Product Information. PipeMonitor District Heating Monitoring with Leak Localisation

Similar documents
Dew point set DS 400

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

8.0 Table of Contents. Monitoring system WIREM

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

DATAssure. Laboratory wireless alarm & monitoring system

Parameterisable compact fault annunciator with permanent display

Universal fault annunciator for panel mounting

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Solution F2. Fire Alarm Control Panels one step ahead.

D3 Wireless temperature alarm & monitoring system family. tek-troniks

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Alarm module for leak detection with webserver

ACTIVE INFRARED BARRIER

Process Alarm Solutions

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Window facia fault annunciators

Call stations and extensions

Smart Wireless Sensor

Panel Mounted Fault Annunciator Series

Facility Explorer Asset Protection by Yorkland Controls Ltd. Fr

EASY THE SECURITY SYSTEM BUILT AROUND YOU

Advanced Power Monitor (APM)

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

CAN unit for Analog Sensors

Intelligent addressable fire alarm control panel

Batt-Safe Battery String Monitoring System

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Insulation fault evaluator EDS460-DG

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Typical applications include the vibration detector. Detection of vibrations and shocks

On the job around the clock 24/7: Fire detection systems

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

The EN54 Part 2 & 4 Fire System

CSP-204 CSP-208 CSP-104 CSP-108

Remote fiber testing to improve SLA s

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Universal Input Digital Panel Meter With Bargraph, NA3

RACK MONITORING SYSTEM RAMOS Ultra

Smart Wireless Sensor

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

600 Range Dialer Installation Manual. Version 1.0

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Outdoor Temperature Sensor

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

02/11/2015

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

M1000 Alarm Annunciator

NETx Voyager Visualization

RAYCHEM NGC-30 COMPONENTS

GRUNDFOS INSTRUCTIONS. Dedicated Controls. Service instructions

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

GAS EXTINGUISHING SYSTEMS COMPACT EXTINGUISHING SYSTEMS. OneU. Fire Protection Systems for 19" Racks

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Process Alarm Module RTA 421

AmpLight group management

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

FireNET Plus Wiring Instructions

Info-Display xx

C-Bus Four Channel General Input Unit Installation Instructions

Cold chain monitoring technologies. Facility monitoring

Description of the. controllers. Description of the. system extension possibilities. RS communication. Front panel made of glass. Control of 2 valves

Tri-Tech Medical Inc.

Clino Guard. Intelligent Life Care. Solutions for safe and efficient care

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

For Complete Fire and Gas Solutions

Gas Controller Module GC-06

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

MCS 4000 Control Panel

VIBRA-series: VIBRA, VIBRA +

Med Touch Master Alarm

Planning Instructions MEW01776 Revision -

Interface and EOL Modules 8

Planning Instructions MEW01090 Revision 4

XC10 Extinguishing control panels

Tixi Alarm Modem Aluminum Housing Analog / ISDN / ISDN & Fax / GSM

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

User manual. KNXpar. version

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

AirFlow Sensor for Dry Contact connection

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Different types of Fire Alarm System

MODEL 5100 VOTING LOGIC MODULE

HD COMMUNICATOR. Features & Benefits: Unique continuous Redundant Routing capacity. Up to 20km reach on a single copper pair.

System 9000TS Sequence of Events Recorder

The EN54 Part 2, 4 and 13 Fire System

Remote alarm indicator and test combination MK2430

A-ISOMETER IRDH575. Operating Manual

NU2 Smart Power Supply (SPS) Manual

Transcription:

The thresholds for insulation and loop resistance are programmable via built-in buttons which are shown in the display of the main module. In addition to the settings the display can also indicate the current measuring values. The leak locating District Heating Monitoring System monitors the insulation and loop resistance of the surveillance pair in the insulation layer of district heating pipes (both Nordic System and NiCr-System ) according to EN 14419. The simultaneous surveillance of flow and return line ensures the early detection of e. g. pipe leaks, measuring loop interruption or pipe connection rupture already in the initial stage. Immediately triggered alarms prevent from cost intensive larger damages due to subtle long-term leaks. The recognises occurring additional leakages as well and triggers an respective alarm while surveilling NiCr-Systems. NiCr-System Each module continually checks the integrity of the measuring loop thus implementing a pipe connection control. It triggers an alarm in case of a rupture. All important data like measuring values, date/time stamps and fault locations (NiCr-system only) are stored daily to the internal memory of the. The datasheet can be retrieved as a csv file. For the remote alarm system the is equipped with built-in dry output contacts. Additionally it can be connected to telecontrol systems or the LANCIER UMS System via different interfaces. Pipe Surveillance pair Insulation Sheath Interface options for failure/alarm reports: - Alarm contact output (dry contact) - Ethernet - RS 485 - LANCIER Monitoring Tx-Bus - GSM/GPRS Insulation and loop resistance alarms may be acknowledged directly at the by push-buttons. Nordic System Sample: -4C

