SOLAR SEPARATOR ALARM

Similar documents
Solar Separator Alarm Type Installation, Operation & Maintenance

14300 MAINS SEPARATOR ALARM MANUAL

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

Universal Tank Alarm Type Installation, Operation & Maintenance

4) Intrinsic Safety Certification

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

DB5 Intrinsically Safe Sounder Type DB-5

Intrinsically Safe Solutions

INSTRUCTION MANUAL (ATEX)

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Environmental Monitoring & Control Units Types MCU 3 & 4 Installation and Hardware

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

IECEx Certificate of Conformity

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

E2S Datasheet v10a

SET Installation and Operating Instructions. Level switch for one sensor

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

IECEx Certificate of Conformity

OSA 3. Level alarm for oil separator. Afriso Ema AB. Kilvägen 2 SE Arlöv Sweden T +46-(0) F +46-(0)

ZITON RADIO LOOP MODULE

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Fisher LCP100 Local Control Panel

OilSET-1000 (12 VDC)

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

SolarSET GSM SolarSET GSM with a Beacon

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Software Version 2.01 LEVEL MONITOR MODEL 220

1. Functions of GPS locator ETLOC-30S 3

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Mobeye CM2410 GSM fire alarm communicator

Ethernet General Purpose

Snitcher. Installation Instructions

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Earth-Rite II PLUS Static Earthing System

Certificate of Compliance

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Installationsmanual GWSL1100/2100, GWML3100

2G & 3G GSM Portable PIR Alarm

SET-2000 Hi Level/Oil

1. Introduction. 2. Product overview

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

CW9000 Wireless Fire System. Installation Manual

Fitting instructions

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Operation and Maintenance Manual

2G & 3G GSM Door Contact Alarm


BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

General Purpose IO Technical Manual

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

SET-2000 Oil/Sludge 12 VDC

INSTRUCTION MANUAL (ATEX / IECEx)

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1

ABB Instrumentation. Instruction Manual. Model 6553 Series of Intrinsically Safe Gas Analyser Systems for Hydrogen & Purge Gas Purity Measurement

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

ALTAIR 5X Multigas Detector Product Specification

2G & 3G GSM Wireless Beam Alarm

Flameproof Manual Call Points

Fire Control Panel FS5100

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

0 A EIS Intrinsically-Safe Plug-in Intelligent Photoelectronic Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS

D3D Wi-Fi GSM Smart Alarm System -User Manual

USER MANUAL Mobeye ThermoGuard CM2200

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

Silent Alert Fire Safe System

OPERATING & MAINTENANCE INSTRUCTIONS FOR EXHEAT RFA-OS TYPE FLAMEPROOF OVERSINK WATER HEATER

GSM 3G AUTO DIALLER PLUS

Snifter ATEX22 VERSION. User Manual. Distributor

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

SYSTEM 3400 ANALOGUE ADDRESSABLE FIRE DETECTION. (with Devices) Operating Manual Version 3.3X Issue 2 September 1996

Interface Modules for SENTRI

Technical Bulletin Bulletin Number: 2012_02 Released: 1 st May 2012

INSTRUCTION MANUAL (ATEX / IECEx)

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Crowcon Gasmaster. 1 to 4 channel gas detection control panel. Installation, Operation and Maintenance Manual

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

System. For a better understanding of this product, please read this user manual thoroughly before using it.

Inner Range FE3000S. Serial GSM Modem. P/No: INSTALLATION MANUAL

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Galaxy Flex V3. User Guide. Honeywell Security. This user manual is located at

INSTRUCTION MANUAL (ATEX / IECEx)

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

Transcription:

SOLAR SEPARATOR ALARM INSTALLATION AND OPERATIONS MANUAL Great British Manufacturing For emergency supply, spill cleanup, disposal, contracting, advice and training.

Subject Contents Page Important 3 General Description 3 General Operation 3 Changing Factory Settings 4 Disable Unused Probes 4 Probe Check Interval 5 Testing the Probe Sensors 4 Installation 4 Control Unit 5 Probes (High Oil & High Liquid Level Probes) 5 Silt Probe 6 Cable Distribution Box 5 Connection to Control Unit 5 Maintenance and Repair 8 Technical Information 8 Electrical 8 Apparatus Supply and I/O Parameters 8 Probe Cables 8 Mechanical 8 GSM Commands 9 SIM 0 Accessories 0

