LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

Similar documents
LD920. User Manual. H2/N2 Tracer Gas Leak Detector. Detects 5% H2 in 95% Nitrogen Tracer Gas. Made in U.S.A. LeakDetectors-LD920-UserManual.

LD900. User Manual. Refrigerant Gas Leak Detector. Detects all HFO, HFC, HCFC, and CFC Refrigerants including blends. Made in U.S.A.

99 Washington Street Melrose, MA Phone Toll Free Visit us at

ATD-3698 Refrigerant Gas Leak Detector. Owner s Manual

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

LD-5000 REFRIGERANT LEAK DETECTOR

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

LD 5000 REFRIGERANT LEAK DETECTOR JB INDUSTRIES INC.

Operating Instructions. Model: LD3 Dual Mode Refrigerant Gas Leak Detector ROBINAIR.COM

Model: LD7 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

NGD8800 USER S MANUAL

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

Combustible Gas Leak Detector Instruction Manual

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

CD100A COMBUSTIBLE GAS DETECTOR

GAS-Mate. Combustible Gas Leak Detector

Instruction Manual MSI Sensit HXG

Combustible Gas Leak Detector Instruction Manual

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

YELLOW JACKET. ACCUPROBE UV and ACCUPROBE II Refrigerant Leak Detector with Heated Sensor. Instruction and Operation Manual

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

SENSIT HXG-2d Combustible Gas Detector

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

Model 850 Investigator s Aid Accelerant and Gas Detector Operation and Maintenance

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

Refrigerant Leak Detector

SBS-H2 Hydrogen Gas Detector Kit

LS1. Operator Manual. Kane International Ltd

Model C Electronic Nose Accelerant and Gas Detector Operation and Maintenance

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

Model LP USER S MANUAL AND INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL CD Fax: (503)

COMBUSTIBLE GAS LEAK DETECTOR PEN

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

Model GP-01 Combustible Gas Monitor Operator s Manual

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Famous Trails Anaheim, California

Installation and Wiring 1.

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

INSTRUCTION MANUAL GAS LEAK DETECTOR CD200

SP-220. Features. Combustible handheld gas leakage detector

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Model 950-ASH Arson Scanner Hydrocarbons and Accelerants Detector Operation and Maintenance

Combustible Gas Detection and Control System

Model GX-2003 Operator s Manual

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

testo 316-EX gas leak detector Instruction manual

Electron Microscopy Sciences

ESD500. ESD500 Combustible / Toxic Gas Detector

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

ESD3000 ESD200 Combustible / Toxic Gas Detector

REFRIGERANT LEAK DETECTOR OPERATIONS MANUAL LD-170

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

REFRIGERANT LEAK DETECTOR

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Model C Combustible Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

OPERATING INSTRUCTIONS

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

EVac II Programmable Digital Vacuum Gauge

MICROpeL 75 Combustible Gas Sensor Part Number: PM

SENSIT PROPANE GAS. 4Gas Leak Detectors 4Hazardous Gas Monitors 4Calibration Stations 4Data Management 4Pipe Locators ENERGY INDUSTRIES

GX-2009 MSHA Certified Version CH 4 /O 2 /CO/H 2 S Portable Gas Monitor Operator s Manual

03 Series: GP-03 Version Operator s Manual

Model GX-2001 Canadian Version Operator s Manual Part Number: RK Revision: 0 Released: 1/17/05

Operator's Manual. LIGHTNING 2 Laser Detector

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

APPLICATION DATA SHEET

Restek s Electronic Leak Detector

User Manual. GPD 3000 e. gas detector

Model GX Operator s Manual

NEW Restek Electronic Leak Detector

SENSIT FIRE SERVICE. 4Hazardous Gas Monitors 4Gas Leak Detectors 4Calibration Stations 4Data Management EMERGENCY RESPONSE

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

ALTAIR 5X Multigas Detector Product Specification

Explosion protection Marijan Gorše, dipl. ing.

GAS ANALYSIS / DETECTION Gas Detector

Portable Combustible Gas Detector GP-1000 Operating Manual (PT0-120)

G450. Multi-gas Detector. Field Operation Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

GX-2009 Portable Gas Monitor Operator s Manual

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

WARNING Important Safety Information

Smoke Alarm User s Manual

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

WATER BATH BM100 BM200

Installation & User Manual

TM-802 Formaldehyde Meter User s Manual

GX-2009 Portable Gas Monitor Operator s Manual

Instruction Manual Eagle Series

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Transcription:

LD910 Combustible Gas Leak Detector Detects all Hydrocarbon and other Combustible Gases User Manual MSHA Approved Intrinsic Safety Made in U.S.A. LeakDetectors-LD910-UserManual.indd 1

INTRODUCTION The LD910 features a long life heated sensor technology that is designed to detect all combustible gases including Methane, Propane, Butane, Acetylene, Alcohol, and Gasoline. Our unique digital leak size indicator takes the guesswork out of whether to repair a small leak. The digital display is independent from the audio alarm and sensitivity level, allowing the precise pinpointing of the leak source. The LD910 does not require rechargeable batteries. FEATURES Unique numeric leak size indicator Long life, stable sensor Methane sensitivity <5 ppm Automatic calibration and reset to ambient Low battery indicator 3 adjustable sensitivity levels Audio mute function Uses 4 AA alkaline batteries Intrinsically Safe Certified Comfortable Sanoprene grip CE Certified 2-year warranty includes sensor Made in USA 2 LeakDetectors-LD910-UserManual.indd 2

