ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

Similar documents
ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

CHAMPION PUMP OWNER S MANUAL

SMF PUMP OWNER S MANUAL

Elite Primer Baldor Series External Pond Pump

QUIETFLO OWNER S MANUAL

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

AQUA-FLO A SERIES. The Bronze Pump designed exclusively for any swimming pool or spa application.

INSTALLATION INSTRUCTIONS

SuperFlo High Performance Pump

SPARUS 160 ENERGY EFFICIENT AQUACULTURE DUTY PUMP

INSTALLATION & OPERATING INSTRUCTIONS

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Clean & Clear. Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

CHALLENGER CENTRIFUGAL PUMP

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

HIGH PERFORMANCE PUMP

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

HIGH PERFORMANCE 3-PHASE PUMPS

VARIABLE SPEED PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

LC Series - Light Commercial Pump Station Installation and Operation Manual

HIGH PERFORMANCE PUMPS

Pump - Owner s Manual

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

OWNERS GUIDE TO INSTALLATION AND OPERATION

50 HZ. MAX-E-PRO CENTRIFUGAL PUMPS WITH INTEGRAL TRAP

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS. Super Pump Series

Perfect Settings Warranty Information

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Installation, Operating, and Service Manual. Badu. EcoM3. Swimming Pool Pump

MAX-E-GLAS 2 SPEED CENTRIFUGAL PUMPS with TRAP

Jacuzzi. J-VSP150, J-VSP250 Pump Installation and Operating Instructions

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

HAYWARD POOL PRODUCTS, INC. 620 Division Street Elizabeth, NJ Tel:

Variable Speed. Installation and User s Guide. Programmable Pump IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS

SuperKlean Washdown Products

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

INSTRUCTION MANUAL DN0136 REVISION D

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

569, 570, 571, 572 Series

STAINLESS STEEL UNITS

569, 570, 571, 572 Series

568X, 587X, 588X Series

6. Cooling System XCITING 400i. This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i.

DESCRIPTION MAINTENANCE INSTALLATION OF NEW SEAL REMOVAL OF OLD SHAFT SEAL

SERIES ABG SWIMMING POOL PUMP

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Audi-Larm Audible Alarm

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

sta-rite Call C and CC Series Installation/Operation/Parts For further operating, installation, or maintenance assistance:

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS

SSHM-2. Call Self-Priming Horizontal Multistage Pump. For further operating, installation, or maintenance assistance:

16 OUTDOOR MISTING FAN

BACK WASH INSIDE THE SPA

QUICK PRIME INSTALLATION AND SERVICE MANUAL

VL Series Pump. Owner s Manual. NOTE - To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completely.

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

QUICK PRIME INSTALLATION AND SERVICE MANUAL

OWNER S MANUAL. SilentFlo. Pool Pump. For the Installation, Operation and Service of

489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power

Parts & Material Included

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

Food Waste Disposer Instruction Manual

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Chilipepper CP9000. Installation Instructions READ BEFORE INSTALLING:

Pool Power Pak. III with On/Off Switch UL Models (1 HP), (1-1/2 HP) NEC Models (1 HP), (1-1/2 HP)

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS SAVE THIS INSTRUCTION MANUAL

EQ SERIES High Performance Commercial Pump

Next Generation Corona Discharge Installation & Operation Manual

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS

AquaStream. ½ HP Floating Fountain. Please Keep for Your Records. Model #AS05 6A, 120V/60Hz Owner s Manual UNIT IDENTIFICATION

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER

DYNA-PRO TM CENTRIFUGAL PUMPS WITH INTEGRAL TRAP

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

OWNERS GUIDE TO INSTALLATION AND OPERATION END SUCTION CENTRIFUGAL PUMPS

DRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

MDX² INSTALLATION MANUAL

Instant Hot Water Dispenser Owner s Manual

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

Chilipepper CP8000. Installation Instructions READ BEFORE INSTALLING:

ULTRA STRIP DRAIN OWNER S MANUAL VGB 2008 IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF ENTRAPMENT HAZARDS:

Wall Mount Electric Fireplace

SAVE THIS INSTRUCTION MANUAL

Domestic Pump Vacuum and Boiler Feed Units Series VCMD TM INSTRUCTION MANUAL DN0137 REVISION F

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

HIGH PERFORMANCE POOL & SPA PUMPS

DIAMOND STRIP DRAIN OWNER S MANUAL VGB 2008 IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF ENTRAPMENT HAZARDS:

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

Transcription:

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all warning notices and instructions accompanying this pump. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. ATTENTION INSTALLER: This manual contains important information about the installation, operation, and safe use of this product. This information should be given to the owner/operator of this equipment. NOTE: When pump is mounted permanently within 5 ft. of the inside walls of a swimming pool, you must use No. 8 AWG or larger conductor to connect to bonding conductor lug. WARNING: To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. CAUTION: For hot tubs and spas, do not install within an outer enclosure or beneath the skirt of a hot tub or spa unless so marked. Designed, Engineered & Manufactured in the USA 2200 East Sturgis Road, Oxnard CA 93030 Phone (805) 981-0262 Fax (805) 981-9403 www.waterwayplastics.com waterway@waterwayplastics.com

WIRING WARNING: RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or damage to property. Always disconnect power to the pool pump at the circuit breaker before servicing the pump. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electric shock. 1. Make sure all electrical breakers and switches are turned off before wiring motor. 2. Make sure that the wiring voltage matches the motor voltage (230v or 115v). If they do not match the motor will burn up. 3. Choose a wire size from Chart 1. When in doubt use a heavier gauge (larger diameter) wire. Heavier gauge will allow the motor to run cooler and more efficient. 4. Cut wires to the appropriate length so they don t overlap or touch when connected to the terminal board. SUPPLY WIRE SIZES (AWG) Size and Length by Horsepower HP 115 Volts 230 Volts 50 Ft. 100 Ft. 150 Ft. 50 Ft. 100 Ft. 150 Ft. 1/3 14 14 12 14 14 14 1/2 14 12 10 14 14 14 3/4 12 12 10 14 14 14 1 12 10 8 14 14 14 1 1/2 10 10 8 14 14 12 2 10 8 8 14 12 12 3 12 12 10 CHART 1 5. Make sure all electrical connections are clean and tight. 6. Permanently ground the motor using the correct wire size and type specified by National Electrical Code. Make sure the ground wire is connected to an electrical service ground. 7. Bond the motor to the pool structure in accordance with the National Electrical Code. Use a solid No. 8 AWG or larger copper conductor. Run a wire from the brass external bonding clamp to the pool bonding structure. 8. Connect the pump permanently to a circuit. Make sure no other lights or appliances are on the same circuit. NOTE: If the pump is installed below the water level of the pool, close return and suction lines prior to opening hair and lint pot on pump. Make sure to re-open valves prior to operating. 2

ECONO FLO VSA 165 VARIABLE SPEED MOTOR WARNINGS & ASSISTANCE Please store this instruction sheet and the A.O. Smith user interface booklet in a safe place for future use. Please carefully read the entire enclosed booklet for the operation and troubleshooting of the Econo Flo VSA 165. For technical assistance or questions related to the operation of the A.O. Smith motor and programming of the user interface, please contact A.O. Smith: Call: 800-262-6484 or 866-887-5216 Visit: www.aosmithmotors.com 3

PUMP STRAINER BASKET This unit, sometimes referred to as the Hair and Lint Pot, is the unit in front of the volute. Inside the chamber is the basket which must be kept clean of leaves and debris at all times. View basket through the See Through Lid to inspect for leaves and debris. Regardless of the length of time between filter cleaning, it is most important to visually inspect the hair and lint pot basket at least once a week. A dirty basket will reduce the efficiency of the filter and heater and also put an abnormal stress on the pump motor which would result in a costly repair bill. WARNING: DO NOT open the strainer pot if pump fails to prime or if pump has been operating without water in the strainer pot. Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding hot water. Opening the pump may cause serious personal injury. In order to avoid the possibility of personal injury, make sure the suction and discharge valves are open and strainer pot temperature is cool to touch, then with extreme caution. CAUTION: To prevent damage to the pump and filter and for proper operation of the system, clean pump strainer and skimmer baskets regularly. WARNING: THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATION SYSTEM (e.g. LOCK RING, PUMP, FILTER, VALVES, ETC) IS SERVICED, AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED. PRESSURIZED AIR CAN CAUSE THE LID TO BLOW OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE. TO AVOID THIS POTENTIAL HAZARD, FOLLOW THESE INSTRUCTIONS. 1. Turn off motor. 2. Relieve pressure in the system. 3. Turn the lid in a counter-clockwise direction until it stops. 4. Lift lid and remove basket. 5. Put the debris from the basket into the trash and rinse out the basket. If the basket is cracked, it should be replaced. 6. Replace the basket and fill the pump pot and volute up to the inlet port with water. 7. Clean the cover, O-ring and sealing surface of the pump pot. Grease the O-ring with Teflon or silicone. 8. Reinstall the lid (Figure 1). 9. Make sure the lid O-ring is properly placed. Seat the lid then turn clockwise until hand tight (DO NOT over tighten with tools) (Figure 2). 10. Turn the power ON at the house circuit breaker. Reset the pool time clock to the correct time. 11. Open the manual air relief valve on top of the filter. 12. Stand clear of the filter. Start the pump. 13. Bleed air from the filter until a steady stream of water comes out. Close the manual air relief valve. Lid O-Ring Basket Pot FIGURE 1 Lid Volute 4 FIGURE 2

