EAST BAY MUNICIPAL UTILITY DISTRICT

Similar documents
INVITATION TO BID. Allendale Elementary School 3670 Penniman Avenue, Oakland, CA 94619

cbever LY) \HILLS/ AGENDA REPORT

SUWANNEE RIVER WATER MANAGEMENT DISTRICT REQUEST FOR BID NO. 15/16-003AO FIRE ALARM SYSTEM INSTALLATION AND MONITORING.

ROSWELL INDEPENDENT SCHOOL DISTRICT P.O. Box 1437 Roswell, New Mexico General Bid Conditions

NOTICE TO CONTRACTORS

Contact Phone Number: (609) Fax: (609)

1. Delete BID FORM in its entirety and replace with the BID FORM attached to this Addendum.

DEPARTMENT OF PUBLIC SAFETY DIVISION OF FIRE PREVENTION AND CONTROL

Annual Fire Systems and Backflow Preventers Testing

REQUEST FOR PROPOSALS CLEANING SERVICES

INVITATION TO BID SUPPLY OF VARIOUS PORTABLE FIRE EXTINGUISHERS

BID PROPOSAL-REVISED

CITY OF LOCKPORT FIRE SPRINKLER & FIRE ALARM SYSTEM INSTALLATION ASSISTANCE PROGRAM

Public Notice of Amendment to New Shoreham General Ordinances Chapter 5 Fire Prevention and Protection New Article IV Fire Alarm Ordinance

MUNICIPALITY OF GREENSTONE BOX 70, 1800 Main Street Geraldton, Ontario P0T 1M0 Telephone Facsimile

IOWA STATE FIRE MARSHAL DIVISION Attn: Licensing Administrator

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

COUNTY OF ROCKLAND Department of General Services Purchasing Division

ARTICLE 4-13 ALARM SYSTEMS * Division 1. Generally

PIKES PEAK REGIONAL BUILDING DEPARTMENT Fire Alarm Contractor License Application

SPECIFICATIONS FOR TENDER # SUPPLY OF A FIRE ALARM SYSTEMS SERVICE AGREEMENT FOR WESTERN HEALTH

Item No. Description 1. BID PROPOSAL FORM Make the following revisions: a. Replace the BID PROPOSAL FORM with the attached BID PROPOSAL FORM.

COMMISSION ORDER. IT IS FURTHER ORDERED that the Request for Bid and Notice to Bidders be displayed on the Franklin County website.

Article 3: Police Regulated Occupations and Businesses. Division 37: Burglary, Robbery and Emergency Alarm Systems

CALIFORNIA STATE TEACHERS RETIREMENT SYSTEM

Sheetz Inc. Fire Protection Service Guidelines

ADDENDUM #1: MODIFICATIONS AND ADDITIONS TO CONTRACT DOCUMENTS

SMALL WORKS PROJECT REQUEST FOR SEALED BIDS

Ventura County Community College District 761 E. Daily Drive, West Stanley Avenue, St. 200, Camarillo, CA Purchasing Department

City of Regina Alarm Bylaw

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

Tennessee Code/TITLE 62 PROFESSIONS, BUSINESSES AND TRADES/CHAPTER 32 FIRE PROTECTION/PART 1 FIRE PROTECTION SPRINKLER SYSTEMS

TEXAS DEPARTMENT OF TRANSPORTATION PORTABLE FIRE EXTINGUISHER SERVICES ANNUAL INSPECTION MAINTENANCE, REPAIR, AND RECHARGING

Sec False alarms.

ORDINANCE NO

Olivenhain Municipal Water District (OMWD) REQUEST FOR PROPOSALS. For. Ultraviolet Disinfection System at. 4S Ranch Water Reclamation Facility

BOARD OF EXAMINERS OF LANDSCAPE ARCHITECTS

EXHIBIT A BE IT ORDAINED BY THE MAYOR AND THE CITY COUNCIL OF THE CITY OF BELLEVUE, NEBRASKA.

Chapter ALARM SYSTEMS

Request For Quotations. For The. Fire Sprinkler Retrofit Program For Licensed Small Or Rural Retirement Homes. October 11, 2017

FIRE & LIFE SAFTEY STANDARD

Invitation to Bid WATER HEATER HHS & WHH

STATEMENT OF WORK ELECTRICAL REPAIR / MAINTENANCE BUILDING PROJECT FDC RACCOON CREEK STATE PARK (BEAVER COUNTY)

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

REQUEST FOR PROPOSAL

INVITATION TO QUOTE. Page 1 of 7. Fire & Emergency Safety Plan Control Number: 2018-CFS-003 Issue Date: March 7, Purpose

ANN ARBOR CITY NOTICE ORDINANCE NO. ORD ALARM SYSTEMS

INVITATION FOR BID Notice to Prospective Bidders

CITY OF MILTON INVITATION TO BID (THIS IS NOT AN ORDER)

Florida Senate SB 982 By Senator Bennett

BUILDING, FIRE, AND LIFE SAFETY CODE ENFORCEMENT AND CERTIFICATION OF INSPECTORS FOR HEALTH FACILITIES LICENSED BY THE STATE OF COLORADO

ARKANSAS FIRE PROTECTION LICENSING BOARD ACT 743 OF 1977

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

REQUEST FOR QUOTES (RFQ) # Issue Date: September 21, 2017

2010 Home Energy-Efficiency Rebate Program

Mr. Burke presented the Airport and Boeing s badging process and public safety issues as outlined in the attached meeting agenda.

maintaining the health, safety and welfare of the citizens of the City and its visitors; and

2019 Landscape Awards

Request for Bid Proposal For Repair of Sprinkler Systems Iowa Veterans Home Marshalltown, Iowa

CITY OF GRETNA, NEBRASKA ORDINANCE 804 AN ORDINANCE CREATING CHAPTER 10 BUSINESS REGULATIONS, ARTICLE 12, ALARM SYSTEMS; TO DEFINE ALARMS; REQUIRING

ROSWELL INDEPENDENT SCHOOL DISTRICT P.O. Box 1437 Roswell, New Mexico General Bid Conditions

BIRCH RUN TOWNSHIP SAGINAW COUNTY, MICHIGAN ORDINANCE # ALARM SYSTEM ORDINANCE

Application Information

Council of the City of York, PA Session 2008 Bill No. Ordinance No. INTRODUCED BY: Genevieve Ray DATE: November 18, 2008

BOARD OF COUNTY COMMISSIONERS


1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

GRAND RIVER DAM AUTHORITY REQUEST FOR QUOTE # 11605

DOCUMENT ADVERTISEMENT FOR BIDS

Advokatfirmaet BAHR AS - ENGAGEMENT TERMS

ALABAMA Propane Gas Association

Purpose Definitions. Chapter BURGLAR ALARM SYSTEMS *

REQUEST FOR PROPOSAL. Fire Suppression System Inspection and Service RFP #UCA

TEXAS CHAPTER AMERICAN SOCIETY OF LANDSCAPE ARCHITECTS 2019 PROFESSIONAL AWARDS GUIDELINES

MONTGOMERY COUNTY RULES GOVERNING ALARMS SECTION 1. PURPOSE SECTION 2. DEFINITIONS

BID FORM CITY OF BEVERLY HILLS. The undersigned, having carefully examined the site conditions and the Contract Documents for

Request for Proposals (RFP) for: Columbia County Facilities Fire Detection and Security Improvements

CORPORATION OF THE CITY OF KINGSTON. Ontario. By-Law Number A By-Law To Impose Fees For Automatic Alarms (False) False Alarm By-law

Save energy at home residential natural gas rebate form

Supply & Installation of Fire Protection System at STPI- Nashik. Tender No. STPI/P/PUR/07/14-15 Date Signature of Bidder

This chapter shall be known as the "City of Bayfield Alarm Systems Ordinance."

