Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Similar documents
Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CEN/TC 33 - Doors, windows, shutters, building hardware and curtain walling. EN 107:1980 Methods of testing windows - Mechanical test 89/106/EEC

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Annex of the certificate (Page 1/7) Accreditation Scope

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

best practice guide BS EN 14846: 2008 Electromechanically operated locks & striking plates to in association with

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Mechanically operated locks and locking plates

SKG-IKOB Certificatie B.V. Trading under the names SKG, IKOB-BKB and SKW Certificatie

GUIDELINIE ECB S R10. March European Certification Body GmbH

Contents EN :2006+A2:2016 (E)

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

FLAMEBREAK. Rev.D Mechanical Performances - General: TM

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Panic & Emergency Exit Hardware

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Electromagnetic Locking Devices Performance Requirements

For more information on Abloy UK visit EXIT HARDWARE

Panic and Emergency Exit Devices

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

Rim Locks. Rim Locks Index. Standards & Approvals. Keying Groups. Keys

Specifying Security Hardware for Doors

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Electromagnetic Locking Devices

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

EN 1155:1997 TESTS OF : PERKO R106 FS CONCEALED FIXED ELECTRICALLY POWERED FREE SWING DEVICES FOR SWING DOORS. Leopold Street, Birmingham.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Market Introduction DORMA. Modular Panic Hardware System PHA 2000 / PHB 3000

PANIC EXIT HARDWARE DX-500 Serie

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

best practice guide BS EN 12320: 2001 Padlocks & padlock fittings to in association with Permission to reproduce extracts from BS EN 12320: 2001

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Guide to interpreting Markings for Single Axis Fire Doors Hinges

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Newstar Locks. NEWSTAR form and function for life. BS Range. London Fire Brigade Range

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

HD72 Euro Profile Mortice Lockcase. The high performance lock that goes beyond the standard. ASSA ABLOY, the global leader in door opening solutions

A GUIDE TO LOOKING AFTER YOUR WINDOWS AND DOORS

A guide to looking after your windows, doors and conservatories. spectus n. look, appearance, aspect

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

This document is a preview generated by EVS

Window & Door Security

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Inspiration Aluminium Bi-Folding Doors

FREE. Health Check. Free Phone A guide to looking after your windows, doors and conservatories

CERTIFICATE OF APPROVAL No CF 5657 UNION ARCHITECTURAL HARDWARE

DOOR SETS. Versatile with a range of options, they can be tailored to suit your needs.

Designed to provide immediate escape, first time, every time

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Best practice guide. Door coordinator devices to BS EN in association with. Association of Building Hardware Manufacturers

Window Types. TD-005 July 29, Window Types 101. Casement / Projected

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Standards in Security Shutters & Fire Shutters (UK & USA)

PHA Panic Hardware for timber doors

Operating, cleaning and maintenance guide

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Hospitality Vertcial Market Our Ref: ABC123

Controlled Door Closing Devices

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

The. Specifier s. First Choice

Product Maintenance and User Guide

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Transport Vertcial Market Our Ref: ABC123

CE marking of industrial doors under the CPR Michael Skelding, Secretary and General Manager Door and Hardware Federation

Code of Practice: Hardware for Fire and Escape Doors. Issue No.2 June 2006 THE GUILD OF ARCHITECTURAL IRONMONGERS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Ironmongery Performance Specifications

Inspiration Aluminium Bi-Folding Doors

F O C U S D O O R C L O S E R S

Panic Exit Devices. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

High Security Locking. Product Catalogue

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Operation & maintenance information. for windows, doors and conservatories

Code of Practice: Hardware for Fire and Escape Doors

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Commercial Vertcial Market Our Ref: ABC123

Fapim spa. Dutch Buildings Decree SKG ENG. Building hardware

About the Instructor & Presenter:

ABLOY EFEND. New name for security

The Association for Specialist Fire Protection

Inspiration Aluminium Bi-Folding Doors. HGW Solutions - Bifold Brochure 2018.indd 1 21/05/ :50:52

Hardware for Sliding Doors & Folding Doors

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Education Vertcial Market Our Ref: ABC123

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Healthcare Vertcial Market Our Ref: ABC123

Newstar Door Closing Devices & Accessories

Loss Prevention Standard

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Transcription:

Schedule of ccreditation United Kingdom ccreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ccredited to Unit 3 Wednesbury One Black Country New Road Wednesbury West Midlands WS10 7NZ Contact: Mr I Keeling Tel: +44 (0)121 506 7500 E-Mail: ian.keeling@exova.com Website: www.exova.com below Laboratory location: s covered by the Organisation and their relevant activities details ctivity code ddress Unit 3 Wednesbury One Local contact Mr I Keeling Laboratory testing Black Country New Road Wednesbury West Midlands WS10 7NZ Site activities performed away from the location listed above: details ctivity code ll locations suitable for the activity listed Local contact Mr I Keeling Performance tests on industrial, commercial and garage doors and gates B ssessment Manager: PJ1 Page 1 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to DETIL OF CCREDITTION PIVOTED DOORS, WINDOWS and SSOCITED FURNITURE flexible scope including: Cycling tests Measurement of operating forces Loading tests Documented In-House Methods developed using E-E-QU-MN001-Section 5 Local ppendix 2 and any combination of the above, within the ranges of: mass force torque 200 kg 50 kn 150 Nm ccreditation includes the provision of opinions and interpretations for all tests listed below, except those carried out on industrial, commercial and garage doors and gates, and automotive trim and components. BUILDING HRDWRE - cylinders for locks Key strength BS EN 1303:2015 Durability tests BS EN 1303:2015 Corrosion resistance and temperature Corrosion resistance (Test of operation at extremes of temperatures) Operation of the security mechanism Torque resistance of plug and/or cylinder BS EN 1303:2015 BS EN 1303:2015 BS EN 1303:2015 BS EN 1303:2015 Resistance to drilling BS EN 1303:2015 Resistance to attack by chisel BS EN 1303:2015 ssessment Manager: PJ1 Page 2 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to BUILDING HRDWRE - cylinders for locks (cont d) Resistance to attack by twisting BS EN 1303:2015 Resistance to attack by plug/cylinder extraction BS EN 1303:2015 BUILDING HRDWRE - locks and latches - mechanically operated locks, latches and locking plates Return force of latch bolt Resistance to side load on latch bolt Torque to operate deadbolt Strength of normal latch action and stops Torque resistance of rim lock with lockable handle/knob Durability of latch action without force applied Durability of latch action with force applied Durability of deadbolt mechanism Durability of locking snib mechanism Closing force Corrosion resistance Operation at extremes of temperature Torque resistance of knob or lever handle on bored lock and latch sets Torque resistance of knob or lever handle on rim night latch ssessment Manager: PJ1 Page 3 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to BUILDING HRDWRE - locks and latches - mechanically operated locks, latches and locking plates (cont d) Resistance to side load on deadbolt Resistance to drilling and side load on deadbolt Deadbolt projection Resistance to end load Resistance to end load with drilling Resistance to pulling of hook/claw bolt Resistance to disengaging of hook/claw bolt Resistance to forcing of locating device in sliding door locks Resistance to pulling off of knob on bored lock and latch set Resistance to end load on box protected locking plate Resistance to side load on locking plate Resistance to pulling on locking plate Resistance to lifting force on locking plate Protection against removal from door Strength of key Manual locking ssessment Manager: PJ1 Page 4 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to BUILDING HRDWRE - locks and latches - mechanically operated Manual locking with intermediate locking positions locks, latches and locking utomatically locking deadbolt plates (cont d) utomatically locking latch bolt Torque to withdraw the latch bolt with key Torque to withdraw latch bolt with handle Strength of bolt actions Minimum follower restoring torque Non-interpassing of keys with just one interval differ Operation time for locking and unlocking Resistance to side load on latch BS EN 14846:2008 BS EN 14846:2008 Torque to operate deadbolt BS EN 14846:2008 Strength of normal latch action and stops Torque resistance of lockable follower Durability of mechanical latch action without force applied Mechanical latch action durability with a force applied Durability of latch action or electric strike without force applied electrically operated BS EN 14846:2008 BS EN 14846:2008 BS EN 14846:2008 BS EN 14846:2008 BS EN 