SPACE TYPE: CHILD CARE

Similar documents
Library stacks and records storage 150 LB/SF live load

SPACE TYPE: JUDICIAL CHAMBER

Vanilla Box Design Criteria

room data sheet CORDOVA RESIDENCE 1/11 54 EAST CORDOVA STREET, VANCOUVER, BC RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

CLEVELAND HEIGHTS UNIVERSITY HEIGHTS CITY SCHOOL DISTRICT MONTICELLO & ROXBORO MIDDLE SCHOOLS INTERIOR DESIGN

room data sheet MARBLE ARCH HOTEL 518 RICHARDS STREET, VANCOUVER, BC 1/14 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

room data sheet TAMURA HOUSE 396 POWELL STREET, VANCOUVER, BC 1/8 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

SCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003

room data sheet GASTOWN HOTEL 110 WATER STREET, VANCOUVER, BC 1/11 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

room data sheet ORANGE HALL 341 GORE AVENUE, VANCOUVER, BC 1/8 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

Introducing... The Lake Country Series. 18 Wide Single Section Homes. ... our WIDEST single section homes! Canada. Proudly made in

MOLSON S BANK BUILDING 166 EAST HASTINGS STREET, VANCOUVER, BC

MEDIA CENTER September 30, 2010

A heritage of excellence. Lifestyle. Choice. For you. For life.

room data sheet MARR HOTEL 401 POWELL STREET, VANCOUVER, BC 1/9 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

TRADITIONS 2017 COLLECTION SINGLE SECTION HOMES

SPACE NEEDS PROGRAM. Leicester Fire Department. Leicester Fire Station. July 27, 2009

2 Main Office Building BLDG-955A Building Purpose Building Area Administration offices. Training room 7,610 SF Inspection Date August 16, 2016 Inspect

FOOD SERVICE May 6, 2016

FOOD SERVICE May 6, 2016

Use a minimum loading pad 6' curb length of a hard surface to connecting curb and sidewalk.

Columbia Single Section Homes

Facilities Management State-Funded and Billable Services

The Lake Country Series


KCKHA PRICE LIST 2015

The Lake Country Series

Proudly made in. Canada. to Canadian Standards. The Columbia Series. 14 Wide Single Section Homes

The Charleston RM x 54 Ranch 1638 Total Sq. Ft. 3 Bedrooms / 2 Baths

CULINARY OPERATIONS September 30, 2010

Proudly made in. Canada. to Canadian Standards. The Columbia Series. 14 Wide Single Section Homes

Taylor Oaks. Architecturally Enhanced Exterior Features: Efficient Kitchens Designed for the Gourmet Chef or the Busy Family: Luxurious Master Suites:

Estimate Form for Kitchen Design and Installation

THE HEMLOCK 3 BD 2.5 BA 1371 sq ft

EXHIBIT A-1 CITY OF BELLFLOWER JANITORIAL MAINTENANCE SPECIFICATIONS

Every manufactured and modular home Champion builds is professionally designed and engineered. Built by craftsmen in a controlled factory

24'-0" RAILING W/H CUBBIES 6' PORCH OPT. BOOK CASE. BUNK BEDS 33x74 OPT. REFER 3608 WDWS. TWO. QUEEN BED 60x80 HITCH LOCATION SHELF RAILING

The Lake Country Series

Examples of Acclaim s Energy-Efficiency Green Technology

PLAN REVIEW SUBMITTAL GUIDE

Structural Guidelines. Food Service Establishments. Retail Food Stores

Mechanical Inspection Plumbing

Platinum Features - Multi Section

Columns REF, RESPONSIBLE and COMPL TD are provided for your numbering, assignments and control. REF ISSUE RESPONSIBLE COMPL TD

About This Model. Series: Timberland Ranch Model: TL815A. Style: Ranch / Bedrooms: 3 / Bathrooms: 2 / Square Feet: Notes:

