AS 50 operating manual, 2013

Similar documents
Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

UM120W OPERATING MANUAL MANUAL WATERBORNE GUN CLEANER CAUTION FOR WATERBORNE PAINTS ONLY UNI-RAM CORPORATION ONTARIO CANADA

K 5.80 M ( ) Caution! Do not use the unit without first having read the operating instructions.

TH100 Three in One Instant Hot Water Tap

Operating instructions

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

MW402 Integrated Dishwasher

MODULAR AUTOMATIC GRANULAR ICE FLAKER

Arctic EVAPORATIVE COOLER USER MANUAL

AUTOMATIC GRANULAR ICE FLAKER

AUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM

User Instruction Manual

Care and cleaning. 1. Pull out the condensation container. 2. Pull the filter out of its snap-in lock.

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

8L Evaporative Cooler

Installation and Operating Instructions

PJ130S High Pressure Cleaner

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

User Instruction Manual

100 Series Maxi Internal Filters

Silent TS. Nr / Ideas for dental technology / A. Made in Germany

wc431 Slimline Integrated Dishwasher Manual for Installation, Use and Maintenance

AUTOMATIC MODULAR ICE FLAKER

EASYCLEAR 3000 YEAR GUARANTEE

OPERATING MANUAL MANUAL WATER BASE GUN CLEANERS UM120W UNI-RAM CORPORATION ONTARIO CANADA PATENTS

ROTA-SPRAY PROCESSOR MODEL 1210 (ROTARY-JET) INSTRUCTIONS MEGA PART NO: &

Care and cleaning. 1. Pull out the condensation container. 2. Pull the filter out of its snap-in lock.

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

STEAM WALLPAPER STRIPPER MODEL HTW5

FW422. Integrated In Column Larder Fridge. Installation, use and maintenance.

Operating Instructions UniTech Perfect

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

User Instruction Manual

USER INSTRUCTIONS FOR 0.25 LITRE MINI DEHUMIDIFIER - MODEL NO. DHMD025

Operation Manual. Pond Pump Series HJ and CQP

Operation Manual. Trash Water Pump ARTICLE Image similar

Polti S.p.A. reserves the right to change equipment or accessory specification without prior notice.

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

Installation & Operators Manual. The Classeq Pass Through Range

CONTENTS 1 SAFETY INSTRUCTIONS.. 2 FEATURES AND OPERATION... 3 PARTS LIST AND INSTALLATION. 4 CONTROL PANEL AND SETTINGS...

MW401 Integrated Dishwasher

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage.

WC370 Integrated Intelligent dishwasher Manual for Installation, Use and Maintenance

TTV 4500 / TTV 4500 HP / TTV 7000

WC600 Integrated Dishwasher Installation, Use and Maintenance

Moisture inside the drum is due to final testing.

Zip InLine. Models CEX-O & CEX-U Issued August Installation, Maintenance and User Instructions

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

KB 3030B. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

Operating Instructions

WELCOME IMPORTANT SAFEGUARDS

20 LITRE DEHUMIDIFIER

HSGM Heißschneide-Geräte

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

WET & DRY WORKSHOP VAC

WC141 Integrated Dishwasher Installation, Use and Maintenance

Heated Display Merchandiser. Instruction Manual. Models: GC875-A / GC876-A / GC877-A

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

IMPORTANT SAFETY INSTRUCTIONS

I N S T R U C T I O N S

Fundamental safety warnings

OPERATING MANUAL UG5000W SERIES SOLVENT AND WATERBORNE SPRAY GUN CLEANERS MODELS UG5000W UG5500W UG5000EW UG5500EW CAUTION RIGHT TANK (UM120W)

RONDA 2-58 Duo Heavy Duty Industrial Vacuum Cleaner For Liquid Filtration and Transport

SPID play detector date: 07/2006 Manual date:

K M. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

Manual for installation, use and maintenance MW200. Integrated Slimline Dishwasher. year. parts + 1 year labour guarantee.

AUTOMATIC MODULAR ICE-CUBE MAKER

CZ51202 Larder fridge

WARNING: Ensure that the UV is switched off at the mains before you attempt to conduct any type of maintenance on the EazyPod Complete.

FC 5 FC 5 Premium. OPERATOR MANUAL Floor Cleaner...2 MANUAL DE USUARIO Limpiador de piso...22 MANUEL D UTILISATION Nettoyant pour sols...

SASE BULL 240C. Dust Collection System Manual

BLOW DRY & GO HAIR KIT

Hand Dryer Installation & User Manual

Airbrush Compressor & Vacuum Pump AS20W ARTICEL 34202

Safety and Instruction Manual

STRIP CUT PAPER SHREDDER

SAFETY AND OPERATING MANUAL

WATER BOILER METOS MARINE WKI MG MW,

12L Dehumidifier Model: HG00923

Sip Vacuum Cleaner 1400/35 Wet & Dry

Multifunction. Vax model number:

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

KETTLE WK 6330 ENGLISH

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

Washing. Detergent drawer with compartments I, II, Drum. Control panel. Washing machine door. Service flap for detergent solution pump. Select Start.

