by back pressure.the MK 45... can also be used for thermal air venting. 5

Technical Data Corrosion resistance If the steam trap is used for the intended purpose, its safety is not impaired by corrosion. Sizing The trap body must not be subjected to pulsating loads. The dimensional allowances for corrosion and anti-corrosive additives reflect the latest state of technology. Name plate / Marking The pressure / temperature ratings are indicated on the trap body / the name plate. For more information see GESTRA data sheets and Technical Information. According to EN 19 the name plate and the valve body indicate the type and design: Name / logo of the manufacturer Type designation Pressure class PN or Class Material number Max. temperature Max. pressure Flow direction 1 Stamp on trap body, e. g. specifies the quarter and the year of production (Example: 1 st 08 quarter 2008). Type designation Nominal size Thermostatic capsule 5 N 1 U 5 U 1 Fig. 1 6

Design Component parts MK 45-1, MK 45-2, MK 45 A-1, MK 45 A-2 1 2 3 4 5 6 7 8 $ 9 0! Fig. 2 " 7

Design continued Thermostatic capsule Capsule for nozzle insert with tandem seat : 5N1, 5U1 Capsule intact Capsule defective 3.2 mm 2.6 mm Fig. 3 Fig. 4 Capsule for nozzle insert with single seat $: 5N2, 5U2 Capsule intact Capsule defective 4.4 mm 3.8 mm Fig. 5 Fig. 6 % & / Fig. 7 ( 8

Design continued Key 1 Hexagon-head screw M 10 x 25 2 Name plate 3 Cover 4 Spring 5 Thermostatic capsule 6 Nozzle insert with non-return valve action 7 Bush (interference-fitted, cannot be replaced) 8 Gasket 40 x 48 x 2 9 Body 0 Strainer! Plug gasket A 24 x 29 " Plug Capsule with nozzle insert for tandem seat $ Capsule with nozzle insert for flat seat % Code number of pressure rating 5 = Δp 22 bar 6 = Δp 32 bar & Code letter of opening temperature N = Standard, Δt appox. 10 K U = Undercooling, Δt approx. 30 K / Code number of capacity 1 = Low capacity 2 = High capacity ( Manufacturing code number 9

Installation MK 45-1, MK 45-2, MK 45 A-1, MK 45 A-2 The steam traps can be installed in any position (arrow must point towards direction of flow). In the case of horizontal installation, make sure that the cover is at the top. Flanged traps 1. Observe correct position of installation. 2. Observe direction of flow. The flow arrow is on the trap body. 3. Consider space required for opening trap. When the trap is installed a minimum space of 30 mm is required for removing cover 3. 4. Remove plastic plugs. They are only used as transit protection. 5. Clean seating surfaces of both flanges. 6. Install steam trap. Socket-weld traps 1. Observe correct position of installation. 2. Observe direction of flow. The flow arrow is on the trap body. 3. Consider space required for opening trap. When the trap is installed a minimum space of 30 mm is required for removing the cover 3. 4. Remove plastic plugs. They are only used as transit protection. 5. Remove thermostatic capsule as described under Maintenance. 6. Clean socket-weld ends. 7. Apply arc welding processes 111 and 141 in accordance with ISO 4063. Screwed-socket traps 1. Observe correct position of installation. 2. Observe direction of flow. The flow arrow is on the trap body. 3. Consider space required for opening trap. When the trap is installed a minimum space of 30 mm is required for removing the cover 3. 4. Remove plastic plugs. They are only used as transit protection. 5. Clean thread of screwed sockets. 6. Install steam trap. 10

Installation continued Butt-weld traps 1. Observe correct position of installation. 2. Observe direction of flow. The flow arrow is on the trap body. 3. Consider space required for opening trap. When the trap is installed a minimum space of 30 mm is required for removing the cover 3. 4. Remove plastic plugs. They are only used as transit protection. 5. Clean butt-weld ends. 6. Apply arc welding processes 111 and 141 in accordance with ISO 4063 or gas welding process 3 to ISO 4063. Attention Only qualified welders certified e. g. according to DIN EN 287 may weld the steam trap into pressurized lines. Heat treatment of welds A subsequent heat treatment of the welds is not required. Tools Spanner 16 mm A.F. to DIN 3113, form B Spanner 22 mm A.F. to DIN 3113, form B Commissioning MK 45-1, MK 45-2, MK 45 A-1, MK 45 A-2 Make sure that the flanged connections of the MK 45-1, MK 45-2, MK 45 A-1 or MK 45 A-2 are permanently bolted and tight. Attention The steam trap is under pressure at start-up and during the operation. The steam trap becomes hot during operation. This presents the risk of severe burns to hands and arms. Always wear industrial gloves when setting the regulator. Installation and maintenance work may only be carried out when the system is depressurised (zero bar). Make sure that the lines upstream and downstream of the trap are not under pressure! 11