All Waters Edge homes come with the following standard features throughout:

Proudly made in. Canada. to Canadian Standards. The CJ Series. 20 Wide Homes

Procurement Department ADDENDUM # 1

Avalanche SERIES. Featuring Homes Built By: Weiser, ID

Closing Checklist. Mstr Hall/Clo. Mstr Bath. Guest Bath 1/2 Bath Kitchen Nook. Guest Hall. Utility Rm Garage Yard. Right Side Left Side Rear

Stairway Location for Optional Foundation Model

Damaged Item Replacement Price List

About This Model. Series: Cambridge 2 Ranch Collection Model: LX329A Magnifique Grand. Style: Ranch / Bedrooms: 3 / Bathrooms: 2 / Square Feet: 1804

The Lake Country Series 16 Wide Single Section Homes

COSMETOLOGY September 30, 2010

Bath Planning Worksheet

DESIGNER KITCHEN WITH PREMIUM APPLIANCES 1407 & 1409 Military Trail Features & Finishes 1. Open concept kitchen with NEFF designer cabinetry and Caesa

Newberry. Foundation Framing

Damaged Item Replacement Price List

About This Model. Series: Aurora Classic Ranch Modular Model: AW420A Savanna II. Style: Ranch / Bedrooms: 4 / Bathrooms: 2 / Square Feet: 2280.

TheHeritage COLLECTION SINGLE SECTION HOMES

Camden. Included Features. Prices are non-negotiable. Continued on Back ATTRACTIVE INTERIORS:

Standard Features. ashbysbridge.com. Mobile: (757)

Coquille Indian Housing Authority Maintenance Report February 2017

THE CROWN SERIES. Coco, Jackson & Myrtle Floorplans REV *With Craftsman Package

VOTER BOND REFERENDUM 2018 SUMMARY OF WORK PROPOSED

The Ultimate Home Value with Quality, Durability & Flexibility in Design

About This Model. Series: Cambridge 2 2-Story Collection Model: HZ304A Crisfield. Style: 2-Story / Bedrooms: 3 / Bathrooms: 3 / Square Feet: 1812

DAMAGE CODES* CODE DAMAGE COST

MARY CRAPO CENTER Miller Road, Swartz Creek, Michigan

APEX. FAMILY of HOMES. from Redman Homes

MULTI-SECTION HIGHLAND ESTATES SERIES

1152 Vinetta - Des Peres The Wakefield Model $634,900

Scope of Work Single Family, San Diego, CA

FENG SHUI SAVVY. Penthouse & Sub-penthouse suite finishes

The Villas of Wyldewood

Aging-In-Place Remodeling Checklist

2 BED- 2 BATH 787 SQ.FT. 8402D SHELF SHELF 3 BED- 2 BATH 944 SQ.FT. 8483D

About This Model. Series: Richland ELITE Ranch Model: GF903A. Style: Ranch / Bedrooms: 3 / Bathrooms: 2 / Square Feet: 1813.

Calmeca Academy of Fine Arts and Dual Language

CHARGES FOR REPAIRS AND SERVICES Please note prices are subject to change without prior notice.

PLATTEVILLE MIDDLE SCHOOL

MUKWONAGO AREA SCHOOL DISTRICT CAPITAL IMPROVEMENT / MAINTENANCE STUDY

JANITORIAL SPECIFICATIONS

the Legacy collection MIDDLEBURY

Homes in Cates Bay - Overview

VENTURA WAS VOTED ONE OF THE 10 BEST PLACES TO LIVE IN 2015

Landscape Includes sprinkler system Irrigation, system maintenance, and landscape upkeep are all included in H.O.A. dues

Cleaning Checklist and Instructions

C O V E S E R I E S NealCommunities.com SOuthwESt FlORIda S most ExpERIEnCEd home builder FOR OVER 40 years

Residential Accessibility Checklist - for Unit Types A and B With Connecticut Amendments Type A Units Accessibility Requirements rev.

