NRG NRG NRG NRG

Similar documents
Level Electrode NRG Original Installation Instructions English

Level Electrode NRG NRG Original Installation Instructions English

Installation & Operating Instructions

Conductivity Electrode LRG Original Installation Instructions English

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

GESTRA Steam Systems ER 50-1, ER Installation Instructions Level electrode

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

SMK 22 SMK SMK SMK 22-82

Temperature Sensor TRG Original Installation Instructions English

GESTRA. GESTRA Steam Systems NRS For ONE Electrode. English. Installation Instructions Level Switch NRS 1-50

GESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51

GESTRA Steam Systems NRGS 11-2, NRGS Installation Instructions Level Electrode Types

BK 45 BK 45-U BK 45-LT BK 46

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

GESTRA Steam Systems NRS For TWO Electrodes. English. Installation Instructions Level Switch NRS 1-50

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

TRG 5-6x. GESTRA Steam Systems. Installation Instructions

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

GESTRA. GESTRA Steam Systems TRS English. Installation & Operating Instructions Temperature Switch TRS 5-50

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

MK 45 A. Stainless Steel Design. Installation Instructions Steam Trap MK 45 A

BK 46. Installation Instructions Steam Trap BK 46

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

GESTRA Steam Systems OR 52-5 OR English. Installation & Operating Instructions Oil & Turbidity Detector OR 52-5, OR 52-6

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Mechanical seals external, single or double, to DIN EN 12756

VERSAFLOW VORTEX Supplementary instructions

Model: 1100 Float-Controlled Condensate Trap, PN 25

1592P01. for liquids in piping DN

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

GESTRA. Program for Universal Connections. The Smart Solutions

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Flameproof Manual Call Points

GESTRA Steam Systems OR English. Installation Instructions Oil & Turbidity Detector OR 52-7

Water level controller and limiter

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Heat Exchanger Block Replacement Instructions

GESTRA. Product Overview. The optimum components for every application

Product overview. the optimum components for every application

OPTIBAR DP 7060 Supplementary Instructions

Installation manual plugs and connectors QUICK-CONNECT (63 A)

INSTRUCTION MANUAL (ATEX)

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

INSTRUCTION MANUAL (ATEX / IECEx)

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

COMPACT FLAME CONTROLLER CFC 2000

GESTRA. Product Overview. The optimum components for every application

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Centurion Guided Radar HAWK CGR SERIES

4) Intrinsic Safety Certification

standards: standards:

INSTALLATION INSTRUCTION

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

Fisher 2100 Pneumatic and 2100E Electric Liquid Level Switches

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

½ Monitored Pneumatic Valve Patented Technology

FSW300 Series Flow Switch

Installation and maintenance instructions

Installation, operating and servicing instructions

Mechanical Seal RG-4 stationary, double, liquid sealed

CORREX MP Anode with external voltage source. Installation & Operation Manual

PA ma Loop Powered Level Preamplifier

Monitored Pneumatic Valves On Series Ported Manifold

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Supplementary Installation and Operating Instructions. Category II2G

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

Installers Awareness Booklet. Please read before installation as this booklet contains important Information

INSTRUCTION & SERVICE MANUAL

Manual Power relay SR853

½ Monitored Pneumatic Valves On Series Ported Manifold

Survey of electrical equipment installed in hazardous areas on tankers

Design and manufacture of agitators since INSTALLATION MANUAL Start-up and maintenance. Top-entry agitators

Withdrawable module with vacuum circuit-breaker 3AE and installation accessories kv, ka kv, 40 ka 24 kv, ka

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

Operating Manual MS220KA and MSR220KA

COMPACT FLAME CONTROLLER CFC 1000

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

EXFG Oxygen Analyzer System. Installation Guide. EXFG Probe. ABB Process Analytics

IECEx Certificate of Conformity

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

PERFORMANCE SHOWER PRODUCTS

COMPACT FLAME CONTROLLER CFC 100

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

VIESMANN. Installation instructions VITOMAX 200-HW. for contractors

CalMag Filter Installation Instructions

PROTECT SRB 200EXi-1A

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

C Electrical Connection Kit

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Operating and installation instructions

optris Outdoor protective housing

Transcription:

GESTRA Steam Systems NRG 16-50 NRG 17-50 NRG 19-50 NRG 111-50 EN English Installation Instructions 818954-04 Level Electrodes NRG 16-50, NRG 17-50, NRG 19-50, NRG 111-50 1

Contents Important Notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards EC Pressure Equipment Directive 97/23/EC...5 Functional Safety acc. to IEC 61508...5 VdTÜV Bulletin "Wasserstand 100" (= Water Level 100)...5 ATEX (Atmosphère Explosible)...5 UL/cUL (CSA) Approval...5 Note on the Declaration of Conformity / Declaration by the Manufacturer...5 Technical data NRG 16-50, NRG 17-50, NRG 19-50...6 Scope of supply...7 Name plate/marking...8 Installation Dimensions NRG 16-50, NRG 17-50, NRG 19-50...9 Dimensions NRG 111-50...10 Tools...11 NRG 16-50, NRG 17-50, NRG 19-50, NRG 111-50...12 NRG 16-50, NRG 17-50, NRG 19-50, NRG 111-50, step 1...13 NRG 16-50, NRG 17-50, NRG 19-50, NRG 111-50, step 2...13 Key...13 NRG 16-50 F, NRG 17-50 F, NRG 19-50 F, NRG 111-50 F, with aluminium terminal box...14 NRG 16-50 F, NRG 17-50 F, NRG 19-50 F, additional information...15 Key...15 Examples of installation NRG 16-50, NRG 17-50, NRG 19-50...16 NRG 111-50...17 Key...17 2

Contents - continued - Electrical connection Page NRG 16-50, NRG 17-50, NRG 19-50, NRG 111-50, four-pole connector...18 Key...18 Connection of level electrode...19 NRG 16-50, NRG 17-50, NRG 19-50, NRG 111-50, with four-pole connector...19 NRG 16-50 F, NRG 17-50 F, NRG 19-50 F, NRG 111-50 F, with aluminium terminal box...19 Tools...19 Wiring diagram...20 Key...20 Commissioning, fault indication and troubleshooting...21 Removing and disposing of the level electrode Removing and disposing of level electrode NRG 1..-50...21 Removing and disposing of level electrode NRG 1..-50F...21 3

Important Notes Usage for the intended purpose The level electrodes NRG 1...-50 are used in conjunction with level switch NRS 1-50 as water level limiters for steam boilers and (pressurised) hot water installations. Water level limiters switch off the heating when the water level falls below the set minimum level (low water). Function When the water level falls below the low level, the level electrode is exposed and a low level alarm is triggered in the level switch NRS 1-50. This switchpoint "Low water level (LW)" is determined by the length of the electrode tip. The electrode operation is based on the conductive measuring principle using the electrical conductivity of the water for signalling water level. The self-monitoring function ensures that an alarm will also be triggered if the electrode insulation is contaminated or has developed a leak or if there is a malfunction in the electrical connection. The level electrode is installed inside steam boilers, vessels or inlet lines of hot-water systems. The protective tube mounted on site (see section Examples of Installation - pages 16, 17) ensures correct functioning. One level electrode NRG 1...-50 can be installed together with one GESTRA level electrode, one level switch or transmitter for water level control and high level alarm in one single protection tube or level pot. If the level electrode is installed in an isolatable level pot outside the boiler, make sure that the connecting lines are rinsed regularly. In addition, the logic unit SRL is required to monitor the purging times and the purging sequence. If the connecting lines for steam 40 mm and water 100mm, the installation is considered to be internal. In this case the rinsing processes do not have to be monitored. Safety note Water level limiters are safety accessories as defined in the Pressure Equipment Directive (PED) and must only be installed, wired and commissioned by qualified and competent staff. Retrofitting and maintenance work must only be performed by qualified staff who - through adequate training - have achieved a recognised level of competence. Danger When loosening the electrode steam or hot water might escape! This presents the risk of severe scalding all over the body! It is therefore essential not to dismantle the electrode unless the boiler pressure is verified to be 0 bar. The electrode becomes hot during operation. Risk of severe burns to hands and arms. Before carrying out installation and maintenance work make sure that the steam trap is cold. Attention The name plate specifies the technical features of the equipment. Do not commission or operate any item of equipment that does not bear its specific name plate. 4