Separator Alarm Type 4007 Installation, Operation & Maintenance Name and Address of Manufacturer Darcy Spillcare Manufacture Invicta Works Mill Street, East Malling Kent, ME9 6BP Equipment Name and Type Separator Monitor Type 4007 Certificate Number Baseefa 08ATEX07X Specific Marking of Explosion [Ex ia] IIC (20 C Ta 50 C) Protection ATEX Directive Marking Ex II () G CE Mark with Notified Body Number CE 80 Serial Number and Year of Manufacture Displayed on the inside of the control unit IMPORTANT Note: In all cases good, standard electrical practice should be followed, and the installation must conform to the appropriate local code of practice e.g. BS EN 6007925 in the UK. In essence, the installation must be such that the intrinsic safety is not compromised by: exposure to risk of mechanical damage, unauthorised modification or interference, exposure to moisture, dust and foreign bodies, excessive heat, invasion of intrinsically safe circuit by other electrical equipment or circuitry. (See Note in installation section) General Description The standard system is supplied complete with an intrinsically safe control unit together with a high oil probe and a steel mounting stand. The control unit is capable of monitoring up to 6 probe units in 2 separator tanks (3 probes per tank), their current status is displayed via a 2 x 6 liquid crystal display. Two versions of this unit are available, one which signals an alarm via a flashing beacon, the other which communicates its status via GSM (mobile phone text messages). General Operation The Control Unit monitors the condition of the connected probe units by checking their condition every 30 minutes, their current status is displayed on the display located on the front of the unit. If an alarm condition is detected, a warning message is displayed followed by notification of the alarm condition detected, e.g. *HAZARD ALERT* High Oil Alarm. The unit is factory set to 30 minutes, but in extreme conditions, this can be manually changed from 5 to 60 minutes at one minute intervals. (see Changing Factory Settings)

The unit then gives the option, via the display (or text message), to accept/acknowledge the alarm. On doing so, the display instructs the user to take the appropriate action, e.g. empty the separator. After the separator has been emptied and refilled with water, the control unit rescans the probe sensors attached and presuming no alarm condition is detected, All Correct will be displayed. If the push button is pressed before the separator has been emptied, or it has been emptied but not refilled with water, then the control simply scans the probe sensor(s) and reverts to the alarm condition. It is a requirement of the certification that the cabinet door is kept closed during normal operation, only being opened for maintenance. Changing Factory Settings WARNING!!! Entering setup mode to change factory settings will set the unit back to an unactivated state and require a new activation code to be entered by contacting Darcy Spillcare Manufacture. Unused probes can be disabled and the probe check interval changed by entering setup mode. To enter setup mode, press and hold the Push Switch whilst pressing and releasing the RESET switch mounted on the board to the right of the LCD. After about 0 seconds the screen will display Setup. At this point release the Push Switch. Disable Unused Probes The factory default is for the high oil probe on zone to be enabled and all other probes disabled. If any other probes are to be used they can be enabled by entering setup mode, as described above. The following will be displayed, allowing probes to be enabled or disabled. 2 3 4 5 6 E E E E E E The block cursor will flash over the probe that can be currently toggled between enabled and disabled. To move to the next probe, press the reset switch mounted on the board to the right of the LCD. The display will blank for about 5 seconds before returning with the next selected probe. Table shows how the sensor numbers relate to the probes. Sensor Number Zone Probe Description High Oil 2 Zone High Liquid 3 Silt 4 High Oil 5 Zone 2 High Liquid 6 Silt Table Sensor to Probe Mappings To exit from setup mode, press and hold the Push Switch whilst pressing and releasing the reset switch mounted on the board to the right of the LCD.