14846:2008 ssessment Manager: PJ1 Page 5 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to BUILDING HRDWRE - locks and latches - electromechanically operated locks and striking plates (cont d) Durability of deadbolt mechanism mechanically operated Durability of deadbolt mechanism electrically operated BS EN 14846:2008 BS EN 14846:2008 Closing force BS EN 14846:2008 Corrosion resistance BS EN 14846:2008 Cold BS EN 14846:2008 Dry heat BS EN 14846:2008 Resistance to cyclic humidity BS EN 14846:2008 Security BS EN 14846:2008 Security - electrical function - status indication BS EN 14846:2008 THIEF RESISTNT LOCK SSEMBLIES - key egress - keyless egress - dual mode Return force of latch bolt Resistance to side load on latch bolt BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Torque to operate deadbolt BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Strength of normal latch action and stops BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Torque resistance of rim lock with lockable handle/knob BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 ssessment Manager: PJ1 Page 6 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to THIEF RESISTNT LOCK SSEMBLIES - key egress - keyless egress - dual mode (cont d) Durability of latch action without force applied Durability of latch action with force applied BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Durability of deadbolt mechanism BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Durability of locking snib mechanism BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Closing force BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Corrosion resistance BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Operation at extremes of temperature BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Torque resistance of knob or lever handle on bored lock and latch sets BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Torque resistance of knob or lever handle on rim night latch BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 ssessment Manager: PJ1 Page 7 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to THIEF RESISTNT LOCK SSEMBLIES - key egress - keyless egress - dual mode (cont d) Resistance to side load on deadbolt Resistance to drilling and side load on deadbolt BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Deadbolt projection BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Resistance to end load BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Resistance to end load with drilling BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Resistance to pulling of hook/claw bolt BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Resistance to disengaging of hook/claw bolt BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Resistance to forcing of locating device in sliding door locks BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Resistance to pulling off of knob on bored lock and latch set BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 ssessment Manager: PJ1 Page 8 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to THIEF RESISTNT LOCK SSEMBLIES - key egress - keyless egress - dual mode (cont d) Resistance to end load on box protected locking plate Resistance to side load on locking plate BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Resistance to pulling on locking plate BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Resistance to lifting force on locking plate BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Protection against removal from door BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Strength of key BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Manual locking BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Manual locking with intermediate locking positions BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 utomatically locking deadbolt BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 ssessment Manager: PJ1 Page 9 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to THIEF RESISTNT LOCK SSEMBLIES - key egress - keyless egress - dual mode (cont d) utomatically locking latch bolt Torque to withdraw the latch bolt with key BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Torque to withdraw latch bolt with handle BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Strength of bolt actions BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Minimum follower restoring torque BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Non-interpassing of keys with just one