Richard Henry Lee Elementary School

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

8483D 3 BED- 2 BATH 944 SQ.FT.

PH FX

22576 INSPIRATION POINT INTERIOR FEATURES BY ROOM

HOLUM EDUCATION CENTER. Architectural. January 13, 2014 DeForest Area School District

WORK DESCRIPTION HOUSING REHABILITATION PROGRAM HOUSING DEVELOPMENT DIVISION CITY OF COLORADO SPRINGS

MAINTENANCE STANDARD LABOR CHARGE ESTIMATE AMOUNTS

McLean Overlake New Home Features

Transcription:

SPACE TYPE: CHILD CARE Construction Criteria The unit costs for Child Care Center space types are based on the construction quality and design features in the following table. This information has been generally organized under Uniformat headings. Items marked with a have a space-related cost impact on the building shell and core. Shell Exterior Closure Exterior Doors Aluminum frame glass panel with intermediate rail Glass to be safety tempered coated low-e Keyed lever lockset with panic release bar on inside and automatic access control via card reader system Door position and latch keeper switch alarm system with manual interrupt switch monitored at the reception desk Automatic closers Shell Roof Closure Canopies Painted steel canopy with column supports at exterior main entry Cantilevered painted steel canopy at play yard and emergency exit exterior doors Interior Construction Partitions Suite Perimeter, and Public Corridor Classroom Perimeter Kitchen, Laundry, Work Rooms, Storage Rooms, Copier Areas ½ GWB on metal studs at 16 OC Floor-to-ceiling above ½ radius molding on all outside corners Structural slab-to-slab Two layers ½ GWB both sides on metal studs at 16 OC Acoustical insulation caulked top and bottom 55 STC ½ radius molding on all outside corners Structural slab-to-slab One layer ½ GWB both sides on metal studs at 16 OC Acoustical insulation 40 STC ½ radius molding on all outside corners Structural slab-to-slab ½ GWB on metal studs at 16 OC Acoustical insulation 40 STC Child Care 13-1

Telephone Closets, Communications Closets Structural slab-to-slab 5 / 8 GWB on metal studs at 24 OC Doors Main Suite Public Entrance Perimeter Exits Kitchen, Laundry, Work Rooms, Storage Rooms, Copier Areas Solid core 1¾ hardwood veneer doors 3-0 (w) by 7-0 (h) Doorframes will be a minimum 14 gauge metal frame construction Hardware to be latch sets with levers Structural tempered glass door system ¾ thick 6-0 (w) by 7-0 (h) tempered glass door with 3 ½ top and bottom rails Overhead closer and centered pivot hinges Electromechanical fail-safe lock with conduit to control point Card reader and door release control systems are not provided as part of standard improvements Door position and latch keeper switch alarm system with manual interrupt switch monitored at the reception desk Accommodations for door position and lock keeper switches Solid core 1¾ hardwood veneer doors 3-0 (w) by 7-0 (h) Doorframes will be a minimum 14 gauge metal frame construction Frame and threshold sound gasketing Hardware to be locksets with levers Key locks and fail-safe electric locks with conduit to control points Card reader and door release control system are not provided as part of standard improvements Door position and latch keeper switch alarm system with manual interrupt switch monitored at the reception desk Accommodations for door position and lock keeper switches Automatic closers Solid core 1¾ hardwood veneer doors 3-0 (w) by 7-0 (h) with full height tempered glass lite Doorframes will be a minimum 14 gauge metal frame construction Hardware to be locksets with levers Solid core 1¾ hardwood veneer doors 3-0 (w) by 7-0 (h) Door frames will be a minimum 14 gauge metal frame construction Hardware to be latch sets with levers Brushed stainless steel kick plate room side Interior Windows Interior Classroom Windows 20% of wall area to be glazed 50% glazed area to be at child viewing height Safety laminated glass with vision strips on areas below 42 Aluminum metal frame Signage Suite Entrance Child Care Center to be carved relief wood block panel 13-2 Child Care

