Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Similar documents
Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. Dimensions

Inductive slot sensor

PEPPERL+FUCHS GmbH

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

EU DECLARATION OF CONFORMITY

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Operating Instructions Edition 02/2007

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Operating Manual MS220KA and MSR220KA

4) Intrinsic Safety Certification

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

MANUAL Oil Level Sensor

VERSAFLOW VORTEX Supplementary instructions

Operating Manual MS220DA

Installation and Operating Instruction

Retroreflective sensor with polarization filter

OPTIBAR DP 7060 Supplementary Instructions

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

OilSET-1000 (12 VDC)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

INSTRUCTION MANUAL (ATEX / IECEx)

AND INSTALLATION MANUAL

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF...

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF...

OPTIBAR P 1010/2010 C Supplementary instructions

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

InductIve SenSorS 2018

Gas cylinder scale Model GCS-1

SET Installation and Operating Instructions. Level switch for one sensor

PROTECT SRB 200EXi-1A

FACTORY AUTOMATION. Instruction Manual NBB20-L2-E2B-C-V1 NBN40-L2-E2B-C-V1 Inductive Sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Annubar Flowmeter Series

SEK-3 Marine Grounding System

BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13

Temperature Measurement Transmitters for field mounting

INSTRUCTION MANUAL (ATEX)

INSTRUCTION & SERVICE MANUAL

BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13

DB5 Intrinsically Safe Sounder Type DB-5

Installationsmanual GWSL1100/2100, GWML3100

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

SET-2000 Oil/Sludge 12 VDC

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

SET-2000 Hi Level/Oil

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Dräger Polytron (approved as type P3S) Transmitter for electrochemical Sensors. Instructions for Use. ST eps

CARLO GAVAZZI Automation Components. CA18/30 CAN/CAF - Capacitive Sensors

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Datasheet - MZM 100 ST-SD2PREM-A

Continuous Gas Analyzers AO2000 Series AO2040-CU Ex Central Unit in Category 2G. Operator s Manual 42/24-13 EN Rev. 3

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

Datasheet - MZM 100 B ST2-SD2PREM-A

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

M7100 Pressure Transducer

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

SensaGuard TM Integrated Latch Installation Instructions

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

Supplementary Installation and Operating Instructions. Category II2G

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Model 144H. Product Data Sheet , Rev DB February Content

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

Additional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy

Datasheet - MZM 100 ST2-1P2PWREM-A

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

IECEx Certificate of Conformity

OPTIWAVE X500 Supplementary Instructions

Certificate of Compliance

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

OOH740-A9-Ex Multi-sensor fire detector

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Certificate of Compliance

OOH740-A9-Ex Multisensor fire detector

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Safety instructions VEGAPULS 64

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Transcription:

0102 Model Number Features Direct mounting on standard actuators EC-Type Examination Certificate TÜV99 ATEX 1479X Accessories BT32 BT32XS BT32XAS BT33 BT34 V1-G-N4-5M-PUR Female cordset, M12, 4-pin, NAMUR, PUR cable Technical Data specifications Switching element function DC Dual NC Rated operating distance s n 3 mm nstallation flush mountable Output polarity NAMUR Assured operating distance s a 0... 2.43 mm Actual operating distance s r 2.7... 3.3 mm typ. Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.1 Reduction factor r Brass 0.63 Nominal ratings Nominal voltage U o 8.2 V (R i approx. 1 kω) Switching frequency f 0... 1500 Hz Hysteresis H typ. 5 % Reverse polarity protection reverse polarity protected Short-circuit protection yes Suitable for 2:1 technology yes, Reverse polarity protection diode not required Current consumption Measuring plate not detected 3 ma Measuring plate detected 1 ma Time delay before availability t v 1 ms Switching state indicator LED, yellow Functional safety related parameters MTTF d 2070 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Ambient conditions Ambient temperature -25... 100 C (-13... 212 F) Storage temperature -40... 100 C (-40... 212 F) Mechanical specifications Connection type Connector M12 x 1, 4-pin Housing material PBT Sensing face PBT Degree of protection P67 Tightening torque, fastening screws M5 x 25 : 2.7 Nm Note Mounted on mechanical drive information Use in the hazardous area see instruction manuals Category 1G; 2G; 3G; 3D Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 EC 60947-5-6:1999 Electromagnetic compatibility NE 21:2007 Standards EN 60947-5-2:2007 EC 60947-5-2:2007 Approvals and certificates FM approval Control drawing 116-0165 UL approval culus Listed, Purpose CSA approval ccsaus Listed, Purpose CCC approval CCC approval / marking not required for products rated 36 V 1