Operation MK 45-1, MK 45-2, MK 45 A-1, MK 45 A-2 MK 45-1, MK 45-2, MK 45 A-1 or MK 45 A-2 can be serviced (see Maintenance). Thermostatic capsule The factory setting of the regulating membrane enables the regulator to be steam-tight when closed and to open just before the pressure-dependent boiling temperature is reached. Maintenance MK 45-1, MK 45-2, MK 45 A-1, MK 45 A-2 GESTRA steam trap MK 45-1, MK 45-2, MK 45 A-1 and MK 45 A-2 does not require any special maintenance. However, if used in new installations which have not been rinsed it may be necessary to check and clean the trap / the regulating capsule. Check steam trap You can check the steam trap MK 45-1, MK 45-2, MK 45 A-1 and MK 45 A-2 for steam loss during operation using the ultrasonic measuring unit VAPOPHONE or the test unit TRAPtest. We recommend that you apply the measuring probe tip at the lower part of the trap cover 3. Should you detect any loss of live steam clean the trap and/or replace the capsule. Clean / exchange capsule and nozzle insert 1. Observe note Danger on page 4. 2. Undo body screws 1. Remove cover 3 from the body 9. 3. Remove and clean capsule 5. Unscrew nozzle insert 6. 4. Replace capsule 5 in case of visible signs of wear or damage. 5. Clean body, internals and all gasket surfaces. 6. Apply heat-resistant lubricant to all threads and the seating surfaces of the nozzle insert and the cover (use for instance WINIX 2150). 7. Screw in nozzle insert 6 and tighten with a torque of 90 Nm. 8. Position capsule 5 onto the nozzle insert 6 and press evenly, such that the capsule snaps into place. 9. Replace gasket if there are visual signs of damage. Use the same cover. Always replace gasket when using a new cover or the cover of another steam trap. 10. Put cover 3 onto the body 9. Tighten hexagon-head screws 1 alternately and in several steps to a torque of 25 Nm. WINIX 2150 is a registered trademark of WINIX GmbH, Norderstedt 12

Maintenance continued Clean / exchange strainer 1. Observe note Danger on page 4. 2. Unscrew sealing plug " and remove strainer 0. 3. Clean strainer, sealing plug and gasket seats. 4. Exchange strainer and sealing in case of visible signs of wear or damage. 5. Exchange gasket 8 if damaged. 6. Apply heat-resistant lubricant to the thread of the sealing plug (use for instance WINIX 2150). 7. Install sealing plug " with gasket! and strainer 0. Tighten sealing plug with a torque of 120 Nm. Tools Spanner A.F. 16 mm to DIN 3113, form B Spanner A.F. 22 mm to DIN 3113, form B Spanner A.F. 30 mm to DIN 3113, form B Torque spanner 20 120 Nm to ISO 6789 Torques Item Designation Torque [Nm] 6 Nozzle insert 90 1 Body screws 25 " Sealing plug 120 All torques are based at 20 C room temperature. WINIX 2150 is a registered trademark of WINIX GmbH, Norderstedt 13

Spare Parts MK 45-1, MK 45-2, MK 45 A-1, MK 45 A-2 6 5 8 Fig. 8 0! " Spare parts list Item 8 $ 8 Designation Membrane regulator, complete 5N1 375 109 Membrane regulator, complete 5U1 375 111 Stock code MK 45-1 MK 45-2 MK 45A-1 MK 45A-2 Membrane regulator, complete 5N2 375 110 Membrane regulator, complete 5U2 375 112 0! " Strainer set, complete 5 Thermostatic capsule 5N1 376 165 1 ) Thermostatic capsule 5U1 376 166 1 ) 375 113 375 113 375 382 375 382 Thermostatic capsule 5N2 376 167 1 ) 5 Thermostatic capsule 5U2 376 168 1 ) 8 Cover gasket 2 ) 40 x 48 x 2, graphite 375 159 375 159! Plug gasket 2 ) A 24 x 29, stainless steel 375 162 375 162 1 ) Packaged 10 per box. Contact your local dealer for smaller quantities. 2 ) Minimum purchasing quantity 50 pcs. Contact your local dealer for smaller quantities. 14

Decommissioning Danger Risk of severe burns and scalds to the whole body! Before loosening flanged connections, stuffing box unions or sealing plugs, make sure that all connected lines are depressurized (zero bar) and cooled down to room temperature (20 C). Disposal Dismantle the equipment and separate the waste materials, using the specifications in the table Materials as a reference. For the disposal of the equipment observe the pertinent legal regulations concerning waste disposal. 15

GESTRA Agencies all over the world: www.gestra.de España GESTRA ESPAÑOLA S.A. Luis Cabrera, 86-88 E-28002 Madrid Tel. 00 34 91 / 5 15 20 32 Fax 00 34 91 / 4 13 67 47; 5 15 20 36 E-mail: aromero@flowserve.com Polska GESTRA Polonia Spolka z.o.o. Ul. Schuberta 104 PL - 80-172 Gdansk Tel. 00 48 58 / 3 06 10-02 od 10 Fax 00 48 58 / 3 06 33 00 E-mail: gestra@gestra.pl Great Britain Flowserve GB Limited Abex Road Newbury, Berkshire RG14 5EY Tel. 00 44 16 35 / 46 99 90 Fax 00 44 16 35 / 3 60 34 E-mail: gestraukinfo@flowserve.com Portugal Flowserve Portuguesa, Lda. Av. Dr. Antunes Guimarães, 1159 Porto 4100-082 Tel. 0 03 51 22 / 6 19 87 70 Fax 0 03 51 22 / 6 10 75 75 E-mail: jtavares@flowserve.com Italia Flowserve S.p.A. Flow Control Division Via Prealpi, 30 l-20032 Cormano (MI) Tel. 00 39 02 / 66 32 51 Fax 00 39 02 / 66 32 55 60 E-mail: infoitaly@flowserve.com USA Flowserve GESTRA U.S. 2341 Ampere Drive Louisville, KY 40299 Tel.: 00 15 02 / 267 2205 Fax: 00 15 02 / 266 5397 E-mail: dgoodwin@flowserve.com GESTRA AG P. O. Box 10 54 60, D-28054 Bremen Münchener Str. 77, D-28215 Bremen Telephone +49 (0) 421 35 03-0 Fax +49 (0) 421 35 03-393 E-Mail gestra.ag@flowserve.com Internet www.gestra.de 810348-07/108cm 2007 GESTRA AG Bremen Printed in Germany 16