HEATING AND COOLING REBATES

HEATING AND COOLING REBATES

Sidney, Ohio 1204 FORMAL ISSUANCE OF CERTIFICATE OF SUBSTANTIAL COMPLETION... ON OR BEFORE JULY 30, 2015.

RULES OF THE TENNESSEE ALARM SYSTEMS CONTRACTORS BOARD CHAPTER GENERAL PROVISIONS TABLE OF CONTENTS

FORM A: PROPOSAL (See B10.2) 1. Contract Title INTEGRATED SOLID WASTE COLLECTION IN THE CITY OF WINNIPEG

1 of 1 DOCUMENT. NEW JERSEY REGISTER Copyright 2009 by the New Jersey Office of Administrative Law

THE REGIONAL MUNICIPALITY OF HALTON POLICE SERVICES BOARD BY-LAW

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE PROTECTION SPRINKLER SYSTEM CONTRACTORS

Authorized individuals to be notified. Include two (2) persons with access to the premises to allow emergency access.

CHAPTER The title of P.L.1983, c.337 is amended to read as follows:

Westerville, OH Code of Ordinances. CHAPTER 969 Alarm Systems

Buying goods/services

2018 Marketing Opportunities

SUPPLEMENTAL WASTE TRANSPORTATION AND DISPOSAL TERMS AND CONDITIONS

Housing Authority of the City of Perth Amboy

Bold items are particular to the City of Euless

CITIZENS POLICE ACADEMY

ARTICLE I. IN GENERAL

Addendum # 2 Wicomico County Circuit Court Second Floor Renovations Date of Addendum: 2/6/2017

Transcription:

EAST BAY MUNICIPAL UTILITY DISTRICT REQUEST FOR PROPOSAL (RFP) No. FMC736-18-01 for AB & AMC Fire Alarm System Testing and Maintenance For complete information regarding this project, see RFP posted at http://www.ebmud.com/business-opportunities or contact the EBMUD representative listed below. Thank you for your interest! Contact Person: David Carlson, Facilities Superintendent Phone Number: (510) 287-0921 E-mail Address: David.Carlson@ebmud.com Please note that prospective bidders are responsible for reviewing http://ebmud.com/business, during the RFP process, for any published addenda regarding this RFP. RESPONSE DUE by 1:30 p.m. on August 9, 2017 at EBMUD, Purchasing Division 375 Eleventh St., First Floor Oakland, CA 94607 375 Eleventh Street, Oakland, CA 94607 Website: ebmud.com Note: EBMUD is committed to reducing environmental impacts across our entire supply chain. If printing this document, please print only what you need, print double-sided, and use recycled-content paper.

I. STATEMENT OF WORK A. SCOPE It is the intent of these specifications, terms, and conditions to describe the requirements for the scheduled testing and maintenance of the fire alarm system devices (smoke detectors, pull stations, flow switches, etc) within the AB & AMC. East Bay Municipal Utility District (District) intends to award a 3-year contract (with 2 options to renew for one-year terms) to the Proposer(s) who best meets the District s requirements. B. BIDDER QUALIFICATIONS 1. Bidder Minimum Qualifications a. Bidder, bidder s principal, or bidder s staff shall have been regularly engaged in the business of providing Fire Alarm System Maintenance for at least five (5) years. b. Bidder shall have staff that is qualified and experienced in the inspection, testing, and maintenance of Notifier by Honeywell systems. c. Bidder shall possess all permits, licenses, and professional credentials necessary to supply product and perform services as specified under this RFP. d. Contractor shall be qualified per Section NFPA 72(2016 Edition), 14.2.3.6. C. SPECIFIC REQUIREMENTS Contractor shall inspect and test the fire alarm equipment at the Administration Building (375 11 th Street) and Adeline Maintenance Campus (AMC). The locations of each building and equipment are described in Tables 1-7 on the following pages. All inspection and testing services shall be completed in accordance with NFPA 72 (2016), sections 14.3 (Inspections), 14.3.1 (Visual Inspection), Table 14.4.3(Testing Methods), and 14.4.3.2(Testing) All in accordance with the terms and conditions contained herein and in the following pages. RFP 08/28/156 1. Fire Alarm System Test/Inspections: The Contractor will perform functional testing and visual inspections on the Fire Alarm System including all

components; control panel equipment, modules, power supplies and batteries; auxiliary/monitoring functions, visual signaling devices, and all initiating devices. 2. Sprinkler Device Test/Inspections (Waterflow and Tamper Valves): The Contractor will perform Semi-Annual functional testing and visual inspections on 100% of the existing sprinkler waterflow control valves and valve tamper devices. 3. UL Certificate: The Contractor will provide a UL Certificate and maintain UL Certification while contracted to perform code required testing and service. The UL Certificate shall be based on the 2010 version of NFPA. 4. Smoke Control System Test/Inspection - Administration Building (ONLY): The Contractor will test the smoke control system to verify automatic operation, smoke purge function, and sequence of operation. These functions and sequence of operation are defined in Exhibit G. This testing shall include functional testing of all electromechanically operated fire/smoke dampers. Direct visual verification of smoke control device position/operation and activation of status lights on the smoke control panel shall be used to confirm operation. EBMUD will be responsible for providing access to the smoke control devices. If any deficiencies are found downstream of the fire alarm control modules (i.e. electrical wiring or mechanical), EBMUD will be responsible for addressing the deficiencies. 5. Documentation: The Contractor will provide a detailed inspection report upon completion of contracted testing and inspections. The report will include Fire Life Safety (FLS) Equipment & Devices checked and detailed report of deficiencies, if applicable. Examples of the expected detail reports can be seen in Exhibit F. In addition to the information included in these reports, the reports shall also provide reference to the District s own unique equipment identification number. The District will provide the Contractor a cross reference between the FAS software points and District s equipment labels prior to testing. 6. Testing: The Contractor will conduct testing services in the following manner: a) Administration Building - Testing services will be conducted after normal business hours. Normal business hours for the Administration Building are 8 AM 5 PM. b) AMC Testing services will be conducted during normal business hours. Normal business hours for the AMC- are 8 AM 5 PM. 7. Number of Inspections a) Administration Building - Contractor shall inspect and/or test at a frequency that satisfies testing code requirements. A service calendar RFP 08/28/156