Dimensions 20 Electrical Connection 23.75 47 15 40 5 5.3 52 35.4 30 21.2 M12x1 LED ø5.3 4.3 52 61 R20.8 45 45 N4 1/BN 3/BU 2/WH 4/BK + - + - 2

ATEX 1G Device category 1G for use in hazardous areas with gas, vapour and mist EC-Type Examination Certificate TÜV 99 ATEX 1479 X CE marking 0102 1G Ex ia C T6 T1 Ga Standards EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007 gnition protection "ntrinsic safety" Appropriate type NCN3-F25.-N4... Effective internal capacitance C i 100 nf A cable length of 10 m is considered. Effective internal inductance L i 100 µh A cable length of 10 m is considered. The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Directive and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 C was tested with regard to hot surfaces by the mentioned certification authority. f the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. Ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Note: Use the temperature table for category 1!!! The 20 % reduction in accordance with EN 1127-1:2007 has already been accounted for in the temperature table for category 1. Laws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Due to the possible danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation of the power supply and signal circuit is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of EC 60079-14 are met. nstall the device in such a way that the resin surface is not exposed to mechanical hazards. Protection from mechanical danger When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. Electrostatic charge When used in group C non-permissible electrostatic charges should be avoided on the plastic housing parts. nformation on electrostatic hazards can be found in the technical specification EC/TS 60079-32-1. Additional requirements for gas group C. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. 3

ATEX 2G Device category 2G for use in hazardous areas with gas, vapour and mist EC-Type Examination Certificate TÜV 99 ATEX 1479 X CE marking 0102 1G Ex ia C T6 T1 Ga Standards EN 60079-0:2012, EN 60079-11:2012 gnition protection "ntrinsic safety" Appropriate type NCN3-F25.-N4... Effective internal capacitance C i 100 nf ; a cable length of 10 m is considered. The value is applicable for one sensor circuit. Effective internal inductance L i 100 µh ; a cable length of 10 m is considered. The value is applicable for one sensor circuit. The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Directive and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 C was tested with regard to hot surfaces by the mentioned certification authority. f the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. Ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Laws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. nstall the device in such a way that the resin surface is not exposed to mechanical hazards. Protection from mechanical danger When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. 4

ATEX 3G (nl) Note This instruction is only valid for products according to EN 60079-15:2005, valid until 01-May-2013 Device category 3G (nl) for use in hazardous areas with gas, vapour and mist CE marking 0102 Standard conformity Effective internal capacitance C i Effective internal inductance L i Maximum permissible ambient temperature T Umax at Ui = 20 V for Pi=34 mw, i=25 ma, T6 for Pi=34 mw, i=25 ma, T5 for Pi=34 mw, i=25 ma, T4-T1 for Pi=64 mw, i=25 ma, T6 for Pi=64 mw, i=25 ma, T5 for Pi=64 mw, i=25 ma, T4-T1 for Pi=169 mw, i=52 ma, T6 for Pi=169 mw, i=52 ma, T5 for Pi=169 mw, i=52 ma, T4-T1 Protection from mechanical danger Protection from UV light Connection parts 3G Ex nl C T6 X EN 60079-15:2005 gnition protection category "n" 100 nf ; A cable length of 10 m is considered. 100 µh ; A cable length of 10 m is considered. The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! Laws and/or regulations and standards governing the use or intended usage goal must be observed. The sensor must only be operated with an energy-limited circuit, which satisfies the requirements of EC 60079-15. The explosion group complies with the connected, supplying, power limiting circuit. Each sensor circuit van be operated with the stated maximum values. The sensor must not be exposed to ANY FORM of mechanical danger. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. The connection parts are to be installed, such that a minimum protection class of P20 is achieved, in accordance with EC 60529. 5

