Installer: (Name, address, telephone)

Similar documents
Installer: (Name, address, telephone number)

Installer: (Name, address, telephone)

Installer: (Name, address, telephone)

Installer: (Name, address, telephone number)

Installer: (Name, address, telephone)

Installer: (Name, address, telephone number)

MOTOR FOR SLIDING GATES SERIE GR8 220V

Risk assessment and analysis for swing gates

GATE INFORMATION PACK

GUIDE TO INSTALLATION

Ditec DOR Folding doors operator

The New EMC Directive 2004/108/EC

NORMS AND REGULATIONS FOR AUTOMATIC DOORS & ENTRANCE CONTROLS

Ditec QIK80EH Electromechanical barrier (Translation of the original instructions)

dhf General Information Automated Gates Guidance for enforcement bodies

Professional Instruments. Safe Gates. Regulations overview Safety for gates and doors Notice on the EN Certification

The New EMC Directive 2004/108/EC

CE marking of industrial doors under the CPR Michael Skelding, Secretary and General Manager Door and Hardware Federation

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

HULME MARTIN HEAT SEALERS

Guide to Gate Safety Legislation & the Machinery Directive

Domestic Garage Doors

Guide to Gate Safety Legislation & the Machinery Directive. In Association with:

HULME MARTIN HEAT SEALERS

Sliding Gates White Paper 1 Sliding Gate Safety Third Edition

Council Directive 93/68/EEC of 22 July 1993 amending Directives

ST1. Mod. USE AND MAINTENANCE MANUAL

The plant meets the requirements of the current FSS 5 Checklist for Vessel Process Plants

DHF Introduction DHF 2

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

Monitored Pneumatic Valves On Series Ported Manifold

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

JBCE input for the RoHS FAQ document

CE Marking and Technical Standardisation

Gas Appliances Directive - Advisory Committee. Comité Consultatif de la Directive Appareils a Gaz

½ Monitored Pneumatic Valves On Series Ported Manifold

Guide to gate safety legislation and standards

Your Lifeline Vi+ home unit. Your MyAmie pendant

51AKS I S O OWNER S MANUAL

Motorised swing doors User manual (translation of the original instructions) IP2225EN

2. General information Page Warnings Page Technical characteristics Page Installation Page Front panel Page 7

ISIS SAFETY SYSTEM Installation guide

Ropox Bathtub. Keep this manual with the product at all times! User Manual & Mounting Instructions PDF 6128 /

IMPORTANT SAFETY INFORMATION

Health & Safety and Installation guide

S I M P L Y C E INTRODUCTION TO CE NORMS AND STANDARDS FOR DOORS AND GATES TWO THOUSAND EIGHTEEN

CE marking & your legal obligations

Electromagnetic Locking Devices Performance Requirements

Forced draught gas burner

TECHNICAL AND USER REQUIREMENTS FOR PERSONAL ALERT SAFETY SYSTEMS

Ditec DAS107PLUS User Manual IP2270EN.

HR 601 C A AUS. ENGLISH Instructions for use Page 2

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Standards in Security Shutters & Fire Shutters (UK & USA)

Transition from GAD to the GAR July,

Valve Manufacturers Association of America

Operations Manual VCC

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

Role of CE Marking in the Placing on the Market of Electronic Components

Health & Safety, Use & Care and Installation guide. Οδηγ ς Υγείας, και Ασφάλειας, Χρήσης και Συντήρησης

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Additional deviations may possibly be found if a complete type test is carried out on the product.

PERSONAL CUEING DEVICE MODEL NO. BDAAU100 INSTRUCTION MANUAL.

On Electromagnetic Compatibility

Basically, the instruction handbook shall contain the following information:

SHORT WAVE INFRARED PANEL DRYER

SWARCO TRAFFIC SYSTEMS GMBH. TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00

Kitchen Appliance Lift INSTRUCTION MANUAL

1. Terms defined in the Construction Products Regulation (CPR)

INTERNATIONAL STANDARD

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Installation manual VISIO HERMÉTICO

EU legislation and requirements for doors and gates Safety guide to power operation and Bircher Reglomat sensors

SAFETY STANDARDS & SOLUTIONS MATERIAL HANDLING & INTRALOGISTICS

GECE cm touch control ceramic hob. GECE cm touch control ceramic hob

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

½ Monitored Pneumatic Valve Patented Technology

Operations Manual VCS/VCR/VLS

COMPACT AND LIGHTWEIGHT FOR OUTDOOR CLEANING

Guideline Construction Products Regulation (EU) 305/20122

Ditec VALOR R Sliding door installed in escape routes (Original intructions)

