Instruction Manual December 2001 ENACOCU02

Similar documents
Instruction Manual August sitrans CU 02

CU-02 with Senaco Plus

Instruction Manual April sitrans AS 100

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Instruction Manual July 2008 TS-2 TEMPERATURE SENSOR

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH. Instruction Manual August 2002

Quick Start Manual July pointek CLS100

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

POINTEK CLS 200 OINTEK CLS 200 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual December 2001

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Analog Room Pressure Monitor RPC Series

multiranger 100 / 200

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Process Alarm Module RTA 421

LC2200 Level Controller Installation and Maintenance Instructions

Oxygen (O2) Single-Point Gas Detection System

EXTINGUISHING AGENT RELEASE MODULE

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Combustible Gas Detection and Control System

Two-Channel Gas Controller

Carbon Monoxide Transmitter

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

Functional Safety Manual June pointek CLS500/LC500

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

B-40/B-41 Modulating Temperature Controller

Ultrasonic switch. Pointek ULS200. Quick Start Manual 03/2013. Milltronics

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Duct and Rough Service Carbon Monoxide Sensor

CTT8 TEMPERATURE MONITOR DEVICE

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

INSTALLATION INSTRUCTIONS

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

Pioneer-R16 Gas Monitor Operator s Manual

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

POINTEK CLS 300 OINTEK CLS 300 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual December 2001

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

MO n : 12JMC rév A

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Pump-Down Controller MODEL 4052

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

DIGITAL METERS Large Display Temperature Meters Instruction Manual

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

10yr O2NE & Safe-Ox. User Manual

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Pump-Up Controller MODEL 4062

Product Manual SZ1145

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Oakton TEMP 9500 Advanced Multiparameter Controller

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Product Manual SZ1144

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Greentrol Automation, Inc.

Digital Electronic Thermostat With RF

CMD420 / CMD421 Series

APC BC300 Series 40kW 208/450/480V User Guide

Flopurge TS. Operation Manual

Multi-Gas-Controller MGC2

Operating Instructions. For. Alarm Control Module. Model SSR 500

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

MTRA-FSP Level Control Relay. Installation & Operation Manual

Beacon 800 Gas Monitor Operator s Manual

INTRODUCTION / TABLE OF CONTENTS

UDC100 Universal Digital Controller Specifications

User Operation Manual

ZSC100 Gas Detection and Alarm System Controller

Beacon 110 Gas Monitor Operator s Manual

BX444-Mc Gas Detector

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

PRODUCT CONFORMITY CERTIFICATE

C-Bus Four Channel General Input Unit Installation Instructions

LC3000 Level Controller Installation and Maintenance Instructions

UNC100 Integra Manual

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller

D3000. Installation & Setup Guide

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Transcription:

SENACOCU02 Instruction Manual December 2001 ENACOCU02

Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. Warning: This product can only function properly and safely if it is correctly transported, stored, installed, set up, operated, and maintained. Note: Always use product in accordance with specifications. Copyright Siemens Milltronics Process Instruments Inc. 2001. All Rights Reserved This document is available in bound version and in electronic version. We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments Inc. Siemens Milltronics Process Instruments Inc. will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions. Disclaimer of Liability While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement. Technical data subject to change. Contact Technical Publications at the following address: Technical Publications Siemens Milltronics Process Instruments Inc. 1954 Technology Drive, P.O. Box 4225 Peterborough, Ontario, Canada, K9J 7B1 Email: techpubs@siemens-milltronics.com For the library of SMPI instruction manuals, visit: www.siemens-milltronics.com Siemens Milltronics Process Instruments Inc. 2001

About the Senaco CU 02 Note: CU 02 is to be used only in the manner outlined in this instruction manual. The Senaco Control Unit, CU 02, provides relay and analog outputs for interfacing a Senaco AS100 Sensor into a process. Features - LCD display - 2 SPDT (form C) relays - 4-20 ma output, isolated - programmable start up delay - programmable alarm delay 7ML19981DN01 Senaco CU 02 Page 1

Specifications Power:! see nameplate for voltage configuration (100/115/200/230 V ac ±15%, 50/60 Hz, 10 VA) Environmental:! location:! indoor! altitude:! 2000 m max! ambient temperature:! -20 to 50 C (-4 to 122 F)! relative humidity:! 80% for temperatures up to 50 C! installation category:! II! pollution degree:! 2 Sensor Excitation:! 26 Vdc nominal, 70 ma max Input:! Senaco Sensor 0 10 Vdc Display:! liquid crystal! three 9 mm (0.35") digits! multisegment graphic for operation status Relay:! 2 alarm/control relays! 1 form C SPDT contact per relay, rated 5 A at 250 V ac non inductive Analog Output:! isolated 4-20 ma! 750 Ω load max Enclosure:! 55 mm W x 75 mm H x 110 mm D (2.2" W x 3" H x 4.4" D)! polycarbonate! mounting: - DIN rail (DIN 46277 or DIN EN50022) - wall / panel mount Ingress Protection:! IP 20 Approval:! CSA general purpose Weight:! 550 g (18 oz) Page 2 Senaco CU 02 7ML19981DN01

