Figure 1: Low energy dwellings testsite

Similar documents
VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

Adelaide Homes Design Guide 4 - Winter warming

The Corbioli House is a single-family house situated

Residential ventilation concepts based on the idea of displacement airflow distribution

Simplified Space-Heating Distribution using Radiators in Super-Insulated Apartment Buildings

Villa Bagatelle Technical Report

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Performance of the Low-energy House in Sisimiut

nzeb office building

ENERGY EFFICIENCY BRIEF REPORT

AERECO DEMAND CONTROLLED VENTILATION COMBINING INDOOR AIR QUALITY AND ENERGY SAVINGS

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

Victoria & Albert Museum, London Medieval & Renaissance Galleries: A Passive Approach to Humidity Control

RESEARCH HIGHLIGHT. Arviat E/2 Northern Sustainable House Energy Consumption Performance Assessment

Evaluation on Residential Energy Efficiency Programs Using the City-Scale End-Use Simulation Model

Appendix C House models for Dymola to be used in connection with the OPSYS test rig and annual simulations of the performance of heat pumps

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

Control of temperature and humidity surrounding the stone chamber of Takamatsuzuka tumulus during its dismantlement

SOLAR COMBISYSTEMS IN DENMARK - THE MOST COMMON SYSTEM DESIGNS

OCCUPANT INTERACTION WITH VENTILATION SYSTEMS 7th AIC Conference, Stratford-upon-Avon, UK

Safe Heating in Sheltered and Social Housing

Indoor Climate Control Effect of AAC Panel Heat Capacity Experimental rooms and simulations with three structural materials

GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE

Typologies of Hybrid Ventilation in Schools

PASSIVE AND ACTIVE FIRE PROTECTION OF THE AIR HEATED SOLAR HOUSES

Storage and hot and cold water in a thermocline for Space heating/cooling and domestic hot water

Renovation concepts for saving 75% on total domestic energy consumption

- Murdoch University, Western Australia.

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

*Bioenergy GmbH Gewerbepark Haag 3, 3250 Wieselburg Land, Austria

INDEX. ADDITIONS AND ALTERATIONS Defined Requirements ADMINISTRATION AND ENFORCEMENT... Chapter 1 AIR ECONOMIZERS

for family composition, time allocation of people, ownership and specification of home appliances. This paper first presents the simulation procedure

Available online at ScienceDirect. Energy Procedia 78 (2015 )

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

COST EFFECTIVE PASSIVE SOLAR FOR NEW HOME CONSTRUCTION

Measurement and modelling of a multifunctional solar plus heatpump system from Nilan. Experiences from one year of test operation.

Solar thermal solutions within the Energy Labelling Context

Design with nature: integrating green façades into sustainable buildings with reference to Abu Dhabi

The Art of Building Science

COMPARISON OF HEATING SYSTEMS IN A RESIDENTIAL BUILDING

Study into the operation of a convector heater at low temperatures

EFFECT OF SATURATION EFFICIENCY OF DIRECT EVAPORATIVE COOLER ON INDOOR CONDITIONS AND THERMAL COMFORT IN A SMALL OFFICE ROOM OF A BUILDING

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

Passivhaus. sally godber MEng CEng MIMechE WARM: Low Energy Building Practice. The first 3 in the UK.

Secondary systems used in Europe.

SURVEY ON THE OCCUPANT BEHAVIOR RELATING TO WINDOW AND AIR CONDITIONER OPERATION IN THE RESIDENTIAL BUILDINGS

GUIDANCE AND TOOLS FOR CHILLED CEILINGS COMBINED WITH A WET COOLING TOWER

THE GRONG SCHOOL...2

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation

QUALITY CONTROL Passive House Checklist

Use each of the terms in the box to explain how heat is lost from inside a house through the window. conduction convection radiation

Energy Efficiency. Intercept HDDperDay <2e 16 kwhperday

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Cooling load calculations of radiant and all-air systems for commercial buildings

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

Residential Building Walls and Environment in Amman, Jordan

Desiccant Cooling with Solar Energy

The Use Of Attic Space For Cooling and Dehumidification

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.

