HVACR Refrigeration

Similar documents
HVACR Commercial Refrigeration

HVACR Hydronic & Steam Systems

Course Outline. TERM EFFECTIVE: Spring 2018 CURRICULUM APPROVAL DATE: 10/23/2017

JEFFERSON COLLEGE COURSE SYLLABUS HRA125 REFRIGERATION AND A/C MECHANICAL SYSTEMS. 5 Credit Hours. Prepared by William Kaune November 30, 2010

Soil Fertility & Fertilizers

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT HVAC MAINTENANCE TECHNOLOGY. Test Code: 5937 Version: 01

HEATING, AIR CONDITIONING AND REFRIGERATION TECHNOLOGY COURSE SYLLABUS

Fundamentals of HVAC/R 2010

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Fire Investigation

power Describe the purpose of lockout/tag-out devices Demonstrate use of lockout/tagout

HEATING, AIR CONDITIONING & REFRIGERATION TECHNOLOGY DEPARTMENT COURSE SYLLABUS

HVA 220 COMMERCIAL AND DOMESTIC REFRIGERATION

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Installation 50% Service 20% Components 20% Applied Knowledge 10%

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

NZQA Expiring unit standard 3397 version 4 Page 1 of 5. Convert an automotive air conditioning system from R-12 to R-134a

B. A. T. Basic Appliance Training

Heating, Air Conditioning, Ventilation and Refrigeration Maintenance Technology/Technician CIP Task Grid

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs

HVAC-201. Syllabus. Prerequisites: HVAC-101and R-410a Safety Course (The R-410a Safety course may be completed while enrolled in HVAC201)

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Revised April High School Graduation Years 2016, 2017, and Unit/Standard Number

Chapter 6. Do s & Don ts in Refrigeration & Air-Conditioning Servicing

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

EXHIBIT G REFRIGERANT MANAGEMENT POLICY

Event #1 Brazing. In this event you will demonstrate how to:

Residential Piping and Long Line Guideline

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

HEATING, VENTILATION, AIR CONDITIONING

Grades Prentice Hall. Fundamentals of HVAC/R HVACR High School ISBN's SE / IG Grades 9-12

The Essentials Of Working With R-410A

Refrigeration Technology in Building Services Engineering

Certification Information. Qualifications. Test Specifications

Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC/R)

R-407A R-448A R-449A

Experienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning

Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

REFRIGERATION AND AIR CONDITIONING RÉFRIGÉRATION ET CLIMATISATION POST-SECONDARY NIVEAU POSTSECONDAIRE

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

Air Conditioning Repairs: Maintenance Required

Aspects of the. Following these key guidelines during a compressor changeout can ensure a successful, more efficient replacement.

Refrigerant changeover guidelines

R-290 SERVICE MANUAL SWF MODELS. Principals and Best Practices for servicing HC refrigeration equipment

SECTION 2 SAFETY, TOOLS & EQUIPMENT, SHOP PRACTICES UNIT 8 SYSTEM EVACUATION

DIABLO VALLEY COLLEGE CATALOG

ENVIRONMENTALLY SAFE R-410A SERVICE TECHNIQUES

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

HVA 140 RESIDENTIAL HEATING

OPERATING INSTRUCTIONS

RSES SERVICE APPLICATION MANUAL TABLE OF CONTENTS AUGUST 2016

JEFFERSON COLLEGE COURSE SYLLABUS HRA 249 COMMERCIAL REFRIGERATION SYSTEMS. 5 Credit Hours. Prepared by: William Kaune November 30, 2010

ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290

OPERATING INSTRUCTIONS

Refrigerant Recovery Unit, Model RRU134

Withlacoochee Technical College Syllabus Air-Conditioning, Refrigeration and Heating Technology HVAC / R

Air Conditioning Operation and Troubleshooting Matt Dunham

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

Entry Level Assessment Blueprint Heating, Ventilation, Air Conditioning & Refrigeration (HVAC/R)

