SENSOR DDS MIT. Dry Geomembrane Mobile Integrity Arc Tester. ASTM D7953 approved. SENSOR - Inventors of Geomembrane Leak Detection Systems SENSOR

Similar documents
INSTALLATION QUALITY-ASSURANCE GUIDE FOR SOLMAX-GSE S CONDUCTIVE LINER

PED Workshop Nicosia, 3-5 October, 2005

October 7, 2016 Meeting Landfill Liner Regulations with Conductive Backed Geomembranes by Doyin Adesokan B.Eng Msc. Technical Manager - Solmax

Dräger REGARD -1 Control System

Dräger REGARD -1 Control System

Dräger Polytron 7000 Detection of toxic gases and oxygen

DEFECTOVISION IR. Non-Destructive Testing of Steel Billets and Tubes

Elcometer 4340 Motorised/Automatic Film Applicator. elcometer.com 1

Leak Location Geosynthetic Materials in Base Liner Systems. NY Federation SWANA. May, 2014

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Impermeable Liner

HAUBER-Elektronik. Product overview. Condition monitoring Mechanical protection in compliance with DIN ISO 10816

ÍST EN :2015. Gildistaka ICS: 53.06

HazLoc Essential Guides:

SPECIAL SPECIFICATION 3687 Impermeable Liner

OPERATION MANUAL Model 8011 & mA

For more information on Tarkett go to

Package Included. Bobbie. template. stickers

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

Nondestructive Testing of Geomembranes

OPERATION MANUAL MODEL 805 ACCELEROMETER

SONAPHONE E. ATEX Certificated for the Use in Areas with Risk of Explosion. Features:

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

SOUTH AFRICAN NATIONAL STANDARD

Connecta System THE FIRE PERFORMANCE TUNNEL LIGHTING AND POWER SYSTEM

OPERATION MANUAL MODEL & ACCELEROMETER

ISO INTERNATIONAL STANDARD. Geosynthetics Determination of friction characteristics Part 2: Inclined plane test

JNW CleaningSolutions ks. Experience pays. ACC User Group. Gettysburg, September 2015 Fabian Noack

INTRODUCTION TAQQAT Global Co. Abdulla Fouad Group

Dräger VARIOx-2. Electronical measuring device for the gas concentration measurement

STT 3000 Series STT250 /150 Surge Protection Device Specifications

Old documentation - Only for your information! Product is not available anymore!

Dräger X-am 5000 Multi-Gas Detector

Lined Reservoirs, Lagoons and Storm Ponds

Geomembranes that work

VM-3000 Mercury Vapor Monitor

Measuring Recording Online Monitoring Regulation Alarming

ISO INTERNATIONAL STANDARD

Dräger X-am 5000 Multi-Gas Detection

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Rules for Classification and Construction Additional Rules and Guidelines

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger X-zone 5500 Multi-Gas Detection Device

Oxylog VE300 Emergency & Transport Ventilation

WAFE 350 SMART VENTILATION EXPERT PREMIUM ENERGY RECOVERY VENTILATION

Mercury Vapor Monitor VM-3000

Operator s Manual for Morse Vertical-Lift Drum Pourers

Dräger Polytron 8720 IR Detection of carbon dioxide

ViscoClock plus AUTOMATIC VISCOSITY MEASUREMENT EASY AND PRECISE

GEOMEMBRANE FIELD INSTALLATION

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Dräger Polytron 8700 IR Detection of flammable gases and vapors

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Tropic 2.0 ultrasonic nebuliser

Process Automation. Sensors and Systems: Level Sensors Level Detectors Overfill Prevention. Process Automation. Accuracy.

Pinhole Detector Data Sheet / Instructions

SECTION 02230BP AGGREGATE BASE

Bristol Babcock Oil Content Monitor "oil in water"

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Geomembranes that work

PAC1500Xi PORTABLE APPLIANCE CHECKER

FOR PROJECTS INITIATED AFTER FEBRUARY 1, 2010 REVISION 1 ITEM 709 TRIANGULAR FILTER FABRIC FENCE

Theft Net. Already curtailing product theft on pipelines all over the world. Theft Net

Accuracy counts! Sensors with analog output

WIO200 Water In Oil measuring instrument

Harrier + Smart Controller & Chemical Management System

Dräger X-zone 5500 Portable gas detection system for flexible area monitoring

FC22 Compression Load Cell

SENTINEL D - Fault Passage Monitoring

OPERATION MANUAL MODEL 8102 ACCELEROMETER

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

METRO GROUP kicks off 2015/16 with like-for-like sales increases at METRO Cash & Carry and Media-Saturn

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

ANNEALING FURNACE MODEL 414 User Maintenance Manual/Handbook

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Low Temperature Zirconia Oxygen Analyzer

REFRIGERATING SYSTEMS AND HEAT

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

ISO INTERNATIONAL STANDARD. Welding Acceptance inspection of electron beam welding machines Part 4: Measurement of welding speed

BEKOKAT TOP-QUALITY, OIL-FREE COMPRESSED AIR

Dräger Polytron 8100 EC Detection of toxic gases and vapors

CERTIFICATE of Product Conformity (QAL1 )

Neuronics Inc. Company and Product Sales, Neuronics Inc. Applied AI Systems, Inc.

OPERATION MANUAL MODEL 4610 ACCELEROMETER

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Paints and varnishes - Corrosion protection by protective paint systems - Assessment of porosity in a dry film (ISO 29601:2011)

Dräger X-am 5000 Multi-Gas Detection

Dräger REGARD 3900 Series Control System

Federal Law of the Russian Federation of December 27, 2009 N 347-FZ "Technical regulation on safety of low-voltage equipment" Part I

PL400 Patient Lift Scale Indicator Owner s Manual

Geosynthetic materials Solutions for improved ground structure. Name it. We ll do it.