INSTRUCTIONS AND ADVICE FOR THE USE, INSTALLATION AND MAINTENANCE OF BUILT-IN ELECTRIC HOBS

Sensero-868/915 AC, Sensero-868/915 AC Plus Nr , , ,

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

Topvex SR03, SR04, SR06 Compact Air Handling Unit

INSTRUCTIONS OF POLLEN DRYER 4 KG

BriskHeat NDT Kit for Elevator Inspection

SAFETY AND OPERATING MANUAL

***** 2. Rev.1 is to be uniformly implemented by IACS Members from 1 July 2004.

Declaration of conformity maintenance record. No Revised date Contents Reasons Approval

GREEN LIFT SYSTEM USE MANUAL WITH PERMANENT MAGNETS * EN* SYSTEM TYPE: q GLPM MRL 1:1 q GLPM MRL 2: EN.

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Installation instructions

BACE cm ceramic electric cooktop GECE cm ceramic electric cooktop

Space Saver. Installation and user manual. Issue 001 March 2018 ENGLISH UK IRL SmithsEP.co.uk. Issue March 2018 smithsep.co.

INSTRUCTIONS FOR USE. To make the most of your new oven, read the user's instructions carefully and keep them on hand for consultation in the future.

This second part of the lesson & is dedicated to EMC legal aspect and standards.

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

Grafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark. Website: Phone:

Transcription:

Installer: (Name, address, telephone) UNAC GUIDE No. 4 FOR THE MOTORISATION OF SECTIONAL GARAGE DOORS IN ACCORDANCE WITH MACHINERY DIRECTIVE 98/37/EEC AND THE APPLICABLE PARTS OF STANDARDS EN 13241-1, EN 12453, EN 12445 With this publication UNAC sets out to inform and assist installers in applying the specifications of the directives and of European standards concerning the safe use of motorised gates/doors. It should be noted that those who sell and motorise an existing manual door/gate become the manufacturer of the motorised door/gate machine and must prepare and keep the technical file, as laid down by Annex V of the Machinery Directive (98/37/EEC). The technical file must contain the following documents: Assembly drawing of the motorised door/gate (usually included in the installation manual). Electrical connections and control circuit diagrams (usually included in the installation manual). Risk analysis including (as indicated on the following pages): the list of the essential requirements as indicated in Annex I of the Machinery Directive; the list of the risks presented by the door/gate and the description of the solutions adopted. They must also keep the manuals for installation and maintenance of the door/gate and of the components. Prepare the operating instructions and general warnings for safety (if necessary integrating those in the manual for installation of the door/gate) and give the user a copy. Compile the proof book and give the user a copy (see facsimile in Annex 1). Draft the EC declaration of conformity (see facsimile in Annex 2) and give the user a copy. Fill in the label or plate with CE marking and attach it to the motorised door/gate. N.B. The technical file must be held and made available to the competent national authorities for at least ten years from the date of construction of the motorised door/gate. Note also that, as from May 2005, the manufacturer of a new door/gate (both manual and motorised) must observe the procedure for the CE marking pursuant to the Construction Products Directive (89/106/EEC), as indicated in annex ZA of the standard EN 13241-1. This procedure involves the manufacturer: setting up and maintaining internal production control; having a notified body carry out the initial type tests referring to the applicable characteristics indicated in Annex ZA of standard EN 13241-1. N.B. UNAC is preparing guidelines dedicated to the correct application of the Construction Products Directive (89/106/EEC). Risk areas of the sectional garage door (Figure 1) The information given was drafted and checked with the utmost care, nevertheless UNAC declines all responsibility for any errors, omissions or inaccuracies due to technical or graphical requirements. UNAC points out that this guide does not replace the content of standards which the manufacturer of the motorised door/gate must observe. - 1 - UNAC Guide No. 4 - May 2005

