T. +44 (0) E.

Similar documents
ModuSat TP. Energy. Heat Interface Units

ModuSat TP. Energy. Heat Interface Units

T. +44 (0) E.

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

heat interface units A BOILER WITHOUT A FLAME

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

Contact person RISE Date Reference Page. Daniel Månsson P (13) Energy and circular economy

Domestic hot water (DHW) The substation can be supplied with connection pipes for DHW cylinder on the supply or return line.

Herz York Direct Heat Interface Unit

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

IDEAL LOGIC HEAT INTERFACE UNITS (HIUs) PRODUCT GUIDE.

SATK 30 heat interface unit

GIACOMINI HEAT INTERFACE UNITS

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options

ThermoDual Domestic hot water charging system

HW 22 District heating substation for indirect heating and domestic hot water systems

Metering systems 0548EN April 2014

Design & Product Guide. Danfoss FlatStations.

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

Akva Lux VX District heating substation for indirect heating and domestic hot water systems

SUPERIOR QUALITY HEAT INTERFACE UNITS PUTTING YOU IN CONTROL. Pegler Yorkshire

THERMAL INTERFACE UNITS. Designed and manufactured in the UK. Designed for performance

EZ Plate Instantaneous

Meibes Heat Interface Unit (HIU) A2RXE Instantaneous Hot Water & Space Heating

TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY

Contact person Date Reference Page Daniel Månsson P07886C-rev2 1 (14) Energy and bioeconomy

INSTALLATION AND SERVICING

Solar heating systems

Contact person Date Reference Page Daniel Månsson P (13) Energy and circular economy

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems

Trade Product List 2013 BIOMASS ACCESSORIES

Installation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Wall-mounted compact indirect heat interface unit SATK30 series Safety instructions Dimensions Technical specifications Installation Commissioning

Contact person Date Reference Page Björn Folkeson P (15) Energy and bioeconomy

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

DIRECT AND INDIRECT THERMAL ENERGY METERING

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems

Systems for central heating

Contact person RISE Date Reference Page Björn Folkeson P (13) Energy and circular economy

Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems

Pricelist Heating and cooling systems 2017

30% Safe. Take lead on your project with an efficient system concept. Technical handbook Danfoss EvoFlat systems from A-Z. evoflat.danfoss.

WL Instantaneous water heater

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Installation and operation manual for mixing modules FH-MJB and FH-MJC

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

FlatStation HIUs and Energy meters. HVAC Commissioning Modules DHW and BCW Manifolds. SAV Systems. Product Catalogue.

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

30% Take lead on your project with an efficient system concept. lower energy.

Instructions for installing and using HIPER HIU UK patent applied for:

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

60 C water temperature ensures thermal disinfection during hot water production

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

Contact person RISE Date Reference Page Björn Folkeson P03675B 1 (11) Energy and circular economy

Akva Vita Instantaneous water heater

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

THE REMEHA HIU RANGE Installation, operation and maintenance manual December 2017

FCX FUEL OIL CONDENSING BOILER RANGE

CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

CS TSV MIX-REGULUS CS TSV MIX REGULUS. Installation and Operation Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems

Instructions for installation and use Akva Lux II VX substations 1. Contents

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Heat Transfer Packages

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.

Stored Water District Heating Interface Units. Heat Interface Units

GIALIX. An adjustable power to match your needs for more economies! Wall-mounted electric boiler 2 to 196 kw. F RENCH Manufacturer.

Advance Split

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Contact person Date Reference Page Daniel Månsson P07886B-rev2 1 (14) Energy and bioeconomy

Roth fixed-value control set with high-efficiency pump

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Chapter 7 DIRECT AND INDIRECT THERMAL ENERGY METERING

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

ADVANCE ECB ELECTRIC COMBINATION BOILER

Contact person RISE Date Reference Page Daniel Månsson P (13) Energy and circular economy

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

The Ultimate Solution for Electric Central Heating. Fusion. Comet

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Contact person Date Reference Page Daniel Månsson P07886E-rev2 1 (14) Energy and bioeconomy

Where gas is not an option,

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

SDU A. SDU A Loops. (available in 3, 4, 5 loops) Water Based Systems. Standard Distribution Unit assembled with: A Blank Port (capped)

SmartPlate. Water Heaters. AERCO.com

TURBINE OIL FILTRATION AND DEHYDRATION UNIT - technical documentation - MODEL T1250

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems.

Technical Product Guide

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

Transcription:

Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution for hot water and space heating in satellite heating systems where DHW is provided instantaneously. Heating is provided via a plate heat exchanger, which separates primary and apartment circuits, and circulation pump. The unit is suitable for radiator or underfloor heating with thermostatic or climatic control of the water supply temperature Heating The heating circuit side consists of a plate heat exchanger, safety valve, manometer, sensors, ball valves, drain valve, air valve, expansion vessel and pulse-width modulation (PWM) pump. The temperature of the heating is controlled by an electronic controller with an outdoor temperature sensor via the Bus. The temperature control range is suitable for radiators or underfloor heating. Domestic hot water The domestic hot water is prepared in the heat exchanger and the temperature is regulated using a 2-way electronic control valve. The control of the DHW temperature ensures a fast production of hot water and maintains a constant supply temperature. When fitted, the lime scale reducer prevents lime scale formation. Features & Benefits Units suitable for single and multi-family homes Ultrasonic heat meter MID Certified Insulation shell Compact design, with minimum space required for installation Pipes constructed from copper Stainless steel Plate Heat Exchangers Braze-welded exchanger for primary circuit separation Braze-welded exchanger for DHW production Option of top, bottom or combination connections External filling loop PaySmart unit for debt free energy billing (Optional) SmartTalk two way communication In-built Non Return Valve on the return - Prevents incorrect pipework connection. Wilo PWM Pump - Provides compliance with 2015 pump efficiency regulations. Pressure Independent Control Valves (PICV) eliminate the requirement for 3 separate valves for the regulation of differential pressure, flow and heat energy. Hot water blending valve for additional DHW temperature safety. Wireless RS485 module can provide connection remotely without the requirement of a Bus network. (Optional) Control board works with TCP/IP and provides operation of up to three heating circuits. Remote monitoring, alarms and diagnostics ViewSmart Room Controller with optional ENE 3 model. No annual gas appliance inspections required. Cold water meter (Optional external) Capable of reading the electrical meter (Option for ENE3) Construction All pipes are constructed from copper and both plate heat exchangers are made of stainless steel. The connections are made by nuts and gaskets. The twin plate unit is fitted with a white steel casing for wall mounting. 2551167C 1

