Ozone Generator Systems

Similar documents
Ozone Generator Systems

PZ2 Series Manual. PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems. INSTALLATION GUIDE and OPERATION MANUAL. Prozone PZ2 Series

EcoMaster - Residential Pools up to 40,000 Gallons

PZ1, PZ3 & PZ6 Installation Guide

EcoMaster - Residential Pools up to 40,000 Gallons

Vacuum-ultraviolet Ozone Systems. Installation & Operation Manual. Model OZ-SPA

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

Next Generation Corona Discharge Installation & Operation Manual

OZONE SYSTEM FOR IN-GROUND POOLS UP TO 18,000 GALLONS

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Important Safety Instructions

Next Generation Corona Discharge Next Generation Corona Discharge Nueva generación Corona de descarga

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

A2Z Ozone, Inc. PRODUCT MANUAL

Copyright. Prozone Water Products,Inc. phone: fax:

Clear Comfort Residential Pool & Spa Sanitization System Installation, Operations & Maintenance Manual

1, 2, & 4. Corona Discharge Ozone Generators INSTALLATION & OPERATION MANUAL. DEL Ozone SAN LUIS OBISPO, CA USA Fax:

register your product at a2zozone.com/pages/warranty SP Series Operating Manual

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

WATER PURIFYING SYSTEM

DEL AOP 25 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

M770 ph Controller Owner s Manual

M790 ph/orp Controller. Owner s Manual

Owner s Manual. Installation, Operation and Maintenance SC-OZ, SC-OZ/2, S2Q-OZ, S2Q-OZ/2, S8Q-OZ, S8Q-OZ/2. Manufactured in Canada by:

Owner s Manual RD432-0 Chemical Controller

Installation and Operation Manual. ACF-18 Automatic Chlorinating Feeder

HydroRite UVO 3. Troubleshooting Guide Residential. TSG-UVO158a. Copyright 2015 Hayward Industries Inc.

Installation and Operation manual WARNING

PATENTED APG OZONE CELLS DESTROYS HARMFUL CONTAMINANTS REDUCE CHEMICAL DEMAND

Air Preparation System

BALLAST REPLACEMENT. Contents WARNING INSTALLATION MANUAL

#300 & #302 CHLORINEIBROMINE FEEDERS

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Ozone plus UV Sanitation System Installation & Operations Manual

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR- DWSH01- S

Installation Instructions

Installation Instructions

Owner s Manual AQ-RO-BASE. Aquasana OptimH2O Drinking Water System Reverse Osmosis Filtration Technology

HARMSCO INSTALLATION AND OPERATION MANUAL UPFLOW SWIMMING POOL CARTRIDGE FILTER CARTRIDGE CLEANING INSTRUCTIONS HARMSCO CARTRIDGES

Installation Instructions

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

IMPORTANT SAFETY INFORMATION READ ALL...

Air Preparation System

J-PRO V 230V Dual Voltage Chlorinator Installation & Start-Up Guide

WINTERIZATION INDUSTRY BEST PRACTICE

Arch Feeder: Installation Manual

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

NANO TECH UV-C DISINFECTION SYSTEM

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Ozone plus UV Sanitation System Installation & Operations Manual

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

Owner s Manual LIMITED WARRANTY INFORMATION OBTAINING WARRANTY SERVICE FURTHER LIMITATIONS AND EXCLUSIONS ARE AS FOLLOWS REGISTRATION

INSTALLATION, OPERATION AND MAINTENANCE

Ozone + UV Sanitation

SAVE THESE INSTRUCTIONS

Viking Installation Guide

M820 ph/dual ORP Controller. Owner s Manual

Dishwasher Installation Instructions DW 24XT/DW 24XV

Electrical Field. Molecular weight: 48. Color: Solubility: Ozone leaves no telltale taste or odor.

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

Installation & Operation Manual. AromaFlo. mr.steam. Feel Good Inc.

