WATER INGRESS ALARM SYSTEM ON BULK CARRIERS ELECTRODE TYPE DETECTOR SUPER EYE

Similar documents
***** 2. Rev.1 is to be uniformly implemented by IACS Members from 1 July 2004.

RESOLUTION MSC.145(77) (adopted on 5 June 2003) PERFORMANCE STANDARDS FOR WATER LEVEL DETECTORS ON BULK CARRIERS

RESOLUTION MSC.188(79) (adopted on 3 December 2004) PERFORMANCE STANDARDS FOR WATER LEVEL DETECTORS ON BULK CARRIERS AND SINGLE HOLD CARGO SHIPS

Technical Manual. Level Alarm Unit CARLA & WIDS

E-20 COMPARTMENT FLOODING WATER LEVEL DETECTORS (INCLUDING SENSORS)

Main changes in BV Rules for Steel Ships

FS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH

Survey of electrical equipment installed in hazardous areas on tankers

IMO FP 53 Report. Lloyd s Register report on the 53 rd session of IMO Fire Protection Sub-Committee. 16 th March, 2009

Void. Technical Information. Subject. Bulk Carrier Safety:Water Ingress Detection and Alarm System. No. TEC-0537 Date 3 July 2003

ClassNK Technical Information No. TEC-0453 Attachment (1) to ClassNK Technical Information No. TEC-0453 Guidance on SOLAS Chapter II-2 as amended in 2

General Specifications

Navigation Lights Signalling Lights Searchlights Whistles TECHNICAL DOCUMENT. DHR 230RCN 230 Remote Controlled Searchlight. Den Haan Rotterdam

DRY CHEMICAL POWDER SYSTEM REQUIREMENTS TO COMPLY WITH THE LATEST IMO IGC CODE AND EUROPEAN COUNCIL CLARIFICATIONS

Fan Heaters Type VLEx

COMPANY INTRODUCTION

SCC 101 G Valid as of G11SE0404 up to G11SE... SCC 101 G

Honeywellmarine.com. Honeywell Proprietary

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Notice on the implementation of the amendments to the FSS Code in resolution MSC.339(91)

Notice No. 7. Rules and Regulations for the Classification of Ships, July Issue date: March Working together for a safer world

Flammable liquids, gasoline, oil etc. Advantages. 21 B. Ø 920 mm 21 B. Ø 920 mm

Display Cases Deli Cases Service Manual

C e r t i f i c a t e

KUBOTA Double suction volute pump

IACS RESOLUTION CHANGES (GMO ) BEKİR SITKI TÜRKMEN

Main changes in BV Rules for Steel Ships

Temperature Measurement Transmitters for field mounting

Waterproof TCW060 just light

Technical Data Sheet BNWAS. Bridge Navigational Watch Alarm System. Technical Data Sheet. General Features

SCC 61 E Valid as of E61SE0404 up to E61SE... SCC 61 E

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

DASPOS A/S Gammel Klausdalsbrovej Herlev Denmark Tel.: website: DASPOS USA, Inc NE 116th Street, PMB

COMPANY PROFILE. Design, Development & Installation of Electrical & Automatic Control Systems

CB IP40. Specification. Cold rolled steel sheet. Enclosure s body and mounting plate: 1 mm. Door panel: 1.5 mm.

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

IACS Unified Interpretations and Panel Responsible

15-BER3. parts list as Excel-spreadsheet. Tsurumi Europe GmbH

Technology. Drum H eaters ZIEGLER ENGINEERING. Metal drum heater design

Manual. Simrad Panorama Mk2 Rudder Angle Indicator. English. A brand by Navico - Leader in Marine Electronics.

