Pharmacy Solution Set

Similar documents
CONSIDERATIONS ON FACILITY AND ENGINEERING CONTROLS IN THE WAKE OF USP <800>

PHARMACY DESIGN GUIDANCE UPDATE ON COMPLIANCE WITH USP CHAPTER 797 PHARMACEUTICAL COMPOUNDING - STERILE PREPARATIONS

Ventilation for Healthcare Facilities

Ventilation for Healthcare Facilities. Topics to be Covered

Clean Room Certification Is Your Compounding Environment in Compliance. Don Filibeck, PharmD, MBA, CSP Jim Wagner

OUR TRUSTED SERVICE & SUPPORT

Clarification Proposal Annex 1, PDA: A Global. Cleanroom and. Association. Clean Air Devices. Hasim Solmaz Lighthouse Worldwide Solutions

BARRIER TECHNOLOGY RABS & ISOLATORS FOR ASEPTIC PROCESSING

Session VI Smart safety systems

Contamination Control for Life Science Applications

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Cleanroom Technology. Complete solutions for pharmacies.

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

Factory & Hospital hygiene, Chap 21(7 th edition) Principles of GMP, Chap 23 (8 th edition )

Iso Solutions. Enabling wellbeing

CIRCULAIRE LAMINAR AIR FLOW

Press Presse Press Presse

Poor cleaning practices are associated with microbial contamination

Contamination Control for Electronic and Semiconductor Applications

Recently, Trissel et al.1 demonstrated

The Logistics of Filling and Freeze Drying using Multiple Isolators. The use of isolator technology to fill and lyophilize pharmaceuticals

Theatre Classification and Air Particle Count Is that Surveillance?

Differences Matter: Knowing BMS and EMS Systems By: Jason Kelly

FLUID BED EQUIPMENT. Drying

CBC s Inspection Findings and Possible Remedies Thereto

Aseptic Barrier Systems

For over 30 years, our focus has been to protect animal health and research in Pharmaceutical, Government and University animal research facilities.

IVF/ART Series Laminar Flow Cabinets

FagronLab NP-1 UV. Negative pressure workbench. User Manual

Howorth Air Technology. Pharmaceutical Containment Solutions

Air Showers The Safety Solution for Animal Research Laboratories. Viva Air Shower, Model - EAS-1B.

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

RPM1600 Series Room Pressure Monitors

Howorth Air Technology. Pharmaceutical Containment Solutions

Common Customer Challenges

STANDARD OPERATING PROCEDURE 1/1/07 DYCEM HOUSEKEEPING Medical Devices and Terminal Sterilized Pharmaceutical Products

Smoke detection in hazardous areas:

NGV MAINTENANCE FACILITIES Code Related Modifications For NGVs In Existing Maintenance Facilities

The overview of standard of equipments used in asbestos removal Naroo Lee, Ph.D./Department of work environment

Isolators, RABs and Mobile Clean Rooms in Aseptic Processing. Gary Partington Walker Barrier Systems

Cleveland Clinic Design Standards MECHANICAL SYSTEMS DESIGN GUIDELINES HVAC AIR DISTRIBUTION PART I - GENERAL 1.1 SUMMARY

Safe Operating Procedure (Revised 2/10)

Laboratory Equipment LAMINAR FLOW CABINETS ENVAIR ECO AIR H ISO CLASS 3 HORIZONTAL PRODUCT PROTECTION CABINET

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

Submittal Data Performance Data Electrical Data

BioSafety Cabinet- Class 100

Virginia Tech Standards for Building Automation System

GMS GRAPHICAL MANAGEMENT SYSTEM

Gelaire BH-EN and UltraSafe cabinets

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

TOPICS IN CODE ENFORCEMENT

MIRADOR Real Time Monitoring

Pharmaceutical Facility Design

Florida International University. Biosafety Cabinet Program

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)

REAL TIME LABORATORY MONITORING SYSTEM

Models: 1828 and and 1846

Computerized Facility Management

4/18/2017. *2012 edition of NFPA 99 has gone through a major overhaul. *This document is now a Code.