EXCELSIOR SINHGAD COLLEGE OF ENGINEERING, PUNE PAPER PRESENTATION

NRC and Radon Control Technologies

Retrofitting a Multi-Unit Residential Building To Reduce Purchased Energy by a Factor of 10. Chris Richards

Smart Green Roofs: Cooling with variable insulation

Green Engineering. E-Design 100 Section 020. Group 5: The Lemons Submitted to Professor Smita Bharti (missing picture)

ENERGY CONSUMPTION OF HOUSES AND LIFESTYLE IN COLD CLIMATIC AREA OF JAPAN

Hot-air distribution in the floor heating

The importance of hot water system design in the Passivhaus

Interim Report for the Period thru February 15, 2018 Submitted to Department of Business and Professional Regulations Office of Codes and Standards

5W LED Energy Saver PIR Bulkhead

3/6/2018. Design Tips For Fire and Smoke Barriers. Professional Development Hours (PDH) Certificates. Copyright Materials

Indoor climate systems in passive houses

Occupants experiences in dwellings with different LT heating systems

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

MICROCLIMATE SYSTEMS CHARACTERISTICS OF A THREE FLOOR HOTEL IN VILNIUS

EMBEDDED PIPE SYSTEMS. SURFACE HEATING AND COOLING Heat transfer coefficient COOLING CAPACITY. Max. heating-cooling-capacity

Heating and Comfort Policy. Reviewed April 2014

Computer Modelling and Simulation of a Smart Water Heater

(a) (i) Complete the following sentences using words from the box. The warm air rising from the heater transfers energy to the

Museum of Bavarian History Regensburg, Germany

Verification Report SolarVenti SV14 Danish Technological Institute Refrigeration and Heat Pump Technology J.no Test no.

The Unplanned Impacts On Houses By Powered Attic Ventilators

Connect North and South Korean Separated Families Higher Comfort Lower Energy

SilverScreen. The innovation in solar heat and light control

Certified Passive House Component For cool, temperate climates, valid until 31 December 2017

Appendix A Equipment Used to Monitor Hotels

Influence of different surface systems and humidity-controlled ventilation systems with heat recovery on the indoor climate in flats

Japanese Case Study: How to maintain the fire safety in subway station and tunnel

Energy Efficiency Standards

August 15, 2013 Page 1 of 19

Heat pump supplemental heating system for motor vehicles

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

PERFORMANCES OF DAHT CONNECTED TO BUILDING AIRTIGHTNESS AND INDOOR HYGRO- THERMAL CLIMATE

Improved occupancy detection accuracy using PIR and door sensors for a smart thermostat

Assigning profiles to a Breathing Buildings NVHR Unit (NVHR900 & NVHR1100)

Assessment of Domestic Evacuated Tube. Direct Solar Water Heater

1. COOL ROOFS. What is a Cool Roof

Performance evaluation of residential ventilation systems based on multi-zone ventilation models.

Q1. The diagram shows an experiment to find out what happens to infrared waves when they strike different surfaces.

EVALUATION OF THE THERMAL PERFORMANCE OF METAL ROOFING UNDER TROPICAL CLIMATIC CONDITIONS

Transcription:

Seventh International IBPSA Conference Rio de Janeiro, Brazil August 13-15, 2001 SIMULATION OF DEMAND CONTROLLED VENTILATION IN A LOW-ENERGY HOUSE Netherlands Energy Research Foundation J.C. Römer P.O. Box 1 1755 ZG PETTEN, The Netherlands ABSTRACT In low energy dwellings the ventilation heat losses are significant. Reducing this heat losses can be done by introducing demand controlled ventilation i.e. ventilating at a normal rate only when rooms are occupied. Simulations, using TRNSYS 14.2, of a dwelling, equipped with a demand controlled ventilation system are carried to determine the extra conservation on natural gas for space heating. Demand controlled ventilation schedules are used in the simulation program by using typical Dutch occupation schedules of a four person family for the dwelling. Preliminary results indicate an extra energy conservation of 15-20% with regard to the reference situation. INTRODUCTION In order to reduce the CO 2 exhaust from burning natural gas for spaceheating, the Dutch government has set limits to the energy consumption in new to build dwellings, offices and other utility buildings. Depending on that size new dwellings will not get a building permit if its energy consumption for space heating and hot water production exeeds 800 m 3 of natural gas. At the ECN test location near Petten in the Netherlands, four typical Dutch dwellings were built to demonstrate the possibility of building houses of which the energy required for space heating can be reduced to 50% of this prescribed amount with low additional building costs. Figure 1 gives a view of the project. Figure 1: Low energy dwellings testsite The four buildings are equal in size but differ in the used installations for space heating and in building mass. Two houses on the left do have heavy concrete walls and floors while the two buildings on the right are, with exception of the ground floor, timber build houses. The facade of this complex is oriented North-South for a maximum heat gain from the sun in wintertime. Much attention is paid to reduce the heat losses from roofs, floors and facades. This is done by using 20 cm of isolation resulting in a heat resistance of 5 K/m 2. W. Heat losses through the glazing are reduced by using windows with a U- value of (depending on the building) < 1,1 W/m 2 /K In most of the dwellings in winter time mechanical ventilation is used with a 90% heat recovery Space heat is in two dwellings provided by heat pumps, two dwellings have high efficiency gas boilers (efficiency >90%). No occupants are planned in the buildings in the near future. MEASURING SYSTEM All dwellings are equipped with an extensive measuring system. In all rooms room temperature and air humidity is measured and stored in databases for analysing. The heat flow in the heat supplying systems (radiators and floor heating system) is measured as is the total amount of heat supplied by the gas boiler. Weather data (wind speed, wind direction, ambient temperature, solar radiation and relative humidity are measured in the vincinity of the test facility and stored for analyses. TEST PROGRAM For the next two years an extensive testing program will be carried out at the testside. From all four dwellings the heat balance will be calculated from measured data. The different installations will be monitored. Test data will be used for several projects including a validation project in which several building simulation programs will be evaluated against measured data. The effects of occupancy is simulated by electric heaters and air humidifiers, controlled by the data acquisition system. The results will be used to verify wether to target of 50% primary energy reduction was reached and to specify further measures for energy conservation. The monitoring servers as an assessment of the equipment efficiency and as an aid to better simulate the dynamic behaviour of systems plus building. - 611 -