Directives and standards EC Pressure Equipment Directive 97/23/EC Water level limiters are safety accessories as defined in the Pressure Equipment Directive (PED). The level electrode NRG 1...-50 in conjunction with level switch NRS 1-50 is EC type approved according to EN 12952/EN 12953. These Directives state, among other things, the requirements made on limiting systems and equipment for steam boiler plants and (pressurised) hot-water installations. Functional Safety acc. to IEC 61508 The level electrodes NRG 1...-50 / NRG 16-36 are certified acc. to IEC 61508 only if used in combination with level switch NRS 1-50. This standard describes the functional safety of safetyrelated electrical/electronic/programmable electronic systems. The equipment combination NRG 1...-50 or NRG 16-36 + NRS 1-50 corresponds to a type B subsystem with Safety Integrity Level (SIL) 3. VdTÜV Bulletin "Wasserstand 100" (= Water Level 100) The level electrodes NRG 1-50, NRG 1...-11 and NRG 16-36 in conjunction with the level switch NRS 1-50 are type approved according to the VdTÜV Bulletin "Water Level 100". The VdTÜV Bulletin "Wasserstand (= Water Level) 100" specifies the requirements made on water level control and limiting equipment for boilers. ATEX (Atmosphère Explosible) The level electrodes NRG 1...-50, NRG 1...-11 and NRG 16-36 are simple items of electrical equipment as specified in EN 60079-11 section 5.7. According to the European Directive 94/9/EC the equipment must be equipped with approved Zener barriers if used in potentially explosive areas. Applicable in Ex zones 1, 2 (1999/92/EC). The equipment does not bear an Ex marking. The suitability of the Zener barriers is certified in a separate document. Note that the requirements of the IEC 61508 are not met if the NRG 1...-50, NRG 1...-11, NRG 16-36 + Zener barriers + NRS 1-50 are interconnected! UL/cUL (CSA) Approval The equipment meets the requirements of Directives: UL 508 and CSA C22.2 No. 14-13, Standards for Industrial Control Equipment. File E243189. Note on the Declaration of Conformity / Declaration by the Manufacturer For details on the conformity of our equipment according to the European Directives see our Declaration of Conformity or our Declaration of Manufacturer. The current Declaration of Conformity / Declaration of Manufacturer are available in the Internet under www.gestra.en/documents or can be requested from us. 5

Technical data NRG 16-50, NRG 17-50, NRG 19-50 Service pressure NRG 16-50: PN 40, 32 bar at 238 C NRG 17-50: PN 63, 60 bar at 275 C NRG 19-50: PN 160, 100 bar at 311 C NRG 111-50: PN 320, 183 bar at 357 C Mechanical connection Screwed G ¾ A to ISO 228-1 (NRG 16-50, NRG 17-50, NRG 19-50) Screwed G 1 A to ISO 228-1 (NRG 111-50) Materials Screw-in body: 1.4571, X6CrNiMoTi17-12-2 (NRG 16-50, NRG 17-50, NRG 19-50) Screw-in body: 1.4529, X1NiCrMoCuN25-20-7 (NRG 111-50) Measuring electrode: 1.4571, X6CrNiMoTi17-12-2 (NRG 16-50, NRG 17-50, NRG 19-50) Measuring electrode: 1.4122, X39CrMo17-1 (NRG 111-50) Electrode tip: 1.4401, X5CrNiMo17-12-2 Electrode insulation: Gylon (NRG 16-50, NRG 17-50, NRG 19-50) Electrode insulation: special ceramic (NRG 111-50) NRG 1...-50: Four-pole connector: polyamide (PA) NRG 1...-50F: Terminal box 3.2161 G AlSi8Cu3 Lengths supplied 500 mm, 1000 mm, 1500 mm, 2000 mm, 2500 mm, 3000 mm ph value Max. admissible: 10 (NRG 111-50) Electrical connection NRG 1...-50: Four-pole connector, cable glands M 16 NRG 1...-50F: Terminal box made from aluminium, cable gland M 20 Protection IP 65 to EN 60529 Admissible ambient temperature Max. 70 C Weight Approx. 1.2 kg (without extension) (NRG 16-50, NRG 17-50, NRG 19-50) Approx. 2.1 kg (without extension) (NRG 16-50F, NRG 17-50F, NRG 19-50F) Approx. 1.8 kg (without extension) (NRG 111-50) Approx. 2.7 kg (without extension) (NRG 111-50F) Approvals EC Prototype approval PED Pressure Equipment Directive 97/23/EC, EN 12952-11, EN 12953-09: Requirements made on limiting equipment for boilers. Functional Safety SIL 3 acc. to EN 61508: Functional safety of safety-related electrical/electronic/programmable electronic systems TÜV type approval VdTÜV Bulletin "Water Level 100": Requirements made on water level limiting & control equipment. Type approval no. TÜV SWB / SHWS..-422 (see name plate) UL/cUL (CSA) Approval UL 508 and CSA C22.2 No. 14-13, Standards for Industrial Control Equipment. File E243189. 6 Gylon is a registered trademark of Garlock Sealing Technologies, Palmyra NY, USA

