Setup instructions. Honeywell GAS DETECTOR. Overview. Accessories The instruction x1 Plug dowel x2 Screw x2 Double-sided adhesive tape x2

Similar documents
Honeywell Smokr detector. Overview. Accessories

Mijia Air Purifier Pro

WCD-200W Water Dispenser

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

EXPLOSION-COUNTERACTING SYSTEM «UDAR-KB» Installation Guide

NG-9B NATURAL GAS ALARM

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

1. Safety instructions Mounting location in rooms of the heat detectors... 3

Operating instructions for the radio heat detector GS412

WCD-210BK. Water Dispenser OWNERS MANUAL. Read and save these instructions.

GSM RFID VOICE Alarm System

KAE Gas Alarm Operation Manual

MOBILE CALL GSM Alarm System User s Manual

Water Filter. cover. start button. reminder of cartridge replacement. remainder of life of a cartridge it is time to replace a cartridge

Instruction Manual MSI Sensit HXG

Supplement to operating and installation manual no for the VR 81 remote control unit

CENTRIFUGAL FANS user's manual. model VENTS VK.

02 Setting. 03 Usage

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

RK / RK Methane Detector Operator s Manual

KAB Gas Alarm Operation Manual

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

Installation manual Mini Comfort 50 S/L 07/ V EN

Axial intelligent fan USER S MANUAL

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

Operating Instructions

ELECTRONIC GUN SAFE USER MANUAL. Models: SLSFE61GN - SLSFE63GN

Read these instructions before using and keep them available at all times!

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

E1000 Portable gas detector

Cooker Hood LA-72-CAN.

RK/ RK Combustible Gas Detector Operator s Manual

Operating Instructions

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

USERS MANUAL FOR GAS BOILERS

User s Guide for the SunDanzer BFRV55

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

Components of the device. Appearance of the device. ihealth thermometer User s manual LED screen. Manufacturer info. LED screen.

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

QD6310. Fixed Gas Detector Operation Manual

User Manual. 110 Cup (55 Cup Raw) Gas Rice Cooker. Model: 177GRCLP, 177GRCNAT 12/2018. Please read and keep these instructions. Indoor use only.

Operating instructions

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

Gas Instantaneous Water Heater

GT-1D. Residential/Tenant Station OPERATION MANUAL

BEP Marine Gas Detector FD-2

2-IN-1 UPRIGHT HANDHELD VACUUM CLEANER INSTRUCTION MANUAL

USER MANUAL. FairWind FWPC6L Pressure Cooker. Contact Us:

Operation Manual for Drying Storage Cabinet with Drying Unit U-5002

BEVERAGE COOLER. 3.2 Cubic Feet. Before using your Beverage Cooler, please read this manual.

SOME NOTIONS ON HUMIDITY

Photoelectric Smoke Alarm

COMBUSTIBLE GAS LEAK DETECTOR PEN

Convection Panel Heater

MINI ELECTRIC CONVECTION HEATER

IMR EX610. Portable Gas Detector. Operation Manual

Models: RP-10, RP-15, RP-20. User Manual

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Portable Ceramic Space Heater

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

INSTALLATION INSTRUCTIONS

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

INSTRUCTION MANUAL PC255O

Instructions for use

Read these instructions before using and keep them available at all times!

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

AIR CONDITIONER. Please read this owner, s manual carefully before using the air conditioner, and keep this manual for the future reference.

Air handling unit. BlauAir RH USER S MANUAL

LISEO Insert. European Standard Certification UNE EN inserts. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

Portable Room Air Conditioner and Heat Pump

VL-50S2-E (pull cord Type) VL-50ES2-E (wall switch Type)

INSTRUCTIONS AND WARRANTY

INSTRUCTION MANUAL PC255O

1500W STOVE HEATER INSTRUCTION MANUAL. Item No: 050-HA-50090

USER S GUIDE SPARE PARTS SPARE PARTS FOR SOS-LIFE EARTHQUAKE/EMERGENCY ALARM. SOS-LIFE earthquake/emergency alarm unit

Beacon 800 Gas Monitor Operator s Manual

INFRARED ZONE HEATING SYSTEM

GAS-Mate. Combustible Gas Leak Detector

36 WALL MOUNTED FIREPLACE

IMR IX176 Portable Gas Detector User Manual

User manual. Always there to help you. Question? Contact Philips AC3252 AC3254 AC3256

microcut sheet capacity user manual 7.8 gal. basket commercial shredder GMC225Pi PLATINUM SERIES

RK Combustible Gas Transmitter Operator s Manual

Read these instructions before using and keep them available at all times!