Combustible Dust Hazards- Awareness

Fedegari Aseptic Technology Integration: Case Study. Sergio Mauri, Director, Global Integrated Projects

UNIVERSITY OF ALASKA FAIRBANKS DIVISION 25- INTEGRATED AUTOMATION DESIGN STANDARDS SECTION INTEGRATED CONTROL OF FACILITY LAB FUME HOODS

Faster BH-EN and BHG Class II Microbiological Safety Cabinets

G INSPECTION, TESTING, AND MAINTENANCE OF COMPANY-OWNED AUTOMATIC TEMPERATURE CONTROL EQUIPMENT

Pharmacy Quality Assurance Self-Assessment (Sterile Compounding Hazardous and Non Hazardous)

Biosafety Cabinets and Fume Hoods Supplemental Material (OHS_BIO304)

LABORATORY EQUIPMENT. A. Section Accessibility for People with Disabilities. B. Section Plumbing Basic Materials and Methods

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

10606 Bloomfield Ave Santa Fe Springs, CA USA

OPERATION AND MAINTENANCE MANUAL

PRODUCT LINE ULTRAFIL AIR SYSTEMS First... In Clean Air CLEAN AIR PRODUCTS LAMINAR AIR FLOW WORK STATION: (Vertical and Horizontal) Construction made

(h) Pesticide Application.

w SYSTEM DESCRIPTION The Hu//Lyophi/izer System (LP-0106) performs the freeze-drying of liquid pharmaceutical product. It has a 300 ft2 shelf area

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

Airflow Direction Incorporated The BALL-IN-THE WALL* Indicator Company 2 Livingston Lane, Newbury, MA 01951

SUCCESS STORY EUROPA-PARK A WinGuard Reference Project

FITOCLIMA 600 & 1200 STABILITY

Manage Alert Rules & Teams

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

SEMICONDUCTOR FABRICATION FACILITIES

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Safety Instrumented Fire & Gas Systems

Getinge 9100E Cart Washer-Disinfector. Your safe, efficient and sustainable cleaning solution

Lead-Lined Cabinetry. 7 Vreeland Road, Florham Park, NJ or

Considering Filtration. Austin Baker Ventilation Director Hog Slat, Inc

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

Product Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management

Preventing Fires And Explosions In Pilot Plants And Laboratory Units

WORKPLACE INSPECTION CHECKLIST FOR LABORATORY ENVIRONMENTS

CelCulture. Cradle for Beautiful Cells. CelCulture Water-Jacketed CO 2 Incubator

SmartShelter Room. Technical Description. Version 1.1 Jul. 2017

Corporate. Laundry SOP. Document Control Summary

NC Department of Insurance Office of the State Fire Marshal - Engineering Division 1202 Mail Service Center, Raleigh, NC

MODULAR INTEGRATION OF PROCESS EQUIPMENT PACKAGES FOR OIL AND GAS FACILITIES

INC. DESIGN AND INTEGRATION OF ADVANCED SYSTEMS. Multipli Cité REMOTE WATER TREATMENT MANAGEMENT SYSTEM

Models 1839 Forma Laminar Airflow Workstation Class 100 Operating and Maintenance Manual Rev. 6

CLEAN AIR SYSTEM.

SECTION CENTRIFUGAL WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

SEMICONDUCTOR FABRICATION FACILITIES

Transcription:

Pharmacy Solution Set Siemens Pharmacy Solution Set is a bundled offering of products, systems, technologies, programs, and services specifically designed to help organizations meet the environmental requirements of USP 797 and 800. Our solution is built with flexibility in mind, allowing us to assemble a customized solution to meet each customer's unique requirements, depending on their current level of compliance. This document is based on the proposed requirements of: USP 797 : Pharmaceutical Compounding Sterile Preparations (Proposed Revisions - September 2015) USP 800 : Hazardous Drugs Handling in Healthcare Settings (Proposed Revisions - February 2016) Dino Coliano Business Leader, Healthcare Siemens Industry, Inc. Building Technologies Division 1 972-207-2832 dino.coliano@siemens.com Lonnie Spears Senior National Sales Manager, Life Sciences Siemens Industry, Inc. Building Technologies Division 1 847-212-6809 lonniespears@siemens.com

