FXM4X. Product Specifications FAN COILS FXM4X

Similar documents
49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)

Dimensions H x W x D in. (mm)

FEM4X. Product Specifications FAN COILS /14/15

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL

REM4P, REM4X. Product Specifications

WAHL A Product Specifications

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg)

FCM4X. Product Specifications

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

RESIDENTIAL COOLING, HEATING, AND SMALL PACKAGE PRODUCTS CONDENSED CATALOG

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

INSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

Electric Heat Accessory Installation Instructions

Product Data. FK4C Direct Expansion Fan Coil. Sizes 001 thru 006

MODEL FK4C DIRECT EXPANSION FAN COIL. Sizes 001 thru 006. Form No. PDS FK4C.01.3

Product Data. FK4D Direct Expansion Variable Speed Fan Coil. Sizes 001 thru 006

Product Data. FV4A Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FH4A Fan Unit. Sizes 001 thru 004

Product Data. FH4A Fan Unit. Sizes 001 thru 004

FAN UNIT FH4A Sizes 001 thru 004

Product Data. FV4A Direct Expansion Fan Coil ICM2 and Puron Refrigerant. Sizes 002 thru 006

Product Data PF4MNP FAN COIL SIZES 018 THRU 060 STANDARD FEATURES AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

15 to 20 degree higher supply air temperatures 100 degree minimum supply air temperatures Up to 30 times more humidity removal

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

HIGH EFFICIENCY AIR HANDLER

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FB4B Base Series Fan Coil Sizes 024, 036, 048 and 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

Cooling Capacity CFM range

Wt. Lbs Model Number (BTUH) Hz

Bosch BVA Series Air Handler

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

HIGH EFFICIENCY AIR HANDLER

TECHNICAL SPECIFICATIONS B6VMMX

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Cooling Capacity CFM in. w.c. (125 Pa)

R4H4. Product Specifications

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Ruud Standard Efficiency Air Handler

Bosch BVA Series Air Handler

Installation Instructions

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Ruud Standard Efficiency Air Handler

Product Data. FV4C Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

WCH5**4. Product Specifications

Installation Instructions

R4H4. Product Specifications

Rheem High Efficiency Air Handler

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

PAJ3. Product Specifications

Installation Instructions

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

TECHNICAL SUPPORT MANUAL Fan Coils FVM4X B Series

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Cooling Capacity CFM in. w.c. (125 Pa)

Installation Instructions

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

Product Data FE4A, FE5A EVOLUTION SERIES COMMUNICATING VARIABLE SPEED FAN COIL PURON REFRIGERANT SIZES 002 THRU 006

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Installation Instructions

MERIT Series R-410A - Upflow / Horizontal

Rheem Standard Efficiency Air Handler

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

Ruud High Efficiency Air Handler

Electric Heat Accessory Installation Instructions

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

MERIT Series R-410A - Upflow / Horizontal

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

AIR HANDLERS AIR HANDLERS

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant

Rheem High Efficiency Air Handler

PAR5. Product Specifications

Product Data. FY4A, FA4C Base Series Fan Coil Sizes 018 Thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

TSTAT0101SC Recommended (order separately)

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

N4H4. Product Specifications

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Modular Multi-position Air Handler

TSTAT0201CW Recommended (sold separately)

CONDENSED CATALOG RESIDENTIAL PRODUCTS

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

TECHNICAL SPECIFICATIONS

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

TECHNICAL SPECIFICATIONS

CONDENSED CATALOG RESIDENTIAL PRODUCTS

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

Transcription:

ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS FXM4X Product Specifications FXM4X 1 1/2 thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed ECM motor Copper tube / aluminum fin coil on standard models Available with industry exclusive tin coated copper main tubing for additional corrosion protection Sweat connections Primary and secondary drain fittings with brass inserts 3 amp automotive type fuse in wire harness Multiple electrical entry locations Time delay relay (TDR) programmed in motor Field installed heater packages from 5 kw 30 kw available separately HUD approved for manufactured housing 208/230 1 60 supply voltage Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column 1 inch thick insulation with R value of 4.2 Multiposition installation upflow or horizontal left standard, horizontal right with minor modification (field convertible to downflow with available accessory kit) No Heat (Plug) Kit factory installed Filter (washable) factory supplied Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org. WARRANTY* 5 year No Hassle replacement limited warranty 5 year parts limited warranty With timely registration, an additional 5 year parts limited warranty * Applies to original purchaser/homeowner, some limitations may apply. See Warranty certificate for complete details. Model Number Tons FXM4X1800A FXM4X1800AT FXM4X2400A FXM4X2400AT FXM4X3000A FXM4X3000AT FXM4X3600A FXM4X3600AT FXM4X4200A FXM4X4200AT FXM4X4800A FXM4X4800AT FXM4X6000A FXM4X6000AT Nom. CFM (L/s) 1½ 600 (283) 2 800 (378) 2½ 1000 (472) 3 1200 (566) 3½ 1400 (661) 4 1600 (755) 5 2000 (944) Dimensions H x W x D in. (mm) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 53 1/16 x 24 11/16 x 22 1/16 (1357 x 627 x 576) 59 3/16 x 24 11/16 x 22 1/16 (1503 x 627 x 576) Filter Size in. (mm) 16 3/8 x 21 1/2 (416 x 546) 16 3/8 x 21 1/2 (416 x 546) 19 7/8 x 21 1/2 (505 x 546) 19 7/8 x 21 1/2 (505 x 546) 19 7/8 x 21 1/2 (505 x 546) 23 5/16 x 21 1/2 (592 x 546) 23 5/16 x 21 1/2 (592 x 546) Ship Wt lbs. (kg) 122 (55) 122 (55) 146 (66) 157 (71) 157 (71) 185 (84) 201 (91) Specifications are subject to change without notice. 496 21 5401 04 11/18/13

PRODUCT SPECIFICATIONS Fan Coils: FXM4X F = Fan Coil X = ECM M = Multiposition FAN COIL MODEL NUMBER IDENTIFICATION GUIDE F X M 4 X 1800 A T MOTOR TYPE INSTALLATION TYPE 4 = Environmentally Sound R 410A REFRIGERANT X = TXV METERING DEVICE 1800 = 18,000 BTUH = 1 1/2 tons 2400 = 24,000 BTUH = 2 tons 3000 = 30,000 BTUH = 2 1/2 tons 3600 = 36,000 BTUH = 3 tons 4200 = 42,000 BTUH = 3 1/2 tons 4800 = 48,000 BTUH = 4 tons 6000 = 60,000 BTUH = 5 tons NOMINAL CAPACITY A = Standard AT = Tin Coated Copper Tube Coils SALES CODE / FEATURES ACCESSORIES PART NUMBER IDENTIFICATION GUIDE EB AC 01 NCB A EB = Evaporator Blower AC = Accessory 01 = Product Identifier Number NCB = Non Combustible Base Kit DFK = Down Flow Kit PLG = Power Plug (no heat kit) SPK = Single Point Wiring Kit FKS = Filter Kit Small FKM = Filter Kit Medium FKL = Filter Kit Large FKX = Filter Kit Extra Large CTK = Condensate Trap Kit (PVC pipe) Sales Code ELECTRIC HEATER MODEL NUMBER IDENTIFICATION GUIDE EHK EHK = Electric Heater Kit 05 A K N 1 05 = 5 kw 07 = 7 kw 09 = 9 kw 10 = 10 kw 15 = 15 kw 18 = 18 kw 20 = 20 kw 25 = 25 kw 30 = 30 kw NOMINAL HEAT VALUE Sales Code K = 208 / 230 single phase H = 208 / 230, 3 phase KC = 208 / 230, supplied as single phase, field convertible to 3 phase HC = 208 / 230 supplied as 3 phase, field convertible to single phase VOLTAGE (60 Hz) Product Identifier Engineering Code 2 Specifications are subject to change without notice 496 21 5401 04

