Devilink RS Installation Manual GB-DAS

Similar documents
MAKING MODERN LIVING POSSIBLE INT INT EFIT 550. User Guide and Installation Manual. Danfoss Heating

Click & Plug Floor Heating. Installation instruction Devidry Kit

GB/DAS Installation Instructions

Installation Instruction Devidry - for installation with Devidry Pro Kit

EFET 535. Installation Manual INT INT

AUS. Devireg TM 535 Installation and user manual

Thank you for buying a DEVI product. With this purchase you have obtained a product of the highest quality, designed to give long lasting comfort at

GB-DAS. Installation and user manual DEVIreg 850 controller

Installation Instruction

Installation Guide DEVIlink FT Floor thermostat

Danfoss Link FT Floor Thermostat

Installation Instructions. devireg 700/ /752/753/754

Varenummer: Version:

Installation And User Instructions

INSTRUCTION. Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors. Danfoss heating cable mat type 100/150

DEVI underfloor heating systems

Installation Instructions EFET 610

Article: Version:

Installation And User Instructions GB/IRE. Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter

Table of Contents. Features Quality Policy Section A - Unit Operation Section B Unit Maintenance Trouble Shooting Guide...

U S E R M A N U A L UBH1RF HEAT ALARM

Model: 1001T/LCD-A INSTALLATION AND OPERATING INSTRUCTIONS

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance...

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

External Wireless Sounder

Installation And User Instructions. devimat Warm Floor System Installation Instructions User Guide Trouble Shooter

Motion tracking. sensor led light. Installation & operating manual NIGHTWATCHER. Model no: nw1200x

Installation And User Instructions. Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter

External Wireless Sounder

High Frequency Sensor

Drying Cabinet With Timer

Operating Guide: for the Warmup Tempo Digital Programmable Thermostat Part of the Element Series

Installation Guide. DEVIreg 330 (-10 to+10 C) Electronic Thermostat.

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Setting the Timer...

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

T6 Pro Hydronic. User Guide. Thermostat controls. Customer assistance. Programmable Thermostat

636 and 646 Keypads. User s Manual

Portable Refrigerator

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

Operating Guide: for the Warmup tempo Digital Programmable Thermostat Part of the Element Series Introduction

Model: TS/R-2A INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS

Installation and Operations Manual

OWNER S MANUAL. CoolTower CTF07. (English) (CTF07)

Installation Manual. Frost Protection Cable. Warmup Ireland Web: Telephone:

Installation Guide. DEVIreg Smart. Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control.

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

RadioLINK + Module EIB600MRF for Battery Powered Smoke / Heat Alarms EIB600 Series

Installation and User Guide living connect Electronic Radiator Thermostat

Installation Guide. DEVIreg Touch. Electronic Intelligent Timer Thermostat.

18W Round LED Wall/Ceiling Light with Microwave Sensor

70L FRIDGE USER MANUAL

Thermostats. Digital Programmable. GEAppliances.com

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

Installation Guide. DEVIreg 535. Electronic Thermostat.

INSTRUCTION MANUAL / INSTALLATION MANUAL. 7kg Vented Dryer MODEL: KA7VENTDRYA

SC Installation, Operation & Application Guide

Installation Guide. DEVIreg Smart. Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control.

M1200 Series Limited Warranty Dependability Promise

Vanity Installation Instructions

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

DTS SECURITY P.O.BOX 3399 Base plate-mounting EDENVALE instructions 1610 TELEPHONE

Digital Programmable

LIGHTNING VAULT WALL MOUNT SINGLE HANDGUN

Honeywell Homes T3, T3M & T3R

ELECTRIC UNDERFLOOR HEATING SYSTEMS. Operating Guide & Guarantee. The Underfloor Heating Specialists Tel:

How to control rooms you rarely enter. Fighting for bare feet. Devilink Wireless control, comfort and convenience. Intelligent heating

WS-9023U 915 MHz Wireless Weather Station. Instruction Manual

Mira Vision Wireless Controller

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

Foil Heaters. Installation Manual: TECHNICAL HELPLINE

Automatic Phone-Out Home Monitoring Systems

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

240 ASSEMBLY & OPERATION MANUAL

Instruction Manual. Chest Freezer MODEL: KI130CF2

Installation Guide. DEVIreg 534. Electronic Thermostat.

LYRIC T4, T4R& T4M PRODUCT SPECIFICATION SHEET FEATURES

Thermostat Series. Installation Manual TSTBM-RRS--TW-A Revised 02-13

JA-63 Profi User manual

12W Round LED Wall/Ceiling Light with Microwave Sensor

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

SPECTRA 1727 USER S GUIDE

DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive

DEVIreg 330 (+5 to +45 C) Electronic Thermostat

Parts Identification and Accessories Safety Information Installation Control Panel Layout Fully Automatic Washing...

IMPORTANT INFORMATION

ETLW7. Product: 7kg Top Load Washing Machine. User Manual

Contents. English. French. Spanish

WS-8300U 915 MHz Wireless Weather Station Instruction Manual

Series Automatic Hand Dryer. Operating Instructions for the User & Installation Instructions for the Licensed Installer

R A D I A N T O U T D O O R H E A T E R S OPERATION, INSTALLATION AND MAINTENANCE MANUAL. TT-MTM Wall Controller

Instruction Manual. Please read this manual and the Safety Instructions carefully before using your refrigerator.