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

COURSE OUTLINE. Course Title Automotive Air Conditioning. Co- or Pre-requisite AUT 110 and AUT 111

AUTOMOTIVE HEATING AND

HVAC Workshop â Air Conditioning & Boilers

Vacuum Gauge. Measures lower-than-atmospheric pressure Digital scales. microns psi in. Hg millibars pascals torr millitorr

APPLICATION & SERVICE GUIDE

10/4/2013. The Changing State of Refrigerants

ONLINE REGISTRATION: > Commercial > Products & Systems > Education & Training > Training - Class Finder > Filter State: Indiana OR CALL

Guidance. Service of Hydrocarbon Refrigerant Equipment in a Retail Environment

MASS. MARITIME ACADEMY

WineZone Ceiling Mount Ductless Split 15

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M

Entry Level Assessment Blueprint Heating, Ventilation and Air Conditioning (HVAC)

Air Conditioning and Refrigeration

INSTALLATION GUIDE. 4AC 14* ASA1 SERIES R-410a CONDENSING UNITS R-410A ATTENTION, INSTALLER! ATTENTION, USER!

INSTALLATION INSTRUCTIONS

ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290

Under Section 608 of the CAA, EPA has established regulations (40 CFR Part 82, Subpart F) that:

Condensing Unit Installation and Operating Instructions

Heating, Ventilation & Air Conditioning (HVAC)

COURSE NUMBER COURSE NAME COURSE DESCRIPTION

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

Installation Instructions

A/C Refrigerant. Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car

SYLLABUS. DIVISION: Business & Engineering Technologies REVISED: Spring CURRICULA IN WHICH COURSE IS TAUGHT: Automotive Analysis and Repair

INSTALLATION INSTRUCTIONS

UEE11 Electrotechnology. Training Package. UEENEEJ108A Recover, pressure test, evacuate, charge and leak test refrigerants SAMPLE.

REFRIGERANT CHANGEOVER

LENNDX INSTALLATION INSTRUCTIONS. IIlIIIIIIIIIIIIIIIIIIIIIIIHI A, WARNING A, WARNING WARNING RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

Heating, Ventilation, and Air Conditioning Instructional Framework

Refrigeration Training System

Gary Parker Refrigerants Product Manager

Transcription:

Western Technical College 10601101 HVACR Refrigeration Course Outcome Summary Course Information Description Career Cluster Instructional Level Total Credits 4.00 Total Hours 108.00 This course is an introduction to basic refrigeration systems. Topics include terminology, the refrigeration cycle, safety, refrigerants, lubricants, and environmental issues. The learner will assemble copper tubing, use hand tools, and use test instruments. The learner will operate, evacuate, charge and repair basic refrigeration units. HVACR is a common reference to Heating, Ventilation, Air Conditioning and Refrigeration. Architecture and Construction Associate Degree Courses Types of Instruction Instruction Type Lecture Lab Credits/Hours 2 CR / 36 HR 2 CR / 72 HR Course History Last Approval Date 5/17/2012 Purpose/Goals Prepare students to be successful working with refrigeration systems and refrigeration service equipment. Target Population Learners need a high school diploma and interest in the Heating, Ventilating, Air Conditioning, and Refrigeration field. Mechanical and/or electrical skills are a plus. Textbooks Heating, Ventilation, and Air Conditioning: A Residential and Light Commercial Text and Lab Book. 2nd Edition. Copyright 2006. Johnson, Cecil. Publisher: Cengage Learning. ISBN-13:978-1-4018-8472-7. Required. Course Outcome Summary - Page 1 of 10