Technical data - continued - Scope of supply NRG 16-5 1 Level electrode NRG 16-50, PN 40 1 Joint ring 27 x 32, form D, DIN 7603, 1.4301, bright annealed 1 Washer with set screw (measuring surface extension) (optional) 1 Retaining ring (optional) 1 Installation manual NRG 17-50 1 Level electrode NRG 17-50, PN 63 1 Joint ring 27 x 32, form D, DIN 7603, 1.4301, bright annealed 1 Washer with set screw (measuring surface extension) (optional) 1 Retaining ring (optional) 1 Installation manual NRG 19-50 1 Level electrode NRG 19-50, PN 160 1 Joint ring 27 x 32, form D, DIN 7603, 1.4301, bright annealed 1 Washer with set screw (measuring surface extension) (optional) 1 Retaining ring (optional) 1 Installation manual NRG 111-50 1 Level electrode NRG 111-50, PN 320 1 Joint ring 33 x 39, form D, DIN 7603, 1.4301, bright annealed 1 Washer with set screw (measuring surface extension) (optional) 1 Retaining ring (optional) 1 Installation manual 7

Technical data - continued - Name plate/marking Equipment designation Safety note Disposal note Pressure rating, thread type, material number, type approval number CE Marking Manufacturer Serial number Fig. 1 Safety note Equipment designation Pressure rating, thread type, material number Pressure/temperature rating CE Marking, type approval Disposal note Manufacturer Serial number Fig. 2 Fig. 3 8

Installation Dimensions NRG 16-50, NRG 17-50, NRG 19-50 175 GESTRA Steam Systems GESTRA 272 140 b = 70 3000 100 8 G ¾ A, ISO 228-1 G ¾ A, ISO 228-1 100 338 3000 23 Fig. 4 NRG 16-50, NRG 17-50, NRG 19-50 with four-pole connector and measuring surface extension Fig. 5 NRG 16-50F, NRG 17-50F, NRG 19-50F with aluminium terminal box 9

Installation - continued - Dimensions NRG 111-50 175 140 b = 70 425 3000 136 338 30 G 1 A, ISO 228-1 G 1 A, ISO 228-1 30 136 3000 Fig. 6 NRG 111-50 Fig. 7 NRG 111-50F 10

Installation - continued - Tools Note n One level electrode NRG 1...-50 can be installed together with one GESTRA level electrode, one level switch or transmitter for water level control or high level alarm in one single protection tube or level pot (inside diameter 100 mm). Fig. 17. If the electrode NRG 1...-50 is installed inside the vessel, it must be at least 40 mm away from the upper vent hole. n The installation of two water-level limiting electrodes NRG 1...-50 in one single standpipe is not allowed. n For the approval of the boiler standpipe the relevant regulations must be considered. n Refer to pages 16 17 for typical installation examples. n The angle of inclination of the electrode must not exceed 45, with the length of the electrode rod being limited to 1000 mm. Fig. 16, 20 n If used in combination with level switch NRS 1-50 with a response sensitivity of 0.5 µs/cm please us a measuring surface extension. n For outdoor installations please use level electrode NRG 1...-50 F. Level electrodes with this suffix (F) feature a terminal box made from aluminium. Attention n The seating surfaces of the standpipe or the flange provided on the vessel must be accurately machined, see Fig. 12. n If the level electrode NRG 111-50 is to be installed in a flanged standpipe DN 50 use only the GESTRA hat flange. Fig. 11 n Do not bend electrode tip when mounting. n Use only the joint rings supplied with the electrode. NRG 16-50, NRG 17-50, NRG 19-50: 27 x 32, form D, DIN 7603, 1.4301 NRG 111-50: 33 x 39, form D, DIN 7603, 1.4301 n Do not lag electrode body above the hexagonal section. n Do not insulate electrode thread with hemp or PTFE tape! n Do not apply conductive paste or grease to the electrode thread! n Make sure that the air distance between the electrode rod and earth (flange, vessel wall) is not less than 14 mm. Fig. 11, Fig. 15-21 n Observe the minimum distances for the installation of the electrode! n Open-end spanner A. F. 13, DIN 3110, ISO 3318 n Open-end spanner A. F. 19, DIN 3110, ISO 3318 n Open-end spanner A. F. 41, DIN 3110, ISO 3318 n Scriber n Hacksaw n Flat file, medium cut, DIN 7261, form A 11