PRODUCT SPECIFICATIONS Fan Coils: FXM4X 496 21 5401 04 Specifications are subject to change without notice. 3 7/8, 1 3/32 1 7/8 2 DIA. 7/8 DIA. K.O. S K.O. FOR HIGH FOR VOLTAGE LOW VOLTAGE POWER 1 15/16 WIRING CONTROL 1 1 3/8 WIRING TOP VIEW 22 1/16 10 3/16 11 7/8 15/16 C B 2 1/8 1 OUTLET AIR 3/4 DISCONNECT OR NOTE: ALLOW 21 FROM FRONT CIRCUIT BREAKER UNIT CONNECTION SIZES ALTERNATE BLOWER, CONTROL, SUCTION: 18 & FOR 24 SERVICE 5/8 I.D. SWEAT NOTE: MODULAR LOCATION & ELECTRIC HEATER 30 THRU 36 3/4 I.D. SWEAT FOR LOW VOLTAGE 7/8,1 3/32,2 DIA. K. CONTROL WIRING UNITS WILL HA ACCESS PANEL 42 THRU 60 7/8 I.D. SWEAT OPTIONAL FOR FIELD HIGH VOLTAGE INLET AIR CONVERTED A TWO PIECE LIQUID: 3/8 I.D. SWEAT A COIL ACCESS RIGHT POWER SIDE RETURN WIRING CABINET OPENING 1 1/2 2 5/8 PANEL CONDENSATE: 43/4 11/16 FPT (SLOPE OPPOSITE COIL UNITS SIDEONLY) E FITTING LIQUID LINE 3 CONNECTION 1/16 LIQUID LINE SUCTION LINE CONNECTION LIQUID LINE PANEL CONNECTION CONNECTION 1 3/16 J H 19 MODULAR 10 7/16 10 3/4 SUCTION LINE 9 1/2 6 3/16 CONNECTION 1 3/4 5 1 1/4 19 OPENING 13/16 1 OPENING D FILTER ACCESS SLOPE COIL ACCESS PANEL CONFIG. FOR SLOPE DETAILS COILS 2 1/2 PANEL CONNECTION FOR UPFLOW LOCATIONS SHOWN INLET AIR LEFT APPLICATIONS DOWNFLOW OR HORIZ. AND HORIZ. INLET AIR FRONT VIEW RIGHT DOWNFLOW APPLICATIONS A COILS APPLICATIONS SD4874 4_1_A RIGHT SIDE VI Dimensions Inches (English)

PRODUCT SPECIFICATIONS Fan Coils: FXM4X 4 Specifications are subject to change without notice 496 21 5401 04 AIRFLOW 7/16 TYP. AIRFLOW 2 3/16 TYP. 1 TYP. 3 1/4 SECONDARY DRAIN F G 1 1/4 1 13/16 5/16 SECONDARY DRAIN 2 7/8 5/16 1 1/4 3 1/4 2 9/16 (21 PLACES)* TYP. (4 7/16 PLACES)* TYP. 1/2 1 1/4 1 1/4 2 7/8 2 TYP. 3/16 1 13/16 F 7/8 7/8 (FIELD HORIZ. CONVERTED LEFT WITH ACCESSARY KIT) (FIELD DOWNFLOW CONVERTED WITH ACCESSARY KIT) AIRFLOW 7/16 TYP. AIRFLOW (4 PLACES) 2 3/16 TYP. 1 TYP. SECONDARY DRAIN (2 PLACES) F4 3/4 G 3 1/8 SECONDARY DRAIN PRIMARY DRAI 1 13/16 SECONDARY DRAIN TYP* 5/16 SECONDARY DR 3 1/8 1 (2 TYP. PLACES)* 1 1/2 1/2 1 1/2 7/16 TYP, 1 3/16 5 7/8 3 1/16 5/16 7 7/8 1 3/16 1/2 7 7/8 2 TYP. 3/16 4 3/4 2 13/16 5 7/8 (4 PLACES)* 8 1 TYP. 13/16 TYP* 7/8 TYP* (FIELD DOWNFLOW CONVERTED WITH ACCESSARY HORIZ. KIT) RIG YP* HORIZ. LEFT (FIELD CONVERTED WITH ACCESSARY KIT) Dimensions Inches (English)

