Fire Codes: A Foundation of Safety for a Rapidly Changing World

Similar documents
Fire Sprinklers Working Group Final Report

Setting the Standard in Third-party Certification

Abu Dhabi Conformity Assessment Scheme for Fire Pumps

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

9 Standards, Regulations and Authorities

Sprinklers in Europe known problems and misconceptions. Alan Brinson

NFPA Talking Points on NFPA 1 Fire Code update to the 2015 Edition:

Fixed fire protection solutions

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C

Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit

High Rise Buildings with Combustible Exterior Wall Assemblies: Fire Risk Assessment Tool

The Macro Quallty Assurance System for Fire Safety Engineering

Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services

ISO/TS TECHNICAL SPECIFICATION. Fire detection and alarm systems Part 9: Test fires for fire detectors

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P THE ROLE OF THE FIRE PROTECTION ENGINEER IN THE CONSTRUCTION DESIGN PROCESS

Transition to a New Hazard Based Safety Standard, IEC

Update - Home Improvement

BUSINESS PLAN CEN/TC 10 LIFTS, ESCALATORS AND MOVING WALKS EXECUTIVE SUMMARY

Medical devices and electromagnetic compatibility. Addressing the requirements of IEC , 4 th Edition

SOUTH AFRICAN NATIONAL STANDARD

BUSINESS PLAN CEN/TC 301 ROAD VEHICLES EXECUTIVE SUMMARY

Report on First Revision June 2014 NFPA 5000

DUST EXPLOSION CODES AND STANDARDS: Ensuring Regional Compliance and Global Consistency

NFPA Marine Fire Protection Codes and Standards An Overview. Guy R. Colonna, P.E. National Fire Protection Association. Quincy, MA USA

SERVICE VERSUS REMOVAL OF OBSOLETE COMMERCIAL KITCHEN PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

NOTICE. (Formulated under the cognizance of the CTA R3 Audio Systems Committee.)

Water Mist Fire Suppression

BUSINESS PLAN CEN/TC 162 PROTECTIVE CLOTHING INCLUDING HAND AND ARM PROTECTION AND LIFEJACKETS EXECUTIVE SUMMARY

A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

Gas Appliance Safety. Craig Grider. Compliance NRTLS and Certification Guidance. Assistant Chief Engineer Gas Products

The Route to Third Party Certification

Managing technical risks

James E. Beyer Partner

Legislation, Standards and Technology. Figure 1: 1897 Approved Electrical Fittings

MULTI-PHASED FIRE ALARM AND MASS NOTIFICATION SYSTEM UPGRADES: The Authority Having Jurisdiction (AHJ) and Proper Planning

Reliable, effective, and powerful fire protection

NEW ENERGY IN THE BATTERY INFRASTRUCTURE

Third Party Certification:

Procedure for the Approval of New Fire Detection and Alarm Technologies

Standards in Security Shutters & Fire Shutters (UK & USA)

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

world natural refrigerants trends market availability, technology trends & the impact of policy

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

A COMPARISON OF FIRE ALARM SYSTEM REQUIREMENTS IN THE US AND UK. James R. Lugar Jr., P.E. Rolf Jensen & Associates, Inc. SFPE 2012 Savannah, GA

BUILDING, FIRE, AND LIFE SAFETY CODE ENFORCEMENT AND CERTIFICATION OF INSPECTORS FOR HEALTH FACILITIES LICENSED BY THE STATE OF COLORADO

Table EXIT ACCESS TRAVEL DISTANCE a OCCUPANCY SYSTEM SYSTEM. A, E, F-1, I-1, M, b,d R, S-1. B c. F-2, S-2, U c

Introducing the Good Practice Notes on Life and Fire Safety for Hotels and Hospitals

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

Properties that are determined to be architecturally and/or historically significant may be designated as one of the following:

FIRE PREVENTION AND PROTECTION*

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

SECTION REGULATORY REQUIREMENTS. A. Relationship between Code, Ordinances, Standards and Contract Documents

3M Novec Fire Protection Fluid

The Worldwide Use of Fire Sprinklers

Standards and third party certification

New requirements for IEC best practice compliance

Managing Fire Safety in Occupied Buildings FM Ireland Fire Safety Theatre

Secretary of State determination under article 36 of the Fire Safety Order

City of Kingston Heritage Commemoration Program Guidelines: 7 May 2010

DRAFT NFPA 805 TRANSITION PILOT PLANT OBSERVATION GUIDANCE

Fire and gas safety systems:

Colorado Division of Fire Prevention & Control, Fire & Life Safety Section

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

Materials Testing by Gregory Havel

We are needing a global trademark protecting system.