listing approximate month and equipment to be tested shall be generated and agreed upon 30 days after the contract is executed. b) AMC - Contractor shall inspect and/or test at a frequency that satisfies testing code requirements. A service calendar listing approximate month and equipment to be tested shall be generated and agreed upon 30 days after the contract is executed. D. DELIVERABLES / REPORTS 1. Copies of all Test Reports will be forwarded to the District in both hard and electronic form. All electronic documents must be in a text searchable format such as PDF, Word, or Excel. Example reports are included in Exhibit F. In addition to the information included in these reports, the reports shall also provide a place to record the District s own unique equipment identification number. The District will provide the Contractor a cross reference between the FAS software points and the District s equipment labels prior to testing. RFP 08/28/156

Table 1 Administration Building (375 11 th Street) Equipment List Qty Equipment Make/Model Visual Inspection Frequency / Functional Testing Frequency / NFPA 72 2016 Reference NFPA 72 2016 Reference 1 Fire Alarm Control Panel Notifier NFS2-3030 Annual / Table 14.3.1, Item 1 Annual / Table 14.4.3.2, item 1 1 Digital Alarm Communicator Notifier UDACT-2 Annual / Table 14.3.1, Item 1 Annual / Table 14.4.3.2, item 1 5 Remote Fire Alarm Panel Notifier NFS 320 Annual / Table 14.3.1, Item 1 Annual / Table 14.4.3.2, item 1 1 Smoke Control Panel Kirkland RSG-GR- DP3 Semi-Annual / Table 14.3.1, Item 5 Annual / Table 14.4.3.2, item 1 16 Remote Power Supply Notifier ACPS-610E Annual / Table 14.3.1, Item 30 Annual / Table 14.4.3.2, item 7 4 VESDA Various Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 51 Pull Station Notifier NBG-12LX Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 18 Duct Detectors System Sensor DNR Duct Smoke Detector Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 185 Smoke Detectors Notifier FSP-851 Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 18 Heat Detectors Notifier FST-851 Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 18 Waterflow Switches Various Quarterly / Table 14.3.1, Item 17 Semi-Annual / Table 14.4.3.2, item 17 25 Tamper Switches Various Quarterly / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 3 Notes Contractor shall be responsible for completing two visual inspections per year and semiannual functional testing. District to complete two visual inspections per year. 516 Audio/Visual Devices System Sensor Semi-Annual / Table 14.3.1, Item 22 Annual / Table 14.4.3.2, item 30 453 Speaker Strobes, 9 Speakers, & 54 Strobes 29 Electromagnetic Door Holder Various Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 36 Fireman Phone Jack Various Semi-Annual / Table 14.3.1, Item 5 Annual / Table 14.4.3.2, item 5 6 Fireman Phone Handsets Various Semi-Annual / Table 14.3.1, Item 5 Annual / Table 14.4.3.2, item 5 8 Emergency Phones Various Semi-Annual / Table 14.3.1, Item 5 Annual / Table 14.4.3.2, item 5 In stairwells 38 Batteries Notifier BAT Series Semi-Annually / Table 14.3.1, Item 9 Semi-Annual / Table 14.4.3.2, item 9 RFP 08/28/156

Table 2 AMC Admin (1100 21 st Street) Equipment List Qty Equipment Make/Model Visual Inspection Frequency / Functional Testing Frequency / NFPA 72 2016 Reference NFPA 72 2016 Reference Notes 1 Fire Alarm Control Panel Notifier NFS 320 Annual / Table 14.3.1, Item 1 Annual / Table 14.4.3.2, item 1 1 Digital Alarm Communicator Notifier UDACT-2 Annual / Table 14.3.1, Item 1 Annual / Table 14.4.3.2, item 1 1 Remote Annunciator Notifier Semi-Annual / Table 14.3.1, Item 11 Annual / Table 14.4.3.2, item 11 1 Remote Power Supply Notifier ACPS-610E Annual / Table 14.3.1, Item 30 Annual / Table 14.4.3.2, item 7 12 Pull Station Notifier NBG-12LX Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 3 Duct Detectors System Sensor DNR Duct Smoke Detector Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 16 Smoke Detectors Notifier FSP-851 Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 1 Heat Detectors Notifier FST-851 Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 2 4 Waterflow Switches Tamper Switches Various Various Semi-Annual / Table 14.3.1, Item 17 Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 Annual / Table 14.4.3.2, item 17 Contractor shall be responsible for completing two visual inspections per year and annual functional testing. District to complete two visual inspections per year. 84 Audio/Visual Devices System Sensor Semi-Annual / Table 14.3.1, Item 22 Annual / Table 14.4.3.2, item 30 53 Horn Strobes & 31 Strobes 3 Electromagnetic Door Holder Various Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 2 Batteries Notifier BAT Series Semi-Annually / Table 14.3.1, Item 9 Semi-Annual / Table 14.4.3.2, item 9 RFP 08/28/156

Table 3 AMC Materials Testing (1100 21 st Street) Equipment List Qty Equipment Make/Model Visual Inspection Frequency / Functional Testing Frequency / NFPA 72 2010 Reference NFPA 72 2010 Reference Notes 1 Fire Alarm Control Panel Notifier NFS 320 Annual / Table 14.3.1, Item 1 Annual / Table 14.4.3.2, item 1 1 Digital Alarm Communicator Notifier UDACT-2 Annual / Table 14.3.1, Item 1 Annual / Table 14.4.3.2, item 1 1 Remote Power Supply Notifier ACPS-610E Annual / Table 14.3.1, Item 13 Annual / Table 14.4.5, item 7 1 Pull Station Notifier NBG-12LX Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 3 Smoke Detectors Notifier FSP-851 Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 1 4 Waterflow Switches Tamper Switches Various Various Semi-Annual / Table 14.3.1, Item 17 Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 Annual / Table 14.4.3.2, item 17 Contractor shall be responsible for completing two visual inspections per year and annual functional testing. District to complete two visual inspections per year. 3 Audio/Visual Devices System Sensor Semi-Annual / Table 14.3.1, Item 22 Annual / Table 14.4.3.2, item 30 3 Horn Strobes 2 Batteries Notifier BAT Series Semi-Annually / Table 14.3.1, Item 17 Semi-Annual / Table 14.4.3.2, item 9 Table 4 AMC Stores (1200 21 st Street) Equipment List Qty Equipment Make/Model Visual Inspection Frequency / Functional Testing Frequency / NFPA 72 2016 Reference NFPA 72 2016 Reference Notes 1 Fire Alarm Control Panel Notifier NFS 320 Annual / Table 14.3.1, Item 1 Annual / Table 14.4.3.2, item 1 1 Digital Alarm Communicator Notifier UDACT-2 Annual / Table 14.3.1, Item 1 Annual / Table 14.4.3.2, item 1 1 Remote Annunciator Notifier Semi-Annual / Table 14.3.1, Item 11 Annual / Table 14.4.3.2, item 11 5 Pull Station Notifier NBG-12LX Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 2 Duct Detectors System Sensor DNR Duct Smoke Detector Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 10 Smoke Detectors Notifier FSP-851 Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 1 1 Waterflow Switches Tamper Switches Various Various Semi-Annual / Table 14.3.1, Item 17 Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 Annual / Table 14.4.3.2, item 17 Contractor shall be responsible for completing two visual inspections per year and annual functional testing. District to complete two visual inspections per year. 23 Audio/Visual Devices System Sensor Semi-Annual / Table 14.3.1, Item 22 Annual / Table 14.4.3.2, item 30 20 Horn Strobes & 3 Strobes 2 Electromagnetic Door Holder Various Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 9 RFP 08/28/156