PRODUCT SPECIFICATIONS Fan Coils: FXM4X 496 21 5401 04 Specifications are subject to change without notice. 5 22.23, 27.78 47.6 50.80 DIA. 22.23 K.O. S DIA. K.O. FOR HIGH FOR VOLTAGE LOW VOLTAGE POWER 49.2 WIRING CONTROL 25.4 34.9WIRING TOP VIEW 560.4 258.8 279.4 22.2 23.8 C B 54.0 25.4 OUTLET AIR 19.0 DISCONNECT OR UNIT NOTE: CONNECTION ALLOW 533.4 SIZES FROM FRONT CIRCUIT BREAKER ALTERNATE BLOWER, SUCTION: CONTROL, 18 & 24 15.88 FOR I.D. SERVICE LOCATION SWEAT NOTE: MODULA & ELECTRIC HEATER FOR LOW VOLTAGE 22.23, 27.78, 50.80 DIA 30 THRU 36 19.05 I.D. CONTROL WIRING UNITS WILL HA ACCESS PANEL OPTIONAL FOR FIELD HIGH VOLTAGE 42 THRU 60 22.23 I.D. INLET SWEATAIR CONVERTED A A TWO PIECE COIL 38.1 LIQUID: ACCESS RIGHT POWER SIDE RETURN WIRING 9.53 I.D. SWEAT CABINET OPENING 66.7 PANEL CONDENSATE: 119.1 (SLOPE OPPOSITE COIL UNITS SIDE ONLY) 19.0 FPT E FITTING LIQUID LINE 77.8 CONNECTION LIQUID LINE SUCTION LINE CONNECTION LIQUID LINE PANEL CONNECTION CONNECTION 30.2 J H 482.6 MODULA 265.1 273.0 SUCTION LINE 241.3 157.2 CONNECTION 44.4 127.0 31.8 OPENING 503.2 25.4 OPENING D FILTER ACCESS SLOPE COIL ACCESS PANEL CONFIG. FOR SLOPE DETAILS COILS 63.5 RIGHT SIDE V PANEL CONNECTION FOR UPFLOW LOCATIONS SHOWN INLET AIR LEFT APPLICATIONS DOWNFLOW OR HORIZ. AND HORIZ. INLET AIR FRONT VIEW RIGHT DOWNFLOW APPLICATIONS A COILS APPLICATIONS Dimensions MM (SI Metric)

PRODUCT SPECIFICATIONS Fan Coils: FXM4X 6 Specifications are subject to change without notice 496 21 5401 04 SLOPE COIL AIRFLOW 11.1 TYP. AIRFLOW 55.6 TYP. 25.4 TYP. 82.6 SECONDARY DRAIN F G 31.8 46.0 8.0 SECONDARY DRAIN 73.0 8.0 31.8 82.6 65.1 (2 25.4 PLACES)* (4 TYP. 11.1 PLACES)* TYP. 12.7 31.8 31.8 73.0 F 22.2 22.2 (FIELD HORIZ. CONVERTED LEFT WITH ACCESSARY KIT) (FIELD DOWNFLOW CONVERTED WITH ACCESSARY KIT) AIRFLOW 11.1 TYP. AIRFLOW (4 PLACES) 55.6 TYP. 25.4 TYP. SECONDARY DRAIN (2 PLACES) F120.6 G 79.4 SECONDARY DRAIN SECONDARY 46.0 DRAIN 8.0 TYP* PRIMARY DRAI SECONDARY DR 79.4 25.4 TYP. 38.1 38.1 12.7 200.0 30.2 30.2149.2 77.8 8.0 71.4 149.2 120.6 12.7 2.2TYP* 200.0 TYP* (FIELD DOWNFLOW CONVERTED 46.0 WITH ACCESSARY KIT) YP* (FIELD HORIZ. CONVERTED LEFT WITH ACCESSARY KIT) TYP. A COIL (FIELD HORIZ. CONV RIG Dimensions MM (SI Metric)

