Ramsey Motion Monitoring Systems

Similar documents
Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

SAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .

Operations Manual. Motion Detector Module Model ZS10

Process Protection. MFA 4P Motion Failure Alarm

T500 Elite - Hotbus Plant Wide Monitoring System for Bucket Elevators & Conveyors

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

DSD-3 DIFFERENTIAL SPEED DETECTOR

Belt Conveyor Safety Monitoring Devices

Frequently asked questions: Intelligent Transmitter Series

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Speed and Frequency Seite 1 von 7

ABB MEASUREMENT & ANALY TICS DATA SHEET. RS85 Vibrating fork level switch

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

OVEN INDUSTRIES, INC.

Watchdog Elite Watchdog Elite BRAIME Product Information Bucket Elevator & Conveyor Hazard Monitor

THERMAL MANAGEMENT SOLUTIONS

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Installation Instructions for W2H Series Signals

Software Version 2.01 LEVEL MONITOR MODEL 220

High Pressure Conductivity Monitor

THERMAL MANAGEMENT SOLUTIONS

Low-Cost, Non-Invasive, Microwave-Based Bulk Solids Flow Detector

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

OPERATION MANUAL Part No. MIL8001V4C

Centro-Matic Automated Lubrication Systems System Controls

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

Pioneer-R16 Gas Monitor Operator s Manual

Ultrasonic Point Level Switches

FDF Foam Pump Controllers Features

Pump-Down Controller MODEL 4052

B-40/B-41 Modulating Temperature Controller

vibration switch

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Retro-reflective Sensing range: 0mm to 2000mm

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Commercial and Light Industrial Fire Alarm Control Panel

SEC 2000 Millenium Infrared Gas Detector

Solid State Relays SOLITRON MIDI Current Sensing Type RJCS, RJCSR

Ultrasonic Switches. Features & Benefits

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

OPERATION MANUAL Part No s. P8003V10C, P8004V10C

7800 SERIES RM7888A Relay Module

SAFETY INFORMATION AND WARNINGS

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

H&O DIE SUPPLY, INC SPR-2000-JR. Programmable Fluid Controller Interstate 20 Kennedale, TX 76060

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

Tachometer/Hourmeter/Trip. Installation and Operation Manual

Model Q45P/R. ph/orp Monitor...

ProxView Programming Software. iprox Inductive Sensors iprox Programming Tools. iprox Sensors. iprox. The world s most versatile proximity sensor.

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Power Transfer Devices. Access Control Accessories. How To Order. How to Order

Oxygen (O2) Single-Point Gas Detection System

Catalog Number E57 product family or iprox. Description Tubular inductive proximity sensor

Pump-Up Controller MODEL 4062

Nov 08 PRODUCT SPECIFICATION SHEET

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

5.0. Photoelectric Sensors. Technical Reference. Introduction

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

MINI-BEAM Expert Series

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

Model Q45P/R. ph/orp Monitor...

Sentry G3 Machinery Protection Monitor

ISIS SAFETY SYSTEM Installation guide

Power Supply Display Module PSDM. Installation and Operation Manual

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

DIESEL Engine Fire Pump Controllers Features

INSTRUCTION MANUAL MODEL LDE 740. (Revised July 8, 2017)

Sierra Series 900 Single & Dual Channel System. Instruction Manual

SECTION LOW VOLTAGE LIGHTING CONTROLS

Is your process protected?

