Content ⅠBrief introduction...1 XD-301-2-150W/250W Medical Cold Light source USER MANUAL II. Performance Summarize...1 III Main technical parameters...1 IV Security tips and symbols...2 V Working Environment...2 VI Product listⅦ. Product interface...2 Ⅷ Operating instructions...3 Ⅸ Failure Judgment and Eliminating Methods...3 Ⅹ Note and instructions...3 Ⅺ Replacement of bulbs...4 ⅩⅢAfter-sales service warranty...5 Ⅻ Transportation and storage conditions...5 Ⅹ Ⅳ Electrical schematic diagram and components list...6
Ⅰ.Brief introduction XD-300-150W/250W medical cold light source, as the supporting of light source and other equipment, is used for deep lighting like clinical examination, operation treatment etc. II. Performance Summarize 1.The cold light source adapts to wide range voltage. Both the output voltage and the bulb intensity of illumination, color temperature keep constant stable when the network voltage in 198 V-242 V fluctuation change. There is no need to use a voltage stabilizer and extend the life of the bulb. 2. Brightness adjusting linear is excellent from strong to weak. 3. The light source is strong in anti-interference. It will neither interfere other equipment nor be interfered by other equipment. It overcomes the defect that the silicon controlled circuit is easily influenced by net electricity and other sensitive equipments. 4. The design and production of this light source strictly executes the first part of the safety requirements of medical electrical equipment GB4793.1-2007: general requirements which is guaranteed in safety. III Main technical parameters 1. Input voltage: AC 110V/220V 50Hz-60HZ 2. Halogen bulb: 24V/150W 24V/250W 3. Input power of 150W: 220W 4. Input power of 250W: 400W 5. Illumination of 250W light source: 2500000LX 6. Illumination of 150W light source: 1600000LX 7. Color temperature: 3600k±500k 8. Fuse protector: 3A- 5 IV Security tips and symbols 1. In order to reduce fire, electric shock or personnel risk of injury, we should always obey the basic safety precautions in use. 1 Please read the instructions carefully and operate it in accordance with manual operation. 2 When replace the bulbs, you must first turn off the power switch of the light source and pull out the power cord. 3 Replacement of the fuse protector should be the same with the requirements of the following mark. 4 The light source mustn t be used directly for eyes. 2. The introduction of the following symbols Attention! Check the random documents Protect the grounding Disconnect the power V Working Environment A. Environmental temperature: -10 ~+40 B. Relative humidity : 75% C. The atmosphere: 86.0~106.0kPa VI Product list Main engine of light source: one Power line: one Connect the power
Ⅶ. Product interface XD-301-2-150W/250W 1. Power switch 2. Output brightness adjusting knob 3. The optical fiber interface of light output 4. Option switch Ⅷ Operating instructions 1. Confirm the power supply to have a good grounding attachment. 2. Open the power switch (1) and the light source begins to work. 3. Adjusting knob (2) can control the output size of light source. 4. (3) is the light output hole and is also the connection of optical fiber. Double orifice light source should be connected with the bulb. Ⅸ Failure Judgment and Eliminating Methods (It should be operated by the professionals) Fault phenomena Fault cause Solution Turn on the power switch, the indicator is not bright, fan does not turn, the lamp is not bright. Power lines have no electricity The power cord is not connected well Fuse damage Connect to the circuit where there is electricity supply Reconnect the power cord Change the fuse Turn on the power Brightness adjusting Transfer the switch, the indicator is button (3) is not open brightness adjusting bright and the fan button to the works well, but the maximum lamp is not bright. Bulb damage Change the bulb System line fault Contact with the after-sale service department for solution Other fault Contact with the after-sale service department for solution Ⅹ Note and instructions 1. The cold light source should be placed on a stationary area with aeration during operation. The distance between the fan hole on the back of the case and the back shelter should be 15cm. 2. Patients are not allowed to touch the cold light source during operation. 3. You are forbidden to look at the optical cable end or light outlet directly with your eyes to avoid damage to them after the cold light source is switched on. 4. Do not put other articles on the machine during operation. 5. The cold light source shouldn t be violently vibrated. Move it gently. 6. The cold light source should be placed on a dry area with aeration and covered by shields. 7. The cold light source should be sterilized with an UV sterilizing lamp regularly. 8. There is high voltage circuit in the machine, non-professional