PRODUCT SPECIFICATIONS Fan Coils: FXM4X DIMENSIONAL DATA (refer to drawings on previous pages) Dimensions Inches Ship. Size Coil Weight Model (tons) A B C D E F G H J Suct Liquid Type (lbs) FXM4X1800A(T) 1-1/2 49-5/8 17-5/8 15-3/4 15-5/8 15-3/8 23-1/8 23-5/8-17 5/8 3/8 Slope 122 FXM4X2400A(T) 2 49-5/8 17-5/8 15-3/4 15-5/8 15-3/8 23-1/8 23-5/8-17 5/8 3/8 Slope 122 FXM4X3000A(T) 2-1/2 53-7/16 21-1/8 19-1/8 19-1/8 19-3/16 26-15/16 27-1/2-19 3/4 3/8 Slope 146 FXM4X3600A(T) 3 49-5/8 21-1/8 19-1/8 19-1/8 15-11/16 23-7/16 23-1/8 - - 3/4 3/8 A 157 FXM4X4200A(T) 3-1/2 49-5/8 21-1/8 19-1/8 19-1/8 15-11/16 23-7/16 23-1/8 - - 7/8 3/8 A 157 FXM4X4800A(T) 4 53-1/16 24-11/16 22-3/4 22-11/16 19-1/2 27-1/4 26-15/16 28-5/16-7/8 3/8 A 185 FXM4X6000A(T) 5 59-3/16 24-11/16 22-3/4 22-11/16 25-1/4 32-15/16 32-5/8 34-1/16 -- 7/8 3/8 A 201 DIMENSIONAL DATA (refer to drawings on previous pages) Dimensions MM Ship. Size Coil Weight Model (tons) A B C D E F G H J Suct. Liquid Type (kg) FXM4X1800A(T) 1-1/2 1261 448 400 397 391 587 600-432 16 10 Slope 55 FXM4X2400A(T) 2 1261 448 400 397 391 587 600-432 16 10 Slope 55 FXM4X3000A(T) 2-1/2 1357 537 489 486 487 684 699-483 19 10 Slope 66 FXM4X3600A(T) 3 1261 537 489 486 399 595 587-19 10 A 71 FXM4X4200A(T) 3-1/2 1261 537 489 486 399 595 587-22 10 A 71 FXM4X4800A(T) 4 1357 627 578 576 495 692 684 719 22 10 A 84 FXM4X6000A(T) 5 1503 627 578 576 641 837 829 865 22 10 A 91 PHYSICAL DATA Model Size 1800 2400 3000 3600 4200 4800 6000 Blower Data CFM nominal (L/s) 600 (283) 800 (378) 1000 (472) 1200 (566) 1400 (661) 1600 (755) 2000 (944) Motor Type ECM HP 1/3 1/3 1/2 1/2 1/2 3/4 3/4 Filter Data (factory supplied, washable) Filter Size in. (mm) 16 3/8 x 21 1/2 (416 x 546) 19 7/8 x 21 1/2 (505 x 546) 23 5/16 x 21 1/2 (592 x 546) Coil Data (all coils 14½ fins per inch, wavy lanced bare aluminum fin) Face Area ft 2 (m 2 ) 2.97 (0.28) 2.97 (0.28) 3.46 (0.32) 4.45 (0.41) 5.93 (0.55) 7.42 (0.69) Refrigerant Line Connections (sweat) Liquid inch (mm) 3/8 (10) 3/8 (10) 3/8 (10) 3/8 (10) 3/8 (10) 3/8 (10) 3/8 (10) Suction inch (mm) 5/8 (16) 5/8 (16) 3/4 (19) 3/4 (19) 7/8 (22) 7/8 (22) 7/8 (22) 496 21 5401 04 Specifications are subject to change without notice. 7

PRODUCT SPECIFICATIONS Fan Coils: FXM4X ELECTRICAL DATA, FAN COIL ONLY WITHOUT ELECTRIC HEAT 208/230V, single phase, 60 Hz Model Motor Full Load Amps (FLA) Minimum Circuit Ampacity (MCA) Maximum Fuse/Ckt Bkr Amps (Max OverCurrent Protection MOCP) FXM4X1800 2.8 3.5 15 FXM4X2400 2.8 3.5 15 FXM4X3000 4.1 5.1 15 FXM4X3600 4.1 5.1 15 FXM4X4200 4.1 5.1 15 FXM4X4800 6.0 7.5 15 FXM4X6000 6.0 7.5 15 AIRFLOW PERFORMANCE CFM at a given Speed and Static reading Model Blower Speed Measured Static Pressure, inlet to outlet (inches water column) 0.10 0.20 0.30 0.40 0.50 0.60 Tap 5 776 745 696 660 609 572 Tap 4 683 644 589 548 494 461 FXM4X1800 Tap 3 683 644 589 548 494 461 Tap 2 631 563 500 443 409 361 Tap 1 625 524 457 417 367 319 Tap 5 956 920 891 851 816 780 Tap 4 825 795 757 722 674 634 FXM4X2400 Tap 3 825 795 757 722 674 634 Tap 2 726 695 635 598 543 509 Tap 1 631 563 500 443 409 361 Tap 5 1189 1151 1104 1050 1003 959 Tap 4 1041 998 944 886 837 772 FXM4X3000 Tap 3 1041 998 944 886 837 772 Tap 2 924 876 817 752 704 660 Tap 1 779 693 628 571 526 476 Tap 5 1363 1332 1294 1253 1207 1157 Tap 4 1237 1206 1160 1121 1070 1013 FXM4X3600 Tap 3 1237 1206 1160 1121 1070 1013 Tap 2 1095 1058 1007 951 888 824 Tap 1 1014 885 773 673 609 549 Tap 5 1519 1490 1454 1419 1379 1332 Tap 4 1437 1403 1366 1333 1294 1245 FXM4X4200 Tap 3 1437 1403 1366 1333 1294 1245 Tap 2 1257 1226 1191 1141 1090 1033 Tap 1 1237 1206 1160 1121 1070 1013 Tap 5 1757 1725 1693 1653 1614 1576 Tap 4 1664 1626 1593 1552 1517 1477 FXM4X4800 Tap 3 1664 1626 1593 1552 1517 1477 Tap 2 1459 1420 1379 1336 1298 1259 Tap 1 1301 1241 1195 1150 1102 1039 Tap 5 2030 1995 1961 1927 1888 1842 Tap 4 1811 1775 1740 1703 1664 1613 FXM4X6000 Tap 3 1811 1775 1740 1703 1664 1613 Tap 2 1665 1632 1593 1556 1507 1453 Tap 1 1462 1418 1371 1327 1278 1228 NOTES: 1. Airflow based upon dry coil at 230v with factory approved filter and electric heater (2 element heater sizes 18 through 36, 3 element heater sizes 42 through 60). 2. Airflow at 208 volts is approximately the same as 230 volts because the X13 motor is a constant torque motor. The torque doesn t drop off at the speeds the motor operates. 3. To avoid potential for condensate blowing out of drain pan prior to making drain trap: Return static pressure must be less than 0.40 in. wc. Horizontal applications of 042 060 sizes must have supply static greater than 0.20 in. wc. 4. Airflow above 400 cfm/ton on 048 060 size could result in condensate blowing off coil or splashing out of drain pan. 5. Shading Airflow outside 450 cfm/ton. 8 Specifications are subject to change without notice 496 21 5401 04