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

User and Service Manual

Model 4001 Series Single Channel Controller

Instruction Manual August sitrans CU 02

Ultrasonic Proximity Sensor

Analog Room Pressure Monitor RPC Series

INTRODUCTION / TABLE OF CONTENTS

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

Two-Channel Gas Controller

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

NGC-40 Advanced Heat-Tracing Control System

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

Transcription:

Ramsey Motion Monitoring Systems 60-200 Motion Monitoring Accurate Sensing of Underspeed, Overspeed and Zero Speed Conditions on Rotating Shafts and Machinery The Ramsey Series 60-200 Motion Monitoring Systems offer a choice of versatile and reliable packages for monitoring underspeed, overspeed and zero speed conditions on various machinery and systems by sensing the speed variations of rotating parts. Customers can choose from either mechanically coupled (shaft-driven) or non-contacting proximity type sensors, depending on their particular application requirements and design preferences. Either type of sensor can then be tied to the 60-200 programmable motion monitor. This unique control package is housed in a separate NEMA 4X enclosure and can be mounted near the sensing component or, for convenience and accessibility, up to 1000 feet from the sensor. Optional signal amplification accessories can increase that distance even further.

Ramsey Model 60-24 Motion Sensor The Model 60-24 systems incorporate a direct coupled shaft-driven sensor for measurement of shaft rotation. System selection allows for the choice of a single or dual channel monitor, high speed (up to 2000 RPM) or low speed (up to 50 RPM) sensor. The very low speed system is capable of very sensitive operation at very low shaft speeds (less than 0.025 RPM). All systems include conduit type connector and 5 foot lead wire. 60-24 sensors are suitable for Class II hazardous areas. If used in a Class I hazardous area, an intrinsic safety barrier must be incorporated in signal leads. The 60-200 monitor must always be located in a non-hazardous area. Options for the 60-24 systems include two types of mounting hardware and intrinsic safety barriers. Options: The following options are regularly available for 60-24 systems. If ordering options, they should be designed by adding suffix letter(s) to the system model number. (Example: High speed system with single channel monitor and optional rigid mounting hardware is designed by model number 60-24H-I-R). (-F) Flexible mounting strap with rigid coupling hardware suitable for shaft speeds up to 200 RPM (-I) 4 20 ma or 0 20 ma output (-R) Rigid mounting brackets for sensor with flexible shaft coupling. Recommended for shaft speeds in excess of 200 RPM to decrease sensor vibration. (-X) Intrinsic safety barrier to allow mounting sensor in hazardous Class I or II, Division 1 area (-VL) Optional for setpoints to 0.025 RPM (-SL) Optional for setpoints to 0.0125 RPM PROGRAMMABLE FEATURES Reference Speed Display Speed Learned by operator pressing and holding Select key for five seconds At touch of key, current speed is displayed as a percentage of reference Alarm Adjustment 0 to 160% of reference speed, in 1% increments, subject to minimum alarm setpoints shown with various models above. Dual channel model has two separately adjustable alarm points. Channels may be set for underspeed and/or overspeed. Start-up Delay Alarm Delay Reset Mode Start Conditions Alarm Clear GENERAL SPECIFICATIONS Power on/remote reset or PLC control Power on or detection of pulses Automatic or manual (latched) reset. Various error messages are also generated via the LED display to alert user of programming errors or system faults. Programming instructions are stored in permanent memory and will be retrieved when power is applied. Voltage 115VAC 60HZ or 230VAC 50HZ +/- 10% Note: The dual channel 60-200-2 model (only) has a power transformer that is adaptable to other voltages and frequency power supplies that are found outside of the USA. GENERAL SPECIFICATIONS cont. Outputs Sensor Input Operating Ranges SENSOR SPECIFICATIONS Supply Voltage Output Electrical Connection Operating Temperature Dimensions Model 60-200-1: Single channel, one adjustable output. (1) DPDT 230VAC/5A Non-Inductive 2 Amp Inductive Relay (NC/NO Selectable). Model 60-200-2: Dual Channel, two independently adjustable outputs. (2) DPDT 230VAC/5A Non-Inductive 2 Amp Inductive Relay (NC/NO Selectable). Both models have 0 to 2 VDC output or an optional 4 20mA signal available, proportional to rotational speed of monitored device. 1VDC equals reference speed (100%). NPN (up to 3KHZ), PNP*, or dry contact.* *60-200-2 only. 60-24H System: up to 2000 RPM Minimum alarm setpoint = 1.25 RPM 60-24L System: up to 50 RPM Minimum alarm setpoint = 0.1 RPM 60-24VL System: up to 10 RPM Minimum alarm setpoint = 0.025 RPM 12VDC from 60-200 monitor Open collector NPN 100 ma current sinking Furnished with 1/2 NPT conduit fitting and 5 feet 22 AWG leads with butt splices -40 C to + 85 C See drawings Operating Temperature Enclosure 60-200-1: -40 C to +50 C 60-200-2: -40 C to +85 C Noryl GFN3 (NEMA 4X), See drawing for dimensions. Sensor Housing Mounting Hardware Polished aluminum Furnished as option only. Can supply flexible strap with rigid coupling, recommended for speeds up to 200 RPM, or rigid mounting bracket with flexible coupling, recommended for shaft speeds in excess of 200 RPM. See Options.