L A signature series TA T N E RE O, A L L A T S IN

Installation Instructions

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

Dual Column Dehydrating Breather Manual

Installation. Leveling

INSTALLATION INSTRUCTIONS

PIPE DREAMS 96. Aeroponic Garden IMPORTANT:

HydroRite UVO3. 2 Residential UV/Ozone Sanitizing System. Owner s Manual. Contents. Model: HYD-UVO

VMUS-4 Ozone Generator

ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS

Owner s Manual AQ-RO-3. Aquasana OptimH2O Drinking Water System. Reverse Osmosis plus Claryum Filtration Technology

Installation Instructions

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

SolidFlo G2 Solid Handling Pumps Product Manual

INSTALLATION. Glass Panel Doors (select models) CAUTION

PolyMax H2-24 Dutch Bucket System

THE ULTIMATE NON-CHEMICAL POOL/SPA WATER STERILISATION

PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES THE BASIC REVERSE OSMOSIS SYSTEM. Tools and Materials Required

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

INSTALLATION INSTRUCTIONS

SYSTEMS for CATALYTIC FILTERS

Gen II Entree Bath - All Models

FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR-DWSH01-S

Ozone Systems. Installation & Operation Manual CD15nx CD30nx. Corona Discharge Ozone Generators. ClearWater Tech, LLC. Integrated Ozone Systems

A2Z Ozone Inc. Clean Water and Pure Air for ALL around the world! Product Catalog 2014/15

WATER FILTRATION SYSTEM (USF3) OWNER S MANUAL

Transcription:

PZ2-4V - Commercial and Residential Pools & Spas Ozone Generator Systems INSTALLATION GUIDE and OPERATION MANUAL T. O3 NATURAL TECHNOLOGY Reduces Chemical Usage, Improves Sanitation Produces Crystal Clear Water Copyright 2007 Prozone Water Products: 3004 11th Ave. - Huntsville, AL - 35805 Phone: 256-539-4570 Website: www.prozoneint.com 202009

IMPORTANT SAFETY INSTRUCTIONS Read and Follow All Safety Instructions Read and be familiar with this manual before installing, operating, or performing maintenance on the PZ2. Voltage must be determined before unit is installed. Replace damaged cord immediately. Do not bury cord. Connect only to a properly grounded, grounding type receptacle. Install at least 5 feet from the inside wall of the pool using non-metallic plumbing. The ozone generator is to be located one foot minimum above the maximum water level to prevent water from contacting electrical equipment. Install to provide drainage of compartment for electrical components. A pressure wire connector is provided in the control box inside the unit to permit connection of a minimum No. 8 AWG solid copper bonding conductor between this point and any metal equipment, metal enclosures of electrical equipment, metal water pipe, or conduit within 5 feet of the unit as needed to comply with local requirements. Wear safety glasses when drilling and tapping holes for installation of unit. WARNING: Short term inhalation of high concentrations of ozone and long term inhalation of low concentrations of ozone can cause serious harmful physiological effects. Do not inhale ozone gas produced by this device. WARNING: Disconnect all power to pool equipment prior to installation, maintenance, or removal of the PZ2. WARNING: Do not permit children to operate this product WARNING: To avoid risk of electric shock, fire, or injury, service should only be performed by a qualified pool service professional. WARNING: Installation must be performed in accordance with the National Electric Code and any applicable local or state installation codes. WARNING: When mixing acid with water, ALWAYS ADD ACID TO WATER, NEVER WATER TO ACID. NOTE: The instructions in this document provide general installation guides. Consult your dealer for specific installation instructions. Additional information is available at www.prozoneint.com. Check system for any visible shipping damage. If damage has occurred, contact the delivery company and your dealer immediately. Before beginning installation, please turn to the Installation Kit Inventory Section and verify that all listed parts are on hand. Tools Needed: Cordless Power Drill, Flat Head Screwdriver, Phillips Head Screwdriver, Hand Saw, Utility Knife, Adjustable Wrench, Pliers, PVC Glue, Teflon Tape, Wall Mount Screw Anchors SAVE THESE INSTRUCTIONS 2