PRODUCT SPECIFICATIONS Fan Coils: FXM4X STATIC PRESSURE DROP ACROSS FILTER (inches of water column) Model Size CFM 400 600 800 1000 1200 1400 1600 1800 2000 1800.020.044.075 2400.022.048.072.100 3000.022.048.072.100 3600.051.070.092.120.152 4200.051.070.092.120.152 4800.051.070.092.120.152 6000.086.105.130 STATIC PRESSURE CORRECTION FROM DRY TO WET COIL (inches of water column) Airflow performance chart was developed using fan coils with DRY coils. When taking a static reading across a WET coil, adjust the static pressure numbers by adding the values in this table (for a given CFM, wet coil will have greater static pressure drop than dry coil). Model Size CFM 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 1800.034.049.063 2400.016.027.038.049.059 3000.049.059.070.080 3600.055.064.073.081 4200.049.056.063.070 4800.038.043.049.054.059 6000.027.031.035.039.043 STATIC PRESSURE CORRECTION FOR ELECTRIC HEATERS (inches of water column) Airflow performance chart was developed using fan coils with 10 kw electric heater (2 elements) in the 1800 3600 model sizes, and 15 kw electric heaters (3 elements) in the 4200 6000 model sizes. When using a different number of heater elements, adjust the static pressure numbers by adding or subtracting the values in this table (for a given CFM, more electric heater elements create higher static pressure drop). Heater kw Model Size No Heater 3 or 5 8 or 10 9 or 15 20 Number of Heat Elements 0 1 2 3 4 1800 +0.02 +0.01 0 0.02 0.04 2400 +0.02 +0.01 0 0.02 0.04 3000 +0.02 +0.01 0 0.02 0.04 3600 +0.02 +0.01 0 0.02 0.04 4200 +0.04 +0.02 0 0.02 4800 +0.04 +0.02 0 0.02 6000 +0.04 +0.02 0 0.02 ESTIMATED SOUND POWER LEVEL (dba) Model Conditions Octave Band Center Frequency* Size CFM Ext Static Pressure 63 125 250 500 1000 2000 4000 1800 600 0.25 64.7 60.7 56.7 53.7 51.7 49.7 45.7 2400 800 0.25 66.0 62.0 58.0 55.0 53.0 51.0 47.0 3000 1000 0.25 67.0 63.0 59.0 56.0 54.0 52.0 48.0 3600 1200 0.25 67.8 63.8 59.8 56.8 54.8 52.8 48.8 4200 1400 0.25 68.4 64.4 60.4 57.4 55.4 53.4 49.4 4800 1600 0.25 69.0 65.0 61.0 58.0 56.0 54.0 50.0 6000 2000 0.25 70.0 66.0 62.0 59.0 57.0 55.0 51.0 * Estimated sound power levels have been derived using the method described in the 1987 ASHRAE HVAC Systems & Applications Handbook, Ch 52, pg 52.7. 496 21 5401 04 Specifications are subject to change without notice. 9