Installation - continued - NRG 16-50, NRG 17-50, NRG 19-50, NRG 111-50 1 2 9 0 a 3 8 4 Fig. 9 5 6 30 Fig. 8 7 14 110 Fig. 11 NRG 111-50 58 Fig. 10 NRG 16-50 NRG 17-50 NRG 19-50 33/40 G ¾ A, ISO 228-1 G 1 A, ISO 228-1 RA 3.2 RA 12.5 0.5 Fig. 12 12

Installation - continued - NRG 16-50, NRG 17-50, NRG 19-50, NRG 111-50, step 1 1. Screw electrode tip 4 into measuring electrode 1. Fig. 8 2. Carefully determine required measuring length of electrode. 3. Mark length of electrode tip 4. 4. Unscrew electrode tip 4 from measuring electrode 1 and cut tip. 5. After visual inspection screw electrode tip 4 into measuring electrode 1. Slide spring 3 along electrode tip 4 so that its end completely enters the small hole 2. 6. Mounting the measuring surface extension: Fit disk 6 to electrode tip, making sure that the electrode tip protrudes 2 mm beyond the bottom of the surface extension disk. Fix the disk in this position with the set screw 5. Push supplied lock washer 7 from below over electrode tip and against surface extension disk 6. NRG 16-50, NRG 17-50, NRG 19-50, NRG 111-50, step 2 7. Check seating surfaces. Fig. 12 8. Place supplied joint ring 8 onto seating surface of the threaded standpipe or flange. Fig. 9 9. Apply a light smear of heat resistant silicone grease (e.g. WINIX 2150) to electrode thread 7. 10. Screw level electrode into threads or flange provided on vessel and tighten with a 41 mm open-end spanner. The torque required when cold is 160 Nm. Key 1 Measuring electrode 2 Bore 3 Spring 4 Electrode tip 5 Set screw 6 Disk (measuring surface extension) 7 Retaining ring 8 NRG 1...-50: Joint ring 27 x 32, form D, DIN 7603, 1.4301, bright annealed NRG 111-50: Joint ring 33 x 39, form D, DIN 7603, 1.4301, bright annealed 9 Seating surface 0 Electrode thread a Thermal insulation, provided on site, d = 20 mm (outside of thermal insulation of steam boiler) 13

K H Installation - continued - NRG 16-50 F, NRG 17-50 F, NRG 19-50 F, NRG 111-50 F, with aluminium terminal box Fig. 13 d c b 1 2 3 4 5 6 6 5 4 3 2 1 e 1 2 3 4 5 6 f Fig. 14 14

Installation - continued - NRG 16-50 F, NRG 17-50 F, NRG 19-50 F, additional information If one level electrode NRG 1...-50 is installed together with one level electrode, one level switch or transmitter (with aluminium terminal box) in a single protection tube or level pot, please observe the following: 1. Mount the first equipment as specified in the pertinent installation manual. When installing level electrode NRG 1...-50 F, please observe the following instructions: 1. Loosen screws b and remove housing cover d. Fig. 13. The arrow on the name plate points towards this cover. 2. Remove cable lugs from terminal lugs. Fig. 14 3. Loosen nut e with 19 mm open-end spanner but do not remove! Fig. 14 4. Screw in level electrode as described in step 2, items 7 10. 5. Turn electrode terminal box into desired direction (+/-180 ). The terminal box can be turned through +/-180. 6. Tighten nut e with a torque of 25 Nm. 7. Plug cable lugs onto terminal lugs. 5. Mount housing cover d and tighten screws b. Key b Housing screws M 4 c Cable gland M 20 x 1.5 d Housing cover e Nut f Terminal strip 15