Company. profile MANUFACTURER OF LIGHTING MANAGEMENT SYSTEMS AND WIRELESS SENSORS FOR BUILDING AUTOMATION

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

Energy you can recycle

RADIOCOMMUNICATIONS (EMC STANDARDS) NOTICE 2004 No. 2

Civil engineering Fibertex Geotextiles

PQS performance specification

Transcription:

SENSOR ASTM D7953 approved SENSOR DDS MIT Dry Geomembrane Mobile Integrity Arc Tester

Introduction was established in 1990 and since then has become the world s leader in leak detection systems. With over 23 year s existence, Sensor has developed high quality products under the registered trademark. From its base in Slovakia Sensor s.r.o. has established subsidiary companies in: Germany United Kingdom Chile Czech Republic Russian Federation At the present, Sensor is active in more than 45 countries and has applied its systems on more than 1150 projects. Sensor s electronic leak location and detection technology has been used successfully to monitor and protect in excess of 19 million square meters of geomembrane liners.

Product Family is the trademark for the family of monitoring systems created by Sensor s.r.o. to locate leaks. These systems are split into two broad sub-categories, FIXED and MOBILE. Further sub-divisions can be seen on the chart below. PRODUCT FAMILY MOBILE SYSTEMS MOBILE FIXED SYSTEMS MIT RMS ONLINE SYSTEMS (24/7) CMS OFFLINE SYSTEMS LAM LMS

MIT Technology MIT technology was developed specifically for the quality control of exposed geomembrane liners such as synthetic membranes / liners, or asphalt. Even where the damage is less than 1mm2 the equipment will generate an audio visual alarm to warn the operator that damage has been encountered. It is employed directly after the installation of a liner. The system electronically verifies the integrity of the entire surface including welds. This enables you to find all defects (e.g. caused by installation, manipulation, transit, or following trades) down to invisible pinhole sized damage. MIT can also be used in double lining systems where conductive-backed geomembrane can be added as a solution for testing the upper geomembrane or in case of two non-conductive geomembrane system, conductive geotextile must be installed as a middle layer. Non Conductive Geomembrane Ground or Conductive Geotextile

MIT Power - green led Damage / Hole - red led Battery status display Spark intensity regulator On/Off Switch Battery pack and data logger Probe (standard length 1m)

Technical Specification Adjustable output voltage range: 6-30kV DC Variable sensitivity: 0-3 ma Maximum continuous current: <3mA Operating time on full battery: min 16 hours Meter accuracy: +/- 1% Mains voltage for charging: 110 to 240V AC, 50/60 Hz Weight (unit only): 1.2-3.2kg (2.6-7lbs) depends on the model Dimensions (unit only): 159cm length x 6cm deep Packed Weight: 15kg Dimensions (packed): 100cm x 41cm x 15.5cm Battery: 12V, 4.5Ah or 7.2Ah Note: Due to ongoing technical developments, all stated information is typical and is subject to change without notice or obligation

MIT vs Common Water Based Detection Method SENSOR DDS MIT Water based detection method Doesn t require water to operate, MIT can be applied on a completely dry surface (small non conductive residuals could be present) One operator can test up to 6000m² per day depending on site conditions. For large areas, multiple units can be used. Zero interference between units means multiple operators can work simultaneously so your project will never be late Can detect pinholes Easy of use. Audio and visual alarm warns operator when hole is detected. No training is required MIT system weighs only 3kg and that s all what operator will carry during survey MIT is a much quicker method than any based methods means also that is more cost effective Works only with the supply of a large amount of water This method is very time consuming, setting up many metres of hose and lances in addition to the electrical testing equipment used Unable to detect very small damage less than 1mm² in size Operator has to receive expensive training Operator has to carry heavy equipment. Water hoses require setting up for each lane Comparatively expensive system needs multiple operatives to set up and test. Remote locations without water supplies mean that water has to be transported in

Certificates In respect to continually growing requirements in both home and foreign markets, our company acknowledges its responsibility for managing and ensuring quality and protecting the environment, as well as for protecting the health of its employees while they work. The mutual effect of these elements resulted in the company s management system receiving ISO 9001:2008 certification issued by SGS. SENSOR DDS MIT complies with all enforceable EU standards, norms and regulations (High voltage directives, Electromagnetic compatibility, Environment etc.)

MIT Models MIT LT (LIGHT VERSION) MODEL MIT MIT XL (EXTENDED VERSION) LENGTH 1.5m 1.5m 1.5-4.5m (adjustable) EFFECTIVE WEIGHT 1.2kg 2kg 3.2kg BATTERY STATUS DISPLAY BACKPACK ON BODY ON BODY INTENSITY REGULATOR BACKPACK ON BODY ON BODY PRICE ON REQUEST ON REQUEST ON REQUEST AUDIO VISUAL ALARM VOLUME REGULATOR This equipment is also available in different color variations

Contacts Obchodna 8 902 01, Pezinok Tel: +421 2 20 901 080 Irwell House, The Grove Manchester, M30 0ET England SENSOR DKS GmbH. Torstraße 1 D-23570, Lübeck Germany Tel: +49 45 02 999 300 Email: office_de@sensorgroup.com SENSOR LA S.A. Calle Renca 2210 Renca, Santiago Chile Tel: +56 9 98 712 816 Email: office_cl@sensorgroup.com For more information please visit our website www.sensorgroup.com