Refrigeration and Air Conditioning Technology. 7th Edition. Copyright 2013. Whitman, Bill, Bill Johnson, John Tomczyk, and Eugene Silberstein. Publisher: Cengage Learning. ISBN-13:978-1-111-64447-5. Required. Refrigeration and Air Conditioning Technology - Study Guide/Lab Manual. 7th Edition. Copyright 2013. Whitman, Bill, Bill Johnson, John Tomczyk, and Eugene Silberstein. Publisher: Cengage Learning. ISBN- 13:978-1-111-64448-2. Required. Learner Supplies Safety glasses with side eye protection that meet Z87 OSHA guidelines. Vendor: Campus Shop. Required. Core Abilities 1. Apply mathematical concepts. 2. 3. Demonstrate ability to value self and work ethically with others in a diverse population. 4. Make decisions that incorporate the importance of sustainability. 5. Transfer social and natural science theories into practical applications. 6. Use effective communication skills. 7. Use technology effectively. Program Outcomes 1. Install HVACR systems. Summative 1.1. Student Exhibition of Proficiency/Performance tasks 1.1. Learner completes performance tasks with minimum accuracy of 80%. 2. Summative 2.1. Student Exhibition of Proficiency/Performance tasks 2.1. Learner completes performance tasks with minimum accuracy of 80%. Course Outcome Summary - Page 2 of 10

3. Summative 3.1. Student Exhibition of Proficiency/ Performance tasks 3.1. Learner completes performance tasks with minimum accuracy of 80%. 4. Troubleshoot HVACR systems. Summative 4.1. Student Exhibition of Proficiency/Performance tasks 4.1. Learner completes performance tasks with minimum accuracy of 80%. 5. Analyze HVACR systems. Summative 5.1. Portfolio 5.1. Projects show a minimum accuracy of 80% based on project rubric. 6. Evaluate HVACR system designs. Summative 6.1. Student Exhibition of Proficiency/Performance tasks 6.1. Learner completes performance tasks with minimum accuracy of 80%. Course Competencies 1. Adhere to (cultivate) and practice shop safety Domain Affective Level Organizing Use effective communication skills. 1.1. Skill Demonstration 1.1. you wear proper lab clothes. 1.2. you practice eye protection safety. 1.3. you respect other student's space and projects. 1.4. you handle chemicals and tools with appropriate caution. 1.a. Analyze the operation, rules, and safety requirements of the school and the class. Course Outcome Summary - Page 3 of 10

1.b. 1.c. 1.d. Articulate and practice personal safety and work habits. Apply safety practices handling hazardous substances including, gas, oxygen, acetylene, nitrogen, oil, refrigerant, cleaning fluids, acids and sanitizing fluids. Use safe practices when working with pressurized vessels. 2. Draw the basic refrigeration cycle Domain Cognitive Level Knowledge Analyze HVACR systems. 2.1. Drawing/Illustration 2.2. Written Product 2.1. you show the basic refrigeration components in their proper place in the system in a drawing. 2.2. you label the refrigerant lines (discharge, liquid, and suction) and direction of flow. 2.3. you propose reasonable discharge and suction pressures for an application and a specific refrigerant. 2.4. you show superheat and subcooling representations in their proper place. 2.a. Be introduced to the theory of refrigeration. 2.b. Be introduced to the theory of fluids and pressures related to refrigeration. 2.c. Discriminate between the relationship of the system components as compared to the refrigeration cycle. 2.d. Diagram a basic refrigeration system. 2.e. Describe the basic refrigeration system. 3. Diagram the function of the main components of a refrigeration system Domain Cognitive Level Analysis Transfer social and natural science theories into practical applications. Analyze HVACR systems. 3.1. Drawing/Illustration 3.2. Written Product 3.3. Written Objective Test 3.1. you diagram the basic refrigeration system. 3.2. you lsit the main components of a basic refrigeration system. 3.3. you explain the function of the basic refrigeration system components. 3.4. you identify the inter-connecting piping between the basic refrigeration system components. 3.a. Classify the various types of metering devices and know their operation. 3.b. Classify the various types of evaporaters and know their operation. 3.c. Classify the various types of compressors and know their operation. 3.d. Classify the various types of condensers and know their operation. 4. Use HVACR related tools and instruments Domain Psychomotor Level Practice Course Outcome Summary - Page 4 of 10