Installation Notes: Installation shall only be performed by qualified personnel and in accordance with local governing regulations. This product is susceptible to electrostatic shock. Follow proper grounding procedures. Mounting Dimensions 110 mm (4.4") 75 mm (3") 61 mm (2.4") 55 mm (2.2") 38 mm (1.5") 4.5 x 5.75 mm (1.8" x 0.2") mounting slot (2 places) Wall / Panel Mounting 38 mm (1.5") 61 mm (2.4") drill and tap for 4 mm (#8) screw, (2 places) 7ML19981DN01 Senaco CU 02 Page 3

Rail Mounting Mounting Removal Page 4 Senaco CU 02 7ML19981DN01

Interconnection Connection Layout WARNING: All field wiring must have insulation suitable for at least 250V. Relay contact terminals are for use with equipment having no accessible live parts and wiring having insulation suitable for a least 250 V. The maximum allowable working voltage between adjacent relay contacts shall be 250 V. Senaco AS100 Sensor Connection Standard Temperature Version or* red black green black black white shield Extended Temperature Version or* red black orange green brown yellow *sensor range selection high sensitivity range = green to Vsup low sensitivity range = green to com shield *sensor range selection high sensitivity range = orange to Vsup low sensitivity range = orange to com 7ML19981DN01 Senaco CU 02 Page 5

Relay Output Connection* Auto Reset Manual Reset (P14 / 24 = 0) (P14 / 24 = 1) reset button All relays are certified for use in equipment where the short circuit capacity of the circuits in which they are connected is limited by fuses having ratings not exceeding the rating of the relays. *refer to Operation \ Alarm Analog Output Connection Power Connection to customer instrumentation 4 20 ma isolated output into 750 Ω max Refer to nameplate for voltage requirement The equipment must be protected by a 15 A fuse or circuit breaker in the building installation. A circuit breaker or switch in the building marked as the disconnect switch shall be in close proximity to the equipment and within easy reach of the operator Page 6 Senaco CU 02 7ML19981DN01

Operation Start Delay On initial powering of the CU 02, the start delay circuit prevents the relays from going into alarm for the period of time programmed (parameter P80). Display program relay 1 alarm flag alphanumeric % percent reading relay 2 alarm flag parameter value The CU 02 normally displays the input signal level (Vsens) from the Senaco sensor in volts, or in percentage of the programmed span (P3 P2). The selection is made while viewing Vsens. Press: for percent Press: for volts Damping is provided to slow the response of the display when rapid or minor fluctuations in the process or machinery operation are encountered. The greater the damping value (P86), the slower the response. Relay The CU 02 has two onboard programmable relays (P10/20). Under normal operation, the relays are energized (normally open contact closed). Under alarm condition, the `alarm' flag starts flashing immediately, indicating that the relay delay (P13/23) has started counting. If the alarm condition ceases before the relay delay expires, the flashing `alarm' flag is aborted. If the relay delay expires, the relay de-energizes and the contacts change state. The `alarm' flag ceases flashing and remains on. Upon resumption of normal operating condition, the `alarm' flag disappears. The relay and relay delay reset manually or automatically depending on the mode selected (P14/24). If automatic, the reset is immediate. If manual, the reset occurs upon actuation of the reset button (latch). 7ML19981DN01 Senaco CU 02 Page 7

Each relay is programmable for either: high alarm: low alarm: out of bound in bound: alarm condition occurs when on the sensor signal level (%) is off of a greater value than the high% setpoint on alarm condition occurs when off the sensor signal level (%) is of a lesser value than the low% setpoint alarm condition occurs when on the sensor signal level (%) is off of a greater value than the high% alarm setpoint or of a lesser value than the low% alarm setpoint alarm condition occurs when on the sensor signal level (%) is off of a value between the low% and high% alarm setpoints e.g. alarm above 80% e.g. alarm below 20% e.g. alarm beyond 20% and 80% e.g. alarm between 20% and 80% The individual relay functions in combination provide: high% and high-high% alarm high% and low% alarm high% and bound alarm low% and low-low% alarm low% and bound alarm bound 1 and bound 2 alarm Note: if the Senaco AS100 sensor is located in areas with high RF noise, then the alarm setpoints should be set to 0.50 V above or below the fault/no fault conditions Analog Output The CU 02 provides an isolated analog 4-20 ma output by calibration of the 4 and 20 ma levels to the operating span of the input signal (Vsens) from the Senaco sensor. In the case where Vsens passes the lower and upper limits of the span, low and high ma limits are factory set to nominal values of 2 and 22 ma respectively, providing indication of overrange activity. Damping is provided to slow the response of the analog output when rapid or minor fluctuations in the process or machinery operation are encountered. The greater the damping value (P85), the slower the response. Page 8 Senaco CU 02 7ML19981DN01