AIR HANDLING UNIT WITH HEAT RECOVERY

Dual Spin Mop Robot Cleaner

User Manual. Ceramic Cooktop Model : CRSF745

LISEO STOVES. European Standard Certification UNE EN stoves. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

ELECTRIC ASHCAN MODEL NO: ASHVAC1200 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

OWNERS INSTRUCTION MANUAL

User`s Manual. Using the device The basic diagram of product

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Operating instructions

BEP Marine Gas Detector 600-GDRV

Portable Space Ceramic Heater

IMPORTANT SAFETY INSTRUCTIONS

Transcription:

Setup instructions 1. Connection terminal, output signal and device connection Honeywell GAS DETECTOR Overview The autonomous gas sensor (hereinafter referred to as the sensor) is a home device for detecting a leak of natural gas (the main component is methane), which, in the case of determining a high concentration of combustible gas (methane) in the room, produces a light-sound alarm or sends a warning message to the connected device. Alarm x1 Mounting plate x1 Battery x1 Accessories The instruction x1 Plug dowel x2 Screw x2 Double-sided adhesive tape x2 * Even if the connection terminal is not connected to the device, the sensor will still function. * If you need to connect an electromagnetic solenoid valve or an output fan to the wiring, please ask your dealer for assistance. Сonnection terminal Holes for sound «Sound/Self control» button Holes for detecting a gas

Installation the mounting plate to the ceiling; d) Attach the main alarm panel to the mounting panel in accordance with all the reference marks, go clockwise until you hear a characteristic click that indicates the fixation of the device. 1. Fastening with screws a) Insert the battery into the battery compartment, press and hold the «Sound / Self-check» button for 1 second. Make sure that the red-yellow indicator starts flashing on the device, after which you will hear a corresponding beep. b) Drill holes in the ceiling with a perforator; c) Insert the dowels; d) Using self-tapping screws, attach the mounting plate; e) Attach the main alarm panel to the mounting panel in accordance with all the index marks, go clockwise until you hear a characteristic click that indicates the fixation of the device. Using self-tapping screws, install the mounting plate. Attach the main alarm panel to the mounting panel in accordance with all the indicia. Turn clockwise until it clicks. 2. Mounting with adhesive tape a) Insert the battery into the battery compartment, press and hold the «Sound / Self-check» button for 1 second. Make sure that the red-yellow indicator starts flashing on the device, after which you will hear a corresponding sound signal b) Remove the protective film from one side of the adhesive tape and attach it to the back of the mounting panel; c) Remove the protective film from the other side of the adhesive tape and attach Precautions for installation a. Install the device in the premises where the gas (methane) is conducted; b. Avoid places outside the premises; c. Avoid rooms with a temperature below -10 C or above 55 C; d. Avoid places near other devices, that produce hot air, water vapor or soot (for example, directly above the gas stove); e. There should be no barrier between the sensor and the gas equipment, otherwise the sensor will not be able to measure the gas concentration level; f. Avoid places at the hood, windows, entrance doors and other well-ventilated places, otherwise the sensor will not have contact with the gas and will not be able to measure its concentration level; g. Make sure all sockets are plugged in; h. It is recommended to perform the installation with screws, in the case of installation with adhesive tape, unforeseen situations may occur, the user is responsible for; i. If installed with adhesive tape, make sure that the selected surface for attaching the device is smooth, smooth, clean and dry; j. If installed with adhesive tape, it is necessary to regularly check the reliability of the fastening to prevent the sensor from falling.

Selecting an installation location Wall mounting: the distance between the gas sensor and the gas equipment or valve should not be more than 4 meters, the distance from the sensor installation to the ceiling should be less than 0.3 meters, but do not install the sensor directly above the gas equipment. Below is a schematic drawing that will help you choose the right location for the device. Indicator status Functions Ceiling installation The distance between the gas sensor and the gas equipment or valve should not be more than 4 meters, do not install the sensor directly above the gas equipment. Below is a schematic drawing that will help you choose the right location for the device. 1. Power supply for preheating Using Before switching on the power, make sure that the power source is operating properly; Connect the device to the power supply - the buzzer sounds three times, after which the red, yellow, green indicator flashes in turn. After about five minutes, one long beep will sound, indicating the exit from the preheating mode, the green indicator will light up. * When using for the first time, or if the device has not been used for a long time, please connect the sensor to the power supply for 72 hours for further optimal operation of the device. 2. Normal working status In the absence of malfunctions or an alarm, the green indicator is constantly on; when the «Sound / Self-diagnosis» button is pressed, the sensor switches to the self-test mode (once in a row the red, yellow, green indicator flashes, and the alarm sounds once). After completion of self-diagnosis, the sensor restores normal