TEST BUILDING The building on the near right is totally constructed from timber, with exception of the ground floor and the first floor on which a concrete layer has been laid because of the floor heating system. Beside the floor heating system heat to the rooms is supplied by radiator elements. A high efficiency gas boiler supplies the heat to these systems for space heating. Each room has its own room thermostat to control the room temperature and the flow of hot water for space heating is turned of by a thermostat valve All windows have double glazing wherby the total U- value is 1,1 W/m2.K. detected ventilation valves are opened so that the prescribed levels are reached. Movement is detected by a Passive InfraRed detector, located in one of the corners of each room. Data are send to the room controller in the vicinity of the PIR detector which is connected to the home network. Figure 3 gives an impression of room controller and PIR movement detector. Element Construction U-value Ground Cover layer, 0.16 Floor concrete, External walls Internal walls Roof insulation Woodplates, Gipsum plate, insulation, gipsum plate Gipsum plate, insulation, gipsum plate Woodplate Isulation, woodplate, rooftiles 0.17 0.49 0.13 Windows Double glazing 1.1 Table 1: Fabric elements of building used in simulation All outside construction parts (groundfloor, roof, and facade have a U-value of 0,2 W/m 2. K resulting from the 20 cm of isolation. Figure 2 Roomcontroller and PIR detector Ventilation rates are also switched to a higher level if air humidity in the room is in excess of 70% The natural supply and exhaust system is based on the outside wind flow. The test location is situated in the North-West part of the Netherlands where wind directions is mainly south to south west as shown in the next figure. N VENTILATION SYSTEMS The ventilation systems consists in fact of three subsystems: - Mechanical supply and exhaust in winter time with 90% heat recovery. - Natural supply and exhaust in summer time through windows in the facades at the south- and north orientation. - Natural supply and mechanical exhaust in times that the outside wind can not create sufficient air flow in the rooms. W O All ventilation system are controlled by the home network which is installed in the dwelling. For the balanced mechanical ventilation system in wintertime, ventilation rates are controlled by detection of movement in the rooms. If no movement is detected supply to and exhaust from rooms is kept at such a level that the air quality remains acceptable (temperature, air humidity). If movement in a room is Z Figure 3.: Distribution of measured wind direction in NW Holland in 1996-612 -