interval differ BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 Key strength BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007:2:2012 BS EN 1303:2005 Durability tests BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007:2:2012 BS EN 1303:2005 Corrosion resistance and temperature BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007:2:2012 BS EN 1303:2005 ssessment Manager: PJ1 Page 10 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to THIEF RESISTNT LOCK SSEMBLIES - key egress - keyless egress - dual mode (cont d) Corrosion resistance (Test of operation at extremes of temperatures) Operation of the security mechanism BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007:2:2012 BS EN 1303:2005 BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007:2:2012 BS EN 1303:2005 Torque resistance of plug and/or cylinder BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007:2:2012 BS EN 1303:2005 Resistance to drilling BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007:2:2012 BS EN 1303:2005 Resistance to attack by chisel BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007:2:2012 BS EN 1303:2005 Resistance to attack by twisting BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007:2:2012 BS EN 1303:2005 Resistance to attack by plug/cylinder extraction BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007:2:2012 BS EN 1303:2005 Security hardware and cylinder test - Part 1 - Part 2 BS 3621:2007+2:2012 BS 8621:2007+2:2012 BS 1:2007+2:2012 PS 24:2007 REPLCEMENT LOCK CYLINDERS and SSOCITED HRDWRE Enhanced security performance DHF TS 007:2014 + 1:2015 LETTER PLTE SSEMBLIES Enhanced security performance DHF TS 008: 2015 incorporating corrigendum No.1 March 2016 ssessment Manager: PJ1 Page 11 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to BUILDING HRDWRE - single-axis hinges Measurements BS EN 1935:2002 Load-deformation BS EN 1935:2002 Overload BS EN 1935:2002 Shear strength BS EN 1935:2002 Endurance BS EN 1935:2002 Corrosion resistance BS EN 1935:2002 BUILDING HRDWRE - lever handles and knob furniture Check of spindle and fastening elements BS EN 1906:2012 xial strength of lock or latch furniture and fastening elements BS EN 1906:2012 Free play and safety BS EN 1906:2012 Free angular movement or misalignment BS EN 1906:2012 Torque of return mechanism BS EN 1906:2012 Durability of mechanism BS EN 1906:2012 xial strength and method of fastening of special safety furniture BS EN 1906:2012 Rotational strength BS EN 1906:2012 Corrosion resistance BS EN 1906:2012 BUILDING HRDWRE - emergency exit devices operated by a lever handle or push pad, for use on escape routes Temperature test Corrosion test Release tests BS EN 179:2008 BS EN 179:2008 BS EN 179:2008 Re-engaging test BS EN 179:2008 Durability test BS EN 179:2008 ssessment Manager: PJ1 Page 12 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to BUILDING HRDWRE - emergency exit devices operated by a lever handle or push pad, for use on escape routes (cont d) buse resistance test - Operating element buse resistance test - Vertical rods BS EN 179:2008 BS EN 179:2008 Security test BS EN 179:2008 Final examination BS EN 179:2008 BUILDING HRDWRE - panic exit devices operated by a horizontal bar, for use on escape routes Temperature test Corrosion test BS EN 1125:2008 BS EN 1125:2008 Release tests BS EN 1125:2008 Re-engaging test BS EN 1125:2008 Durability test BS EN 1125:2008 buse resistance test - Horizontal bar buse resistance test - Vertical rods BS EN 1125:2008 BS EN 1125:2008 Final examination BS EN 1125:2008 BUILDING HRDWRE - controlled door closing devices Operation at extremes of temperature Mechanical performance and durability BS EN 1154:1997+1:2002 BS EN 1154:1997+1:2002 Corrosion resistance BS EN 1154:1997+1:2002 BUILDING HRDWRE - electrically powered holdopen devices for swing doors Settleback at 90 hold open Manual release BS EN 1155:1997+1:2002 BS EN 1155:1997+1:2002 Electrical release BS EN 1155:1997+1:2002 Temperature rise BS EN 1155:1997+1:2002 Opening overload BS EN 1155:1997+1:2002 Durability BS EN 1155:1997+1:2002 ssessment Manager: PJ1 Page 13 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to BUILDING HRDWRE - electrically powered holdopen devices for swing doors (cont d) Continuous hold-open Salt spray BS EN 1155:1997+1:2002 BS EN 1155:1997+1:2002 BUILDING HRDWRE - door co-ordinator devices Overload performance BS EN 1158:1997+1:2002 Manipulation BS EN 1158:1997+1:2002 Waiting position BS EN 1158:1997+1:2002 Durability BS EN 1158:1997+1:2002 