personnel shall not open the box. Ⅺ Replacement of bulbs 1. When replace the bulb, you should choose the same model halogen bulbs. 2. Turn off the power switch and pull out the power cord. 3. 1Loose the screw of the bottom,open the cover,cover,bulb and bulb holder,remove the cover, 2Pull out the base of bulb, 3Pull out the damaged bulb from the lamp holder, install the new bulb and screw down the screws. Show as the following picture. wetting, etc. is not within the scope of warranty. Once receiving the goods, please sign and accept it after opening the package to inspect and confirm whether the instrument is crushed, scratched or not. Make sure there is no special unnumbered inside. If the goods are damaged and you did not inspect before sign it, It will be at your own risk. ⅩⅣElectrical schematic diagram and components list 1 2 3 Ⅻ Transportation and storage conditions Environmental temperature: -40 ~55 Relative humidity : 70% The atmosphere: 50Kpa~106Kpa ⅩⅢAfter-sales service warranty Warranty of 18 months, provide maintenance service all user s life. In the warranty period, in normally using, the trouble because of the product quality, the consumer depends on the warranty slip and invoice enjoys free maintenance service. If the error caused by remodel or install other functions which is without our company s permission, is not within the scope of warranty. If the model, number, release date is modified, deleted, moved or illegibility, will not enjoy the maintenance service. The error caused by human factor such as falling, squeezing, dip in, N0. Material name Specification Quantity Remark 1 Circuit board 7D1A 1 2 Field-effect tube SL20C20U 1 3 Filter choke 220mH 1 4 Inductance 470mH 1 5 Capacitance F103M/2KV 3 6 Capacitance 22nj/T100V 1 7 Capacitance 102M/2KV 1 8 Electrolytic capacitor 50V/1uf 1 9 Capacitance 222J/250V 1
10 Capacitance 102J/100P 1 11 Electrolytic capacitor 50V/4.7uf 3 12 Electrolytic capacitor 50V/22uf 1 13 Electrolytic capacitor 50V/47uf 1 14 Electrolytic capacitor 50V/1000uf 2 15 Electrolytic capacitor 250V/470uf 2 16 CBB capacitor 400V/105J 1 17 Filter capacitor 0.1uf 2 18 Resistance 150K/0.25W 1 19 Resistance 15Ω /0.25W 2 20 Resistance 120KΩ /0.25W 1 21 Resistance 12KΩ /0.25W 1 22 Resistance 10KΩ /0.25W 1 23 Resistance 1KΩ /0.25W 1 24 Resistance 22KΩ /0.25W 1 25 Resistance 15KΩ /0.25W 1 26 Resistance 5.6KΩ /0.25W 2 27 Resistance 560Ω /0.25W 1 28 Resistance 1.2KΩ /0.25W 1 29 Resistance 3.9KΩ /0.25W 1 30 Resistance 680KΩ /0.25W 1 31 Resistance 1.5KΩ /0.25W 1 32 Resistance 100KΩ /0.25W 1 33 Resistance 4.7KΩ /0.25W 1 34 Resistance 220Ω /0.25W 1 35 Resistance 150KΩ /0.25W 5 36 Resistance 2Ω /0.25W 2 37 Resistance 22K/0.25W 2 38 Resistance 24Ω /0.25W 2 39 Resistance 3.9K/0.25W 2 40 Resistance 100Ω /3W 1 41 Resistance 680Ω /3W 1 42 Diode F107 6 43 Diode IN4752 2 44 Diode IN4148 2 45 Audion 1815 3 46 Thermistor 5D-15 1 47 Piezoresistor 10D471K 1 48 Integrated circuit LM494 1 49 Rectifier bridge KBU810 1 50 Halogen lamp 150VA/250VA 2 51 Fan Φ 80 2 52 Power socket 1 53 Power line 1 54 Fuse block 2 55 Power switch 1 56 Sticker 1 57 Scutcheon 1 58 Case 1 Any products may be updated or improved. The change of circuit or element specifications of the product will not with prior notice. 2012 edition
Warranty card Company name: Address Product name Serial Number Sale date Fault description: Model Manufacture date Phone No. Remark: The warranty of our products is 18 months since the release date. (Please truthfully fill in this form, cut it according to the dotted line and send it back to our company, thank you for your cooperation) Maintenance card Company name: Address Product name Serial Number Sale date Fault description: Model Manufacture date Phone No. Remark: You can enjoy seventy percent discount for the maintenance services even if you use this card over the quality assurance period.