Installation INTRODUCTION TO OZONE Ozone (O 3) is generated by irradiating air or oxygen (O 2) with ultraviolet radiation. Ozone is a molecule of oxygen that is formed when three atoms of oxygen are bound together instead of the normal two atoms. The extra oxygen atom makes ozone the most powerful oxidizer and sanitizer readily available. Since ozone is unstable and quickly decomposes to normal oxygen under normal conditions, it cannot be shipped or stored. Therefore, it must be manufactured on site for immediate use. In normal air it lasts about an hour. In normal pool water it lasts just long enough to purify the water - less than 1 second. Although ozone is mainly thought of as a sanitizer, it acts primarily as an oxidizer in the pool environment. In a typical pool run on chlorine only, up to 90 percent of the chlorine may be used up in reactions unrelated to disinfection. The by-products of these reactions are combined chlorines. Combined chlorines are the cause of eye irritation, odor, and the other unpleasant side effects of chlorination. When ozone is used, it oxidizes a large portion of the contaminants (usually referred to as bather load) which result in the formation of combined chlorines. The result is that more chlorine is available for disinfection and less chlorine is required to maintain the pool. Ozone also provides some disinfection, but an ozone residual cannot be established, so the use of chlorine or bromine is always recommended. PREPARING FOR INSTALLATION 1. 2. 3. 4. 5. 6. 7. Check electrical system: 240VAC double switched per N.E.C. standards; 120VAC single switched. Check for all leaks in existing plumbing and correct where necessary. Ensure you have the proper tools (see list). Backwash the filter. Brush the pool. Balance the ph. Shock the pool with a non-lithium-based material. The use of Calcium Hypochlorite or Sodium Hypochlotite is recommended. The Table below summarizes the levels that are recommended by The Association of Pool and Spa Professionals (APSP). It is important to maintain these levels in order to prevent corrosion or scaling and to ensure maximum enjoyment of the pool. Test your water periodically. Take a water sample in to be professionally tested by a Pool and Spa Professional at least once a month. See our web site for more information on Basic Pool Water Chemistry. ph 7.2 7.6 Alkalinity 80 120 ppm TDS < 1,000 Cyanuric Acid 30 70 ppm Free Chlorine 0.5 1.5 ppm Calcium Hardness 60 400 ppm Metals 0 ppm Nitrates / Phosphates < 30 ppm SADDLE CLAMP ASSEMBLY Venturi Injector (600207) PVC Pipe (20314) For bypass Entrance, (before Ball Valve) Using 1-1/2 pipe, Assemble: Venturi Injector (Note direction) Saddle Clamp Top & Bottom Top & Bottom Adapters Bushing (Note direction) Screws (2) Nuts (2) Screw (2) (201863) Saddle Clamp Top (201155-4) Bushing (201155-5) Top Adapter (201155-2) (400076) For bypass Exit, (after Ball Valve) Using 1-1/2 pipe, Assemble: PVC Pipe Saddle Clamp Top & Bottom Top & Bottom Adapters Bushing (Note direction) Screws (2) Nuts (2) Screw (2) (201863) Saddle Clamp Top (201155-4) Bushing (201155-5) Top Adapter (201155-2) (400076) 7/8" Dia. Hole Bottom Adapter (201155-3) Note: For 2 pipe, do not use 1-1/2 adapters and gasket and turn Bushings so small end points toward Injector (for Entrance) or PVC Pipe (for Exit). 7/8" Dia. Hole Bottom Adapter (201155-3) Saddle Clamp Bottom (201155) 1/4-20 Nut (2) (20703) 3 Saddle Clamp Bottom (201155) 1/4-20 Nut (2) (20703)