KEY TO THE MECHANICAL RISKS CAUSED BY MOVEMENT Pursuant to the Machinery Directive: Danger zones refer to any zone within and/or around machinery in which an exposed person is subject to a risk to his or her health and safety. Exposed person refers to any person wholly or partially in a danger zone. Impact Crushing Impact Crushing MINIMUM LEVEL OF PROTECTION OF THE MAIN EDGE Type of use Type of actuation controls Informed users (private area) Informed users (public area) Uninformed users Hold-to-run control Pushbutton control Pushbutton control with key Hold-to-run control not possible Impulse control with door visible Limitation of forces, or presence Limitation of forces, or presence Impulse control with door not visible Automatic control (e.g. timed closure control) Shearing Dragging Cutting Hooking Limitation of forces, or presence Limitation or forces and ANALYSIS OF THE RISKS AND CHOICE OF SOLUTIONS IN ACCORDANCE WITH THE MACHINERY DIRECTIVE 98/37/EEC AND THE STANDARDS EN 13241-1, EN 12453, EN 12445 The risks listed below follow the sequence of the installation process. These risks are those which are commonly present in motorised doors/gates systems. According to the various situations, consideration therefore has to be made of any possible additional risks and exclude those which are not applicable. The solutions to be adopted are those indicated by the standards mentioned above; in the case of risks not dealt with, the safety integration principles indicated by the Machinery Directive (Annex 1 1.1.2) have to be applied. MD ANN. 1 1.3.1 1.3.2 1.5.15 Mechanical, structural and wear risks. [1] Loss of stability and break-up. [2] Tripping. Check the solidity of the structure installed (slide guides, architrave, counterweights, balancing springs, etc.) in relation to the weight and forces generated by the motor. Attach the motor stably using adequate materials. If available, check the content of the EC declaration of conformity of the manual gate. If necessary, carry out the structural calculation and attach it to the Technical File. Check that possible breakage of the systems of suspension and/or balancing does not create hazardous situations, or the presence of anti-falling systems. Check that any thresholds higher than 5 mm are visible, indicated or shaped. - 2 - UNAC Guide No. 4 - May 2005

MD 1.3.7 1.3.8 1.4 Mechanical risks caused by the movement of the gate (see references in Figure 1). CAUTION If the door/gate is used solely with hold-to-run controls (and meets the requirements of the standard EN 12453), the danger points listed below do not have to be protected. CAUTION If protective devices are installed (in accordance with the standard EN 12978) which prevent in all cases contact between the moving leaf and persons (for example photoelectric barriers, presence sensing devices), it is not necessary to measure the operating forces. [3] Impact and crushing on the lower closing edge (Figure 1, risk A). Measure the closure forces (by means of the special instrument required by the standard EN 12445) as illustrated. Check that the values measured by the instrument are below those indicated in the graph. Carry out the measurements in the following points: L = 200 mm from the lateral edges and at midheight; H = 50 mm, 300 mm, and at maximum opening of the leaf minus 300 mm (max 2500). N.B. The measurement should be repeated three times in each point and the average value considered. The graph indicates the maximum values of the dynamic, static and residual operating forces in relation to the various positions of the leaf. If the values of the forces are higher, install a protective device in accordance with the standard EN 12978 (for example a sensitive edge) and repeat the measurement. N. B. The dynamic force can be reduced, for example, by reducing the speed of the leaf or using a sensitive edge with high elastic deformation. Force Dynamic force IMPACT Static force CRUSHING time - 3 - UNAC Guide No. 4 - May 2005

MD considered [4] Impact and crushing on the main closing edge (Figure 1, risk A). Install a pair of photocells (recommended height 200 mm) so as to sense the presence of the test parallelepiped (height 300 mm), positioned as illustrated. In the case of a sectional door installed in a private home and which does not open onto a public area, and does not operate with timed automatic closure, the photocell is not compulsory. To avoid impact with trucks and jeeps that are stopped in the transit area, a further couple of photocells should be installed at a height of 1000 mm. To reduce further the possibility of impact in the area of closure of the door, a pair of photocells can be installed (recommended height 200 mm) on the opposite side. N.B. The test specimen for presence sensing is a parallelepiped (700 x 300 x 200 mm) having 3 faces with a light and reflective surface and 3 faces with a dark and opaque surface. [5] Crushing, dragging and cutting on the secondary opening edge (Figure 1, risk B). Specimen for presence sensing Check that the height of the opening space is > 2500 mm. or Attach protective devices that prevent insertion of hands (for example a rubber strip), [6] Danger of lifting. Check that the surface of the door is smooth and therefore without points of hooking or cutting; or Install protective devices that sense the presence of a person lifted by the leaf before reaching the danger area (e.g. by installing one or two pairs of photocells); or Check that the door is not able to lift a weight of 20 kg (or 40 kg in the case of doors installed in private areas). [7] Impact, crushing and cutting on the side slide guides of the mobile leaf (Figure 1, risk C) The side slide guides (required for operation of the system) must have an opening reduced to a minimum and must not have sharp edges. N.B. Insertion of the hands in the slide guides is however possible. It is preferable to attach the appropriate signs at the slide guides. [8] Pass door installed in the sectional door (Figure 1, risk E). Check that the movement of the sectional door cannot take place if the pass door, which may be installed in it, is not completely closed. [9] Dragging, hooking and cutting due to shaping of the mobile leaf (Figure 1, risk D). Eliminate or protect any sharp edges, projecting parts etc. (for example by means of covers or strips in rubber). N.B. Any gaps present must not allow the insertion of fingers (< 8 mm). - 4 - UNAC Guide No. 4 - May 2005