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

Tudor House, Kingsway Business Park Oldfield Road, Hampton, Middlesex, TW12 2HD Phone: +44 (0) Website:

facilities like hotels, academic institutions and hospitals.

Dubai gears up for global security, safety, and fire protection trade fair, Intersec 2019

MISSION To prevent the loss of life and property and to reduce injury by providing emergency response, education and prevention services.

COMPANY OVERVIEW IN PURSUIT OF OUR COMPANY GOALS WE ARE COMMITTED TO: - Continual improvement. - Trained and dedicated personnel

microfast and microfasthp quick conventional sprinklers

Global innovation in fire fighting

Working Paper Series 09/2008. The strategic role of the plant in international networks: a longitudinal study

TECHNICAL SPECIFICATION

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

Fire System Testing Requirements Guideline Mirmgate

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

ILED Aquarius CIRCLE-H Mk 2 Helideck Lighting System

Glenwood Springs Fire Protection District Amendments to the 2009 International Fire Code

Fire Suppression Introduction Contact Information

Above Ground Fuel Tank Requirements

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

NEW YORK CITY FIRE DEPARTMENT. Notice of Public Hearing and Opportunity to Comment on Proposed Rule

The PPE Directive and the PPE Regulation

micromatic standard response stainless steel sprinklers

BUSINESS PLAN CEN/TC 58 SAFETY AND CONTROL DEVICES FOR BURNERS AND APPLIANCES BURNING GASEOUS OR LIQUID FUELS EXECUTIVE SUMMARY

Executive Summary of Qualifications

Pressure booster sets for residential and commercial buildings A COMPLETE RANGE OF SOLUTIONS FOR IMPROVED SYSTEM PERFORMANCE

INTERNATIONAL STANDARD

A NATIONAL SET OF HYDROGEN CODES AND STANDARDS FOR THE US

micromatic Standard response Horizontal Sidewall sprinkler

Introducing gas detection so intelligent, it s as close to 100% prevention as you can get

Extended Coverage Sidewall Sprinklers

Regional Municipality of Wood Buffalo. Design Review Panel DRAFT REPORT

SOUTH AFRICAN NATIONAL STANDARD

FM Approval Standard For Cavity Walls And Rainscreens

BSI the UK voice into European and national standards

Transcription:

Fire Codes: A Foundation of Safety for a Rapidly Changing World

The world s tallest skyscrapers that are transforming city skylines from Shanghai to Dubai are impressive for their architecture and engineering, but perhaps their most important design element lies in the safety of these modern marvels. Chief among these safety features is fire protection. There are myriad codes and regulations relating to fire safety in commercial buildings, from standards on portable fire extinguishers to the installation of stationary pumps for fire protection the U.S.- based National Fire Protection Agency (NFPA) alone has more than 300 consensus codes that have been adopted in whole or in part in countries throughout the world. As rapid urbanization around the globe continues to spur construction of high-rise residential and commercial structures, hospitals, schools and other buildings an expected 2.4 billion more people will live in urban areas by 2050 with over 90 percent of them in Africa and Asia applying the strictest safety measures for fire protection is paramount to safeguarding life and property. Development in these emerging markets creates both opportunities and challenges for fire service. Since there is not one widely implemented fire code that governs international new construction and building remodeling and enforcement of existing codes varies widely by country and local jurisdiction reducing costs often trumps improving safety. The 2015 New Year s Eve fire in Dubai in which flames raced up the exterior of the 63-story hotel and a 2013 fire at a nightclub in Brazil that killed more than 240 people are shocking and tragic reminders of what can happen when there are gaps in safety regulations and enforcement. (The United Arab Emirates had previously updated its Fire and Life Safety Code of Practice to ban the use of the highly combustible exterior cladding blamed for the fire, but buildings erected prior to 2012 still are vulnerable. In Brazil, there were no sprinklers in the building, though they were required by code.) These tragic events underscore the need to move toward greater uniformity in codes and standards to ensure consistent application from the initial design phase to final construction in order to 2