Bypass with Saddle Clamps Installation PZ2 7/8 Hole Saw ⅜ Check Valve ½ Check Valve ¾ Hose ¾ Ball Valve (If using a DE filter) ¼ Hose Filter Heater Saddle Clamp Assembly Saddle Clamp Assembly Pool Pump 1. Turn pump OFF. 2. Locate section of existing plumbing in which you choose to install the ENTRANCE leg of the bypass. Location should be in any accessible area after the pump, but before the filter. 3. Install Saddle Clamp Top & Bottom, (and adapters if needed), without Bushing, (this will be used as a guide for your installation hole). 4. Drill a 7/8 hole through one wall of the pipe, using power drill, being careful not to drill too deep to avoid penetrating the opposite side of the plumbing. 5. Locate section of existing plumbing in which you choose to install the EXIT leg of the bypass. Location should be in any accessible area after the filter, and heater (if equipped). 6. Repeat steps 3 & 4. 7. Remove both Saddle Clamp Assemblies. 8. Using components listed, mount one Saddle Clamp Assembly on Entrance bypass location with the INLET side of the Venturi Injector mounted in the Saddle Clamp Bushing, (ozone ports should be facing upward). 9. Using components listed, mount the other Saddle Clamp Assembly on Exit bypass location with the ½ x 3 PVC pipe mounted in the Saddle Clamp Bushing. 10. Attach one end of ¾ clear hose to Venturi Injector and secure with a metal clamp. Attach other end of ¾ clear hose to ½ x 3 PVC pipe and secure with a metal clamp. 11. Mount the PZ2 Ozone Generator to a wall or surface. Unit orientation will not affect performance. Unit must be mounted a minimum of of 1 foot above water level. If unit must be mounted below water level, loop the hose so that at some point it is above water level, (a solenoid control valve may be necessary). 12. Apply Teflon tape to the threads of a ½ MPT x ⅜ HB fitting, part number 20231, and screw into the end of the ½ Check Valve that has the spring in it, (This is the INLET side of the Check Valve). Mark this end as INLET. 13. Apply Teflon tape to the threads of a ½ MPT x ¼ HB fitting, part number 20230, and screw into the opposite of the ½ Check Valve, (This is the OUTLET side of the Check Valve). Mark this end as OUTLET. 14. Cut a 6 inch length of ¼ hose and connect one end to the OUTLET side of the ½ Check Valve and connect the other end to the open ozone port (Marked #1) on the Venturi Injector. Secure with ½ plastic clamps. 15. Cut a 12 inch length of ⅜ hose and connect one end to the INLET side of the ½ Check Valve. Connect the other end to the OUTLET side of the ⅜ Check Valve, (Make sure you can blow air through the Check Valve towards the Injector). Secure both ends with plastic clamps. 16. Attach one end of the remaining ⅜ hose to the INLET side of the ⅜ Check Valve and the other end to one of the PZ2-4V barbs on the bottom of the unit and secure both ends with plastic clamps. (Note: The other barb on the PZ2-4V will be for air inlet, no hose needs to be connected to this barb). 17. Electrical Installation: System is either 120 or 240 VAC, 50/60 HZ. Wire Prozone Ozone Generator system to circulation pump switch or timer. Prozone system and circulation pump should be started simultaneously. Use N.E.C. or local code grounding and installation procedures for swimming pool equipment. CAUTION: Make sure the voltage is the same as prescribed on the side of the Prozone ozone generator. Overvoltage will void customer warranty. Note: If using a Diatemateous Earth filter, install a ¾ ball valve in the ¾ hose to the output side of the venturi, as shown. 4

Bypass with PVC Tees Installation PZ2 ⅜ Check Valve ½ Check Valve ¾ Hose ¾ Ball Valve (If using a DE filter) ¼ Hose Venturi Injector Filter Heater PVC Tee PVC Tee Bypass Entrance Bypass Exit Pool Pump 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. Turn pump OFF. Locate section of plumbing in which you choose to install the ENTRANCE leg of the bypass. Location should be in any accessible area after the pump, but before the filter. Cut away 1-½ out of the existing plumbing at this selected location. Install a PVC Tee with the ¾ FPT portion of the Tee facing upward, using the reducer bushings if necessary. Locate section of plumbing in which you choose to install the EXIT leg of the bypass. Location should be in any accessible area after the filter, and heater (if equipped). Cut away 1-1/2 out of the existing plumbing at this selected location. Install a PVC Tee with the ¾ FPT portion of the Tee facing upward, using the reducer bushings if necessary. Apply Teflon tape to the threads of the (2) ¾ MPT x ¾ HB fittings, part number 20678, and screw the fittings into the (2) PVC Tees you just installed. Cut a 6 length of ¾ hose and connect one end to the fitting on the entrance side of the bypass, (after the pump, before the filter), and secure with a metal clamp. Connect the other end of the 6 hose to the INLET side of the Venturi Injector and secure with a metal clamp. Attach one end of the remaining ¾ hose to the OUTLET side of the Venturi Injector and secure with a metal clamp. Attach other end of ¾ hose to the fitting on the exit side of the bypass, (after the filter/heater), and secure with a metal clamp. Mount the PZ2 Ozone Generator to a wall or surface. Unit orientation will not affect performance. Unit must be mounted a minimum of of 1 foot above water level. If unit must be mounted below water level, loop the hose so that at some point it is above water level, (a solenoid control valve may be necessary). Apply Teflon tape to the threads of a ½ MPT x ⅜ HB fitting, part number 20231, and screw into the end of the ½ Check Valve that has the spring in it, (This is the INLET side of the Check Valve). Mark this end as INLET. Apply Teflon tape to the threads of a ½ MPT x ¼ HB fitting, part number 20230, and screw into the opposite of the ½ Check Valve, (This is the OUTLET side of the Check Valve). Mark this end as OUTLET. Cut a 6 inch length of ¼ hose and connect one end to the OUTLET side of the ½ Check Valve and connect the other end to the open ozone port (Marked #1) on the Venturi Injector. Secure with ½ plastic clamps. Cut a 12 inch length of ⅜ hose and connect one end to the INLET side of the ½ Check Valve. Connect the other end to the OUTLET side of the ⅜ Check Valve, (Make sure you can blow air through the Check Valve towards the Injector). Secure both ends with plastic clamps. Attach one end of the remaining ⅜ hose to the INLET side of the ⅜ Check Valve and the other end to one of the PZ2-4V barbs on the bottom of the unit and secure both ends with plastic clamps. (Note: The other barb on the PZ2-4V will be for air inlet, no hose needs to be connected to this barb). Electrical Installation: System is either 120 or 240 VAC, 50/60 HZ. Wire Prozone Ozone Generator system to circulation pump switch or timer. Prozone system and circulation pump should be started simultaneously. Use N.E.C. or local code grounding and installation procedures for swimming pool equipment. CAUTION: Make sure the voltage is the same as prescribed on the side of the Prozone ozone generator. Overvoltage will void customer warranty. Note: If using a Diatemateous Earth filter, install a ¾ ball valve in the ¾ hose to the output side of the venturi, as shown. 5