Security The CU 02 is factory shipped with security (P 1) disabled, allowing program access. If it is desired to deny programming access (viewing access is not restricted), security can be enabled by entering the enable code. If it is desired to regain programming access, the disable code must be entered. Refer to Security Alteration. Parameter Reset A master reset (P99) is provided to automatically reset all programming parameters to their factory values. However, if it is desired to reset an individual parameter, this can be done by entering its factory value, as given in Parameter List. 7ML19981DN01 Senaco CU 02 Page 9

Setting Up To Access Program: To Select a Parameter: Press Display run display program starts at parameter 1 to scroll up or down to desired parameter To View a Parameter Value: To Change a Parameter Value: Security must be disabled! Must be pressed to Save change! select parameter, e.g. P3 display parameter value, e.g. 2.50 exit select parameter, e.g. P3 display parameter value, e.g. 2.50 increase or decrease to the desired value If no response, security not disabled! save and exit To Return to Run Display: from the parameter display, e.g. P 3 exit program and return to run display Page 10 Senaco CU 02 7ML19981DN01

Operating Values With the Senaco Sensor and Control Unit properly mounted, connected and powered. Run the material or machinery through its range of operation. Note the following values where applicable: normal operating level V norm = abnormal operating level V abn = Where applicable values are unobtainable, they can be estimated and entered while programming. 7ML19981DN01 Senaco CU 02 Page 11

Programming Note: Security must be disabled to set programming functions. Calibration: 0-100% / 4-20 ma calibrate the 0% / 4 or 20 ma level by entering the value of V norm into P 2. calibrate the 100% / 20 or 4 ma level by entering the value of V abn into P 3. The difference between P 2 and P 3 must be at least 0.2 V for full 4-20 ma span. Relays For precise determination of alarm setpoints, view the run display in percent and run the material or machinery through its range of operation. Note the % values corresponding to the alarm points. Note: The setpoints should be 0.50 V above or below the fault/no fault condition if the sensor is installed in high RF noise locations. Relay 1 enable, P10 = 1 setpoint: for high% alarm, P11 = enter setpoint value in % P12 = 0 for low% alarm, P11 = 0 P12 = enter setpoint value in % for out of bound alarm, P11 = enter high% setpoint value in % P12 = enter low% setpoint value in % for in bound alarm, P11 = enter low% setpoint value in % P12 = enter high% setpoint value in % relay delay set (1-999 s), P13 Page 12 Senaco CU 02 7ML19981DN01

reset select, P14 auto = 0 manual = 1 Relay 2 enable, P20 = 1 setpoint: for high% alarm, P21 = enter setpoint value in % P22 = 0 for low% alarm, P21 = 0 P22 = enter setpoint value in % for out of bound alarm, P21 = enter high% setpoint value in % P22 = enter low% setpoint value in % for in bound alarm, P21 = enter low% setpoint value in % P22 = enter high% setpoint value in % relay delay set (1-999 s), P23 reset select, P24 auto = 0 manual = 1 Ancillary Functions Damping ma output damping adjust (typical value, 1-50), P85 display damping adjust (typical value, 1-50), P86 7ML19981DN01 Senaco CU 02 Page 13

Parameter List P- 1 security, reference = 500 ƒ P- 2 0% calibration / 4 ma (V sens = 0-7.3 V) ƒ =0.50 P- 3 100% calibration / 20 ma (Vsens = 0.2-7.5 V) ƒ =2.50 P-10 relay 1, operation: 0 = disabled ƒ 1 = enabled P-11 relay 1, high alarm setpoint (0 = disabled,1 to 100%) ƒ = 80 P-12 relay 1, low alarm setpoint (0 = disabled,1 to 100%) ƒ = 20 P-13 relay 1, delay (1 ƒ to 999 s) P-14 relay 1, latch: 0 = auto reset ƒ 1 = manual reset P-20 relay 2, operation: 0 = disabled ƒ 1 = enabled P-21 relay 2, high alarm setpoint (0 = disabled, 1 to 100%) ƒ = 70 P-22 relay 2, low alarm setpoint (0 = disabled, 1 to 100%) ƒ = 30 P-23 relay 2, delay (1 ƒ to 999 s) P-24 relay 2, latch: 0 = auto reset ƒ 1 = manual reset P-80 start delay (1 to 999 s) ƒ =10 P-85 damping, ma out (1 ƒ to 999) P-86 damping, display (1 ƒ to 999) P-90 software revision number P-99 reset: 0 = normal ƒ 9 = reset ƒ factory setting accessible only if relay operation function is enabled Page 14 Senaco CU 02 7ML19981DN01

Security Alteration To Enable Security: Press Display security disabled, programming access granted reference value enable code security enabled, programming access denied To Disable Security: security enabled, programming access denied reference value disable code security disabled, programming access granted 7ML19981DN01 Senaco CU 02 Page 15

Maintenance CU 02 requires no maintenance, however a program of periodic checks is recommended. Page 16 Senaco CU 02 7ML19981DN01

*7ML19981DN01*