Steam Fundamentals. (in heating & processing applications)

Similar documents
A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

BURNER MANAGEMENT CONTROLS

OPERATING AND MAINTENANCE MANUAL

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

Power Flame Incorporated

Eclipse Self-Check UV Scanner

ED510 DISPLAY MODULE. FOR USE WITH FIREYE FLAME-MONITOR AND MicroM BURNER MANAGEMENT CONTROLS DESCRIPTION INSTALLATION APPROVED

MULTIPLEX SELF RECUPERATIVE gas burner

Burner Comparisons. Typical Competitor s Burner

Boiler Basics. Design and operation

Refer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System.

LFL Series Burner Flame Safeguard Control

Document code: 1 (10) Issuing date: Status:

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

.2 Section Waste Management and Disposal..4 Section Vibration Isolation and Seismic Control Measures.

Type CG Series Forced Draft Gas Burner

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

E110 FIREYE FLAME-MONITOR BURNER MANAGEMENT CONTROL FOR USE WITH THE MICROPROCESSOR-BASED EP AND EPD STYLE PROGRAMMER MODULES

Chemical Processes in the Combustion

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION

Indirect gas-fired air heater

FIREYE E210/211 FLAME-MONITOR

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

FIREYE FLAME SAFEGUARD CONTROLS DESCRIPTION

Eclipse 90 UV Scanner Model A Version 1

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

INDUSTRIAL MICRODIFFUSION OIL BURNERS

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Unitech Combustion.

INDITHERM. Low temperature gas burners

ENVI Boiler Controller

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

STEAMPAK Series BurnerPAK BMS Burner Management Systems

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

SC Series Forced Draft Burners

5.0 ALARMS & TROUBLESHOOTING

HCLEARFIRE. High-efficiency, modular steam boiler HP

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

R-Series Oil Burners. Riello Burners a world of experience in every burner we sell. Reliable Combustion Solutions

IE059: Boiler Control and Instrumentation for Engineers & Technicians

Bert Uneken, Field Engineering Manager Ruben Kranenburg, Technical Support

Power Flame Incorporated

Presented by Moises Rodriguez Cleaver Brooks Sales & Service, Inc.

DIVISION FINNED WATER-TUBE WATER HEATERS

Specifications of V-Line burners

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

FUEL-FIRED VERTICAL TUBELESS BOILERS

Single stage operation oil burner

Flame Safeguard Fault Code Diagnostics

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER

Figure 10 or Figure 6

MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel.

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

SECTION WATER-TUBE BOILERS

Presentation On Industrial Boiler Operation And Maintenance

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

SECTION HEATING BOILERS

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

INDITHERM. Low temperature gas burners

DIVISION FINNED WATER-TUBE BOILERS

Heating Maintenance and Repair

DIRECTIVE NO: D-B

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

Burner Management and Combustion Control. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.

"HC" AIRFLO. In-duct firing line burner

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Fuel-Fired Vertical Tubeless Boilers

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

S. P. THERMAL SYSTEMS INC.

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

ECLIPSE INFORMATION GUIDE

Cleaver-Brooks Webinars

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

Direct Fired Heater Model AD Specification

WATER-TUBE POOL HEATERS

FLAME SAFEGUARD & COMBUSTION CONTROLS. Preface

Complete Boiler Management in a Compact, Affordable System

Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA

STR-Series Indirect-Fired Air Turnover Units

Diocese of Cleveland Facilities Services Corporation

Model Universal Oil Primary Control

Complete burner management in a compact, affordable system

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

GP COMBUSTION EQUIPMENT INC 100 Sheldon Dr., Units 16/17 Cambridge, Ontario N1R 7S7. Model C Forced Draft Burners. Natural Gas or Propane MODEL C10

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

Power Flame Incorporated

WATER-TUBE POOL HEATERS

PACKAGED METALLIC BURNERS

Waste/Multi Oil Boilers from Flexiheat

SULPHUR RECOVERY UNIT

DIVISION FINNED WATER-TUBE BOILERS

D-GF 150. Burner Control for Gas and Oil Burners Flame Sensor D-GF 150 D-LE 103

Distributed By: M&M Control Service, INC

Beyond The Barriers of Performance Through Sound TM

Solid State Burner Management Controls Series D10-20 for Automatic Burners

Transcription:

Steam Fundamentals (in heating & processing applications)

Introduction

Common Heat Energy conveyers: Thermal Oil Hot water Steam Electrical Electric Heaters Electrodes (High Current)

Steam Fundamentals Why using steam? Steam is efficient & economic to generate Water is inexpensive, non hazardous to health and environment Stem can hold 5~6 times as much potential energy as an equivalent mass of water It can be generated at high pressure to give high temperature Lower capital cost and running cost

Steam can easily and cost effectively be distributed to the point of use Steam is one of the most widely used media to convey heat over distances No circulation pumps are needed to move steam in the network Due to high heat content, relatively small pipe size is required to carry the steam at high pressure.