Table 5 AMC CMS (2149 Union Street) Equipment List Qty Equipment Make/Model Visual Inspection Frequency / Functional Testing Frequency / NFPA 72 2016 Reference NFPA 72 2016 Reference Notes 1 Fire Alarm Control Panel Notifier NFS 320 Annual / Table 14.3.1, Item 1 Annual / Table 14.4.3.2, item 1 1 Digital Alarm Communicator Notifier UDACT-2 Annual / Table 14.3.1, Item 1 Annual / Table 14.4.3.2, item 1 3 Pull Station Notifier NBG-12LX Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 4 Duct Detectors System Sensor DNR Duct Smoke Detector Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 17 Smoke Detectors Notifier FSP-851 Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 6 Heat Detectors Notifier FST-851 Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 13 Audio/Visual Devices System Sensor Semi-Annual / Table 14.3.1, Item 22 Annual / Table 14.4.3.2, item 30 13 Horn Strobes Table 6 AMC Fleet (1199 21 st Street) Equipment List Qty Equipment Make/Model Visual Inspection Frequency / Functional Testing Frequency / NFPA 72 2016 Reference NFPA 72 2016 Reference 1 Fire Alarm Control Panel Notifier NFS 320 Annual / Table 14.3.1, Item 1 Annual / Table 14.4.3.2, item 1 1 Digital Alarm Communicator Notifier UDACT-2 Annual / Table 14.3.1, Item 1 Annual / Table 14.4.3.2, item 1 3 Pull Station Notifier NBG-12LX Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 2 Duct Detectors System Sensor DNR Duct Smoke Detector Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 8 Smoke Detectors Notifier FSP-851 Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 1 Heat Detectors Notifier FST-851 Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 Notes Integrated in AC-1. Monitored by point L1-18 1 4 Waterflow Switches Tamper Switches Various Various Semi-Annual / Table 14.3.1, Item 17 Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 Annual / Table 14.4.3.2, item 17 Contractor shall be responsible for completing two visual inspections per year and annual functional testing. District to complete two visual inspections per year. 7 Audio/Visual Devices System Sensor Semi-Annual / Table 14.3.1, Item 22 Annual / Table 14.4.3.2, item 30 7 Horn Strobes RFP 08/28/156

Table 7 AMC Shops (1200 21 st Street) Equipment List Qty Equipment Make/Model Visual Inspection Frequency / Functional Testing Frequency / NFPA 72 2016 Reference NFPA 72 2016 Reference Notes 1 Fire Alarm Control Panel Notifier NFS 320 Annual / Table 14.3.1, Item 1 Annual / Table 14.4.3.2, item 1 1 Digital Alarm Communicator Notifier UDACT-2 Annual / Table 14.3.1, Item 1 Annual / Table 14.4.3.2, item 1 1 Remote Annunciator Notifier Semi-Annual / Table 14.3.1, Item 11 Annual / Table 14.4.3.2, item 11 2 Remote Power Supply Notifier ACPS-610E Annual / Table 14.3.1, Item 30 Annual / Table 14.4.3.2, item 7 19 Pull Station Notifier NBG-12LX Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 20 Duct Detectors System Sensor DNR Duct Smoke Detector Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 13 Smoke Detectors Notifier FSP-851 Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 1 Heat Detectors Notifier FST-851 Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 2 5 Waterflow Switches Tamper Switches Various Various Semi-Annual / Table 14.3.1, Item 17 Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 Annual / Table 14.4.3.2, item 17 Contractor shall be responsible for completing two visual inspections per year and annual functional testing. District to complete two visual inspections per year. 82 Audio/Visual Devices System Sensor Semi-Annual / Table 14.3.1, Item 22 Annual / Table 14.4.3.2, item 30 58 Horn Strobes & 24 Strobes 2 Electromagnetic Door Holder Various Semi-Annual / Table 14.3.1, Item 17 Annual / Table 14.4.3.2, item 17 4 Batteries Notifier BAT Series Semi-Annually / Table 14.3.1, Item 9 Semi-Annual / Table 14.4.3.2, item 9 RFP 08/28/156

AB & AMC Fire Alarm System Testing and Maintenance II. CALENDAR OF EVENTS EVENT RFP Issued July 17, 2017 Deadline For Submission of Questions July 24, 2017 MANDATORY Site Walk August 2, 2017 @ 8:00AM DATE/LOCATION at: EBMUD Adeline Maintenance Center Security Desk 1100 21 th Street Oakland, CA 94607 Addendum to Announce Pre-Approved Equivalents (if necessary) Response Due Anticipated Contract Start Date August 9, 2017 by 1:30 p.m. November 1, 2017 Note: All dates are subject to change. Bidders are responsible for reviewing http://ebmud.com/business for any published addenda. Hard copies of addenda will not be mailed out. A. MANDATORY SITE WALK/ BID CONFERENCE Mandatory site walk/bid conference will be held to: 1. Allow the District to discuss the scope of the project. 2. Provide bidders an opportunity to view all site, receive documents, etc., necessary to respond to this RFP. 3. Provide an opportunity for bidders to ask specific questions about the project and request RFP clarifications. 4. Provide the District with an opportunity to receive feedback regarding the project and RFP. 5. The site walk will begin at the Admin Maintenance Center. Once completed, we will proceed to the Administration Building for part two of the site visit. RFP No. FMC736-18-01 RFP 08/28/16 Page 3