PRODUCT SPECIFICATIONS Fan Coils: FXM4X 10 Specifications are subject to change without notice 496 21 5401 04 ELECTRIC HEATER ELECTRICAL DATA BRANCH CIRCUIT Max Wire Length 208/230V (Ft) Dual Circuit Single Dual Circuit Circuit HEATER AMPS Heater kw INTERNAL 208/230V Min Ampacity Min Wire Size (AWG) Min Gnd Wire Size Max Fuse/Ckt Bkr Amps Heater Model PHASE CIRCUIT 208/230V 208/230V 1 208/230V 208/230V PROTECTION Single Dual Circuit Single Dual Circuit Single Dual Circuit Single Dual Circuit Single 230v 208v Circuit L1,l2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1, L2 L3, L4 Circuit L1, L2 L3,L4 Circuit L1,L2 L3,L4 L1,L2 L3,L4 EHK05AKN* 5 3.8 1 None 18.1/20.0 26.0/28.4 10/10 10/10 30/30 66/66 EHK05AKN** 5 3.8 1 None 18.1/20.0 31.2/33.5 8/8 10/10 35/35 85/88 EHK05AKB* 5 3.8 1 Ckt Bkr 18.1/20.0 26.0/28.4 10/10 10/10 30/30 66/66 EHK05AKB** 5 3.8 1 Ckt Bkr 18.1/20.0 31.2/33.5 8/8 10/10 35/35 85/88 EHK07AKN 8 6.0 1 None 28.9/32.0 44.7/48.5 8/8 10/10 45/50 59/60 EHK07AKB 8 6.0 1 Ckt Bkr 28.9/32.0 44.7/48.5 8/8 10/10 45/50 59/60 EHK09AKCN 9 6.8 1 None 32.8/36.0 49.5/53.5 8/6 10/10 50/60 54/87 9 6.8 3 None 18.8/20.8 32.0/34.5 8/8 10/10 35/35 83/85 EHK10AKN 10 7.5 1 None 36.2/40.0 53.8/58.5 6/6 10/10 60/60 78/80 EHK10AKB 10 7.5 1 Ckt Bkr 36.2/40.0 53.8/58.5 6/6 10/10 60/60 78/80 EHK15AKF 15 11.3 1 Fuse 54.2/59.9 36.2/40.0 18.1/20.0 76.3/83.4 53.8/58.5 22.7/25.0 4/4 6/6 10/10 8/8 10/10 10/10 80/90 60/60 25/25 88/89 78/80 75/76 EHK15AKB 15 11.3 1 Ckt Bkr 36.2/40.0 18.1/20.0 53.8/58.5 22.7/25.0 6/6 10/10 10/10 10/10 60/60 25/25 78/80 75/76 EHK15AHN 15 11.3 3 None 31.3/34.6 47.7/51.8 8/6 10/10 50/60 56/90 EHK18AHN 18 13.5 3 None 37.6/41.5 55.5/60.4 6/6 10/8 60/70 76/77 EHK20AKF 20 15.0 1 Fuse 72.3/79.9 36.2/40.0 36.2/40.0 98.9/108.4 53.8/58.5 45.3/50.0 3/2 6/6 8/8 8/6 10/10 10/10 100/110 60/60 50/50 85/109 78/80 59/59 EHK20AKB 20 15.0 1 Ckt Bkr 36.2/40.0 36.2/40.0 53.8/58.5 45.3/50.0 6/6 8/8 10/10 10/10 60/60 50/50 78/80 59/59 EHK25AHCF EHK30AHCF Heater Model 24 18.0 3 Fuse 50.1/55.4 71.2/77.8 4/4 8/8 80/80 94/95 24 18.0 1 Fuse 86.7/95.5 116.9/127.9 1/1 6/6 125/150 115/116 30 22.5 3 Fuse 62.6/69.2 86.8/95.0 3/3 8/8 90/100 97/98 30 22.5 1 Fuse 109.0/120.0 144.8/158.5 0/00 6/6 150/175 117/150 Heater kw 230V 208V P H A S E Heater Amps 208/230V FIELD MULTIPOINT WIRING OR 24 AND 30 KW SINGLE PHASE Minimum Circuit Ampacity 208/230V Minimum Wire Size (AWG) 208/230V Min Gnd Wire Size 208/230V Max Fuse/Ckt Bkr Amps 208/230V Max Wire Length 208/230V (FT) L1, L2 L3, L4 L5, L6 L1, L2 L3, L4 L5, L6 L1, L2 L3, L4 L5, L6 L1, L2 L3, L4 L5, L6 L1, L2 L3, L4 L5, L6 EHK25AHCF 24 18.0 1 28.9/32.0 28.9/32.0 28.9/32.0 44.7/48.5 36.2/40.0 36.2/40.0 8/8 8/8 8/8 10/10 45/50 40/40 40/40 59/60 73/73 73/73 EHK30AHCF 30 22.5 1 36.2/40.0 36.2/40.0 36.2/40.0 53.8/58.5 45.3/50.0 45.3/50.0 6/6 8/8 8/8 10/10 60/60 50/50 50/50 78/80 59/59 59/59 Notes: 1 Copper wire must be used. If other than uncoated (non-plated), 75 C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the National Electric Code (ANSI/NFPA 70). * When used with Fan Coil model sizes 2400, 3600. ** When used with Fan Coil model sizes 4200, 4800, 6000. Includes blower motor amps of largest Fan Coil used with heater. Supplied as single phase, field convertible to 3-phase. Supplied as 3-phase, field convertible to single phase, single or multiple supply circuits. Length shown is as measured one way along wire path between unit and service panel for a voltage drop not to exceed 2%.

