ENDOCUBE An Energy-Saving Device for your Refrigerated Equipment Exclusive Distributor of EndoCube JMM Consulting Services Pte Ltd
8 Reasons that your business should be using EndoCube. Now, cutting refrigeration running costs can be this simple! Saves up to 30% electricity bill 6-24 months payback period No maintenance required. (No electrical or mechanical parts) Increase equipment lifespan Reduce maintenance and spare parts costs Can be mounted on existing equipment 5 years warranty Reduce carbon footprint
WHO IS USING ENDOCUBE? Major International Hotels U.S.A U.K Malaysia, India U.K U.K U.S.A, Thailand, India Other Activity Sectors Installed in 350 ships of the United States Navy s heavy lift fleet Installed in over 2,000 Caltex service stations nation-wide in Australia Ireland Canada U.S.A U.K Canada Ireland Denmark U.S.A Thailand U.S.A U.K Thailand Installed over 8,000 cubes in all stores in U,K
HOW DOES IT WORK? Within the Endocube, it contains a patented microcrystalline wax which mimics food. This material encases the thermostat sensor and thereby allowing food temperature to control the refrigeration system, instead of fluctuating air temperature. CERTIFICATIONS Independently tested and certified as food safe by: NSF International, Food Standards Organisation (USA). Hazard and Critical Control Point HACCP (Australia). The Food Refrigeration Research Centre (U.K).
EASY INSTALLATION 1 Simply install EndoCube over existing refrigeration controller sensor 2 Before After After installing the EndoCube, immediately reset the set point 2K warmer on the temperature controller
CASE STUDY 1 Hotel Financial Savings View BBC News Report Action 160 Endocubes are installed at the Park Plaza Riverbank Hotel, London, England. Result Total savings in 1 year was 17,000 (S$34,000) Contact: Mr. David Bell Chief Engineer Park Plaza Riverbank Hotel 18 Albert Embankment London, SE1 7TJ United Kingdom. Tel: +44 844 854 5290 Fax: +44 844 854 5291.
CASE STUDY 2 Hotel Refrigeration Energy Saving Trial Headline Results Reduction in refrigeration compressor starts in a 24 hour period. Reduction in refrigeration compressor starts by percent (%) in a 24 hour period. Energy savings Percent (%) 138 compressor starts reduced to 33 starts Reduced by 76.09% 15.616% Location: Panoramic Restaurant kitchen on the 23rd Floor. Application: Kitchen Walk-in-Cold room. Refrigeration Equipment: New Copeland Scroll air cooled condensing unit.
Where can EndoCube be used on? The Endocube can be fitted to: Walk-in-Cold room (Chiller and Freezers) Upright Commercial Chiller and Freezer Glass Door Upright Fridge & Freezer Plug-In Open Multi-deck Display Remote Open Multi-deck Display Under bar counter Deli / Salad Serve Over Counter Pharmaceutical fridges and freezer Industrial Refrigerated Warehouse Distribution Centre Chiller and Freezer delivery truck (fuel saving) Walk-in Cold Rooms Endocube can be fitted to 90% of refrigeration systems Supermarkets & Hotels Kitchens & Restaurants The Endocube cannot be fitted to: Blast Chiller & Blast Freezer Domestic fridges and freezer (no fan!) Chest freezers (no fan!)
LESS = MORE Following the product temperature, the compressor on and off cycle is now longer but frequency is lesser. This change allows lesser electricity used and, thus more energy savings for businesses. Since there are now fewer on and off cycles, refrigeration lifespan can also be extended, particularly the compressor. This leads to reduced expenditure on maintenance and replacement parts. Installing EndoCube New lower temperature