MD 1.5.1 1.5.2 Electrical and electromagnetic compatibility risks [10] Direct and indirect contacts. Dispersion of electrical energy. Use CE-marked components and materials pursuant to the Low Voltage Directive (73/23/EEC). Carry out the electrical connections, connection to the mains, earth connections and relevant checks, in accordance with current regulations and as indicated in the installation manual of the drive unit. 1.5.10 1.5.11 [11] Risks relating to electromagnetic compatibility. Safety and reliability of drive unit and control and safety devices. N.B. If the electrical supply line is already set up (via both a socket and a connector block), declarations of conformity to Italian law no. 46/90 are not necessary. Use CE-marked components pursuant to the EMC Directive (89/336/EEC). Carry out the installation as indicated in the manual for installation of the drive unit. 1.2 1.5.3 1.2.3 1.2.4 [12] Safety conditions in the event of malfunctioning and power failure. [13] Energy types other than electrical energy [14] Actuation and disabling of the drive unit. [15] Power supply switch. Use drive units which comply with the standard EN 12453 and safety devices which comply with the standard EN 12978. Check that the door does not perform hazardous movements (in the case of breakage of the suspension system, the door must not fall more than 300 mm). If hydraulic drive units are used, they must comply with the standard EN 982; or if pneumatic drive units are used, they must comply with the standard EN 983. Check that, after a fault or power failure, the drive unit restarts safely without creating hazardous situations. Install an omnipolar switch for electrical insulation of the door/gate, in accordance with current laws. This switch must be positioned and protected against accidental or unauthorised actuation. - 5 - UNAC Guide No. 4 - May 2005

MD 1.2.5 1.5.14 [16] Consistency of controls [17] Risk of trapping. Install the controls (e.g. key selector) so that the user is not in a danger zone, and check that the meaning of the controls has been understood by the user (for example the function selector). Use CE-marked radio controls pursuant to the R&TTE directive (1999/5/EEC) and complying with the frequencies admitted by the laws of each individual country. Install a device for release of the drive unit that allows manual opening and closure of the leaf with force no higher than 225 N (for doors/gates in residential areas) or 390 N (for doors/gates in industrial or commercial areas). Supply the user with the means and instructions for the release operations. Check that operation of the release device is simple and does not create additional risks. 1.2.4 1.7.1 1.7.2 [18] Emergency stop. Integration principles for safety and information. [19] Signalling equipment. [20] Warnings. If appropriate, install an emergency stop control in accordance with the standard EN 418. N.B. Make sure that the emergency stop does not introduce additional risks, aborting operation of the safety devices installed. A flashing light should be installed, in a visible position, to indicate movement of the leaf. Traffic lights can be installed to control vehicle traffic. Reflectors can also be attached to the leaf. Attach all those signs or warnings considered necessary for indicating any unprotected residual risks and to indicate any foreseeable improper use. 1.7.3 [21] Marking. Attach the label or plate with the CE marking and containing at least what is shown in the illustration. Automatic Gate Manufacturer (name address): Type of gate: Identification number: Year of manufacture: 1.7.4 1.6.1 1.1.2 [22] Operating instructions. [23] Maintenance. [24] Unprotected residual risks. Consign to the user the operating instructions, safety warnings and EC declaration of conformity (cf. facsimile in Annex 2). A maintenance plan has to be drawn up and implemented. Check on the proper working of the safety devices at least every 6 months. Record the work carried out in the proof book in accordance with the standard EN 12635 (cf. facsimile in Annex 1). Inform the user in writing (for example in the operating instructions) of any unprotected residual risks and foreseeable improper use. - 6 - UNAC Guide No. 4 - May 2005