Probe Check Interval Once setup mode is entered, as described earlier, press the TEST switch mounted on the board to the right of the LCD. The following will be displayed which allows the probe check interval to be adjusted between 5 and 60 minutes. Check Intvl: 05 To exit from setup mode, press and hold the Push Switch whilst pressing and releasing the reset switch mounted on the board to the right of the LCD. Testing the Probe Sensors The probe interrogation function can be activated at any time by simply pressing the push switch. Installation This product has been designed and certified as being intrinsically safe. It is of paramount importance, that the unit should not be modified in any way and the installation be carried out by an approved installer, in accordance with the Environment Agency guidelines (PPG3). Any deviation from this could invalidate the certification warranty and render the unit unsafe for its intended use. Upon powering up the unit for the first time, the LCD will display the following message: HAZARDOUS AREA EQUIPMENT ACTIVATION CODE REQUIRED The unit will not be able to function without the code which can be obtained by calling Darcy Spillcare Manufacture on 0732 8433. For GSM units, Darcy staff will assist in programming the unit with to 8 phone numbers which are required to receive alert messages. Control Unit Refer to Table 8 on page 8 for required cable specifications. The control unit is designed for installation outdoors and must be mounted on the stand provided to ensure it is out of the hazardous zone. For all wiring details, please refer to Table 2 on page 7. It is important that the solar panel has a clear line of sight towards the sun, faces due south and is kept clear of debris, e.g. leaves. Failure to do this will result in the battery not being charged sufficiently for continued normal operation. Care must also be taken to ensure that the solar panel is not partially or totally shadowed by nearby objects, e.g. buildings or trees, at certain times of the day as this will also reduce the charging efficiency. Probes (High Oil & High Liquid Level Probes) The high oil probe (4000) and the high liquid probe (40) (if required), need to be installed such that the float switch housing is located below or above the static

liquid level. The probe cable can be secured inside the neck of the separator using a probe mounting kit (4050). Please note the distance below or above the static liquid level will be determined by the type, style and/or size of separator. This information can be obtained from the separator manufacturer. However, as a general rule of thumb, the high liquid level probe should be placed 300mm above the static liquid level and the High Oil Probe placed 50mm below the static liquid level. Due to the varying neck lengths (turrets) that occur within each separator, each normal probe unit is fitted with 5 metres of cable. Silt Probe The silt probe is mounted in its own stainless steel stand and should be set to the required height, it can then be lowered to the base of the separator and the cable/rope can be secured to the neck of the separator using the probe mounting kit (4050). Cable Distribution Box It is advisable to connect the probe cables to a cable distribution box (4039) which should be fixed near to the top of the separator neck. The probe cable can then be terminated with a waterproof plug (provided with the distribution box). The plug is then connected to the bulkhead socket (provided with the distribution box). A cable must then be laid to connect the distribution box and the control unit. The type of connection cable required will be dependent on the environment it is used in, the route taken and maximum allowable cable capacitance and inductance (see cable parameters in Table 8 on page 8). After making the connections in the distribution box, it is advisable to spray the terminals with a conformal coating lacquer to prevent moisture ingress before finally sealing them with waterproof putty. Connection to Control Unit The Probe cable should be fed through the appropriate gland in the bottom right hand side of the control unit and connected to the terminals as instructed. The solar panel cable, and if used, any beacon or sounder cable, must be fed through the appropriate glands on the bottom left hand side of the control unit and connected to the terminals as instructed. IMPORTANT NOTE: Under NO circumstances can cables be entered into the enclosure other than on the underside as indicated, as this would infringe the certification and therefore safety of the product. ALL CABLES INSIDE THE ENCLOSURE MUST BE SECURED TO THE CRADLES WITH THE CABLE TIES PROVIDED. DO NOT EARTH ANY PART OF THE UNIT OR STAND AS IT IS A REQUIREMENT OF THE CERTIFICATION THAT 500V ISOLATION IS MAINTAINED TO EARTH.

R54 L2 TR4 LED TP R5 CN5 ISP R9 R0 R2 C4 R27 D4 C20 TEST TP2 R6 SW RESET CN6 C6 C2 C34 TP4 SW2 CN C27 C34 R36 GRP ENCLOSURE PUSH SWITCH R BATTERY SOLAR PANEL BEACON GSM TR C TR2 OPERATOR SWITCH CN2 CN3 CN4 R2 R4 C3 R3 C2 L TR3 IC C4 R6 R7 C5 FS FS2 R8 D C6 TR6 R3 TR5 R4 R C7 C8 C9 D2 D3 TR7 TP3 R5 R7 R0 R9 TR8 IC2 ZD R20 R2 R22 C5 IC3 C0 C2 R26 D5 C3 R23 R25 C7 C R24 R28 C8 LED2 C9 XT C22 R29 TR0 TR R30 TR9 R3 IC5 C23 C28 C32 C29 C33 IC6 R32 XT2 TR2 C3 R33 R34 R35 R37 R38 R39 CN8 SR SR2 CN9 FS3 C36 FS4 VR SZD C37 SR3 SR4 SR5 SR6 OIL LQD 2 SZD2 D6 SZD3 SZD4 C38 SZD5 SR7 R40 COM PWR 3 4 SZD6 IC8 C40 SR8 SR9 SLT 5 C42 Pyramid Pollution Prevention Ltd. PCB00 Issue A C4 R4 C43 XT3 COM 6 D7 R42 C44 C45 R43 R44 R45 R46 R47 CN0 IC9 CN C36 R48 C47 C48 C37 SR0 SR SR2 SR3 OIL R49 D8 R50 C50 C5 TR3 R5 SR4 LQD COM PWR 2 3 4 R52 SR5 SR6 SLT 5 LCD D9 D0 D D2 D3 C53 IC0 C54 SZD7 SZD8 COM 6 C55 C56 C57 CN2 ISP CABLE TIES MUST BE USED AT ALL TIMES CABLE BATTERY POWER IN/OUT GLANDS PROBE INPUT GLANDS Probe Terminals Type 2 3 4 5 6 High Oil Red Blue High Liquid Red Blue Silt Brown Green/Yellow Blue Table 2 Probe Connections (CN9 (zone ), CN (zone 2)) CN2 Terminal Assignment Red Black Red Black Battery Solar Panel Table 3 Battery and Solar Panel Connections (CN2) Red CN3 Terminal Assignment Beacon Table 4 Beacon Connections (CN3) Black