LD910 CONTROL PANEL Digital Leak Size Indicator Low Battery Indicator Sensitivity Level Indicators Audio Mute & Sensitivity Level Selectors Power On/Off OPERATING INSTRUCTIONS 1. TURN ON: Press the ON/OFF button once to turn on and again to turn off. 2. WARM UP: The detector automatically starts heating the sensor. During the heating cycle, the digital leak size indicator will flash 0 and the detector will sound a slow beep. Warm up time is usually less than 20 seconds. 3. READY: The detector is ready to begin searching for leaks when the flashing 0 stops and the green sensitivity LED turns on. The audio beep increases in frequency and probe LED begins to blink steadily. 3 LeakDetectors-LD910-UserManual.indd 3

LEAK SIZE INDICATOR The digital leak size indicator remains off normally but once a leak is detected, a number from 1-9 will be displayed for all combustible gases regardless of the sensitivity setting. The number will continue to increase or decrease depending on the amount of combustible gas sensed. The maximum value will be displayed once the leak source has been located. LOW BATTERY INDICATOR Replace the 4 AA Alkaline batteries when the red LED on the control panel is lit. Follow battery installation instructions under Maintenance section. AUDIO MUTE FUNCTION To silence or mute the audio beep and alarm signal, press the MUTE button. To restore the audio sound, press the MUTE button again. (Note: a few seconds is required to restore sound if the mute button is pressed in rapid succession.) 4 LeakDetectors-LD910-UserManual.indd 4

ADJUSTING SENSITIVITY LEVELS The Leak Detector will default to the NORM sensitivity level automatically once the unit comes out of the warm up cycle and the green LED will turn on. To change sensitivity levels, press the SENS once for HI sensitivity (red LED will turn on) and again for LO sensitivity (yellow LED will turn on). LEAK TEST VIAL The leak detector comes with a Leak Test Vial that allows the user to make sure the detector is performing properly. To test: 1. Remove the colored label dot in the center of the screw cap to expose the vent hole in the top of the screw cap. (see fig. below). 2. Turn on the leak detector and allow the instrument to complete the warm up cycle. 3. Place the sensor close to the small hole in the top of the Leak Test Vial. The beep rate should increase and the Digital Leak Size Indicator should display a number from 3-6 indicating that the sensor and the electronics are working properly. Remove label dot over vent hole before testing Vial cap with vent hole Expiration date on label NOTE: Replace the Test Vial back in the nylon bag when not in use to extend the shelf life. Replace Test Vial when the green color is less than ¼ full or at the time of the expiration date. 5 LeakDetectors-LD910-UserManual.indd 5

BATTERY MAINTENANCE Install Batteries: Remove screw located at rear end of unit and pull down hinged battery door to open as shown. Always insert all four batteries into the battery compartment in the same direction. Note: polarity mark on the inside of the battery door for proper battery orientation. Polarity mark SENSOR MAINTENANCE Replace Sensor: Remove sensor by unscrewing sensor cover. Install the new sensor by aligning the notch in sensor socket with the raised tab on socket holder (see figure below). Note: Do not force sensor into socket. Misalignment can damage the sensor pins. Unscrew cover to replace sensor Pull straight on (do not twist) to install sensor 4 pin sensor Alignment key Sensor socket tab Flex probe 6 LeakDetectors-LD910-UserManual.indd 6

PRODUCT SPECIFICATIONS Model # LD910 Name Sensitivity Sensor Life Response Time Power Supply Battery Life Warm up time Probe length Leak Detector, Combustible Gas <5 ppm Methane > 300 hours Instantaneous 4 AA Alkaline batteries 20 hours continuous < 10 seconds 17 inches (43.8cm) Numerical Display 7 segment digital display (1 to 9) Weight, lbs. Warranty 1.5 lbs. (0.68kg) 2 years (includes sensor) PARTIAL LIST OF DETECTABLE GASES Methane Ethane Hydrogen Ethanol NOL Acetylene Ammonia Industrial Solvents Alcohols Toluene Propane Butane Ethylene Iso-butane Gasoline Methyl Ether H. Sulfide Benzene Acetone Xylene 7 LeakDetectors-LD910-UserManual.indd 7

REPLACEMENT PARTS Item Combustible Sensor Sensor Cover Leak Test Vial Carrying Case Part Number S77700 S77701 S77702 S77703 WARRANTY The LD910 Combustible Gas Leak Detector is warranted to be free of defects in materials and workmanship for a period of two years from the date of purchase. This warranty applies to all repairable instruments that have not been tampered with or damaged through improper use including unauthorized opening of the unit. Tools should be returned to the buyer s place of purchase. SERVICE/TECHNICAL QUESTIONS CALL TOLL FREE: 888.467.8665 www.imperial-tools.com info@stridetool.com 30333 Emerald Valley Pkwy. Glenwillow, Ohio 44139 888.467.8665 LeakDetectors-LD910-UserManual.indd 1