Steam is easy to control Temperature can be easily and accurately controlled by controlling the steam pressure Only 2 port control valve is needed to control the steam line

Energy is easily transferred to the process Steam provides excellent heat transfer properties Steam can surround or be injected into the product being heated Because of high heat transfer properties, the required heat transfer area is relatively small

Steam is flexible It is used for sterilization in food and pharmaceutical industries It is also used in humidification

Comparison of common heating media with steam

Barriers to Heat Transfer: Air film, condensate, scale, on the steam side, plus heat exchanger wall, and stagnant film of product to be heated are the common heat transfer barriers.

Temperature gradients across heat transfer layers

Layers That Reduce Heat Transfer Efficiency Steam 4 bar 151 C 0 0 125 C 0 121 C Condensate Film Scale Film Metal Wall 93 0 C Water Being Heated 0 120 C 0 116 C Fouling layers 0.25 mm thick

Boiler Fundamentals

Steam Boiler Types Packaged Boilers Packaged boilers are limited to 25Ton/Hr capacity and 17Bar pressure. Mainly there are 3 types of packaged boilers: fire tube boilers, vertical boilers, and reverse flame boiler. Site assembled boilers. (Or water tubes Boiler) water tube boilers are used mainly in power generation or wherever high pressure and/or high steam capacity is required.

Typical Packaged Steam Boiler

3 Pass Steam Boiler Steam at 150 o C 200 o C 250 o C 3rd Pass (Tubes) 2nd Pass (Tubes) 400 o C 1600 o C 1st Pass (Furnace Tube(s))

Typical Heat Transfer Data for a 3 Pass Boiler For 100 m 2 Heating Surface (Total) % Heat Transfer 1st Pass - Furnace 11 m 2 : 1,600 o C 65 % - Combustion chamber 2nd Pass 43 m 2 : 400 o C 25 % 3rd Pass 46 m 2 : 250 o C 10 %

Reverse flame or thimble boiler Water Steam Chimney Burner Thimble furnace Steam Space Furnace back wall Tubes around furnace

Steam Generator (Vertical Boiler) Burner Steam Outlet Water Combustion Chamber 1 st Pass, Downward Finned Convection 2 nd Pass, Upward

Coil Boiler Flame Q kg/h Dry saturated steam to plant 10% water with impurities to waste/recycle Q kg/h + 10%

Pendant Superheater Water Tube Boiler Steam Drum Convection Bank Gas Baffles Economiser Burners

Boiler Fittings

Boiler Fittings There are a number of attachments and fitting on a boiler. The objectives of these fittings include: Operation. Safety. Efficiency. Compliance with laws, regulations and guidance notes.

Feed Water System

Feed Tank Stop Valve Feed Check Valve Feed Pump Boiler

Feed Tank Purposes: Receives condensate from the network Storage reasonable amount of water to cover boiler feed demand Remove oxygen and incondensable gasses Preheat the feed water to prevent thermal shock

Feed Tank Components

Deaerator Head

Boiler Inside Video

Boiler Control & Burner Management

Burner Requirements: provide high combustion efficiency follow steam demand load Easy to start Simple and easy to maintain Provide highest safety level

Burner Components Blower Motor, Blower Air Damper and Turbulator Oil Pumps, Oil Valves, Metering Valve, Nozzles (For Oil Burner) Gas Train, Gas Solenoid Valve, Butterfly metering valve, and Gas nozzles (for gas burners) Ignition Transformer and Electrodes Pilot assembly Flame Scanner and Burner Controller Modulation Motor and Linkages

Burner Controller Burner Management Sequencing of StartUp Sequencing of Shutdown Monitoring of Interlocks Fuel Pressure /Temperature Air Pressure Flame Safeguard Monitoring of the Flame presence/absence

Flame Scanners Photo cell (visible light scanner) Ultra-Violet (UV) Infrared (IR) IR + UV

Oil Burner Flow Diagram

Burner Sequence Initialization : 5 secs, self test Purge High Fire Purge 30 sec Low Fire Purge 30 sec PTFI (Pilot Trial For Ignition) Ignition spark (5 sec) Oil Valve (10 sec) MTFI : 10 sec (Main Trial For Ignition) AUTO Post-Purge : 15 sec Standby One CYCLE!

Burner Firing Sequence 1- On/Off 2- low, high, off system 3- Full Modulation