WINTERIZING CARE OF ELECTRIC MOTOR If the air temperature drops below 35º F. the water in the pump can freeze and cause damage. Freeze damage is not warrantable. To prevent freeze damage follow the procedures listed below. 1. Shut off electrical power for the pump at the house circuit breaker. 2. Drain the water out of the pump case by removing the two drain plugs from the case. Store the plugs in the pump basket. 3. Cover the motor to protect it from severe rain, snow, and ice. 4. Do not wrap the motor in plastic. It will cause condensation and rust on the inside of the motor. PROTECT FROM HEAT 1. Shade the motor from the sun. 2. Any enclosure must be well ventilated to prevent overheating. 3. Provide ample cross ventilation. PROTECT AGAINST DIRT 1. Protect from any foreign matter or splashing water. 2. Do not store (or spill) pool chemicals near the motor. 3. Avoid sweeping or stirring up dust near the motor while it is operating. 4. If a motor has been damaged by it voids the warranty. PROTECT AGAINST MOISTURE 1. Protect from splashing pool water. 2. Protect from the weather. 3. Protect from lawn sprinklers. 4. If a motor has become wet let it dry before operating. Do not allow the pump to operate if it has been flooded. 5. If a motor has been damaged by water it voids the motor warranty. NOTE: DO NOT wrap motor with plastic or other air tight materials. The motor may be covered during a storm, for winter storage, etc., but NEVER when operating or expecting operation. WARNING: RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or damage to property. Always disconnect power to the pool pump at the circuit breaker before servicing the pump. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electric shock. WARNING: DO NOT open the strainer pot if pump fails to prime or if pump has been operating without water in the strainer pot. Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding hot water. Opening the pump may cause serious personal injury. In order to avoid the possibility of personal injury, make sure the suction and discharge valves are open and strainer pot temperature is cool to touch, then with extreme caution. 5

PUMP DISASSEMBLY CAUTION: Be sure not to scratch or mar the polished seal faces. Seal will leak if faces are damaged. All moving parts are located in rear sub-assembly of this pump. Tools required: 1/2 inch open end wrench 9/16 inch open end wrench Flat and Phillips head screwdrivers To remove and repair the motor sub-assembly perform the following procedures. 1. Turn off the pump circuit breaker at the main panel. 2. Drain the pump by removing the drain plugs. 3. Remove the 6 bolts that hold the main pump body (strainer pot/ volute) to the rear sub-assembly. 4. GENTLY pull the two pump halves apart, removing the rear subassembly. 5. Remove the diffuser. 6. Hold the impeller securely in place and remove the impeller lock screw by using a Phillips head screwdriver. The screw is a lefthanded thread and loosens in a clockwise direction. 7. Remove the shaft cap located at the back of the motor and hold the shaft secure with a flat-head screwdriver (Century) or 7/16 inch open-end wrench (Franklin). 8. To unscrew the impeller from the shaft, twist the impeller counter clockwise. 9. Remove the four bolts from the seal plate to the motor, using a 9/16 inch wrench. 10. Place the seal plate face down on a flat surface and tap out the carbon/spring seal. 11. Clean the seal plate, seal housing, and motor shaft. PUMP REASSEMBLY / SEAL REPLACEMENT CAUTION: The polished and lapped faces of the seal could be damaged if not handled with care. 1. When installing the replacement ceramic/carbon seal, use silicone sealant on the metal portion, before pressing into the seal plate. 2. Before installing the ceramic section of the seal into the impeller, be sure the impeller is clean. Use a light density soap and water to clean the seal. Press the seal into the impeller with your thumbs and wipe off the ceramic and carbon faces with a clean cloth. 3. Remount the seal plate to the motor. 4. Screw the impeller onto the motor shaft. 5. Screw in the impeller lock screw (counter-clockwise to tighten). 6. Remount the diffuser onto the seal plate. 7. Grease the diffuser O-ring. 8. Assemble the motor sub-assembly to the strainer pot-pump body. DO NOT tighten down any of the bolts until all 6 bolts are in place and finger tight. 9. Fill the pump with water. 10. Reinstall the pump lid by turning clockwise until hand tight (DO NOT over tighten with tools). 11. Prime the system; see Priming the Pump. 6