*Data taken from the Dutch reference year, reveals that in summertime about 24% of the time the wind speed is less than 3 m/sec. In that case natural supply and mechanical exhaust will be used to establish sufficient ventilation in the rooms. Window opening for natural ventilation in the rooms is regulated on basis of the outside wind speed. Windows are opened between 3 m/sec and 10 m/sec whereby the opening is based on the outside windspeed. If the wind speed is less than 3 m/sec or greater than 10 m/sec then the exhaust fan is turned on and window opening is adjusted according to the wind speed. The window openings will always be adjusted in such a way that air velocity in the living room never will exceed 0.2 m/sec. Room Ventilation rate (ACH) Supply Exhaust From To other outside rooms Living room 0.5 0.36 0.14 Sleeping room 1 0.3 0.3 0.3 Sleeping room 2 0.2 0.2 0.2 Sleeping room 3 0.3 0.2 0.3 Table 2: Air flow and supply source Room Ventilation rate (ACH) Exhaust Supply To outside From other rooms Kitchen 2.5 2.5 2.5 Toilet 8 8 8 Bathroom 3 3 3 Table 3: Air flow and exhaust source Figure 4: Automatically opened passage between living room and corridor for natural based ventilating system For a building of this size the following values for mechanical ventilation rates are prescribed by the Dutch Building law: Exhaust values - Kitchen : 75 m 3 /hour - Bathroom : 50 m 3 /hour - Toilet : 25 m 3 /hour Supply values - Living room : 50 m 3 /hour - Sleeping rooms : 100 m 3 /hour The maximum infiltration rates may not exceed a prescribed level. For buildings with a maximum volume of 500 m 3 the leakage rate must be less then 0.2 m 3 /hour (720 m 3 /hour) measured at 10 Pa wind presure. For this building blower door tests were carried out in the past. Some minor leakages were discovered and after repairing these leakage spots again blower door test will be carried out to determine the exact infiltration rates. In the groundfloor, using mechanical ventilation there are 2 supply ducts (in the living room) and two exhaust places (toilet and kitchen). The upper floor, bathroom and sleeping rooms, does have air supply in each sleeping room and an exhaust in the bathroom. DEMAND CONTROLLED VENTILATING SYSTEM Demand controlled ventilation in the heating season is implemented in the building by using movement detection in each room including the entrance of the building. If in a room movement is detected for a longer time than the room controller switches the room inlet/outlet ventilation valve in the ventilation system duct system from a minimum supply/exhaust rate to the rate required by the Dutch Building code Reducing the heat losses resulting from the necessary ventilation is implemented in two ways: By using heat recovery on the exhaust ventilation flow is a major step to reduce the overall losses of these low energy houses. Reducing the heat losses by demand controlled ventilation is a next step in rooms on presence. Normally building ventilation rates are 24 hours a day set at the prescribed level even if nobody is in the building. If the building or part of the building (living room or sleeping rooms) are not occupied the ventilation rate to that room can be reduced. At night time when everybody is asleep ventilation supply to the living room can be reduced and in daytime when nobody (normally) is present in the sleeping rooms the exhaust from that rooms can be reduced too. Supply rates can be reduced but room air humidity must be taken into account. Minimum supply rates should have a value so that air humidity in access of 70% is avoided. - 613 -

SIMULATION PROGRAM The TRNSYS 14.2 code was used for simulation calculations. In another project TRNSYS 14.2 and other simulation programs as ESPr, VA114, COMIS, ADELINE and Energy10 will be used to match simulation results with the measured data from the test facility. The simulation programs will not only be validated with measuring data but also the outcome of the different models will be compared with each other. WEATHER DATA For simulation purposes the Dutch Test Reference year is used as input data for the simulation model GROUND FLOOR BOUNDARY TEMPERATURE The temperature beneath the ground floor will fluctuate during the year. Depending on the heat conduction coefficient of the soil type beneath the building and the solar gains on the ground next to the building the temperature in the crawl space will very during the year. The dashed line in figure 5 represents the ambient temperature; the solid line is the temperature outside the groundfloor in the crawling space Temperature (degree C) 12 10 8 6 4 2 0-2 -4 1 3 5 7 9 11 Week 13 15 17 19 Figure 5: Temperature beneath ground floor during the first 4 month in wintertime INTERNAL GAINS Table 4 represents the internal heat gained by people, machines and lighting. These data are taken from a calculation model which is used in the Netherlands when a building permit has to be awarded. Different schedules are used for the living room and the sleeping rooms. The used values are mean values and are typical for Dutch situations. Time [hr] 7:00 till 17:00 17:00 till 23:00 23:00 till 7:00 W/m 2 W/m 2 W/m 2 Living (7 days) 8 20 2 Sleeping rooms 2 4 6 (2 days) Sleeping rooms (5 days) 1 1 6 Table 4: Internal heat loads used in simulation For the sleeping rooms a different schedule applies for weekdays and weekends HEATING SCHEDULE Time [hr] 7:00 till 17:00 W/m 2 17:00 till 23:00 W/m 2 23:00 till 7:00 W/m 2 Living (7 days) 19 20 15 Sleeping rooms 19 20 15 (2 days) Sleeping rooms (5 days) 15 15 14 Table 5: Heating schedule used in simulation For the sleeping rooms different schedules are alplied for weekdays and weekends Heating schedule is assumed to be active from 1 october till 30th of april each year. In the weekend for the sleeping rooms different schedules are applied. Heating power used in simulations is set at 36.000 KJ. VENTILATION AND INFILTRATION RATES Infiltration is kept to a minimum by using double sealings for doors and windows and much attention is paid to seal off the connections between facade and ground floor. Reference situation. In the reference situation ventilation rates are as prescibed by the Dutch Building Law. Day and night the amout of air chanfges per hour have the same values as shown in table 6. The ventilation system has the prescribed rate of some 300 m 3 /hour. Based on the Dutch building code the ventilation rates were determined to be 0,5 and infiltration rates were calculated at 0,2 air changes per hour. Heat recovery is applied with an efficiency of 90%. With this inputs the heat balance is calculated by the program. This with be the reference case. Results with the demand controlled ventilation will be compared with this data. - 614 -