Examples of installation NRG 16-50, NRG 17-50, NRG 19-50 G ¾ DN 50 g h 45 j 20 20 i 14 14 n 10 k l o 90 p 20 Fig. 15 Protection tube (provided on site) if electrode is used as internal water-level limiter 14 DN 80 20 max. 1000 Fig. 16 Inclined installation, e. g. in ascending inlet lines of hot-water installations or vessels G¾ g G¾ G¾ 190 g h DN 20 20 j i 20 20 DN 100 24.5 24.5 k m n j 3000 Centre distance 10 p o 90 10 o p DN 20 20 Fig. 17 Protection tube (provided on site) if electrode is used as internal water level-limiter combined with water level control or high water level alarm DN 20 Fig. 18 Level pot DN 80 if electrode is used as external water level limiter 16

Examples of Installation - continued - NRG 111-50 G1 G¾ g DN 50 g h 45 DN 20 190 20 j j n 90 20 10 20 20 i k l o p 14 14 20 14 g max. 1000 Centre distance DN 20 10 p o DN 20 Fig. 19 Protection tube (provided on site) if electrode is used as internal water-level limiter Key Fig. 20 Inclined installation, e. g. in steam boilers Fig. 21 Level pot DN 80 if electrode is used as external water level limiter g Flange PN 40, PN 63, PN 160, DN 50, DIN EN 1092-01 (for one electrode) Flange PN 40, PN 63, PN 160, DN 100, DIN EN 1092-01 (for two electrodes) GESTRA hat flange PN 320, DN 50, DIN EN 1092-01 (NRG 111-50) h For the approval of the boiler standpipe with connecting flange the relevant regulations must be considered. l Vent hole Provide vent hole as close to the boiler wall as possible! j High water HW k Electrode tip d = 8 mm l Protection tube DN 80 (in France according to AFAQ DN 100) m Protection tube DN 100 n Electrode distance 14 mm (air gap and creepage distance) o Low water LW p Reducer DIN 2616-2, K-88.9 x 3.2-42.4 x 2.6 W / DIN 2616-2, K-114.3 x 3.6-48.3 x 2.9 W 17

Electrical connection NRG 16-50, NRG 17-50, NRG 19-50, NRG 111-50, four-pole connector q r s v w t u v Fig. 22 Key q Screw M 4 r Cover s Upper part of terminal box t Connecting plate u Insulating plate v Contact plate of level electrode w Cable strain relief x Cable gland M 16 (PG 9) 18

Electrical connection - continued - Connection of level electrode To connect the level electrode(s) please use: For the level switch NRS 1-50 with a response sensitivity of 10 μs: Multi-core screened control cable, min. conductor size 0.5 mm², e. g. LiYCY 4 x 0.5 mm², max. length 100 m. For the level switch NRS 1-50 with a response sensitivity of 0.5 μs: Multi-core double-screened low-capacitance data cable, min. conductor size 0.5 mm², Li2YCY PiMF 2 x 2 x 0.5 mm², max. length 30 m. Wire terminal strip in accordance with the wiring diagram. Fig. 23. Wire the screens to terminals 5 and 13 and to the central earthing point (CEP) in the control cabinet. NRG 16-50, NRG 17-50, NRG 19-50, NRG 111-50, with four-pole connector 1. Loosen screw q. Fig. 22 2. Remove upper part s of the terminal box from the level electrode but leave insulating plate u on contact plate v. 3. Remove cover r. 4. Press connecting plate t out of the upper part of the terminal box s. The upper part of the terminal box can be turned in steps of 90. 5. Detach cable gland x and cable clamp w from the upper part of the terminal box s. 6. Run cable through cable gland x and upper part of the terminal box s and wire terminals of the connecting plate t in accordance with wiring diagram. 7. Press connecting plate t into the upper part of the terminal box and align cable. 8. Fix cable with cable strain relief w and cable gland x firmly into position. 9. Replace cover r and insert screw q. 10. Put upper part of the terminal box onto the level electrode and fix it with screw q. NRG 16-50 F, NRG 17-50 F, NRG 19-50 F, NRG 111-50 F, with aluminium terminal box 1. Loosen screws b and remove housing cover d. Fig. 13, 14 2. Loosen cable gland c. Pull cable through cable entry. 3. Remove terminal strip f from board. 4. Connect terminal strip according to the wiring diagram. 5. Attach terminal strip. 6. Tighten the cable gland in order to seal the cable entry. Use the supplied sealing plug to seal off the unused cable entry and tighten the cable gland. 7. Mount housing cover d and tighten screws b. Tools n Screwdriver, size 1 n Screwdriver, size 2.5, completely insulated according to DIN VDE 0680-1 n Open-end spanner A.F. 18 (19) mm 19