Room Signage System Window Treatment Raised Floor Room signage to be hand painted acrylic letters and graphic images in multiple colors Rolling window shades Shade fabric to have 20% openness Provided as part of building shell and core provisions If raised floors are present, provide raised composite metal concrete slab pedestal under all toilets, kitchen, and laundry area Interior Finishes Walls Public Entrances, Reception Corridors Toilets Low VOC semi-gloss paint with vinyl cove base Linoleum wainscot with low VOC semi-gloss paint upper wall with vinyl cove base Linoleum wainscot with low VOC semi-gloss paint upper wall and vinyl cove base Ceramic tile with ceramic tile cove base Floors Public Entrance Reception, Director s Office, Parent Teacher Conference Raised floor area to be linoleum Non-raised floor area to be linoleum Drained entrance grid with structural aluminum rails, drain pan and carpet tread inserts of monofilament solution died nylon fusion bonded to backing 6-0 broadloom carpet Accent border 32 oz per square yard level loop Yarn dyed color with pattern Fourth generation nylon yarn Bonded construction with cushioned back Combination 85% linoleum and 15% carpet 6-0 broadloom carpet Accent border 32 oz per square yard level loop Yarn dyed color with pattern Fourth generation nylon yarn Bonded construction with cushioned back Ceiling Toilets, Kitchen Suspended 24 by 24 acoustical tile ceiling included in building shell and core provisions Drop ceiling (12 ) at 25% classroom with GWB fascia at change in height Painted textured GWB Soffit over counter areas Child Care 13-3

Plumbing Staff Lounge Toilets Sick Bay Kitchen Laundry Janitor Closet Playground Central hot water heater to serve all plumbing within the center Brushed stainless steel sink inset in counter with lever gooseneck faucet Cold and hot water supply ¼ cold water lines for coffee maker Stainless steel art sink and food service sink inset in counter with flat bottom and gooseneck faucet with wrist blades Wall-mounted porcelain hand wash lavatory at toilet and diaper changing station with wrist lever and hands free controls Cold and hot water supply Porcelain wall mounted drinking fountain Floor mounted porcelain child s toilet Porcelain sink wall-mounted Lever faucet Porcelain floor mounted flush-valve water closet Porcelain sink with hands free faucet operation inset in counter Three bay stainless steel sink with garbage disposal Two bay stainless steel sink with garbage disposal ¼ cold water supply line to refrigerator and ice maker Floor drain with primer Hot and cold hose bibs and waste drain connections for washing machine Floor drain with primer Porcelain janitor mop sink with hot and cold water supply Porcelain wall mounted drinking fountain and hose bid, one per play yard HVAC Air Distribution System Air Handling Unit Air Supply Exhaust Air AHUs are part of the building shell and core provisions; assume no additional cooling capacity is required New air filters to be provided at time of Tenant Improvement Separate zones for each childcare room See building shell and core provisions for other zoning requirements For centers in buildings with standard raised floor, pressurized raised floor air supply with ceiling plenum return air is part of the building shell and core provisions For centers without raised floor, ducted ceiling supply with ceiling return air plenum Acoustical transfer ducts at all acoustically rated partitions at classrooms, parent teacher rooms, and multiple purpose rooms Direct 100% toilet room exhaust operated by time clock or BAS Dedicated kitchen hood exhaust air and make-up systems Laundry exhaust and make-up system 13-4 Child Care