ATEX 3G (ic) Device category 3G (ic) Certificate of Compliance CE marking Standards Effective internal capacitance C i Effective internal inductance L i Maximum permissible ambient temperature T Umax at Ui = 20 V for Pi=34 mw, i=25 ma, T6 for Pi=34 mw, i=25 ma, T5 for Pi=34 mw, i=25 ma, T4-T1 for Pi=64 mw, i=25 ma, T6 for Pi=64 mw, i=25 ma, T5 for Pi=64 mw, i=25 ma, T4-T1 for Pi=169 mw, i=52 ma, T6 for Pi=169 mw, i=52 ma, T5 for Pi=169 mw, i=52 ma, T4-T1 Protection from mechanical danger Connection parts for use in hazardous areas with gas, vapour and mist PF 13 CERT 2895 X 3G Ex ic C T6 T1 Gc EN 60079-0:2012, EN 60079-11:2012 gnition protection category "ic" 100 nf ; a cable length of 10 m is considered. The value is applicable for one sensor circuit. 100 µh ; A cable length of 10 m is considered. The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! Laws and/or regulations and standards governing the use or intended usage goal must be observed. The sensor must only be operated with energy-limited circuits, which satisfy the requirements of EC 60079-11. The explosion group depends on the connected and energy-limited supply circuit. nstall the device in such a way that the resin surface is not exposed to mechanical hazards. Each sensor circuit van be operated with the stated maximum values. The sensor must not be mechanically damaged. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. The connection parts are to be installed, such that a minimum protection class of P20 is achieved, in accordance with EC 60529. 6

ATEX 3D Note This instruction is only valid for products according to EN 50281-1-1, valid until 30-September-2008 Note the ex-marking on the sensor or on the enclosed adhesive label Device category 3D for use in hazardous areas with non-conducting combustible dust CE marking 0102 3D P67 T 111 C (231.8 F) X Standards EN 50281-1-1 Protection via housing The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to! Laws and/or regulations and standards governing the use or intended usage goal must be observed. Each sensor circuit van be operated with the stated maximum values. Minimum series resistance R V A minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier. Maximum operating voltage U Bmax The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted. Maximum heating (Temperature rise) Values can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv. at U Bmax =9 V, R V =562 Ω 11 K using an amplifier in accordance with 11 K EN 60947-5-6 Protection from mechanical danger The sensor must not be mechanically damaged. Plug connector The plug connector must not be disconnected under voltage. The proximity switch is marked as follows: "DO NOT DSCON- NECT UNDER VOLTAGE!" When the plug connector is disconnected the ingress of dirt into the inner areas (i.e. the areas, which are not accessible in the plugged-in condition) must be prevented. The plug connection can only be separated using a tool. This is achieved by using the locking protection V1-Clip (Mounting accessory from Pepperl + Fuchs). 7

ATEX 3D (td) Note This instruction is only valid for products according to EN 61241-0:2006 and EN 61241-1:2004 Note the ex-marking on the sensor or on the enclosed adhesive label Device category 3D CE marking for use in hazardous areas with non-conducting combustible dust 3D Ex td A22 P67 T80 C X Standards EN 61241-0:2006, EN 61241-1:2004 Protection via housing "td" The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The maximum surface temperature has been determined in accordance with method A without a dust layer on the equipment. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to! Laws and/or regulations and standards governing the use or intended usage goal must be observed. Each sensor circuit van be operated with the stated maximum values. Minimum series resistance R V A minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier. Maximum operating voltage U Bmax The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted. Maximum permissible ambient temperature T Umax tance Rv. Values can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resis- at U Bmax =9 V, R V =562 Ω using an amplifier in accordance with EN 60947-5-6 Protection from mechanical danger The sensor must not be exposed to ANY FORM of mechanical danger. Protection from UV light The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. Plug connector The plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: "WARNNG - DO NOT SEPARATE WHEN ENERGZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e. the area that is inaccessible when the connector is inserted) The plug connection can only be separated using a tool. This is achieved by using the locking protection V1-Clip (Mounting accessory from Pepperl + Fuchs). 8