Salt spray BS EN 1158:1997+1:2002 BUILDING HRDWRE - for doors, windows, shutters and curtain walling Corrosion resistance - neutral salt spray BS EN 1670:2007 BS EN ISO 9227:2012 INDUSTRIL, COMMERCIL and GRGE DOORS and GTES Force for manual operation BS EN 13241:2003 + 2:2016 Clause 4.2.2 BS EN 12453:2001 BS EN 12604:2000 BS EN 12605:2000 B Safe opening of vertically moving doors Operating forces of power operated doors Resistance to water penetration Resistance to wind load - complete doors - individual or collective elements BS EN 13241:2003 + 2:2016 Clause 4.2.8 BS EN 12604:2000 BS EN 12605:2000 BS EN 13241:2003 + 2:2016 Clause 4.3.3 BS EN 12445:2001 BS EN 12453:2001 BS EN 13241:2003 + 2:2016 Clause 4.4.2 BS EN 12425:2000 BS EN 12489:2000 BS EN 13241:2003 + 2:2016 Clause 4.4.3 BS EN 12424:2000 BS EN 12444:2001 B B ssessment Manager: PJ1 Page 14 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to INDUSTRIL, COMMERCIL and GRGE DOORS and GTES (cont d) ir permeability BS EN 13241:2003 + 2:2016 Clause 4.4.6 BS EN 12426:2000 BS EN 12427:2000 EXTERNL DOORSETS - single and double leaf - single swing - hinged - sliding - folding sliding - inward and outward opening - with or without integral side panels and fanlights Manipulation test Infill medium removal - manual test Infill medium removal - mechanical test Manual cutting test Mechanical loading test Manual check test Soft body impact test Hard body impact test Security hardware and cylinder test - Part 1 - Part 2 BS 6375-3:2009+1:2013 PS 24:2012 Letter plate fixings BS EN 13724:2002 (withdrawn) Clause 6.6.5.1 DOORSETS - single and double leaf - single and double swing - hinged - sliding (single and multitrack) - pivot - folding sliding (single and multi-track) - stable - with or without integral side panels and fanlights Manipulation test Infill medium removal - manual test Infill medium removal - mechanical test Manual cutting test Mechanical loading test Manual check test Soft body impact test Hard body impact test Security hardware and cylinder test - Part 1 - Part 2 PS 24:2016 DOORS Resistance to vertical load BS 6375-2:2009 BS EN 947:1999 Resistance to static torsion BS 6375-2:2009 BS EN 948:1999 Resistance to soft and heavy body impact BS 6375-2:2009 BS EN 949:1999 ssessment Manager: PJ1 Page 15 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to DOORS (cont d) Resistance to hard body impact BS 6375-2:2009 BS EN 950:1999 Resistance to repeated opening and closing BS 6375-2:2009 BS EN 1191:2000 Operating forces BS 6375-2:2009 BS EN 12046-2:2000 Strength of safety devices BS 6375-2:2009 BS EN 948:1999 Documented In-House Method No EX-FI-OP-BH-WL-SOP-055 Closure against obstruction BS 6375-3:2009+1:2013 PEDESTRIN DOORSETS (single and multi-leaf) and WINDOWS groups 1 and 2 Burglar resistance Resistance under static loading Resistance classes 1, 2 and 3 BS EN 1628:2011 BS EN 1627:2011 following the UK Police Service Secured By Design (SBD) interpretive document (Issue 7 Published 27th March 2013) for BS EN 1627:2011, BS EN 1628:2011, BS EN 1629:2011 and BS EN 1630:2011 Burglar resistance Resistance under dynamic loading Resistance classes 1, 2 and 3 BS EN 1629:2011 BS EN 1627:2011 following the UK Police Service Secured By Design (SBD) interpretive document (Issue 7 Published 27th March 2013) for BS EN 1627:2011, BS EN 1628:2011, BS EN 1629:2011 and BS EN 1630:2011 Burglar resistance Resistance to manual burglary attempts Resistance classes 1, 2 and 3 BS EN 1630:2011 BS EN 1627:2011 following the UK Police Service Secured By Design (SBD) interpretive document (Issue 7 Published 27th March 2013) for BS EN 1627:2011, BS EN 1628:2011, BS EN 1629:2011 and BS EN 1630:2011 ssessment Manager: PJ1 Page 16 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to WINDOWS and DOORS Weathertightness BS 6375-1:2015 ir permeability BS 6375-1:2015 BS EN 1026:2016 Watertightness BS 6375-1:2015 BS EN 1027:2000 BS EN 1027:2016 Resistance to wind load BS 6375-1:2015 BS EN 12211:2016 Basic security test BS 6375-3:2009+1:2013 WINDOWS, DOORS and SHUTTERS Calculation of thermal transmittance (U-value) BS EN ISO 10077-1:2006 BS EN ISO 10077-2:2012 BS EN ISO 10456:2007 Clause 6 BS EN 673:2011 WINDOWS Resistance to repeated opening and closing BS 6375-2:2009 BS EN 1191:2000 Operating forces BS 6375-2:2009 BS EN 12046-1:2003 Soft and heavy body impact BS 6375-2:2009 BS EN 13049:2003 Resistance to racking BS 6375-2:2009 BS EN 14608:2004 Resistance to static torsion BS 6375-2:2009 BS EN 14609:2004 Strength of safety devices BS 6375-2:2009 