Troubleshoot HVACR systems. 4.1. Demonstration 4.2. Project 4.1. you cut and ream copper tubes for projects. 4.2. you use a swagging tool for connecting two tubes. 4.3. You flare copper tubing for projects 4.4. you complete a bending project using a tube bender. 4.5. you complete a flaring project 4.6. you complete a soldering, brazing, flaring, and bending project. 4.7. You leak test fittings with R-22 trace gas and nitrogen 4.8. You identify leaks with various electronic leak detectors and pinpoint leaks with soap suds. 4.a. Use hand tools common to the HVACR trade. 4.b. Use field approved pipe cleaning methods. 4.c. Use a Nitrogen cylinder and adjust the regulator. 4.d. Use leak detectors. 4.e. Use assorted micron gauges 5. Operate hand held propane, air acetylene and oxygen acetylene torches safely as per manufactures recommendations. Domain Cognitive Level Applying Status Pending Approval 5.1. Skill Demonstration 5.1. Show proper set up and shutdown procedures. 5.2. Demonstrate regulator replacement and leak checking of tank and hose fittings. 5.3. Demonstrate proper pressure regulator adjustments to manufactures recommendations. 5.4. Adjust flame to neutral flame. 5.5. Demonstrate proper torch, regulator and tank shutdown procedures 6. Assemble copper piping Domain Psychomotor Level Imitation 6.1. Skill Demonstration 6.1. you use oxygen / acetylene equipment to solder and braze. 6.2. you use air acetylene equipment to solder and braze. Course Outcome Summary - Page 5 of 10

6.3. you use propane-air equipment to solder and braze. 6.4. you use silfos, soft solder, and silver solder to connect tubbing. 6.a. Use various torches. 6.b. Distinguish between soldering and brazing. 6.c. Use various hand tools. 6.d. Construct copper tubing tasks. 7. Acquaint self with federal and local codes and standards Domain Affective Level Responding Analyze HVACR systems. 7.1. Written Objective Test 7.1. you observe federal, state, and local refrigerant rules. 7.2. you observe federal, state, and local electrical rules. 7.3. you observe federal, state, and local mechanical rules. 7.4. you observe federal, state, and local safety rules. 7.a. Analyze regulations affecting ozone depletion. 7.b. Analyze regulations affecting global warming. 8. Describe and practice (utilize) safe refrigerant handling Domain Cognitive Level Knowledge Transfer social and natural science theories into practical applications. Use effective communication skills. 8.1. Demonstration 8.2. Written Product 8.1. you identify refrigerants by ARI color code and ASHRAErefrigerant number. 8.2. you classify refrigerants into their ASHRAE designated safety group. 8.3. you use refrigerantion equipment without venting excess refrigerant. 8.4. you select proper replacement refrigerants. 8.a. Follow proper refrigerant handling procedures. 8.b. Analyze regulations affecting ozone depletion. 9. Install a refrigeration gauge manifold set on to a fully operational refrigeration system. Domain Cognitive Level Applying Status Pending Approval Course Outcome Summary - Page 6 of 10