eliminate ambiguity and establish the highest level of fire protection in all corners of the world. Living codes Code development is generally done by Standards Developing Organizations (SDOs) in the United States, or internationally by ISDOs. These model codes serve as the basis for most building regulations, which may be amended or overridden by local bylaws or government agencies. In Europe, the prevailing standard is adapted by fire protection oversight organizations and then further altered on a countryby-country basis. In emerging markets such as the UAE and China, government leaders have adopted some of the existing codes and standards from developed markets, including the U.S. and Europe, to advance fire protection. Closer examination of the standards that apply to pumps for fire protection shows the differences that exist among the predominant standards and underscores the importance of proper design and installation of fire pumps. These standards should be considered in the context of whole system performance and redundancy in fire safety systems to reduce the risk of death, injury and property damage. It s important to note that these various codes and standards on fire protection are not equal, interchangeable or enforceable by SDOs/ISDOs. Adoption of safety standards often is decided on a local level by officials who weigh cost of compliance with acceptable levels of risk. This is a complicated and subjective formula a balance among political, economic, business competition and other factors, and the value placed on safety and what is willing to be sacrificed for that safety. Key roles Other organizations, such as listing authorities like Underwriters Laboratories (UL), which governs electrical standards, and Factory Mutual Research Corporation (FM), a global insurer, influence building design and code development. These testing and certification organizations develop their own standards as well UL Standards cover fire pump controllers, fire pump motors and fire pump relief valves, and are important third-party certifications for manufacturers to obtain. Both UL and FM representatives sit on technical committees that review and develop standards, such as the NFPA Technical Committee on Fire Pumps. Further, in areas where local codes are weak or not enforced, listing authorities are sometimes regulators by default in cases in which their standards are more stringent. When the Standard for Installation of Stationary Pumps for Fire Protection known as NFPA 20, added multistage, multiport pumps as part of its 2016 update, it prompted FM to add multistage pumps to its FM 1311 standard for centrifugal fire pumps, improving safety in areas where FM regulations are the predominant standard. Manufacturers of fire protection equipment also play an important role in shaping technical regulations on fire protection. They can affect codes and standards in advisory roles as noted above and also through 3

the development of new products. Products with improved technologies, for example, can affect the operating procedures within fire protection systems or, if technology outpaces system capabilities, expose system vulnerabilities. For instance, NFPA s Technical Committee on Fire Pumps is considering the need for a common means to remotely access fire pump controller data; currently, each manufacturer has a proprietary means. Also, as construction practices evolve, codes become obsolete and refinements must be made to these living codes. In order to keep pace with these inevitable changes, American standards that fall under the auspices of the American National Standards Institute (ANSI) must be reviewed at least every five years NFPA updates codes every three years. CEN, the European Committee for Standardization, conducts a systematic five-year review of its standards. The European insurance federation known as CEA, updates its requirements every two to three years. During the interim periods, technical bulletins are issued as warranted. Pump standards Without question, the fire pump is one of the most critical pieces of equipment inside a building. The pump takes water from an external water supply, such as a public utility or reservoir, and provides the required water flow and pressure for the fire protection system. Reliable, code-compliant fire protection systems begin with the consulting engineer or designer, tasked with meeting the overall project objectives and selecting the necessary systems for the project. He or she must be knowledgeable in each component of the system and understand how each component will affect the selection of another component, and how they will all work together. The development of codified performance-based approaches to system design has begun to present designers with the necessary tools to better anticipate the building s performance in the event of a fire and a clear assessment of risks in terms of the overall project objectives. Standards governing fire pumps are most often included in broader guidelines for automatic sprinkler systems as the fire pump is a crucial part of the overall system. Some standards are loose guidelines for further code development; others that are more detailed and complex are designed to account for all conceivable scenarios in order to ensure maximum protection. Here is a summary of the leading standards and how they are applied: NFPA 20 The Standard for the Installation of Stationary Pumps for Fire Protection is the most widely recognized standard in the world, issued by the U.S.- based National Fire Protection Agency and prepared by NFPA s Technical Committee on Fire Pumps. The committee consists of more than two