BS EN 14609:2004 Documented In-House Method No EX-FI-OP-BH-WL-SOP-056 ssessment Manager: PJ1 Page 17 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to WINDOWS: SINGULR and MULTILIGHT - top hung (open out), side hung (open in and open out), bottom hung (open in), butt hinged - top and side hung (open out), projected - top hung fully reversible - tilt and turn and turn and tilt - fixed and dummy vents - double opening (French windows) Manipulation test Infill medium removal - manual test Infill medium removal - mechanical test Mechanical loading test Manual check test BS 6375-3:2009+1:2013 PS 24:2012 WINDOWS: SINGULR and MULTILIGHT - top hung, side hung, bottom hung, butt hinged - top and side hung projected - top hung and side hung fully reversible - tilt and turn and turn and tilt - vertical and horizontal sliding - fixed and fixed casements (dummy vents) - parallel opening - double opening (French windows) - vertical and horizontal pivot Manipulation test Infill medium removal - manual test Infill medium removal - mechanical test Mechanical loading test Manual check test PS 24:2016 WINDOWS - Sliding, Lift and Slide or Lift and Slide and Tilt windows and door-height windows Resistance to repeated opening and closing BS EN 1191: 2012 nnex B WINDOWS - Vertical Sliding windows Resistance to repeated opening and closing BS EN 1191: 2012 nnex F WINDOWS - side-hung and top-hung windows, opening outwards (including reversible windows) Resistance to repeated opening and closing BS EN 1191: 2012 nnex G ssessment Manager: PJ1 Page 18 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to DOORS -side-hung pedestrian doorsets excluding power operated doors (single and double leaf doorsets, with or without self-closing devices) Resistance to repeated opening and closing BS EN 1191:2012 nnex H UTOMOTIVE TRIM and COMPONENTS LOW TEMPERTURE TESTS: BS EN 60068-2-1:2007 Minimum temperature: -40 ºC Maximum chamber size: 6.00 m x 3.00 m x 2.50 m high DRY HET TESTS: Maximum temperature: +150 ºC BS EN 60068-2-2:2007 IEC 60068-2-2:2007 Jaguar / Land Rover TPJLR.52.352 Issue 2:2011 Maximum chamber size: 5.00 m x 3.00 m x 2.50 m high Maximum temperature: +200 ºC Maximum chamber size: 1.20 m x 0.70 m x 1.40 m high TEMPERTURE CHNGE VRITION: Maximum chamber size: 6.00 m x 3.00 m x 2.50 m high BS EN 60068-2-14:2009 Jaguar / Land Rover TPJLR.52.353 Issue 3:2011 CYCLIC HUMIDITY: Maximum chamber size: 6.00 m x 3.00 m x 2.50 m high BS EN 60068-2-30:2005 BS EN 60068-2-78:2002 Jaguar / Land Rover TPJLR.52.351 Issue 232011 brasion (Taber) SE J948:December 2003 Ford FLTM BN 108-02 Honda 7710 ZSCC_9000 6.7 Nissan NES M0141 6.2.8 Toyota TSM 0502G 4.6.4 ssessment Manager: PJ1 Page 19 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to UTOMOTIVE TRIM and COMPONENTS (cont d) Colour fastness to rubbing BS EN ISO 105-X12:2002 Ford FLTM BN107-01 VW PV 3906 Scratch resistance Ford FLTM BN 108-13 GMW 14698 Method B Jaguar / Land Rover TPJLR.52.004 Paint adhesion STM D 3359-09e2 Ford FLTM BI 106-01 Nissan NES M0141 6.2.4 Methods and B Jaguar / Land Rover TPJLR.52.062 issue 2 2012 DIN ISO EN 2409:2013 Chemical resistance Ford FLTM BO 101-05 Jaguar / Land Rover TPJLR.52.154 and TPJLR.52.155 Soiling and cleanability Ford FLTM BN 112-08 Jaguar / Land Rover TPJLR.52.210 issue 2 2010 Resistance to chipping SE J400 Ford FLTM BI 157-06 Jaguar / Land Rover TPJLR.52.599 Nissan NES M0141 6.2.3 Toyota TSM 0502G 4.5.4 Corrosion resistance STM B117 2011 Jaguar / Land Rover TPJLR.52.252 END ssessment Manager: PJ1 Page 20 of 21

Schedule of ccreditation United Kingdom ccreditation Service ccredited to ccreditation for the purpose of Notified Body activity taking into account E 2/17 Directive / Regulation Conformity ssessment Procedure / Module / rticle Category of Products or Individual Products Essential Requirements: Product Specification / Properties / Standards The Construction Products Regulation (EU) No 305/2011 nnex V - Testing Laboratory (VCP) System 3 - including testing away from site (rticle 46) 99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) : - Doors and gates (with or without related hardware) (other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-inuse (i.e. NOT for fire/smoke compartmentation, NOT for escape routes)). EN 13241:2003 + 2:2016 EN 14351-1:2006+1:2010 nnex V - Testing Laboratory (VCP) System 3 99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) : - Windows (with or without related hardware) (any other). EN 14351-1:2006+1:2010 END ssessment Manager: PJ1 Page 21 of 21