EHA Hoffmann International GmbH

INSTRUCTION MANUAL (English version) Water still

Transcription:

AS 50 operating manual with Rotoclean roller cleaner 2013 Edition CONTENTS Important Safety Notes...... Page 1 CE EG Certification of conformity... 2 1. Technical specifications... 3 2. Installation 2.1 Set-up and safety check... 3 3. Operation and function 3.1 Cleaning of tools...... 4 3.2 Water purification... 4 3.3 Disposal of waste solids...... 5 4. Maintenance 4.1 Transportation...... 5 4.2 Storage... 5 4.3 Frost protection... 5 4.4 Maintenance..... 5 7. Spare Parts List., 6. AS 50 operating manual, 2013 Contents

Important Safety Notes: Please read this manual before using your Bristol - Aqua Service AS50 This manual contains useful information and instructions for the installation, operation and maintenance of this unit which if correctly followed will ensure safe and secure long term use. This manual should be read by all operating personnel before and after installing this unit Always keep the manual in convenient location for ease of reference. Qualification and Training of Operating Staff: The personnel responsible for operation and maintenance of this product must have appropriate training. The main operator has to ensure that the areas of responsibility and supervision regarding use of this product are strictly organised. Appropriate instructional training must be offered to all members of staff who are to work with this equipment. If necessary, instructional courses can be held by the manufacturer or vendor of the product upon request. The operator must ensure that all members of the operating staff have fully understood the entire content of this manual. Limitation of Liability: Non-observance of the safety instructions in this manual may result in personal injury, damage to the equipment or the environment. The manufacturer is not responsible for any direct or consequential damage resulting from the disregard of the instructions in this manual. Safety at Work: All safety instructions in this manual and all local regulations regarding accident prevention and plant regulations regarding work and safety must be observed. Power Supply: This device must only be connected to suitable power supply system which has been installed by a professional electrician and complies with the current electrical installation regulations. It is recommended this device is connected to a power supply with a suitable earth leakage switch, which will terminate the power supply should a fault occur. ***** If you are in any doubt, please consult a professional electrical installer. AS 50 operating manual, 2013 Page 1

CE Attestation of EU conformity for Product: System for tool cleaning and water recycling Type: AS 50 Technical specifications: 23OVAC 50Hz 0,88kW We, Aqua - Service Industriewasserrecycling GmbH Josef-Burger-Strasse 1 D - 79215 Elzach hereby certify that the above mentioned product, on account of its design and construction, complies with the following European standards: Maschinenrichtlinie (8913921ewg) EG - Niederspannungs - Richtlinie (731231ewg) EG - Richtlinie elektromagnetische Verträglichkeit (8913361ewg) Compliance of the above mentioned product with the above mentioned directives is proven by complete fulfilment of the following standards: Harmonised European standard specifications: DIN EN 292-1 DIN EN 292-2 National standard specifications: DIN EN 60204-1 DIN EN 60335-1 DIN EN 60555 DIN VDE 0106 Any unauthorized alteration of this product voids this attestation. Elzach / Germany, 2011 Heinrich Kunz President AS 50 operating manual, 2013 Page 2

1. Technical Data: Type: AS 50 Voltage AC 230 V dimensions Depth 650 mm Frequency 50 Hz Width 630 mm Power 0,88 kw Height 1280 mm Mains fuse 10 A Weight (w/o accessories) 25 kg Filling amount Clear water container and process container approx. 50 litres, Filter box approx. 60 litres 2. Installation 2.1 Set-up and Safety Check Place the AS 50 on a firm base and secured as required if to be in a fixed position. The AS 50 should be positioned so it that it can be accessed from the front and at rear for draining Run mains cords and water hose to the outside of the unit using the provided openings at rear. The spray gun requires unclipping from its hose thread through aperture and feed to top of unit. Replace spray gun and secure in hands free clip above wash up area. Take the pneumatic hose off the pneumatic footswitch (push fit) and run it too outside / front of AS50 using the opening provided at rear Plug the 2 x earthed mains plugs into an approved mains socket with 230V/ 50 Hz/ 10 A FI* (* differential switch with min. 30 ma in 30 ms ) Position the pneumatic foot switch so that it can be easily accessed from the front of the unit. Fill base 50 Lt. reservoir with fresh water, (water level is approx. 1 cm below container edge). N.B. Before first operation of the AS50: Prime the pump with fresh water Remove black vent screw from top / front of pump housing Fill with water until chamber is full and overflowing Replace black vent screw and tighten (do not over tighten) WARNING!!! An incompletely de-aerated pump may affect operation of the system. Dry running of the pump leads to pump damage!! Filters: For best filtration results we recommend the simultaneous use of two filter bags Insert filters into filter basket as follows: Fit Grey felt filter first followed by fine White. See Specific install and User instruction sheets for full details AS50 operating manual, 2013 Page 3