PLATE HEAT EXCHANGERS FOR MARINE APPLICATIONS

Guideline No.: C-02(201510) C-02 FIRE DOORS. Issued date: October 20,2015. China Classification Society

Rosemount TankRadar STaR

Marine Solutions. Honeywell s Solution for LNG Vessels

RESOLUTION MSC.217(82) (adopted on 8 December 2006) AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

Analog Transmitter AT1000 AT1

Part 6 Additional class notations Chapter 6 Additional fire protection for passenger vessels

MSC Guidelines for Foam Fire Suppression Systems

Additional Fire Protection (F-AMC)

Personal ph, ph/orp, Conductivity Meters

Electromagnetic Flowmeter

PATROL BOATS HIGH SPEED, LIGHT CRAFT AND NAVAL SURFACE CRAFT RULES FOR CLASSIFICATION OF DET NORSKE VERITAS SPECIAL SERVICE AND TYPE ADDITIONAL CLASS

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Requirements for ships carrying hydrogen and compressed natural gas vehicles

on board with solutions

Conductive Leakage detectors of the Leckstar range

DNVGL-CP-0398 Edition December 2015

INSTRUCTION MANUAL with Replacement Parts

Personal ph, ph/orp, Conductivity Meters

Product Catalog June 2012

C-01 FIRE DECKS AND BULKHEADS

RECORD OF GARBAGE DISCHARGES PART II. For all cargo residues as defined in regulation 1.2 (Definitions) (Ships that carry solid bulk cargoes)

Personal ph, ph/orp, Conductivity Meters PH71/PH72/SC72

ROP-63 & ROP-63H MANUAL CALL POINTS

Complete tank expertise. Marine tank management solutions for all ship types

Bevent Rasch BSKC6. - Fire /06/17

2013Mexico USA Safety Seminar. Rapp Bomek AS Fire and Explosion Proof Doors

BR

FirePro ANNEX 1 MARINE MANUAL. Version 1,

LEAKSTOPPER RANGE Multizone water leak detection systems

IMO CCC1 Summary Report on the developments of the IGF Code

Guidance on the construction of CO 2 systems

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for MIWE

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

CONTROL NARRATIVE. Ammonia Tank Farm Aqueous Ammonia Truck Unloading, Storage Tanks, Forwarding, Vaporizer & Dilution Air Package

SOLAREKS - ELECTRIC WATER HEATER

Instruction Manual April sitrans AS 100

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

FAN SEPARATOR. Fan / Separator H2SO4 (Sulfuric Acid) is Designed to Remove Fume and Other Contaminants from the Air Stream.

AUDIBLE SIGNALIZATION

IN-SITU ZIRCONIA OXYGEN ANALYZER <HART communication>

Control unit PPT/RS,, Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and contr

DOO IK ENG PRODUCT CATALOG DOO IK ENG TEMPERATURE SENSOR PRESSURE SWITCH NON FLOW SWITCH THERMOMETER

FIRE SAFETY SHIPS RULES FOR CLASSIFICATION OF NEWBUILDINGS DET NORSKE VERITAS MACHINERY AND SYSTEMS MAIN CLASS PART 4 CHAPTER 10 JULY 2006

ADDITIONAL FIRE PROTECTION (F-AMC)

RESOLUTION MSC.291(87) (adopted on 21 May 2010) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CONVENTION FOR THE SAFETY OF LIFE AT SEA, 1974, AS

ACCESSORIES ITEM NUMBER. Digital timer, burning and ventilating. RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. fault detector.

Bevent Rasch RABC-VAV. - Fire /03/2018

SIMPLIFIED VOYAGE DATA RECORDER (S-VDR)

REPUBLIC OF LIBERIA BUREAU OF MARITIME AFFAIRS

Specifications. Table of contents. 2:Specification. 3:Composition. 4:Instruments outside figure

Advanced tank technology

POINT ROLLOVER LIGHTS PRL LED HELIDECK SEMIFLUSH LIGHT

MOBILE OFFSHORE DRILLING UNITS 2012

Screw plug immersion heaters

Installation Instructions

THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY

Fire. IMO fire control signs - according to IMO Resolution A.654 (16) (mm) 150x x200

Transcription:

SHEET NO. 50-41000-6A WATER INGRESS ALARM SYSTEM ON BULK CARRIERS TYPE DETECTOR SUPER EYE SUPER EYE water ingress alarm system is certified by every classification society for the ships (ABS, BV, DNV, LR, NK) in accordance with IACS SC180 (Sep.2003/Rev.1 May 2004) Hold. Ballast and dry space water level detectors (SOLAS chapter XII, Regulation 12 (IMO Resolution MSC. 134(76)) and Performance Standards for Water Level Detectors on Bulk Carriers (IMO Resolution MSC. 145(77)) 1 KC IDEAL TECHNOLOGY