Electrical Connection - continued - Wiring diagram 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 z * * + - + - z CEP NRG 1..-11 3 2 1 NRG 1..-50 3 2 1 y CEP NRG 1..-11 NRG 1..-50 y Fig. 23 Fig. 24 Wiring of level electrode with four-pole connector LW / HW 1 2 3 4 5 6 Fig. 25 Wiring of level electrode with aluminium terminal box NRG 1...-50 6 5 4 1 3 2 * 3 4 1 2 11 12 9 10 5 13 CEP Terminal strip NRS 1-50 * NRS 1-50 with response sensitivity 0.5 μs/cm: Connect the two internal screens to terminals 5 and 13 and the CEP. Key y Level electrode NRG 1..-50, NRG 1..-11 z Stand-by input 1 / 2, 24 VDC, for connecting logic unit SRL CEP Central earthing point in control cabinet 20

Commissioning, fault indication and troubleshooting For additional information on commissioning procedures and troubleshooting refer to the installation manual of the level switch NRS 1-50. Removing and disposing of the level electrode Danger When loosening the electrode steam or hot water might escape! This presents the risk of severe scalding all over the body! It is therefore essential not to dismantle the electrode unless the boiler pressure is verified to be 0 bar. The electrode becomes hot during operation. Risk of severe burns to hands and arms. Before carrying out installation and maintenance work make sure that the steam trap is cold. Removing and disposing of level electrode NRG 1..-50 1. Loosen screw q. Fig. 22 2. Detach upper part of the terminal box s from the level electrode. 3. Before removing the equipment make sure that is is neither hot nor under pressure. For the disposal of the equipment observe the pertinent legal regulations concerning waste disposal. Removing and disposing of level electrode NRG 1..-50F 1. Loosen screws b and remove housing cover d. Fig. 13, 14 2. Unplug connecting cables from terminal strip and pull cables out of the cable gland. 3. Before removing the equipment make sure that is is neither hot nor under pressure. For the disposal of the equipment observe the pertinent legal regulations concerning waste disposal. If faults occur that are not listed above or cannot be corrected, please contact our service centre or authorized agency in your country. 21

For your Notes 22

For your Notes 23

GESTRA Agencies all over the world: www.gestra.de Great Britain Flowserve GB Limited Abex Road Newbury, Berkshire RG14 5EY Tel. 0044 16 35 / 46 99 90 Fax 0044 16 35 / 3 60 34 E-Mail gestraukinfo@flowserve.com Web www.flowserve.com Singapore Flowserve Pte. Ltd. 12 Tuas Avenue 20 Singapore 63882 Tel. 0065 / 68 79 89 00 Fax 0065 / 68 62 49 40 E-Mail fcd_gestra_singapore@flowserve.com Web www.gestra.com South Africa Flowserve SA (Pty) Ltd. Unit No. 1 Director Road Spartan Extension 2 Kempton Park 1613 Tel. 0027 11 / 9 23 73 00 Fax 0027 11 / 9 74 64 20 E-Mail tvniekerk@flowserve.com Web www.flowserve.com USA Flowserve GESTRA U.S. 2341 Ampere Drive Louisville, KY 40299 Tel. 001 502 / 267-22 05 Fax 001 502 / 266-53 97 E-Mail fcd-gestra-usa@flowserve.com GESTRA AG P.O.Box 10 54 60, D-28054 Bremen Münchener Str. 77, D-28215 Bremen Tel. 0049 (0) 421 / 35 03-0 Fax 0049 (0) 421 / 35 03-393 E-Mail gestra.ag@flowserve.com Web www.gestra.de 818954-04/04-2014cm (808807-05) GESTRA AG Bremen Printed in Germany 24