3. Operation WARNING!! Do not use the AS50 for Solvent based Paints and Lacquers, Do not use unit to dispose of old paint and coatings - The AS50 is not a bin!! 3.1 Cleaning of Tools Ensure that the Red gate valve closed, otherwise untreated water will run straight through to filter Spray Gun: Operation is by pressing the footswitch: the pump draws the water out of the clear water reservoir and delivers it to the hands free spray gun via high pressure hose. Press spray gun lever to start the water jet, adjust spay volume and pattern to suit. Roller cleaning: Place paint roller behind the splash guard with handle to bottom. By opening the control valve above and press foot switch, the water will flow from the jet rail. Moving the roller in front of water jet will cause the roller to spin and the paint to be spun out of roller cover. With practice the Sweet spot for attaining best roller rotation will be found. Turning the roller 180º behind splash guard enables the complete cleaning of of the roller. When all paint has been removed release foot switch and allow roller to spin dry. Before cleaning paint rollers, remove as much paint as possible. After cleaning roller cover remove from the roller cover from frame and rinse both under spray gun to complete cleaning process. The cleaning process can continue until the reservoir water has transferred to the upper processing sink. When the water level in the clean water reservoir has reached its minimum level the pump ** will automatically cut out and water purification of the dirty waste water in the process tank needs to be undertaken before proceeding. ** If using high pressure roller cleaner at this point the pump can sometimes become vented and require repriming. 3.2 Water Purification (Flocculation) ATTENTION!! Before starting the purification process make sure that the processing tank contains no particles larger than 3 mm. Do not start the agitator before the processing container is completely filled as air not water is drawn into the agitator and will damage impeller. Start the agitators by pressing button on the left side of the filter box. The control lamp illuminates to indicate that the agitator is stirring the dirty water. While the agitator is running, disperse required fission powder onto surface waste water with supplied scoop. The amount of flocculation powder aquafloc 7 is determined by the type and density of paint being treated. AS50 has 50 litres water, allowing 1% paint dispersion requires 70 grams Fission powder - ¾ scoop The amount of flocculation powder aquafloc 7 is determined by the type and density of paint being treated. Ensure the flocation powder is thoroughly mixed into the water to avoid clumping. The built-in timer switch automatically turns off the agitator after approx. 15 min. You can use the push-button to manually turn the agitator on or off at any time. Leaving the water to stand for approx.10 mins, the sediment and water will be seen to separate and the water appearing totally clear with the flocked solids laying in base of sink. If not completely clear repeat the cleaning process as described above with a further 50 grams of fission powder Experience will in time guide your purification / agitation times and volume of flocculation powder required AS 50 operating manual, 2013 Page 4

3.3 Disposal of Sludge Make sure the filter is correctly positioned beneath the drain outlet Insert special raised plug into the central drain point and slowly open the associated red handled gate valve on front of unit. By doing this it will ensure the majority of clear water drains off first and returns more quickly through filter and into base reservoir. When water has drained to top of raised plug remove plug. This will allow the remaining water and flocated sludge to run off into filter box. When fully drained remove the remaining residual sludge and clean all paint deposits from the process sink with spray gun and a cleaning brush to complete process. Ensure all flocated paint residue is washed down the drain. It is good practice to thoroughly rinse the agitator unit via the small hole in right hand side of unit. Finally give sink a wipe down with a clean damp cloth. If this method is followed it will not only sped up the filtration process but gain the highest possible filter capacity. Before starting the next cleaning process, check water level for loss due to evaporation and top up reservoir. WARNING!! Under no circumstances should the pump be allowed to run dry! After 3-4 cleaning processes exchange top white filter for a fresh one. Removed filter can be left to dry out, sludge should be then be shaken out and disposed of as solid waste, observing the official regulations. The white filter can then be rinsed, dried and reused 4 Transportation, Care and Maintenance 4.1 Transportation The AS 50 is equipped with heavy duty castor wheels making unit extremely portable. Impacts on the housing should be avoided, especially at temperatures below 5º C when material becomes more brittle and has higher risk of breakage. The AS 50 is made of high quality polyethylene. This material has outstanding features in resistance to solvents and chemicals. The mechanical stability is designed for professional and industrial use. 4.2 Drainage Periodically the water should be replaced. Place AS50 adjacent to a suitable floor drain. At rear of unit rotate drain pipe downwards and remove plug to allow water to run away, unit should be tipped backwards to remove last of the water. Replace plug and return drain pipe to vertical position.. Alternatively unit can also be drained by using spray gun into an adjacent sink or drain, last vestiges can be removed using discharge pipe as above 4.3 Frost Protection Store and operate the unit only in a frost-protected environment. If the storage location is not frost-free, all residual water must be completely removed from main unit, pump and all accessories. 4.4 Maintenance The AS 50 has been designed for long lasting problem free use. To maintain functionality a minimum of maintenance is required, thorough cleaning after every process and the occasional cleaning of the impeller is usually sufficient. All plastic parts need to be cleaned with water and soft brushes. Don t wait until paint has becomes completely dry!! AS 50 operating manual, 2013 Page 5