Ventilation Rate (ACH) Location Day time Night time Living room 0.5 0.5 Kitchen 2.5 2.5 Toilet 8 8 Entrance 0.3 0.3 Bathroom 3 3 Sleeping room 0.6 0.6 South large Sleeping room 0.5 0.5 South small Sleeping room North 0.6 0.6 Table 6: Ventilation rates used for simulation of the reference state For simulations with demand controlled ventilation 2 cases were calculated: Case 1: Night time reduction: ventilation rates at the ground floor at night ( from 23.00 07.00 hour) are 50% less than during daytime hours. For the sleeping zone rates during daytime are 50% less than during night time. Case 2: Occupancy reduction: Based on common pattern of using the dwelling by a 4 person family presence in the different rooms (living room, kitchen, toilet, bathroom and sleeping rooms) is determined. No presence in a room means that the ventilation rates are lowered to 50% of the rates at room presence. Ventilation Rate (ACH) Location Day time Night time Living room 0.5 0.25 Kitchen 2.5 1.25 Toilet 8 4 Entrance 0.3 0.15 Bathroom 3 1.5 Sleeping room 0.3 0.6 South large Sleeping room 0.2 0.5 South small Sleeping room North 0.3 0.6 Table 7: Ventilation rates demand controlled ventilation case 1 (night time reduction) RESULTS Reference case: continious ventilation rates during day and night Based on the room volume the Dutch Building code the ventilation rates in the rooms are shown in table 6. Simulations carried out with the above mentioned values for the reference case, i.e. the ventilation rates as prescribed by the building code. With these values a yearly heat demand of this building of 15.1 GJ was calculated. The overall heat balance of the dwelling is presented in the next figures. The heat balance consist of the following parts: Figure 6: Reference case heat balance (%) Gains: - Incoming solar radiation - Internal gains - Heat demand Losses are: - Ventilation losses - Infiltration losses - Transmission losses Ventilation Infiltration Internal Gains Solar heat Heat demand Transmission losses HEAT RECOVERY In table 5 the heating schedules of the dwelling are shown. No heating is applied to the sleeping rooms during daytime hours in the first 5 days of the week. The outlet air from this rooms will be mixed (via the exhaust in the bathroom) with the warmer air from the ground floor at the inlet pipe of the heat recovery unit. Simulations where carried out to see the effect of this mixing on the fresh supply air to the sleeping rooms. Temperatures of the supply air to the rooms is calculated based on room temperature and outside temperatures: From each floor the air temperature to the rooms is determined by: Tsupply = Ta+ 0.9*(Troom- Ta). - 615 -