PRODUCT SPECIFICATIONS Fan Coils: FXM4X ACCESSORIES Part Number Description Use with model size EBAC01DSC Disconnect Kit use with All Heaters 5 kw thru 10 kw EBAC01NCB EBAC02NCB 2400, 3000 Downflow Base Kit EBAC03NCB 3600, 4200, 4800 1800 EBAC04NCB 6000 EBAC01DFS Bracket, Downflow Conversion Kit Slope Coil 1800, 2400, 3000 EBAC02DFA Bracket, Downflow Conversion Kit A Coil 3600, 4200, 4800, 6000 EBAC01SPK AMFK20SPA or Square D part # QOU14100JBAF EBAC01FKM Single Point Wiring Kit Single Point Wiring Kit Square D Jumper Bar Assembly Only for use with 15 kw & 20 kw fused heaters Only for use with EHK15AKB and EHK20AKB breaker heaters 1800, 2400 Filter Kit (washable, box of 12) EBAC01FKL 3000, 3600, 4200 Factory Supplied EBAC01FKX 4800, 6000 NASA00201FR Standard Filter Rack (16 x 20 x 1 filter required) 1800, 2400 NASA00301FR Standard Filter Rack (20 x 20 x 1 filter required) 3000, 3600, 4200 Factory Supplied NASA00401FR Standard Filter Rack [quantity 2] (12 x 20 x 1 filter required) 4800, 6000 EBAC01PLG No Heat (Plug) Kit (box of 6) Factory Installed EBAC01CTK PVC Condensate Trap Kit (box of 50) ALL EBAC01GSK Horizontal/Downflow Gasket Kit ALL (required for horizontal right and downflow) ELECTRIC HEATERS Part Number Description Use with Model Sizes EHK05AKN 5 kw, single phase, no internal circuit protection ALL EHK05AKB 5 kw, single phase, with circuit breakers ALL EHK07AKN 8 kw, single phase, no internal circuit protection ALL EHK07AKB 8 kw, single phase, with circuit breakers ALL EHK09AKCN 9 kw, supplied as single phase, field convertible to 3 phase, no internal circuit protection 3600, 4200, 4800, 6000 EHK10AKN 10 kw, single phase, no internal circuit protection ALL EHK10AKB 10 kw, single phase, with circuit breakers ALL EHK15AKF 15 kw, single phase, with fuses 2400, 3000, 3600, 4200, 4800, 6000 EHK15AKB 15 kw, single phase, with circuit breakers 2400, 3000, 3600, 4200, 4800, 6000 EHK15AHN 15 kw, 3 phase, no internal circuit protection 3600, 4200, 4800, 6000 EHK18AHN 18 kw, 3 phase, no internal circuit protection 4200, 4800, 6000 EHK20AKF 20 kw, single phase, with fuses 3000, 3600, 4200, 4800, 6000 EHK20AKB 20 kw, single phase, with circuit breakers 3000, 3600, 4200, 4800, 6000 EHK25AHCF EHK30AHCF 24 kw, supplied as 3 phase, field convertible to single phase, with fuses 30 kw, supplied as 3 phase, field convertible to single phase, with fuses 4800, 6000 4800, 6000 Copyright 2013 International Comfort Products Lewisburg, Tennessee 37091 USA www.gotempstar.com 496 21 5401 04 Specifications are subject to change without notice. 11