AB & AMC Fire Alarm System Testing and Maintenance 6. Prospective bidders must contact David Carlson no later than Monday, July 31, 2017 to reserve a spot for the site walk. Name, Company Name, and Phone Number of each attendee will be required to reserve a spot. A valid Government Photo issued ID will be required to gain access onto the property. All questions deemed to be pertinent by the District will be addressed in an Addendum following the site walk/bid conference. ***In order to be eligible to bid on this RFP, a representative from the bidder s company MUST attend site walk/bid conference at both locations and sign in to confirm her/his attendance. If an RFP response is submitted by a company that was not in attendance at this meeting, its RFP response WILL be rejected*** III. DISTRICT PROCEDURES, TERMS, AND CONDITIONS A. RFP ACCEPTANCE AND AWARD 1. RFP responses will be evaluated to determine that they are responsive, responsible, and that they meet the specifications as stated in this RFP. 2. The District reserves the right to award to a single or to multiple Contractors, dependent upon what provides the lowest overall cost to the District. 3. The District has the right to decline to award this contract or any part of it for any reason. 4. Any specifications, terms or conditions, issued by the District, or those included in the bidder s submission, in relation to this RFP, may be incorporated into any PO or contract that may be awarded as a result of this RFP. 5. Award of contract. The right is reserved to reject any or all proposals, to accept one part of a proposal and reject the other, unless the bidder stipulates to the contrary, and to waive technical defects, as the interest of the District may require. Award will be made or proposals rejected by the District as soon as possible after bids have been opened. B. BRAND NAMES, APPROVED EQUIVALENTS, DEVIATIONS, AND EXCEPTIONS Any references to manufacturers, trade names, brand names, and/or catalog numbers are intended to be descriptive, but not restrictive, unless otherwise stated, and are intended to indicate the quality level desired. Bidders may offer an equivalent product that meets or exceeds the specifications. The District reserves the right to be the sole judge of what shall be considered equal and/or acceptable, and may require the bidder to provide additional information and/or RFP No. FMC736-18-01 RFP 08/28/16 Page 4

AB & AMC Fire Alarm System Testing and Maintenance samples. If the bidder does not specify otherwise, it is understood that the brand and/or product referenced in this RFP will be supplied. Taking exception to the RFP, or failure on the part of the bidder to comply with all requirements and conditions of this RFP, may subject the RFP response to rejection. If no deviations are shown, the bidder will be required to furnish the material exactly as specified. The burden of proof of compliance with the specifications will be the responsibility of the bidder. This RFP is subject to acceptance only on the terms and conditions stated in this RFP. Any additional or different terms and conditions proposed by the bidder are hereby rejected, and shall be of no force or effect unless expressly assented to in writing by the District. RFP responses based on equivalent products must use Exhibit A Exceptions, Clarification and Amendments to: C. PRICING a. Clearly describe the alternate offered and indicate specifically how it differs from the product specified in this RFP b. Include complete descriptive literature and/or specifications as proof that the proposed alternate will be equal to or better than the product named in this RFP 1. All prices are to be F.O.B. destination. Any freight/delivery charges are to be included. 2. All prices quoted shall be in United States dollars. 3. Price quotes shall include any and all payment incentives available to the District. 4. Bidders are advised that in the evaluation of cost, if applicable, it will be assumed that the unit price quoted is correct in the case of a discrepancy between the unit price and extended price. 5. Prevailing Wages: All Contractors bidding on a public works project and all Subcontractors of any tier shall be registered with the State Department of Industrial Relations pursuant to Section 1725.5 of the Labor Code. RFP No. FMC736-18-01 RFP 08/28/16 Page 5

D. PROTESTS AB & AMC Fire Alarm System Testing and Maintenance The Contractor shall post a copy of the general prevailing rate of per diem wages at the jobsite pursuant to Section 1773.2 of the Labor Code of the State of California. Pursuant to the provisions of Division 2, Part 7, Chapter 1, Article 2, and any amendments thereof of the Labor Code of the State of California, the Contractor and any subcontractor under him shall pay not less than the specified prevailing rate of wages to all workers employed in the execution of the contract. The Contractor shall, as a penalty to the State or the District, forfeit Twenty-Five ($25.00) Dollars for each calendar day, or portion thereof, for each worker paid less than the stipulated prevailing rates for any work or craft in which such worker is employed under the contract by the Contractor or by any subcontractor under him. The difference between such stipulated prevailing wage rates and the amount paid to such worker for each calendar day or portion thereof for which each worker was paid less than the stipulated prevailing wage rate shall be paid to each worker by the Contractor. The provisions of Section 1776 of the Labor Code of the State of California shall be complied with by the Contractor. For all classes of work not specified herein, the minimum wage shall be that specified for general laborer. The specified wage rates are minimum rates only and the District will not consider and shall not be liable for any claims for additional compensation made by the Contractor because of payment by him of any wage rate in excess of the general prevailing rates. All disputes in regard to the payment of wages in excess of those specified herein shall be adjusted by the Contractor at his own expense. The holidays upon which such rates shall be paid shall be all holidays recognized in the collective bargaining agreement applicable to the particular craft, classification, or type of worker employed on the project. Protests must be in writing and must be received no later than seven (7) business days after the District issues the Notice of Intent to Award, which is sent to all entities who submitted a bid package. The District will reject the protest as untimely if it is received after this specified time frame. Protests will be accepted from bidders or potential bidders only. If the protest is mailed and not received by the District, the protesting party bears the burden of proof to submit evidence (e.g., certified mail receipt) that the protest was sent in a timely manner so that it would be received by the District within the RFP protest period. RFP No. FMC736-18-01 RFP 08/28/16 Page 6

AB & AMC Fire Alarm System Testing and Maintenance Bid protests must contain a detailed and complete written statement describing the reason(s) for protest. The protest must include the name and/or number of the bid, the name of the firm protesting, and include a name, telephone number, email address and physical address of the protestor. If a firm is representing the protestor, they shall include their contact information in addition to that of the protesting firm. Protests must be mailed or hand delivered to the Manager of Purchasing, East Bay Municipal Utility District, 375 Eleventh Street, Oakland, CA 94607 or P.O. Box 24055, Oakland, California 94623. Facsimile and electronic mail protests must be followed by a mailed or hand delivered identical copy of the protest and must arrive within the seven day time limit. Any bid protest filed with any other District office shall be forwarded immediately to the Manager of Purchasing. The bid protester can appeal the determination to the requesting organization s Department Director. The appeal must be submitted to the Department Director no later than five working days from the date of receipt of the requesting organization s determination on the protest. Such an appeal must be made in writing and must include all grounds for the appeal and copies of the original protest and the District s response. The bid protester must also send the Purchasing Division a copy of all materials sent to the Department Director. The Department Director will make a determination of the appeal and respond to the protester by certified mail in a timely manner. If the appeal is denied, the letter will include the date, time, and location of the Board of Directors meeting at which staff will make a recommendation for award and inform the protester it may request to address the Board of Directors at that meeting. The District may transmit copies of the protest and any attached documentation to all other parties who may be affected by the outcome of the protest. The decision of the District as to the validity of any protest is final. This District s final decision will be transmitted to all affected parties in a timely manner. E. METHOD OF ORDERING 1. Written POs may be issued upon approval of written itemized quotations received from the Contractor. 2. Individual order price quotations shall be provided upon request per project and shall include, but not be limited to, an identifying (quotation) number, date, requestor name and phone number, ship to location, itemization of products and/or services with complete description (including model numbers, fabric and RFP No. FMC736-18-01 RFP 08/28/16 Page 7