WHEELHOUSE BOSUN STORE MAIN JUNCTION BOX BOX WHEELHOUSE ENGINE ROOM TYPE N0.9 CARGO HOLD TYPE N0.8 CARGO HOLD TYPE N0.2 CARGO HOLD TYPE N0.1 CARGO HOLD F. P. T. ALARM PANEL (IP23) (IN WHEELHOUSE) L-MPYC-37 L-MPYC-37 CONTROL PANEL (IP23) (IN AIR CONDITION ROOM) H-DPYC-1.5 H-DPYC-1.5 L-MPYC-19 MAIN ELECTRIC SOURCE AC100V 1Ø 60Hz EMERGENCY ELECTRIC SOURCE DC24V VDR OUTPUT L-MPYC-27 L-MPYC-27 MAIN JUNCTION BOX (IP23) PROVIDED BY SHIP YARD BOX2 (IP68) BOX1 (IP68) COMPANION ROOM (IP56) JUNCTION BOX (JB-1) ENGINE ROOM (IP56) BOX9 (IP68) BOX8 (IP68) BOX7 (IP68) BOX6 (IP68) BOX5 (IP68) BOX4 (IP68) BOX3 IN CARGO HOLD MAIN ALARM LEVEL PRE-ALARM LEVEL NO.9 CARGO HOLD NO.8 CARGO HOLD NO.7 CARGO HOLD NO.6 CARGO HOLD NO.5 CARGO HOLD NO.4 CARGO HOLD NO.3 CARGO HOLD MAIN MAIN PRE PRE NO.2 CARGO HOLD NO.1 CARGO HOLD * : MAKER SUPPLY WIRE BOSUN STORE F. T. P. 2

WHEELHOUSE CONTROL PANEL BOX BOX IN CRANE POST BOX IN CRANE POST BOX IN CRANE POST BOX IN CRANE POST BOSUN STORE ENGINE ROOM ENGINE ROOM TYPE N0.5 CARGO HOLD TYPE N0.4 CARGO HOLD TYPE N0.3 CARGO HOLD TYPE N0.2 CARGO HOLD TYPE N0.1 CARGO HOLD F. P. T. (IP23) ALARM PANEL (IN WHEEL HOUSE) L-MPYC-27 L-MPYC-27 CONTROL PANEL (IP23) L-DPYC-2.5 L-MPYC-2.5 MAIN ELECTRIC SOURCE AC100V 1Ø 60Hz EMERGENCY ELECTRIC SOURCE DC24V ACTUATOR OF EDUCATOR VALVE (IP56) IN ENGINE ROOM BOX5 KD-1019 IN CRANE POST (IP56) BOX4 KD-1019 IN CRANE POST (IP56) BOX3 KD-1019 IN CRANE POST (IP56) BOX2 KD-1019 IN CRANE POST (IP56) BOX1 KD-1019 (IP68) BOSUN STORE JUNCTION BOX JB300KZ HYDLAULICK CONTROL STAND BOSUN STORE IN HOLD MAIN ALARM LEVEL PRE-ALARM LEVEL F. P. T. NO.5 HOLD NO.4 HOLD NO.3 HOLD NO.2 HOLD NO.1 HOLD 3

Electric current + _ 4

+ _ + 5

CABLE CABBLE GLAND IP68 AIR PRESSURE INSTALLATION PLATE TEST PORT PROVIDE BY SHIPYARD 1/4 ø40 182 (30) TERMINAL EPOXY RESIN ø64 90 ø115 SUS316 100 86 40 CABLE GLAND IP68 FLANGE WITH CABLE GLAND JIS 5K 32A FLANGE PROVIDED BY SHIPYARD 32A STPG370 SCH80 (GALVANIZE) PIPE SUPPORT CABLE GLAND IP68 JIS 5K 32A FLANGE TERMINAL Ti with Pt PLATING MAIN ALARM LEVEL 10% VOLUM OF F. P. T. SUS316 AIR PRESSURE TEST PORT & DRAIN PLUG WITH SEAL TAPE OR LIQUID SEALANT (30) 182 BASE LINE H SEPARATOR PVC 6