Econo Flo VSA 165 Pump Replacement Parts 11 13 17 FIGURE 3 21 25 8 1 18 20 14 26 15 16 10 2 4 5 6 7 23 24 Part No. 22 9 Description 1 350V120 MTR, 56 Frame 1.65HP Variable Speed 3 2 672-1350 Neoprene Motor Support Strip 3 319-1500 Motor Base 4 311-1450 Volute Faceplate 5 711-1400 Gasket, Faceplate 6 811-1090 Ceramic Impeller Seal 7 310-7420 Champion 2 HP Full 2.5 HP UPR Impeller Assembly 8 310-7470 Diffuser Assembly 9 805-0238 O-Ring-238 10 319-1420 Diffuser Plate, Champion pump 11 319-3260 Lid, 6" Trap 13 805-0436 O-Ring, 6" Trap Lid 14 315-1400 Pump Housing, Mini SVL 15 805-0014 O-Ring, Pump Drain Plug 16 715-1200 3/8" Quarter Slot Plug (SD Wet End) 17 319-1430 Basket Assembly, Champion Pump 18 819-0035 Bolt.375-16 x.875 long 20 819-0020 Mach. Hex screw 3/8-16 x 1 1/4" 21 820-0017 3/8" Flat washer Type B, Pool Pumps 22 819-0018 #4-40 UNCS Bolt Schs 23 711-4300 Washer, Impeller 24 819-4360 Screw Phil. Pan Head Left Hand 1/4-20 x 1" 25 319-1766 Handle 26 820-0016 Hex Nut 3/8-16 Fin Serrated 7

RESTARTING INSTRUCTIONS & PRIMING THE PUMP CAUTION: DO NOT run the pump dry. If the pump is run dry, the mechanical seal will be damaged and the pump will start leaking. If this occurs, the damaged seal must be replaced. ALWAYS maintain proper water level in your pool. If the water level falls below the skimmer opening, the pump will draw air through the skimmer, losing the prime and causing the pump to run dry, resulting in a damaged seal. If the pump is installed below the water level of the pool, close return and suction lines prior to opening hair and lint pot on pump. Make sure to re-open valves prior to operating. The pump strainer pot must be filled with water before the pump is initially started. Follow these steps to prime the pump. For 2-speed pumps: Pump should run on high-speed for priming. 1. Remove the pump lid. 2. Fill the pump strainer pot with water. 3. Reassemble the pump lid onto the strainer pot. The pump is now ready to prime. 4. Open the manual air relief valve on top of the filter, and stand clear of the filter. 5. Turn on the switch or time clock. 6. When water comes out of the manual air relief valve, close the valve. The system should now be free of air and circulating water to and from the pool. NOTE: Self-priming pump may take up to 3 1/2 minutes to reach a lift height of 10 feet. TROUBLESHOOTING FAILURE OF PUMP 1. Pump will not prime, too much air. Remedy: a. Check suction piping and valve glands on all suction gate valves. b. Secure lid on pump strainer pot and make sure lid gasket is in place. c. Check water level to make sure skimmer is not drawing air. 2. Pump will not prime, not enough water. Remedy: a. Make sure suction lines, pump strainer, and pump volute are full of water. b. Make sure valve on suction line is working and open (some systems do not have valves). c. Check water level to make sure water is available through skimmer. REDUCED FLOW AND/OR HEAD 1. Air pockets or leaks in suction line. Remedy: a. See item 1a of this section above. 2. Clogged impeller. Remedy: a. Turn off electrical power to the pump. b. Remove the bolts holding the volute to the seal plate. c. Slide the motor and seal plate away from the volute. d. Remove the diffuser. e. Clean debris from impeller. If debris cannot be removed, complete the following steps: (1) Remove left hand threaded bolt and gasket. (2) Remove, clean and reinstall impeller. (3) Reinstall left hand threaded bolt and gasket. f. Reinstall the diffuser and diffuser O-ring. g. Reinstall motor and seal plate into volute. h. Tighten bolts securely. 3. Pump strainer clogged. Remedy: a. Clean suction trap. Designed, Engineered & Manufactured in the USA 2200 East Sturgis Road, Oxnard CA 93030 Phone (805) 981-0262 Fax (805) 981-9403 www.waterwayplastics.com waterway@waterwayplastics.com