operation. Main parameters 3. Alarm If the device has no faults, but as a result of exceeding the permissible level of gas concentration in the room, the audible alarm turns on, the red indicator lights up, and the signal sounds. To turn off the signal, press the «Sound / Self-Diagnosis» button, and after about 70 seconds the device will resume its operation. If the gas concentration level is below the maximum permissible value of the sensor, it automatically switches to normal operation. If other devices are connected to the sensor, it is necessary to confirm the elimination of a hazardous situation and restore the gas supply. Reconnect the devices according to the recommendations in the operating instructions. 4. Fault status In case of a malfunction, the yellow indicator lights up and a beep sounds, and two beeps sound every 5 seconds. You can press the «Sound / Self-Diagnosis» button, after 12 hours the audible alarm will turn on again. 5. Duplicate a signal on another device If the sensor is operating in normal mode, press and hold the «Sound / Self- Diagnosis» button for 3 seconds to enter the signal duplication mode. In this case, the red indicator will light up, a continuous loud beep will turn on. If you press and hold the «Sound / Self-Diagnosis» button for 11 seconds, an alarm is output to the connected device. If you release the button, you immediately exit the signal duplication mode. Maintenance To ensure normal operation of the sensor, perform maintenance on the device following the following recommendations: 1. Install, use and maintain the sensor, following the recommendations in the manual; 2. It is recommended to perform a self-diagnosis of the device once a month: press the «Sound / Self-diagnosis» button, make sure that the sensor is functioning normally; 3. It is recommended to wipe the external surface of the device every season, clean the air intake openings from dust and grease, make sure that the sensor holes have good entrance patency, and the alarm system works properly. To clean the device use a dry towel, do not use alcohol, chemical, other abrasives or too wet a towel. 4. It is recommended to calibrate once a year. Calibration should be performed by qualified organizations. Do not perform a calibration yourself.

Cautions Faults and troubleshooting 1. This sensor is used only for pipeline gas (methane), can not be used to determine liquefied gas in cylinders; 2. It is forbidden to make changes of the internal structure of the device; 3. Do not directly expose the highly concentrated flammable gas to the sensor (eg lighter gas, clean natural gas, etc.), this may result in a partial / total reduction in the sensitivity of the sensor or its damage; 4. Avoid a large number of solid aerosols, insecticides, paints, glues, solvents and other similar substances near the sensor. This can provoke a false alarm and adversely affect the life of the device; 5. The operating life of the internal sensor is 5 years. Please pay attention to the service life of the device and perform timely maintenance or replacement of necessary elements; 6. Regularly pay attention to the work of the sensor. In case of a malfunction, do not disassemble the device yourself. It is necessary to contact the store or the manufacturer in a timely manner and describe in detail the signs of the problem so that the after-sales service representative can advise you. If the product needs to be returned to the factory for maintenance, adhere to the safety practices when using gas. Rights and responsibilities of the company 1. This manual contains a detailed description of the rules for using the device, its technical parameters and other information, but the company reserves the right to make changes to the manual without further notice; 2. The shown sensor may be slightly different from the actual device, the actual appearance of the product prevails; 3. This information is intended only for familiarization, it is not a form of obligation; 4. All rights reserved, the company reserves all rights. No part of this manual may be reproduced in full or in part, copied by any organization or person without prior written consent and should not be distributed in any form.

Actions on gas leakage 1. When the alarm is on, do not turn on any electrical appliances; 2. It is forbidden to disconnect the sensor from the power source, it can automatically close the solenoid valve and turn on the fan (if it is); 3. It is necessary to disconnect all sources of fire, close the gas valve; 4. It is necessary to open windows and doors for ventilation of the room. The presence of hazardous and noxious substances Warranty Warranty service is carried out in accordance with the law on «Consumer Rights» and «Product Quality Law». Warranty service includes: 1. Within 7 days from the date of purchase, in case of a problem with the «Fault list», the Xiaomi Service Center determines the cause of the problem, after which you can choose a free replacement of the goods, return or repair. 2. Within 8-15 days from the date of purchase, in case of a problem with the «Fault list», the Xiaomi Service Center identifies the problem, after which you choose a free replacement of the product or service. 3. Within 12 months from the date of purchase, in case of a problem with the «Fault List», the Xiaomi Service Center determines the problem, after which you are provided with free repair. adhesive tape hard plastic screws circuit board These tables are provided in accordance with SJ / T 11364. A: Toxic and harmful substances in all components of this device are contained in an amount below the threshold value according to the standard GB / T 26572. X: the presence of toxic and noxious substances in at least one of the components of this device in an amount exceeding the threshold value, according to GB / T 26572. Conditions, that are not covered by warranty service 1. Maintenance of the device in unauthorized service centers, improper use, falls, negligence, abuse, water affects, accident, damage to the label and labeling of the device; 2. The warranty has expired; 3. Damage caused by force majeure; 4. Breakdowns, that do not correspond to the «List of faults» of the Xiaomi service center; 5. Breakdown of the device from the «Fault List», which arose in connection with the human factor and prevent its normal operation. XIAOMI-MI.COM