dozen members and nearly two dozen alternates representing fire departments, fire equipment manufacturers, listing authorities, government, academia, engineering, insurers, associations, unions and other groups. NFPA 20 is considered the most stringent of all the leading codes with its many redundancies and safety measures. Unlike other standards, NFPA 20 addresses the entire fire pump room the pump, driver, controller, as well as water and fuel supplies, valves and other ancillary equipment necessary to ensure each of the individual components will perform as a whole if the system is activated. This is a critical distinction between NFPA 20 and other standards, which might simply require UL and FM (or similar) certified components and not take into account if those components will function properly together. (UL and FM certifications are fully compliant to NFPA 20.) In addition, NFPA 20 requires a single entity bear responsibility for all of the components in regard to installation, compatibility, performance and acceptance of equipment. FM specifies this be the pump manufacturer; UL does not specify the entity. NFPA standards are implemented internationally, advancing the development of standards for fire and life safety in many countries. Section 913 of the International Fire Code addresses the protection of the fire pump room within the building and defers to NFPA 20 for the installation and testing of fire pumps. In addition, NFPA has agreements called Memorandums of Understanding with standards-setting groups in more than a dozen countries, most recently adding the UAE in 2016. The primary purpose of each MOU is to promote the adoption of NFPA standards. BS EN 12845 In Europe, BS EN 12845 offers best-practice recommendations for the design, installation and maintenance of automatic sprinkler systems, and includes fire pumps. It is derived from EN 12845, developed by the European Committee for Standardization, known as CEN, which works with the standardization bodies of 33 European countries. The first EN (European Norm) sprinkler installation standard was issued in 2004 and revised in 2009 and 2015. Prior to that time, insurance companies in individual countries shaped fire protection rules. As countries add their own standards to the nonbinding EN 12845, the country standards supersede the EN code. British Standard (BS) is the United Kingdom implementation of EN 12845 and covers classification, routine testing, design, maintenance, water supply, extension, installation and special hazards related to sprinklers. The UK-based Fire Protection Association has developed Loss Prevention Council (LPC) Rules for Automatic Sprinkler Installation, which incorporates and supplements BS EN 12845. Changes in the 2015 edition related to fire pumps include greater specification on electric pump power supplies and pump curve stability. EN 12845 eliminates the requirement for stable pump curve with steadily declining head, but LPC has deemed this an important requirement and retained it in its 2015 standards. It s important to note that while fire pumps are included in these standards, the BS EN 12845 is not a pump standard and lacks the detail of NFPA 20, and also differs from LPCB, mentioned below. CEA 4001 The CEA is the European insurance and reinsurance federation. The CEA 4001 standard specifies requirements and recommendations for the design, installation and maintenance of fixed fire sprinkler systems in buildings and includes a chapter on pumps. CEA 4001 is based on EN 12845, with some updates and additional requirements. VdS, owned by the German Insurance Association, uses CEA 4001 as the basis for its standards relating to the planning and installation of sprinkler systems, known as VdS CEA 4001. The standard covers pumps, drives and controllers, but not as comprehensively as the NFPA 20 standard as it focuses on the individual components, and not the ethicacy of the system. LPCB Unlike BS EN 12845 and CEA 4001, the Loss Prevention Control Board (LPCB) issues a standard specifically for centrifugal pumps used in pump sets in automatic sprinkler installations. The LPCB 5

is the certification arm of BRE Global Ltd., based in the UK. It incorporates Loss Prevention Standards (LPS) for automatic sprinklers, BS EN 12845, LPC sprinkler rules and technical bulletins in its LPS 1131: Requirements and testing methods for pumps for automatic sprinkler installation pump sets. Included in LPS 1131 are definitions of the types of centrifugal pumps covered in the standard, however, it does not include requirements for the pump set driver or controller, a critical distinction between this standard and NFPA 20. Third-party certifications An important function of LPCB and VdS is to conduct third-party testing and certification internationally to ensure that components, equipment, systems and services comply with the standards for fire protection. In its testing, VdS Inspection Services also includes other standards, such as those produced by NFPA and FM. In its evaluation of products, LPCB considers the manufacturer s specifications for performance and construction. Once a product, service or company is certified by LPCB, it is listed in the Red Book, a resource for system designers and others involved in fire protection. Installers who receive third-party certification ensure that standards are met in designing and installing sprinkler systems for fire protection. Third-party certification is valuable for manufacturers because it demonstrates their products conform to recognized safety standards, reducing liability. In addition, system designers who specify certified products have confidence the products will perform in accordance with their stated specifications and intended purpose. The table at right provides a comparison of the consensus fire codes that reflect recent improvements and modifications in the field of fire protection. Conclusion By 2030, the world is projected to have 41 mega cities with more than 10 million inhabitants. Most of those places today are medium-sized cities and cities with less than 1 million people. Rapid urbanization will pose opportunities and challenges in every segment of society socially, politically, environmentally, economically including the built environment. As our world continues to grow in complexity, codes and standards that help shape our built environment will continue to evolve in order to protect health and safety for all. The codes of tomorrow will likely include things not even being contemplated today. Speaking at a 2016 symposium in the UAE, NFPA President and CEO Jim Pauley summed up the future of fire service with these remarks: There are new challenges, new technologies and new threats that warrant new thinking and new approaches. The once unimaginable is real, with real impact on fire and life safety. Brian Buscher is a global marketing manager for Xylem s A-C Fire brand with expertise in centrifugal pump systems for fire suppression in industrial and commercial facilities. He is a principal member of the NFPA 20 Technical Committee on Fire Pumps. Buscher holds a bachelor s degree from Northeastern Illinois University. Any comments/opinions made are the author s own and not those of NFPA. 6