AB & AMC Fire Alarm System Testing and Maintenance finish grade, description, color, etc.) and price per item, and a summary of total cost for product, services, shipping, and tax. 3. POs and payments for products and/or services will be issued only in the name of Contractor. 4. Any and all change orders shall be in writing and agreed upon, in advance, by Contractor and the District. F. TERM / TERMINATION / RENEWAL 1. The term of the contract, which may be awarded pursuant to this RFP, will be 3 years. 2. At the sole discretion of the District, any contract which may be awarded pursuant to this RFP, may be extended for two (2) additional one-year terms at agreed prices with all other terms and conditions remaining the same. In the event that a Contractor does not agree to an extension, the District shall be given a minimum of 90 days notice to locate a suitable replacement contractor. 3. This Agreement may be terminated for convenience by the District provided the Contractor is given written notice of not less than 30 calendar days. Upon such termination, the District shall pay the Contractor the amount owing for the products ordered and satisfactorily received by the District. This shall be the sole and exclusive remedy to which the Contractor is properly entitled in the event of termination by the District. 4. This Agreement may be terminated for cause at any time, provided that the District notifies Contractor of impending action. G. WARRANTY 1. Bidder expressly warrants that all goods and services to be furnished pursuant to any contract awarded it arising from the Bid will conform to the descriptions and specifications contained herein and in supplier catalogs, product brochures and other representations, depictions or models, and will be free from defects, of merchantable quality, good material, and workmanship. Bidder expressly warrants that all goods and services to be furnished pursuant to such award will be fit and sufficient for the purpose(s) intended. This warranty shall survive any inspections, delivery, acceptance, payment, or contract termination for any reason, by the District. Bidder warrants that all work, materials installed, and services furnished hereunder shall be guaranteed for a period of 1 year from the date of acceptance by the District. RFP No. FMC736-18-01 RFP 08/28/16 Page 8

H. INVOICING AB & AMC Fire Alarm System Testing and Maintenance a. In the event that any work is performed by a subcontractor and is in need of repair during the warranty period, the District will contact the primary contractor to perform warranty work. In the event that the primary contractor is nonresponsive, the District will have the work performed by District Forces or another contractor of its choice and bill the contractor for the work performed. 1. Payment will be made within thirty (30) days following receipt of a correct invoice and upon complete satisfactory receipt of product and/or performance of services. The District and the successful bidder will determine the invoicing method during the maintenance and testing schedule meeting, which will be held within 30 days of the contract being executed. 2. The District shall notify Contractor of any invoice adjustments required. 3. Invoices shall contain, at a minimum, District PO number, invoice number, remit to address, and itemized products and/or services description. 4. The District will pay Contractor in an amount not to exceed the total amount quoted in the RFP response. 5. All deliverables must be submitted to and approved by the District, in writing, prior to the final payment being issued I. BONDS 1. The successful bidder will be required to post and maintain a Payment Bond for one hundred percent (100%) of the total contract amount with the District. Bonds must be on District forms attached to this RFP as Exhibit D - Bond Forms. IV. RFP RESPONSE SUBMITTAL INSTRUCTIONS AND INFORMATION A. DISTRICT CONTACTS All contact during the competitive process is to be through the contact listed on the first page of this RFP. The following persons are only to be contacted for the purposes specified below. TECHNICAL SPECIFICATIONS: EBMUD- David Carlson, Facilities Superintendent E-Mail: David.Carlson@ebmud.com PHONE: (510) 287-0921 RFP No. FMC736-18-01 RFP 08/28/16 Page 9

AB & AMC Fire Alarm System Testing and Maintenance CONTRACT EQUITY PROGRAM: Attn: Contract Equity Office PHONE: (510) 287-0114 AFTER AWARD: EBMUD- David Carlson, Facilities Superintendent E-Mail: David.Carlson@ebmud.com PHONE: (510) 287-0921 B. SUBMITTAL OF RFP RESPONSE 1. Responses must be submitted in accordance with Exhibit A RFP Response Packet, including all additional documentation stated in the Required Documentation and Submittals section of Exhibit A. 2. Late and/or unsealed responses will not be accepted. 3. RFP responses submitted via electronic transmissions will not be accepted. Electronic transmissions include faxed RFP responses or those sent by electronic mail ( e-mail ). 4. RFP responses will be received only at the address shown below, must be SEALED, and must be received at the District Purchasing Division by 1:30 p.m. on the due date specified in the Calendar of Events. Any RFP response received after that time or date, or at a place other than the stated address cannot be considered and will be returned to the bidder unopened. All RFP responses must be received and time stamped at the stated address by the time designated. The Purchasing Division's timestamp shall be considered the official timepiece for the purpose of establishing the actual receipt of RFP responses. 5. RFP responses are to be addressed/delivered as follows: Mailed: Andrew Akelman, Manager of Purchasing East Bay Municipal Utility District AB & AMC Fire Alarm System Testing and Maintenance RFP No. FMC736-18-01 EBMUD Purchasing Division P.O. Box 24055 Oakland, CA 94623 RFP No. FMC736-18-01 RFP 08/28/16 Page 10

AB & AMC Fire Alarm System Testing and Maintenance Hand Delivered or delivered by courier or package delivery service: Andrew Akelman, Manager of Purchasing East Bay Municipal Utility District AB & AMC Fire Alarm System Testing and Maintenance RFP No. FMC736-18-01 EBMUD Purchasing Division 375 Eleventh Street, First Floor Oakland, CA 94607 Bidder's name, return address, and the RFP number and title must also appear on the mailing package. 6. All costs required for the preparation and submission of an RFP response shall be borne by the bidder. 7. California Government Code Section 4552: In submitting an RFP response to a public purchasing body, the bidder offers and agrees that if the RFP response is accepted, it will assign to the purchasing body all rights, title, and interest in and to all causes of action it may have under Section 4 of the Clayton Act (15 U.S.C. Sec. 15) or under the Cartwright Act (Chapter 2, commencing with Section 16700, of Part 2 of Division 7 of the Business and Professions Code), arising from purchases of goods, materials, or services by the bidder for sale to the purchasing body pursuant to the RFP response. Such assignment shall be made and become effective at the time the purchasing body tenders final payment to the bidder. 8. Bidder expressly acknowledges that it is aware that if a false claim is knowingly submitted (as the terms claim and knowingly are defined in the California False Claims Act, Cal. Gov. Code, 12650 et seq.), the District will be entitled to civil remedies set forth in the California False Claim Act. 9. The RFP response shall remain open to acceptance and is irrevocable for a period of one hundred eighty (180) days, unless otherwise specified in the RFP documents. 10. It is understood that the District reserves the right to reject any or all RFP responses. 11. RFP responses, in whole or in part, are NOT to be marked confidential or proprietary. The District may refuse to consider any RFP response or part thereof so marked. RFP responses submitted in response to this RFP may be subject to public disclosure. The District shall not be liable in any way for disclosure of any such records. RFP No. FMC736-18-01 RFP 08/28/16 Page 11