Technical Details DHW Performances MTP40-XX MTP50-XX MTP60-XX Twin Plate 40-XX Twin Plate 50-XX Twin Plate 60-XX Primary flow l/h 1000 1000 1000 Primary in/out C 85/34 85/31 85/22 DHW flow l/h 1122 1180 1390 Power kw 58 61 72 Primary flow l/h 1200 1200 1200 Primary in/out C 85/36 85/34 85/24 DHW flow l/h 1296 1370 1610 Power kw 67 71 84 Primary flow l/h 1000 1000 1000 Primary in/out C 80/35 80/32 80/23 DHW flow l/h 990 1050 1250 Power kw 51 55 65 Key MTP Twin Plate 40-XX DHW Plate Heat Exchanger, 50-XX number represents the 60-XX number of plates XX-10 Heating Plate Heat Exchanger, number represents the number of plates Technical features Nominal pressure: 10 bar (Optional 16 bar) Power supply voltage: 220/240 Volt (AC) 50 Hz Max supply temperature (Primary): 90 C Min DCW static pressure: 0.5 bar Brazing material: copper MTP 40-10 / 50-10 Connection sizes: ¾ ext thread MTP 60-10 Connection sizes: 1 ext thread, except Secondary heating connections: ¾ ext thread Primary flow l/h 1200 1200 1200 Primary in/out C 80/37 80/34 80/25 DHW flow l/h 1130 1210 1450 Power kw 59 63 75 Primary flow l/h 1000 1000 1000 Primary in/out C 70/33 70/31 70/23 DHW flow l/h 915 970 1165 Power kw 42 45 54 DHW in/out 10/50 10/50 10/50 Primary flow l/h 1200 1200 1200 Primary in/out C 70/35 70/33 70/24 DHW flow l/h 1040 1100 1370 Power kw 48 51 63 DHW in/out 10/50 10/50 10/50 Heating Performances Typical Radiator Systems Typical UFH Systems Twin Plate XX-10 Twin Plate XX-10 Primary flow l/h 500 470 450 Primary in/out C 85/65 80/65 70/50 Power kw 11 8 10 Apartment Circuit flow l/h 496 350 870 Apartment Circuit in/out C 50/70 50/70 40/50 2

Circuit diagram Typical MTP 40-10, 50-10 & 60-10 Components A B C D E F G Primary / DH flow Primary / DH return Domestic cold water Inlet Domestic hot water outlet Secondary / Apartment heating flow Secondary / Apartment heating return Connection for safety discharge Primary Circuit Side 1 Insulated plate heat exchanger (Heating) 2 Heating Pressure Independent Control Valve with actuator 3 Insulated plate heat exchanger (Domestic Hot Water) 4 DHW Pressure Independent Control Valve with actuator 5 Heat meter 6 Non-return valve DHW Secondary Side Circuit 7 Lime scale reducer (Optional) 8 Blending valve Heating Secondary Side Circuit 9 Heating expansion vessel 10 Low pressure switch 11 Safety relief discharge 12 Manometer 13 Heating circulation pump 14 Safety thermostat (Optional) Other connection arrangements are available (See the following two pages for typical arrangments). Contact the Technical Department for further information. Controls & Other Items 15 Wireless RS 485 16 Electronic control board 17 Room control unit 18 Strainer & IV assembly 19 Filling loop (External) 3

Typical Connections TL1 - MTP 40-10 & 50-10 All Top Connections BL4 - MTP 40-10 & 50-10 - All Bottom Connections BL5 - MTP 40-10 & 50-10 - Primary Flow & Return Connections at the Bottom BL7 - MTP 40-10 & 50-10 - Primary Flow & Return & DCW Inlet Connections at the Bottom Evinox Ltd T. +44 (0)1372 722277 E. technical@evinox.co.uk W. www.evinox.co.uk 4

Typical Connections TL2 - MTP 40-10 & 50-10 - DHW Connection at the Bottom TL5 - MTP 40-10 & 50-10 - Secondary Heating Flow & Return Connections at the Bottom TL8 - MTP 40-10 & 50-10 - Primary Flow & Return Connections at the Top 5

Dimensions MTP 40-10 & 50-10 Top Connections Other connection arrangements are available. Contact the Technical Department for further information.. 6

Dimensions MTP 60-10 Other connection arrangements are available. Contact the Technical Department for Evinox further Ltd information. T. +44 (0)1372 722277 E. technical@evinox.co.uk W. www.evinox.co.uk 7