Whereby Ta is the ambient temperatures as read by the simulation program, Troom is the room temperature as determined by the program and Tsupply is the new supply temperature of fresh air. Due to the fact that the exhaust from the ground floor is mixed with the exhaust form the first (sleeping) floor and the heating schedule in the sleeping rooms differ during weekdays from that of the ground floor rooms and then fed to the heat recovery unit, one might expect that the sleeping rooms are slightly heated up by the relatively warm supply air. Simulations where carried out to see if that is true Ventilation Infiltration Internal Gains Solar heat Heat demand Transmission losses 18 17 16 15 14 13 1 3 5 7 9 11131517192123 Figure 7: Inlet air temperatures rooms The thick line in figure 7 at the top of the figure represent the temperatures of the inlet air if the exhaust air from the ground floor and the sleeping zones are mixed and fed to the heat recovery unit. The thinner lower line is the air temperature to the sleeping zone if it had an own heat recovery unit. From this figure it can be concluded that in case of a mixure of warm exhaust air form the ground floor and colder air from the sleeping zone the sleeping zones will be warmed up a little bit. In case of a mixed flow the temperature of the air entering the sleeping zones is at maximum 3,5 o C. higher then with a separate heat recovery unit for this zone. This results in fact in a slow heatup of the sleeping rooms. DEMAND CONTROLLED VENTILATION CASE 1 Simulation carried out with to 50% reduced ventilation rates during daytime or nighttime revealed an annual heat demand of 13.0 GJ. This means an annally energy conservation of nearly 15% Figure 8: Reduced ventilation case heat balance (%) DEMAND CONTROLLED VENTILATION CASE 2 To investigate if demand controlled ventilation during daytime, when using living room, kitchen and in the morning leads to an additional energy conservation, the occupation of the rooms must be determined. Furthermore the type of occupants must be determined. It is determined that the occupants of the dwelling is a 4 person family (2 adults and 2 children). Room occupation: Kitchen 07.00 08.00 17.00 19.00 Living room 07.00 23.00 Bathroom 06.30-08.00 22.00-23.00 Sleeping room 1 23.00-06.30 Sleeping room 2 22.00 07.00 Sleeping room 3 21.00-07.00 Toilet *) *) The effective occupation time i.e. the time during a day that an increased ventilation rate is necessary has been determined as 1 hours daily. During this time the ventilation rates are increased to the prescribed levels and during the unoccupied times the levels are 50% lower assuming this ventilation rates are sufficient to keep the air quality at an acceptable level. These values are used for calculations. The outcome of this calculations are that an extra 5% of energy conservation is achieved compared to the reference case ( 0,5 GJ). - 616 -

CONCLUSIONS A growing number of new built dwellings in the Netherlands are equipped with balanced ventilation with heat recovery (upto 10% in 2000). New to build dwellings are subjected to strong energy consumption rules. Even with this strong rules and low energy dwellings it is possible to reduce the energy demand of the building even more. The major losses in this type of buildings are the ventilation losses. Reducing them, even after using heat recovery, is possible by introducing demand controlled ventilation. Demand controlled ventilation means that the ventilation rates in the different rooms are only switched to the prescribed levels if the occupants are in the rooms. consumption will be determined. In the next winter season the occupancy controlled ventilation will be subject of experiments. Air quality during this experimenst will be monitored. Final results are expected to be available at the end of 2002. ACKNOWLEDGEMENTS This project is financially supported by the regional government of the Northern Netherlands. Much help in the construction of the ventilation systems used was received from mr. De Graaff of StorkAir. The author further wishes to express his gratitude to dr. Wim van Helden for his advices during the work. In this reseach, using the thermal simulation model TRNSYS 14.2 the energy conservation is calculated to be some 15%. If daytime and nighttime ventilation rates are reduced to 50% of the prescribed level and even to some 20% if use pattern of rooms (bathroom, toilet and kitchen) are introduced. The energy conservation reached strongly depends on the heating schedules used. In this reseach the common Dutch habit to only heat the sleeping rooms during evening or weekend times was used. The energy conservation calculated is the decrease in heat demand of the building. Not taken into account is the electricity used to operate the home network which controls the ventilation systems. Research in the years to come will reveal the actual value for this electricity use. At this moment it is estimated to be some 200 kwh a year, roughly corresponding with 1,44 GJ. Putting demand controlled ventilation into work sets some constraints on the ventilation system. In balanced ventilation systems the exhaust fan controls the output of the supply fan. They act in balance. Reducing the opening of an exhaust valve will therefore reduce also the supply to the sleeping rooms or the living room. For demand controlled ventilation systems the ventilation rates should always be sufficient enough to ventilate rooms not in use The control of the exhaust rates and the supply rates should therefore be determined on basis of the pressure in the ducts near the heat recovery unit. In this case closing an exhaust valve or a supply valve will not influence the rest of the system. Another result from this study is that, when sleeping rooms during daytime are not heated with the same schedule as the living room, the balanced ventilation system will slowly heat up the sleeping rooms during day time. During the next two years, experiments will be carried out to determine the heat balance of the building during the different seasons. First the reference situation heat balance (continious ventilation air supply) will be measured. Electricity - 617 -