Thermostat Controls provide separate control Provide setback thermostat with override by building shell and core BAS Fire Protection Fire Suppression Fire and Smoke Detection Fire Alarms Sprinkler system is part of the building shell and core provisions; assume that Tenant Improvements for this space type require relocation of 10% sprinkler heads Fire and smoke dampers to be provided in rated walls One smoke and heat detection devices in each occupiable space One fire alarm pull station by each egress point Audible and visible (strobe) alarm in each occupiable space Electrical Electrical Outlets Entrance, Reception Director s Office, Parent Teacher Conference Work Room Kitchen Laundry Telephone Closet, Communications Closet All electrical outlets to be mounted at 54 above the floor All electrical outlets will be child tamper resistant per ASTM 517-18c Each non-classroom space will have wall mounted duplex outlets every 25-0 OC Four reception counter mounted duplex outlets; one duplex outlet with dedicated line One recessed wall duplex outlet for clock Three wall mounted duplex outlets Two wall mounted child resistant duplex outlets for computer and AV equipment Two splash-mounted child resistant GFI duplex outlets One duplex backsplash-mounted outlet every 48 of counter run; one duplex outlet with dedicated line Provide special NEMA types as required for copiers Electrical outlets for refrigerator, ice maker, dish washer, and garbage disposal High voltage electrical connections for range and oven Wall mounted duplex outlets every 5-0 OC Special voltage for dryer One wall mounted duplex outlet Two dedicated duplex outlets on emergency power, plus additional outlets for every 6-0 of wall space Provide a separate 120-volt panel with master switch, and five 20-amp circuits Lighting Parabolic fluorescent 24 (w) by 48 (l) recessed ceiling fixtures with two T-8 lamps and electronic ballasts located every 80 SF (or T-5 equivalent) Full color spectrum bulbs, 3500 5000 Kelvin with 85 CRI index (minimum) All fixtures to have lens guards Independent switch control for each room with 3 way switches at each entrance and for each enclosed space, including offices, work rooms, file rooms, and closets Dimmers in all classrooms and sick rooms Child Care 13-5

Office, Conference, Staff Lounge Parabolic fluorescent 24 (w) by 48 (l) recessed ceiling fixtures with two T-8 lamps and electronic ballasts located every 80 SF (or T-5 equivalent) Kitchen Parabolic fluorescent 24 (w) by 48 (l) recessed ceiling fixtures with two T-8 lamps and electronic ballasts with acrylic lens located every 80 SF (or T-5 equivalent) Independent switch Toilets Parabolic fluorescent 24 (w) by 48 (l) recessed ceiling fixtures with two T-8 lamps and electronic ballasts with color corrected lamps located every 80 SF (or T-5 equivalent) Telephone and Communication Outlets Reception/Entrance, Parent Teacher Room, Work Rooms, Staff Lounge Security Systems and Duress Alarms Conduit and pathways for services from the core to the tenant demised space provided as part of the building shell and core provisions; conduit and boxes within the tenant suite are part of the Tenant Improvement unit costs Conduit and telephone outlet boxes are provided as part of the Tenant Improvement unit costs; telephone systems and data LAN systems are provided from Conduit and boxes for one telephone connection in each room; equipment and wiring provided from Conduit and boxes for one ceiling mounted PA speaker for each room; equipment and wiring provided from Conduit and boxes for enunciator/intercom from entrance to reception desk provided as part of Tenant Improvement unit costs; equipment and wiring provided from Conduit and boxes for two LAN connections at the reception desk provided as part of the Tenant Improvement unit costs; equipment and wiring provided from Conduit and boxes for two wall mounted telephone lines provided as part of the Conduit and boxes for one LAN connection provided as part of the Tenant Improvement unit costs; equipment and wiring provided from Conduit and boxes for one ceiling mounted PA speaker provided as part of the Power connection, conduit, and boxes provided as part of Tenant Improvement unit costs; equipment and wiring provided from 13-6 Child Care