System diagram application field IP network by Ethernet or RS485 Network operator GSM/GPRS Alarm output contacts -4C: two 2-Channel measuring modules Alarm output contacts Further modules for physical parameters like - contacts (floating switches, door contacts etc.) - temperature - humidity - pressure : : -2C: one 2-Channel measuring module Alarm display in web browser...... with geographical indication.

System diagram communication Communication alternatives 1. UMS-Server Comfortable measurement collection and administration with flexible alarming. 2. Integrated Webserver For configuration tasks and memory read-out by direct IP access. 3. Telecontrol by Mod-Bus Measurement collection and administration. 4. Option SMS reports Immediate notification of alarms by SMS. Data transmission and configuration Alarm outputs -2C up to 10C

Technical Data Supply voltage Display Interfaces Measurement channels Measurement range insulation Resolution insulation Measurement range loop Type short Resolution loop Location tolerance (type NiCr only) 100.. 240 V AC, 50.. 60 Hz Graphic display, blue back-lit Ethernet 10/100 Mbit/s RS485 2.. 10 (for flow and return line of a district heat pipe) 0.. 50 MΩ, fault ±1 % of measured value, ±5 digits 0.001 MΩ 0.. 9.999 kω, fault ±1 % of measured value, ±5 digits 0.. 5 kω, fault ±1 % of measured value, ±5 digits 0.001 kω ±0.2 %, ±1 m for insulation values < 1MΩ for sensor wire 5.7 Ω/m Measuring voltage 24 V DC and < 100 ma (accoring to EN 14419) Signal LEDs red/green: insulation condition red/green: loop condition blue: display operation Local User Interface Set threshold insulation resistance and loop resistance Measurement deactivation, Fault location (type NiCr only) 5.7 Ω/m Signal outputs per measuring channel Max. switchable voltage / current 2 dry change-over contacts for: insulation resistance, loop resistance 100 V DC / 0.1 A DC Operating temperature -20 C.. +50 C Admissible air humidity 0.. 50% at 40 C, 0.. 100% at 25 C Protection class Dimensions of each unit IP 66, dust tight and water protected 273 x 440 x 186 mm (W x H x D, incl. PG screw connections) Sample: -2C

Ordering Data multi-channel measuring system for district heating monitoring equipped with display, control panel and signal output via dry contacts Type NiCr incl. length measurement and fault localisation -2C fix for 1 track (flow + return line), length up to 1500 m, not modularly extendable Order-no. 075051.202-2C short for 1 track (flow + return line), length up to 750 m Order-no. 075050.102-2C for 1 track (flow + return line), length up to 1500 m Order-no. 075050.202-4C for 2 tracks (flow + return line), length up to 1500 m Order-no. 075050.204-6C for 3 tracks (flow + return line), length up to 1500 m Order-no. 075050.206-8C for 4 tracks (flow + return line), length up to 1500 m Order-no. 075050.208-10C for 5 tracks (flow + return line), length up to 1500 m Order-no. 075050.210 Type Cu with measurement value storage, without length measurement and fault localisation -2C Cu plus for 1 track (flow + return line), length up to 4000 m Order-no. 075050.502-4C Cu plus for 2 tracks (flow + return line), length up to 4000 m Order-no. 075050.504-6C Cu plus for 3 tracks (flow + return line), length up to 4000 m Order-no. 075050.506-8C Cu plus for 4 tracks (flow + return line), length up to 4000 m Order-no. 075050.508-10C Cu plusfor 5 tracks (flow + return line), length up to 4000 m Order-no. 075050.510 Optional modules RM-T2 Measuring Module for 2 PT 1000 temperature sensors Order-No. 074700.000 RM- Contact Monitoring Module for 2 contacts Order-No. 074008.000 RM-Tx Measuring Module for up to 127 Tx-bus sensors (e.g. float and contact switches) Order-No. 074005.000 Sample: -10C