CARGO HOLD SIDE FLANGE PACKING 8-M16 BOLTS WELD BY SHIPYARD AIR PRESURE TEST PORT 1/4 CABLE GRAND IP68 ø165 ø120 MAIN ALARM LEVEL (30) 182 2 20 S WELD BY SHIPYARD CABLE GRAND IP68 PRE-ALARM LEVEL BODY SCS13 DOUBLEING PLATE (SM490) ENGINE ROOM CARGO HOLD SIDE FLANGE PACKING PFTE 8-M16 BOLTS WELD BY SHIPYARD AIR PRESSURE TEST PORT 1/4 CABLE GLAND IP68 MAIN ALARM LEVEL TERMINAL DOUBLING PLATE (SM490) S (30) 182 2 20 WELD BY SHIPYARD ø200 ø165 ø 52 ø 92 ø 120 ø 250 PRE-ALARM LEVEL DOUBLING PLATE (SM490) BOTTOM LINE 7

4-ø15 HOLES 182 100 16 9 0 82 CABLE GLAND TERMINAL EPOXY RESIN AIR PRESUSURE TEST PORT 1/4 COVER SCS13 PLATINUM PLATING TITANUM 40 46 ø115 ø90 ø16 ø64 90 SUS316 BODY SCS13 TERMINAL ARRANGEMENT T2 T1 S2 S1 (PLATINUM PLATING TITANUM) (SUS316) 8

182 100 82 18 4-ø15 HOLES 16 90 FLANGE SUS13 ø115 ø90 ø16 ø64 90 CABLE GLAND TERMINAL EXPOXY RESIN AIR PRESSURE TEST PORT 1/4 DOUBLING PLATE SM490 or EQUIVALENT 20 8-ø19 HOLES COVER SCS13 Ti with Pt PLATING 40 ø200 ø165 20 ø52 ø250 46 BODY SCS13 SUS316 TERMINAL ARRANGEMENT T2 T1 S2 S1 (Ti with Pt PLATING) (SUS316) 9

280 250 220 4 3 180 220 6 2 20a 20c 20c 4-ø9 SETTING HOLES 4 7 1 5 50 ABT. 150 1 BODY 2 COVER 3 GASKET 4 CRAMPING SCREW 5 CABLE GLAND 6 NAME PLATE 7 HINGE 3.2 TERMINAL CABLE GLAND SKINDICHT 5311 2030 300 250 80 150 180 8-M8X45 (SUS) 300 199 4-ø10 AIR PRESSURE TEST PORT 1/4 10

8 20c 25a 80 220 250 280 20c 3.2 50 180 4-ø9 SETTING HOLES ABT. 150 200 1 BODY 2 COVER 3 GASKET 4 CRAMPING SCREW 5 CABLE GLAND 6 NAME PLATE 7 HINGE 8 ZENER 4 2 6 3 4 7 1 5 5 80 7 8 2 1 5 300 250 280 3 300 AIR PRESSURE TEST PORT 1/4 4 5 150 (200) 47 PREPARED BY SIPYARD MOUNT 1 BODY 2 COVER 3 GASKET 4 CRAMPING SCREW 5 CABLE GLAND 6 NAME PLATE 7 ZENNER 180 210 4-ø10 11

ELEC SOURCE 700 740 40 70 60 320 600 4-ø15 HOLES 200 ELEC SOURCE 600 640 40 70 60 320 600 4-ø15 HOLES 200 12

65 350 380 CAUTION PLATE FOR FRESH / SEA SWITCH 350 4-ø10 400 160 65 350 380 CAUTION PLATE FOR FRESH / SEA SWITCH 350 4-ø10 400 160 13

400 4-ø6.8 350 380 410 430 460 160 CAUTION PLATE FOR FRESH / SEA SWITCH COAMING 40X80 360 380 410 430 4-M6 14

400 4-ø6.8 350 380 410 CAUTION PLATE FOR FRESH / SEA SWITCH 430 460 COAMING 40X80 160 360 380 410 430 4-M6 15

16