Service Environmental Controls Primary Engineering Controls (PECs) All CSPs must be prepared in an ISO Class 5 environment. Class 5 standards are achieved through the use of a PEC or an Isolator. Containment Primary Engineering Controls (C-PECs) All sterile and non-sterile Hazardous drugs as defined by NIOSH 1 must be compounded within a C-PEC. The C- PEC must operate continuously if used for sterile compounding or if it supplies negative pressure. Buffer / Clean Room Areas 2,3 PECs need to be located within a Buffer or clean-room area with at least ISO Class 7 air quality. An ante-area provides access to the buffer area and must meet at least ISO 8 standards (ISO 7 standards for sterile HD preparations). Containment Secondary Engineering Controls (C-SEC) C-PECs must be located with a C-SEC. The C-SEC must be: Pre-Assessment Questionnaire Assessment of Current Environment Air Cleanliness Room Construction Exhaust System Mechanical System Temperature and Humidity Ventilation Pharmacy Assessment Report Design, install and commission (enhanced) room controls for the buffer and anteroom areas, to achieve desired airborne particle count, air changes per hour, differential pressure, temperature, and humidity levels. Note: For sterile HD compounding, C-PECs must be externally vented. Fire Alarm System per local codes Back-up to EES (Essential Electrical System) Power per NFPA 99 Design, install and commission building system information management elements: The Desigo CC workstation serves as the primary interface into the building automation system for real-time monitoring, troubleshooting, controlling building systems, managing alarms, collecting trend data (i.e., temperature, humidity, pressure, air changes per hour, alarm statuses). The RENO, Remote Notification Option for Desigo CC, allows notification of Alarm, Status and System Event information to be sent via e-mail, pagers, and phones via SMS (Short Message Service) for all points integrated into the system. Desigo CC provides a means of archiving, managing, processing and retrieving business critical data for a range of information management / reporting needs including analysis, compliance and management reporting. Compliance Services: Clean Room Testing and Certification Cabinet Testing and Certification Calibration Training Documentation Facility Information Services: Environmental Reporting and Consulting Custom Report Design and Creation (Temperature, Humidity, ACH, Positively Pressurized.) If equipment is integrated, reports can also include; refrigerator / freezer temperatures and particle counter readings. Data Archiving and Retrieval User Training 1 National Institute for Occupational Safety and Health. 2 If used to prepare only Category 1 CSPs, the PEC may be located in an unclassified area, without a buffer or ante-area. The area must be a Segregated Compounding Area. 3 If ISO class 5 is achieved using an isolator, the isolator can be located in an ISO Class 8 area and used to prepare Category 2 CSPs. s based on: 2) USP 800: Hazardous Drugs Handling in Healthcare Settings (Proposed Revisions February 2016) Page 2 of 6

Service Externally vented through HEPA filters Be physically separated Pressure between -03 to -.01 in WC The ante-room which provides entry into an HD buffer room must have: HEPA Filter supplied 30 ACPH Positive pressure of.02 in WC relative to all adjacent unclassified spaces ISO Class 7 or higher Contained Segregated Compounding Area (C-SCA) C-PEC may be placed in an unclassified C-SCA if the following is met: HEPA Filter supplied 12 ACPH Pressure between -03 to -.01 in WC to adjacent spaces Low and Medium risk HD CSPs Workbenches / Barrier Isolators PECs generally include laminar airflow workbenches, biological safety cabinets, and isolators. Compounding facilities must be designed and controlled to provide a well-lit and comfortable working environment. The room must be maintained at a temperature of 20C or cooler and a humidity below 60% at all times. s based on: 2) USP 800: Hazardous Drugs Handling in Healthcare Settings (Proposed Revisions February 2016) Page 3 of 6