Ramsey Model 60-22 Motion Sensor The Model 60-22 systems incorporate a non-contacting proximity type sensor for measurement of shaft rotation. System selection allows for the choice of a single or dual channel monitor, high speed (up to 5000 RPM) or low speed (up to 50 RPM) sensor. The sensor includes a LED that indicates pulse output. This feature simplifies system installation for correct gap setting and troubleshooting. All systems include 20 feet of lead wire and a sensing mounting bracket. Low speed systems include 30 segment target disc and mounting kit. 60-22 sensors may be mounted in Class I or II, Division 2, hazardous areas if wiring is run in approved conduit. For use in Class I or II, Division 1 areas, an intrinsic safety barrier must be incorporated in signal leads. The 60-200 monitor must always be located in a non-hazardous area. Options for the 60-22 systems include a stainless sensor, intrinsic safety barriers, conduit connectors long range sensors, and several target options with hardware. Options: The following options are regularly available for 60-22 systems. If ordering options, they should be designated by adding suffix letter(s) to the system model number. (Example: High speed system with single channel monitor and optional 3 pulse target designated by model number 60-22H-l-T). (-H) Hose clamp hardware with insulator for simple target on side of rotating shafts (-T) Three pulse target for slower speed applications of 60-22H system. Alarm range approximately 4 to 50 RPM. (-X) Intrinsic safety barrier to allow mounting sensor in hazardous Class I or II, Division 1 area (-Z) Conduit connector, metric to english. Hazardous area mounting requires running cable in conduit. PROGRAMMABLE FEATURES Reference Speed Display Speed Learned by operator pressing and holding Select key for five seconds At touch of key, current speed is displayed as a percentage of reference Alarm Adjustment 0 to 160% of reference speed, in 1% increments, subject to minimum alarm setpoints shown with various models above. Dual channel model has two separately adjustable alarm points. Channels may be set for underspeed and/or overspeed. Start-up Delay GENERAL SPECIFICATIONS cont. Outputs Model 60-200-1: Single channel, one adjustable output. (1) DPDT 220VAC/5A Non-Inductive 2 Amp Inductive Relay (NC/NO Selectable). Model 60-200-2: Dual Channel, two independently adjustable outputs. (2) DPDT 220VAC/5A Non-Inductive 2 Amp Inductive Relay (NC/NO Selectable). Both models have 0 to 2 VDC output or an optional 0 20, 4 20 ma signal available, proportional to rotational speed of monitored device. Alarm Delay Reset Mode Start Conditions Alarm Clear GENERAL SPECIFICATIONS Power on/remote reset or PLC control Power on or detection of pulses Automatic or manual (latched) reset. Various error messages are also generated via the LED display to alert user of programming errors or system faults. Programming instructions are stored in permanent memory and will be retrieved when power is applied. Sensor Input Operating Ranges SENSOR SPECIFICATIONS Supply Voltage Nominal Sensor to target Range NPN (up to 3KHZ), PNP*, or dry contact*. *60-200-2 only. 60-22H System: up to 5000 RPM Minimum alarm setpoint = 12 RPM 60-22L System: up to 50 RPM Minimum alarm setpoint = 0.4 RPM 12VDC from 60-200 monitor 60-22H Sensor (30mm dia.): 0.394 inches/10mm 60-22L Sensor (12mm Dia.): 0.197 inches/5mm Voltage 115VAC 60HZ or 230VAC 50HZ +/- 10% Dimensions See drawings Note: The dual channel 60-200-2 model (only) has a power transformer that is adaptable to other voltages and frequency power supplies that are found outside of the USA. Detection Indicator Cable LED lights when iron target in range of sensor. Helpful in adjusting sensor position and for troubleshooting sensor or wiring failures. 3 wire, oil resistant thermoplastic, 20 ft standard Operating Temperature Enclosure 60-200-1: -40 C to +50 C 60-200-2: -40 C to +85 C Noryl GFN3 (NEMA 4X), See drawing for dimensions. Sensor Material Bracket Material Threaded barrel is chrome plated brass, plastic face is PA12-GF3. Metric threads. Chrome plated brass