Heat Electric Radiators Installation and Operating Instructions INSTALLER PLEASE NOTE: LEAVE INSTALLATION AND OPERATING INSTRUCTIONS WITH CUSTOMER

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

Assembly instructions and instructions for use for electric sauna oven with evaporator. Bi-O-Mat W MADE IN GERMANY IPX en / -44.

Ambient Weather WS Channel Wireless Thermometer with Min/Max Display User Manual

Heating Control Danfoss Link & Connect Thermostats

OWNER S MANUAL. Convair Tower Heater CTH09. (English) (CTH09)

Transcription:

Devilink RS Installation Manual GB-DAS

Devilink RS The Devilink RS (Room Sensor) has a built-in temperature sensor which measures the ambient temperature. It allows you to control the heating based on room temperature, in the room where installed. With the Devilink RS you can also adjust the temperature. Installation scenario: Devilink CC Devilink FT Ambient temperature Floor temperature Communication/link test Battery warning Tamper proof. Locked by CC 2

Placement of Devilink TM RS Not on a wall where it will be subjected to direct sunlight. Installation height should typically be between 80-150 cm. In wet rooms it should be installed on an even surface, according to local building regulations. At least 50 cm away from windows/doors that will be left open occasionally. Not on the inner side of a wall facing the outside. 3

3. Installation Light indications of Devilink (LED) RS 1. Remove the front cover by gently pressing the release tab on the bottom side of the sensor. 2. Mount the room sensor a. Mark up drill holes b. Drill holes c. Place fixing plugs in holes d. Screw mount the RS 3. Mount batteries 4. Put front cover on by placing the top of the cover in place first and then gently press the bottom end in place. 4 Configuration: See Step-by-Step guide in Devilink CC instruction manual.

Trouble shooting Short green flash Green fast flash Red flash + for 5 sec. ON Red flash + for 5 sec. ON + Red LED flash every 2½ min. ON + Red LED flash every 30 sec. E5 E6 ON Flash Not included in network Inclusion in progress Inclusion failed Link test in progress Link test failed Low battery level Critical battery level Floor sensor short circuited Floor sensor lost Tamper proof enabled by Devilink CC Limited by Devilink CC Factory reset a Devilink RS: Take the front cover off. Take out one battery and hold the ON/OFF/Install button down while reinserting the battery. Keep holding down the install button until it flashes (approx. 5 sec.) 5

Technical specifications Battery Alkaline 2xAA, 1.5V Battery lifetime Backlight Ambient temperature Battery monitoring Transmission frequency Transmission range in normal buildings Transmission power IP class 21 Dimensions Up to 4-5 years Green LED -10 to +35 C The sensor has a built-in monitoring circuit, which will detect low or critical battery level. 868.42MHz Up to 30m Max. 1 mw 81 mm x 66 mm x 21 mm Disposal Instruction: Equipment containing electrical components should not be disposed together with domestic waste. It must be collected separately with other electrical and electronic waste according to local legislation. 6

The 2 Year DEVI Warranty You have purchased a DEVI heating system which we are sure will serve to improve the comfort and economy of your application. DEVI provides superior electrical heating solutions for total climate control in and around homes and buildings. DEVI offers a complete product program with Deviflex TM heating cables or Devimat TM heating mats, Devireg TM thermostats, Devifast TM fixing strips and Devi Self-limiting heating cables combined with additional products completing the product program. This 2 year warranty applies to all DEVI products. Should you, against all expectations, experience a problem with your DEVI product, you will find that DEVI offers a 2 year warranty from the date of purchase on the following conditions: During the warranty period DEVI shall offer a new comparable product or repair the product in case the product is found to be faulty by reason of defective design, materials or workmanship. Repair or replacement shall be carried out at DEVI s discretion. DEVI shall not be liable for any consequential or incidental damages including, but not limited to, damages to property or extra utility expenses. This warranty shall only be valid on production of proof of purchase and must be submitted to the installer or seller without undue delay. An extension of the warranty period following repairs undertaken under warranty cannot be granted. The DEVI Warranty shall not cover any damage caused by incorrect conditions of use, incorrect installation or if installation has been carried out by non-authorised electricians. All work will be invoiced in full if DEVI is required to inspect or repair faults that have arisen as a result of any of the above. The DEVI Warranty shall not extend to equipment which has not been paid in full. DEVI will, at all times, provide a rapid and effective response to all complaints and inquiries from our customers. The warranty explicitly excludes all claims exceeding the above conditions. Name: Warranty Certificate The DEVI TM Warranty is granted to: Address: City: Country: Telephone: Attention: The Warranty Certificate must be completed correctly for the Warranty to be valid. Please read the Warranty conditions above. Type of thermostat: Article number: Electrical installation by: Date: Suppliers Stamp:

Article: 08095916 Version: 01.01 DEVI A/S DK 7100 Vejle Phone +45 7488 8500 Fax +45 7488 8501 VICKC102 09/2009 8