REQUIREMENT NFPA 20 VDS CEA 4001 Unit responsibility Single entity is responsible for pump, driver, controller, transfer switch equipment, accessories; accountable to answer and resolve any and all problems regarding installation, compatibility, performance and acceptance of equipment Not specified LPCB: LPS 1131/ LPC RULES Suppliers of LPCB Approved Fire Pump Sets control and are responsible for design, construction, testing, performance, provision of installation instructions and commissioning of their fire pump sets; installer of approved fire pump set is responsible for the installation in strict accordance with manufacturer s installation manual and procedures BS EN 12845:2015 Not specified Pump room fire rating in high-rise buildings Protected from surrounding occupancies by a minimum of 2-hour fire-rated construction or physically separated from the protected building by a minimum of 50 feet (15.3 m) General pump room requirements: dedicated room; fire rating of 60 min Dedicated room; minimum requirement is to use a wall graded as FR60, but depending on risk, FR90 or FR120 may be recommended General pump room requirements: dedicated room; fire rating of 60 min Pressure relief valve allowed No; existing installations grandfathered Not specified Not specified Yes, unless restricted by local water authorities Multistage, multiport pumps Access to pump without disturbing suction discharge Yes Yes Yes Yes Yes Yes, no requirements Yes Yes, with allowable exceptions Remote controls Remote start/stopping is prohibited. (Annex) Two pressure switches shall be provided to start each pumpset, connected in series with normally closed contact Automatic starting enabled upon receipt of signal from pressure switches; shut down may only be done manually Automatic starting enabled upon receipt of signal from pressure switches; shut down may only be done manually Covers pump sets, controllers, drives, accessories Yes Yes Yes Yes Automatic transfer switches If authority requires one Two pressure switches shall be provided to start each pumpset, connected in series with normally closed contacts Main contactors shall be selected for utilization category AC3 according to IEC 60947 Low voltage switchgear and control gear Pressure switches will be connected in such a way that either switch will start the pump Maximum pressure limits Not to exceed pressure for which the system components are rated Not to exceed 12 bars Not to exceed rating on pump nameplate Not to exceed pressure for which the system components are rated 7

Xylem 1) The tissue in plants that brings water upward from the roots; 2) a leading global water technology company. We re a global team unified in a common purpose: creating advanced technology solutions to the world s water challenges. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. Our products and services move, treat, analyze, monitor and return water to the environment, in public utility, industrial, residential and commercial building services, and agricultural settings. With its October 2016 acquisition of Sensus, Xylem added smart metering, network technologies and advanced data analytics for water, gas and electric utilities to its portfolio of solutions. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise with a strong focus on developing comprehensive, sustainable solutions. For more information on how Xylem can help you, go to www.xylem.com Xylem Inc. 8200 N. Austin Avenue Morton Grove, Illinois 60053 Tel. (847) 966-3700 Fax (847) 965-8379 www.acfirepump.com Xylem Inc. 55 Royal Road, Guelph, Ontario N1H 1T1, Canada Tel. (519) 821-1900 Fax (519) 821-5316 A-C Fire Pump is a trademark of Xylem Inc. or one of its subsidiaries. 2017 Xylem, Inc.