Inventory Lists & Troubleshooting INSTALLATION KIT INVENTORY P12 Installation Kit PZ2-4V Bypass with Saddle Clamps Description Part Number Quantity 784 Venturi Injector 600207 1 Plastic Clamp ½ 20185 2 Plastic Clamp ⅝ 20186 4 Metal Clamp 1-¼ 20067 2 PVC Pipe ½ x 3 20314 1 Polybraid Hose ¼ 20260 12 Clear Vinyl Hose ¾ 20264 96 Polybraid Hose ⅜ 20261 144 Check Valve - ½ 20215 1 Check Valve ⅜ 20730 1 Fitting ½ MPT x ¼ HB 20230 1 Fitting ½ MPT x ⅜ HB 20231 1 Saddle Clamp, Outer Top 201155-4 2 Saddle Clamp, Outer Bottom 201155 2 Saddle Clamp, Inner Top 201155-2 2 Saddle Clamp, Inner Bottom 201155-3 2 Saddle Clamp 400076 2 Saddle Clamp Bushing 201155-5 2 Screw #14 x 1-½ PPMS 201863 4 Nut ¼-20 20703 4 P33 Installation Kit PZ2-4V Bypass with PVC Tees Description Part Number Quantity 784 Venturi Injector Assembly 600207 1 Plastic Clamp ½ 20185 2 Plastic Clamp ⅝ 20186 4 Metal Clamp 1-½ 20068 2 Polybraid Hose ¼ 20260 12 Clear Vinyl Hose ¾ 20264 96 Polybraid Hose ⅜ 20261 144 Check Valve - ½ 20215 1 Check Valve - ⅜ 20730 1 Fitting ½ MPT x ¼ HB 20230 1 Fitting ½ MPT x ⅜ HB 20231 1 PVC Tee 2 SL x ¾ FPT 201095 2 PVC Fitting 2 SP x 1-½ SL 201114 4 PVC Fitting ¾ MPT x HB 20678 2 Note: For pools with Diatomaceous Earth filter and Bypass / Venturi Injector installation, add (1) ¾ Ball Valve, (2) ¾ MPT x HB fittings, and (2) 1 ¼ metal clamps. TROUBLESHOOTING GUIDE PROBLEM PROBABLE CAUSE REMEDY No light from Prozone unit Loose wiring No power to unit Defective lamp or other internal component Check all wiring connections Check voltage compatibility Check power source Return unit to dealer No bubbles from injector or no evidence of ozone in pool Excessive back pressure Leak in fitting Filter not working Check for kinks or clogs in hose or plumbing Replace fitting Check filter Water in Ozone Generator Check Valve failure Verify Check Valve in Venturi is operating properly Cloudy water; foamy water; scum Water chemistry out of balance Total Dissolved Solids (TDS) level too high Filter not working Check readings and balance accordingly Refer to dealer for proper water testing Clean or replace filter NOTE: Cloudy water may occur when the ozone generator is started. Clean filter and backwash as necessary. Run the circulation system for 48-72 hours before reverting to your normal cycle. 6