Ramsey Model 60-200 Control Model 60-200 Control The 60-200 programmable motion monitor is a versatile microprocessor-based controller that can be used with any Ramsey sensors, or in some cases, as the control device matched with compatible pulse output sensors from other sources. All alarm functions, delays and operating parameters are entered via a simple three-button keyboard. There are no potentiometers to adjust. A four digit, seven segment display will show the current speed as a percentage relative to a userprogrammed reference speed. It also is used to display various parameters and set-up values when the control is in its set-up mode. Finally, the display will show an error code if any problems occur. This helps the operator to troubleshoot any system failures. Detailed programming instructions are contained in the system manual and a quick reference programming guide is displayed on a label on the inside of the control s enclosure cover. One or two DPDT outputs are available from the 60-200 (depending on whether the single or dual channel model is used) for output of monitored conditions to remote alarm displays or control functions. Also available is a 0 to 2VDC output or optional 0-20 ma, 4-20 ma signal proportional to the rotational speed of the shaft being monitored. one output can be set for overspeed and one for underspeed, or both for overspeed or underspeed. (For example: Set both outputs at underspeed, one at 90% for alarm and one at 80% for shutdown). Other programmable set-up features include start-up delay, alarm delay, restart mode, how start-up delay is initiated, and whether the alarm condition must be manually reset (latched) or will reset automatically upon termination of alarm condition. PROGRAMMABLE FEATURES Start-up Delay 0 to 99 Seconds Alarm Setpoint(s) 0 to 160% Alarm Delay Reset Mode Begin Start-up Delay 0 to 99 Seconds Power on, Remote Relay Input Power up, First Pulse Alarms can be set at 1% increments over a range of 0 to 160% of reference speed. With the dual channel 60-200-2 models, Alarm Clear Manual (Latched), Automatic http://www.thermoramsey.com

Specifications 60-200 Motion Monitor 60-22 Non-Contacting 3 3/4 6 1/4 4 1/2 5 3/8 3 1/2 2 1/4 4 3/8 1 1/2 7.925 Sennsor Mouning Brackets 60-24 Direct Couple 5 3 1/4 2 3 1/8 M12x1 LED 1.181 4 1/2.472 Dia. 2.008 2 1/2.394 12MM Sensor 1/2 NPT 3/8 1 3/4 60-24 Direct Coupled Sensor LED M30x1.5.591 1.181 Dia. M12x1 1 3/4.472 Dia 1.575 2.480 2 7/8.394 30MM Sensor 3 1 3/8 Mounting Bracket

Typical Applications 60-24 Direct Coupled Sensors 60-22 Non-Contacting Sensors Catalog No. 20.620 (Rev. 10/02) Printed in U.S.A. SP 501 90th Avenue N.W. Minneapolis, MN 55433 Tel: (763) 783-2500 FAX: (763) 783-2525 http://www.thermoramsey.com