Service Security Access of personnel to controlled areas must be restricted. The PEC must be located in a controlled access buffer area. Airlocks and interlocking doors can be used to facilitate better control of air balance between higher classified area and an area of lesser air quality (e.g., between the buffer area and ante-area), or between a classified area and an unclassified area Assessment Secure access into the controlled area via: Card Access CCTV Digital Recording Door interlocks Hands-free doors Intrusion Monitoring and Alarming Door status Door access restrictions Door interlocks Security Services When designing the facility, hands-free access doors are preferred. Access to areas where HDs are handled must be restricted to authorized personnel. Environmental Monitoring (of Room) ISO Class 7 Buffer or ante-area supplied with HEPA filtered air must measure be minimum of 30 ACPH. A minimum D/P of.02in WC is required between ISO classifications and the buffer area and the pharmacy. A pressure gauge or velocity meter must be used to monitor the D/P or airflow between the Buffer and anti-room and between the anti-room and the general Assessment Design, install and commission (enhanced) room controls for the buffer and anteroom areas, to achieve desired airborne particle count, air changes per hour, differential pressure, temperature, and humidity levels The Desigo CC workstation serves as the primary interface into the building automation system for real-time monitoring, troubleshooting, controlling building systems, managing alarms, collecting trend data (i.e., temperature, humidity, pressure, air changes per hour, alarm statuses). Facility Information Services Environmental Reporting and Consulting Custom Report Design and Creation (Temperature, Humidity, ACH, Positively Pressurized.) If equipment is integrated, reports can also include: refrigerator / freezer temperatures and particle counter readings. Data archiving and retrieval User Training s based on: 2) USP 800: Hazardous Drugs Handling in Healthcare Settings (Proposed Revisions February 2016) Page 4 of 6

Service environment. The results must be logged daily or recorded by a continuous monitoring device. Total (non-viable) particle counts on ISO areas must be conducted during operations every 6 months. The air quality of the buffer, PEC and anteroom area is evaluated by a qualified operator(s) for conformance to ISO Class requirements, as appropriate, at least every six months and when renovations occur. All certification and re-certification records must be reviewed by supervising personnel or other designated employees to ensure the environments comply with proper standards. Clean room Testing and Certification (may include following tests): Air volume and velocity HEPA filter Integrity test Pressurization (includes room air exchange rates) Airborne particle count Smoke testing Recovery test Temperature and humidity Controlled Storage Areas CSPs may be stored under different storage conditions before they are used. The following storage conditions apply: Controlled Room Temp; 20 25C Refrigerator; 2-8 C Freezer; -25 to -10 C To help ensure CSP quality, personnel must monitor conditions in the storage areas. Controlled temperature must be checked at least daily and the results must be documented in a temperature log. If a continuous recording device is in use, personnel must check at least daily that it is functional. Data integration of refrigerators / freezers into Desigo CC for monitoring, documenting and alarming. Building Automation System collects trend data and alarm statuses from integrated equipment Remote notification of alarm conditions can be provided to Pharmacy and Facility Staff Facility Information Services Environmental Reporting and Consulting Custom Report Design and Creation (Temperature, Humidity, ACH, Positively Pressurized.) If equipment is integrated, reports can also include; refrigerator / freezer temperatures and particle counter readings. Data Archiving and Retrieval User Training s based on: 2) USP 800: Hazardous Drugs Handling in Healthcare Settings (Proposed Revisions February 2016) Page 5 of 6

Service CSPs that are exposed to temperatures that exceed storage temperature limits shall be discarded. HDs must be stored in a negative pressure room with at least 12 ACPH. HDs used in sterile compounding may be stored in the negative pressure buffer room. Refrigerated HDs must be stored in a dedicated refrigerator in a negative pressure area with at least 12 ACPH. Standard Operating Procedures The compounding facility must establish and follow written standard operating procedures (SOPs) designed to ensure the quality of the CSP. Documentation Standards All records must be retained for at least 3 years or as required by the state laws and regulations, whichever is longer. Desigo CC provides a means of archiving, managing, processing and retrieving business critical data for a range of information management / reporting needs including analysis, compliance and management reporting. Training Documentation s based on: 2) USP 800: Hazardous Drugs Handling in Healthcare Settings (Proposed Revisions February 2016) Page 6 of 6