EXHIBIT A RFP RESPONSE PACKET RFP No. FMC736-18-01 AB & AMC Fire Alarm System Testing and Maintenance To: From: The EAST BAY MUNICIPAL UTILITY District ( District ) (Official Name of Bidder) RFP RESPONSE PACKET GUIDELINES BIDDERS ARE TO SUBMIT ONE (1) ORIGINAL HARDCOPY RFP RESPONSE WITH ORIGINAL INK SIGNATURES, ONE COPY, AND ONE (1) ELECTRONIC COPY (in PDF format on a CD or flash drive) CONTAINING THE FOLLOWING, IN THEIR ENTIRETY: o EXHIBIT A RFP RESPONSE PACKET, INCLUDING CONTRACT EQUITY PROGRAM FORMS AND ALL ADDITIONAL REQUIRED DOCUMENTATION AS DESCRIBED IN EXHIBIT A - REQUIRED DOCUMENTATION AND SUBMITTALS o EXHIBIT B INSURANCE REQUIREMENTS o EXHIBIT C GENERAL REQUIREMENTS o EXHIBIT D BOND FORMS o EXHIBIT E ELIGIBILITY TO WORK ON PUBLIC WORKS PROJECTS FROM o EXHIBIT F SAMPLE INSPECTION REPORTS o EXHIBIT G AB FAS & SMOKE CONTROL PANEL SEQUENCE OF OPERATIONS AND INTELOCKS ALL PRICES AND NOTATIONS MUST BE PRINTED IN INK OR TYPEWRITTEN; NO ERASURES ARE PERMITTED; ERRORS MAY BE CROSSED OUT AND CORRECTIONS PRINTED IN INK OR TYPEWRITTEN ADJACENT, AND MUST BE INITIALED IN INK BY PERSON SIGNING THE RFP RESPONSE. BIDDERS THAT DO NOT COMPLY WITH THE REQUIREMENTS, AND/OR SUBMIT AN INCOMPLETE RFP RESPONSE MAY BE SUBJECT TO DISQUALIFICATION AND THEIR RFP RESPONSE REJECTED IN TOTAL. IF BIDDERS ARE MAKING ANY CLARIFICATIONS AND/OR AMENDMENTS, OR TAKING EXCEPTION TO ANY PART OF THIS RFP, THESE MUST BE SUBMITTED IN THE EXCEPTIONS, CLARIFICATIONS, AND AMENDMENTS SECTION OF THIS EXHIBIT A RFP RESPONSE PACKET. THE DISTRICT, AT ITS SOLE DISCRETION, MAY ACCEPT AMENDMENTS/EXCEPTIONS, OR MAY DEEM THEM TO BE UNACCEPTABLE, THEREBY RENDERING THE RFP RESPONSE DISQUALIFIED. Exhibit A RFP No. FMC736-18-01 RFP 08/28/16 Page 1

BIDDERS SHALL NOT MODIFY DISTRICT LANGUAGE IN ANY PART OF THIS RFP OR ITS EXHIBITS, NOR SHALL THEY QUALIFY THEIR RFP RESPONSE. Exhibit A RFP No. FMC736-18-01 RFP 08/28/16 Page 2

BIDDER INFORMATION AND ACCEPTANCE 1. The undersigned declares that all RFP documents, including, without limitation, the RFP, Addenda, and Exhibits, have been read and that the terms, conditions, certifications, and requirements are agreed to. 2. The undersigned is authorized to offer, and agrees to furnish, the articles and services specified in accordance with the RFP documents of RFP No. FMC736-18-01. 3. The undersigned acknowledges acceptance of all addenda related to this RFP. List Addenda for this RFP on the lines below: Addendum # Date 4. The undersigned hereby certifies to the District that all representations, certifications, and statements made by the bidder, as set forth in this RFP Response Packet and attachments, are true and correct and are made under penalty of perjury pursuant to the laws of California. 5. The undersigned acknowledges that the bidder is, and will be, in good standing in the State of California, with all the necessary licenses, permits, certifications, approvals, and authorizations necessary to perform all obligations in connection with this RFP and associated RFP documents. 6. It is the responsibility of each bidder to be familiar with all of the specifications, terms, and conditions and, if applicable, the site condition. By the submission of an RFP response, the bidder certifies that if awarded a contract it will make no claim against the District based upon ignorance of conditions or misunderstanding of the specifications. 7. Patent indemnity: Contractors who do business with the District shall hold the District, its Directors, officers, agents, and employees, harmless from liability of any nature or kind, including cost and expenses, for infringement or use of any patent, copyright, or other proprietary right, secret process, patented or unpatented invention, article, or appliance furnished or used in connection with the contract or purchase order. Exhibit A RFP No. FMC736-18-01 RFP 08/28/16 Page 3

8. Insurance certificates are not required at the time of submission. However, by signing Exhibit A RFP Response Packet, the bidder agrees to meet the minimum insurance requirements stated in the RFP. This documentation must be provided to the District prior to execution of an agreement by the District, and shall include an insurance certificate which meets the minimum insurance requirements, as stated in the RFP. 9. The undersigned bidder hereby submits this RFP response and binds itself on award to the District under this RFP to execute in accordance with such award a contract and to furnish the bond or bonds and insurance required by the RFP. The RFP, subsequent Addenda, bidder s Response Packet, and any attachments, shall constitute the Contract, and all provisions thereof are hereby accepted. 10. The undersigned acknowledges ONE of the following (please check only one box)*: Bidder is not an SBE and is ineligible for any bid preference; OR Bidder is an SBE or DVBE as described in the Contract Equity Program (CEP) and Equal Employment Opportunity (EEO) Guidelines, is requesting a 5% bid preference, and has completed the Contract Equity Program and Equal Employment Opportunity forms at the hyperlink contained in the Contract Equity Program and Equal Opportunity section of this Exhibit A. *If no box is checked, it will be assumed that the bidder is ineligible for bid preference and none will be given. For additional information on SBE bid preference, please refer to the Contract Equity Program and Equal Employment Opportunity Guidelines at the above referenced hyperlink. Official Name of Bidder (exactly as it appears on Bidder s corporate seal and invoice): Street Address Line 1: Street Address Line 2: City: State: Zip Code: Webpage: Type of Entity / Organizational Structure (check one): Corporation Limited Liability Partnership Limited Liability Corporation Joint Venture Partnership Non-Profit / Church Other: Jurisdiction of Organization Structure: Date of Organization Structure: Exhibit A RFP No. FMC736-18-01 RFP 08/28/16 Page 4