Maintenance and Repair Due to the harsh environments which the probes can be subjected to, it is advised that they are inspected and cleaned at regular intervals. The control unit does not contain user serviceable parts. For all repairs, contact Darcy Spillcare Manufacture on 0732 8433. Technical Information Electrical Supply Voltage Max probe cable length Beacon Output Table 5 Electrical Specifications 2V DC 200m (less if values in Table 8 would be exceeded) 2V DC 00mA max. Apparatus Supply and I/O Parameters U m 253Vrms (Note: only intended to operate from 2V DC! See Table 5) Table 6 Battery, Solar Panel, Beacon and Operator Switch Terminals (CN2 4) U o 2.6V I o 4mA P o 28mW C i 0 L i 0 Table 7 Hazardous Area Terminals (CN9, ) Group Capacitance Inductance OR L/R (µf) Ratio (mh) (µh/ω) IIC.5 2.4 92.3 IIB 7.4 85.7 369 IIA 27 7 739 Table 8 CN9, Load Parameters Probe Cables The total capacitance and inductance of the cable used between the control unit and the probe must not exceed that shown in Table 8. Mechanical Protection and/or screening of the cable should also be taken into account. The maximum length of cable between probe and control unit must not exceed 200 metres or less if the values in Table 8 on page 8 would be exceeded.

GSM Commands The following text commands (in bold) can be sent to the alarm panel, all commands can be upper or lower case, or even a mix. STATUS Performs a scan of the probes and returns the status of zone in one text message and zone 2 in a separate message, if zone 2 is enabled. An example is shown below. Battery: 00% (Normal) Status zone : High oil High water Silt buildup Alarm unaccepted Unaccepted alarms exist ACCEPT Accepts the zone alarm. Accepting the alarm above responds with a text message as shown below. Battery: 00% (Normal) Status zone : High oil High water Silt buildup alarms accepted ACCEPT 2 Accepts the zone 2 alarm. Accepting the above alarm above responds with a text message as shown below. Battery: 00% (Normal) Status zone 2: High oil High water Silt buildup alarms accepted ACCEPT Accepts the alarms on zone and zone 2, but a low battery alarm must be accepted separately as below. A low battery alarm looks like this: Battery: 5% (Low) alarm unaccepted Status zone : All correct Unaccepted alarms exist ACCEPT BATTERY Accepts the low battery alarm and sends a response as shown below. Battery: 5% (Low) alarm accepted

Status zone : All correct SIM The SIM supplied with the 4507 GSM unit is a Virgin Mobile SIM. Although text messages can be sent and received using SIMs from other service providers, remote firmware upgrades rely on certain settings in the firmware that currently only work with Virgin Mobile. Note that 3G SIMs will not work in this unit. PLEASE NOTE: The SIM card provided with this Alarm is Pay As You Go and comes with 0.00 credit. We strongly advise that the owner puts this SIM card on account with Virgin. Failure to do so will in time render the Separator Alarm inoperable. Details of how to set up an account are contained within the Virgin booklet. Accessories Part No. High Oil Probe 4000 High Level Probe 40 Silt Probe 4009 Probe Mounting Kit 4050 Signal Distribution Box 4039 For further support please contact: Darcy Spillcare Manufacture Invicta Works Mill Street East Malling Kent ME9 6BP T: 0732 8433 F: 0732 525500 E: enqs@darcy.co.uk www.darcy.co.uk