Suite Reception Director s Office Power connection, conduit, and boxes for remote door release provided as part of Power connection, conduit, and boxes for keypad door control provided as part of Power connection, conduit, and boxes for duress alarm provided as part of Tenant Improvement unit costs; equipment and wiring provided from Power connection, conduit, and boxes for intercom provided as part of Tenant Improvement unit costs; equipment and wiring provided from Power connection, conduit, and boxes for CCTV camera provided as part of Power connection, conduit, and boxes for one desk mounted duress alarm provided as part of Tenant Improvement unit costs; equipment and wiring provided from Commercial Equipment Laundry Kitchen Power, utility connection, and installation for commercial grade washer provided as part of Tenant Improvement unit costs; equipment from Power, utility connection, and installation for Commercial grade dryer provided as part of Tenant Improvement unit costs; equipment from Power, utility connection, and installation for two industrial ovens provided as part of Tenant Improvement unit costs; equipment from Power, utility connection, and installation for four-burner range provided as part of Tenant Improvement unit costs; equipment from Power, utility connection, and installation for one dishwasher provided as part of Tenant Improvement unit costs; equipment from Power, utility connection, and installation for a residential grade range hood over the ranges provided as part of Tenant Improvement unit costs; equipment from Power, utility connection, and installation for two refrigerators and one freezer unit provided as part of Tenant Improvement unit costs; equipment from separate Power, utility connection, and installation for one ice maker provided as part of Tenant Improvement unit costs; equipment from Furnishings Casework Public Reception All millwork to be AWI custom grade hardwood veneer panels and plastic laminate tops with solid hardwood dimensional lumber and recessed pulls 10-0 (l) counter with transaction height 10 (d) surface, and 29 (h) desk surface behind with fluorescent strip tube lighting, grommet holes for wiring, and two pedestals with drawers Child Care 13-7

Kitchen Sick Bay Workroom Lounge, Storage Rooms, Copier Rooms Installation of child cubbies with one cubby per child; cubbies provided from Installation of teacher cubbies with three cubbies per child; cubbies provided from Upper cabinets and counter for food service, artwork, and teacher preparation Diaper changing station in all classrooms with lower cabinet, counter, and upper cabinet AWI custom grade plastic laminate counter, base, and upper cabinet Cabinet with lockable upper cabinet for medicine storage provided as part of AWI custom grade plastic laminate cabinets with plastic laminate counters Fixed Classroom Workroom Lounge, Storage Rooms, Copier Rooms, Laundry, Janitor Closet Installation of lofts and soft forms; furniture provided by Modular steel wire shelving units Site Improvements Fence Sidewalk and Hard Surface Areas Plant Material Additional fences, sidewalks, hard surface areas for play yards and exterior entrances, and additional plant material are carried in the Tenant Improvement site work allowance Playground equipment and finishes are carried in Mounting and surfaces carried in playground finishes allowance 6-0 (h) 6 gauge wire mesh at 2 x 6 with integral folds on 16 gauge 2 square steel posts Fence and posts colored polyester finish over galvanized base Provide concrete walkways 6-0 (w) at entrance Provide concrete patio area for 10% of the play yard area Provide a 44 (w) bike trail serpentine path around the perimeter of each play yard Provide bushes around perimeter fences on the outside to discourage climbing on the fences Provide overstory shade trees for summertime shade Provide sprinkler system to all plant material 13-8 Child Care

Playground Equipment Support pads, mounting and installation of playground equipment provided as part of Tenant Improvement unit costs For preschool and kindergarten playgrounds provide steel raised platform equipment with integral slides, climbing structures, ladders, fantasy play attachments (steering wheels, scopes, et cetera) and shade devices as part of ; provide 10 platform areas with ramp access to at least one platform and one platform positioned at wheelchair offload height as part of For infant and toddler playgrounds provide plastic formed snap together playground equipment with platforms, slides, playhouse and fantasy play configurations as part of All edges are to be rounded and all connections protected to prevent injury Provide interlocking playground rubber cushion tiles in fall zone area for 6-0 radius around the play equipment; provide a tile drain system under the fall zone resilient surface Rubberized playground surface 60% of total playground areas; 2 ¼" (d) on 75% and 3 ¾" (d) on 25% Child Care 13-9