Federal Tax Identification Number: Department of Industrial Relations (DIR) Registration Number: Primary Contact Information: Name / Title: Telephone Number: Fax Number: E-mail Address: Street Address Line 1: City: State: Zip Code: SIGNATURE: Name and Title of Signer (printed): Dated this day of 20 Exhibit A RFP No. FMC736-18-01 RFP 08/28/16 Page 5

BID FORM(S) Cost shall be submitted on this Bid Form as is. The prices quoted shall not include Sales Tax or Use Tax; said tax, wherever applicable, will be paid by the District to the contractor, if licensed to collect, or otherwise directly to the State. No alterations or changes of any kind to the Bid Form(s) are permitted. RFP responses that do not comply may be subject to rejection in total. The cost quoted below shall be the cost the District will pay for the term of any contract that is a result of this RFP process. Quantities listed herein are annual estimates based on past usage and are not to be construed as a commitment. No minimum or maximum is guaranteed or implied. Description (Building) Year 1 Unit Cost Year 2 Unit Cost Year 3 Unit Cost AMC Admin $ $ $ $ AMC Material Testing $ $ $ $ AMC Stores $ $ $ $ AMC Construction & Maintenance $ $ $ $ AMC Fleet $ $ $ $ AMC Shops $ $ $ $ Administration Building $ $ $ $ TOTAL COST $ Extended Cost Exhibit A RFP No. FMC736-18-01 RFP 08/28/16 Page 6

REQUIRED DOCUMENTATION AND SUBMITTALS All of the specific documentation listed below is required to be submitted with the Exhibit A RFP Response Packet. Bidders shall submit all documentation, in the order listed below, and clearly label each section of the RFP response with the appropriate title (i.e. Table of Contents, Letter of Transmittal, Key Personnel, etc.). 1. Description of the Proposed Equipment/System: RFP response shall include a description of the proposed equipment/system, as it will be finally configured during the term of the contract. The description shall specify how the proposed equipment/system will meet or exceed the requirements of the District and shall explain any advantages that this proposed equipment/system would have over other possible equipment/systems. The description shall include any disadvantages or limitations that the District should be aware of in evaluating the RFP response. Finally, the description shall describe all product warranties provided by bidder. 2. Benchmark Product Submission: Contractor shall submit, with their bid package or prior to award, and at no cost to the District, sample product(s) which meet or exceed the requirements of this RFP and are indicative of all future products of this type that will be received by the District. The District shall retain benchmark products which will be used to compare against future deliveries in order to assess quality and consistency. 3. Implementation Plan and Schedule: The RFP response shall include an implementation plan and schedule. The plan for implementing the proposed equipment/system and services shall include an Acceptance Test Plan. In addition, the plan shall include a detailed schedule indicating how the bidder will ensure adherence to the timetables for the final equipment/system and/or services. 4. Evidence of Qualification Testing: RFP response provides evidence that the proposed equipment/system has successfully completed the qualification test standard requirements defined in this RFP. Evidence shall include a statement from an Independent Testing Authority (ITA) that both the hardware elements and the software elements of the proposed equipment/system comply with the requirements of the qualification standard. If the equipment/system specified requires the addition of components or features not previously tested by the ITA, the District will determine, in its sole discretion, whether qualification testing of such components or features will be required prior to the award of a contract. 5. Sustainability Statement: Contractors shall submit a statement regarding any sustainable or environmental initiatives or practices that they or their suppliers engage in. This information can be in relation to the specific products procured under this RFP or in relation to the manufacture, delivery, or office practices of your firm which relate to the provision of these products. Exhibit A RFP No. FMC736-18-01 RFP 08/28/16 Page 7

6. Performance Bond/ Performance Requirements: See Exhibit D (PAYMENT BOND) 7. References: References MUST be for testing and maintenance of fire alarm systems in the same manner as that which is described in this RFP. (a) (b) (c) Bidders must use the templates in the References section of this Exhibit A RFP Response Packet to provide references. References should have similar scope, volume, and requirements to those outlined in these specifications, terms, and conditions. Bidders must verify the contact information for all references provided is current and valid. Bidders are strongly encouraged to notify all references that the District may be contacting them to obtain a reference. The District may contact some or all of the references provided in order to determine Bidder s performance record on work similar to that described in this RFP. The District reserves the right to contact references other than those provided in the RFP response. 8. Exceptions, Clarifications, Amendments: (a) (b) The RFP response shall include a separate section calling out all clarifications, exceptions, and amendments, if any, to the RFP and associated RFP documents, which shall be submitted with Bidder s RFP response using the template in the Exceptions, Clarifications, Amendments section of this Exhibit A RFP Response Packet. THE DISTRICT IS UNDER NO OBLIGATION TO ACCEPT ANY EXCEPTIONS, AND SUCH EXCEPTIONS MAY BE A BASIS FOR RFP RESPONSE DISQUALIFICATION. 9. Contract Equity Program: (a) Every bidder must fill out, sign, and submit the appropriate sections of the Contract Equity Program and Equal Employment Opportunity documents located at the hyperlink contained in the last page of this Exhibit A. Special attention should be given to completing Form P-25, "Contractor Employment Data and Certification. Any bidder needing assistance in completing these forms should contact the District's Contract Equity Office at (510) 287-0114 prior to submitting an RFP response. Exhibit A RFP No. FMC736-18-01 RFP 08/28/16 Page 8

REFERENCES RFP No. FMC736-18-01 AB & AMC Fire Alarm System Testing and Maintenance Bidder Name: Bidder must provide a minimum of 3 references. Company Name: Contact Person: Address: Telephone Number: City, State, Zip: E-mail Address: Services Provided / Date(s) of Service: Company Name: Address: City, State, Zip: Services Provided / Date(s) of Service: Contact Person: Telephone Number: E-mail Address: Company Name: Address: City, State, Zip: Services Provided / Date(s) of Service: Contact Person: Telephone Number: E-mail Address: Company Name: Address: City, State, Zip: Services Provided / Date(s) of Service: Contact Person: Telephone Number: E-mail Address: Company Name: Address: City, State, Zip: Services Provided / Date(s) of Service: Contact Person: Telephone Number: E-mail Address: Exhibit A RFP No. FMC736-18-01 RFP 08/28/16 Page 9

Bidder Name: EXCEPTIONS, CLARIFICATIONS, AMENDMENTS RFP No. FMC736-18-01 - AB & AMC Fire Alarm System Testing and Maintenance List below requests for clarifications, exceptions, and amendments, if any, to the RFP and associated RFP Documents, and submit with bidder s RFP response. The District is under no obligation to accept any exceptions and such exceptions may be a basis for RFP response disqualification. Reference to: Page No. Section Item No. Description p. 23 D 1.c. Bidder takes exception to *Print additional pages as necessary Exhibit A RFP No. FMC736-18-01 RFP 08/28/16 Page 10