9.1. Skill Demonstration 9.1. You will identify high and low side hoses on the manifold set. 9.2. You will identify the service hose of the manifold set. 9.3. You will install gauges on systems with service valves and schraeder valves. 9.4. you will purge the gauge hoses. 9.5. You will remove the gauges with minimal refrigerant loss. 10. Practice a complete start-up, checkout, and test operation of a refrigeration system Domain Cognitive Level Applying Transfer social and natural science theories into practical applications. Use technology effectively. Analyze HVACR systems. 10.1. Skill Demonstration 10.1. you monitor pull down to the prescribed operating conditions. 10.2. you compare compressor full load current with actual measurements. 10.3. you measure and record low and high side pressures. 10.4. you measure, calculate and record system superheat and subcooling. 10.5. you accurately measure and record temperature drop across both the evapotater and condenser coils 10.a. Know the function and operation of various access fittings. 10.b. Determine the temperature of a refrigerant given its corresponding pressure. 10.c. Calculate the typical operating conditions of a refrigeration and / or air conditioning system. 10.d. Calculate superheat. 10.e. Calculate subcooling. 10.f. Evaluate amp draws of system loads. 11. Complete refrigerant recovery, system evacuation, system charging, and operational checks of a basic refrigeration system. Domain Affective Level Organizing Use technology effectively. 11.1. Skill Demonstration 11.1. you select proper recovery machine and recovery tank according to the refrigerant type. 11.2. you connect equipment, gauges, recovery machine, and recovery tank for liquid recovery and/or for Course Outcome Summary - Page 7 of 10

vapor recovery. 11.3. you recover the refrigerant to the required degree according to the EPA and Wisconsin codes. 11.4. you terminate the recovery process with minimum losses and store or dispense with refrigerant as needed. 11.a. Identify regulations affecting ozone depletion. 11.b. Differenciate between various refrigerant recovery, recycling, and reclamation methods. 11.c. Plan refrigerant recovery safety. 11.d. Use refrigerant recovery equipment. 11.e. Describe alternative refrigerant retrofits. 12. Determine different types of lubricants with specific refrigerant types. Domain Cognitive Level Applying 12.1. Skill Demonstration 12.1. you characterize mineral, alkylbenzene, and polyolester oils. 12.2. you remove and replace the proper amount of the indicated oil in a system. 12.3. you use a refractory meter to identify types of oil. 12.4. you replace mineral oil with a suitable substitute according to the refrigerant type. 12.5. you replace alklebenzene oil with polyolester measuring percentages according to manufacturers conditions. 12.6. you pump down a basic refrigeration unit. 12.a. Change compressor oil using proper replacement procedures. 12.b. Select lubricants for refrigerant retrofits. 12.c. Analyze oil condition and type. 13. Differentiate between refrigerants and understand refrigerant retrofit options. Domain Cognitive Level Analyzing 13.1. Written Product 13.1. you select refrigerant cylinders according to their color codes. 13.2. you replace a refrigerant with a suitable substitute. 13.3. you identify refrigerants according to their pressure range. 13.4. you associate temperature ranges with refrigerants that are appropriate. 13.a. Differentiate between CFC's, HCFC's, HFC's, and HC's. Course Outcome Summary - Page 8 of 10

13.b. Discuss popular refrigerants. 13.c. Discuss refrigerant blends. 13.d. Discuss refrigerant applications. 14. Troubleshoot a complete refrigeration system and perform problem analysis Domain Cognitive Level Analyzing Use technology effectively. Troubleshoot HVACR systems. 14.1. Skill Demonstration 14.2. Written Product 14.1. you diagnose a basic refrigeration system using a logical step procedure. 14.2. you analyze electrical conditions and compare to normal or expected results. 14.3. you analyze refrigerant pressures and temperatures and compare to normal or expected results. 14.4. you properly use diagnostic tools to collect data. 14.a. Solve mechanical system problems. 14.b. Understand basic refrigeration maintenance programs. 14.c. Recover refrigerant from a basic refrigeration unit. 14.d. Charge a basic refrigeration unit by the sight glass method. 14.e. Charge a basic refrigeration unit by the weight method. 14.f. Monitor compressor amp draw and compare to nameplate data. 15. Familiarization of a window air conditioner. Domain Cognitive Level Understandin g 15.1. Critique Status Pending Approval Performance will meet expectations when: 15.1. you will analyze unit construction 15.2. you will determine motor type, amperage and voltage. 15.3. you will recover refrigerant from the unit and weigh in the correct charge. 15.4. you will monitor pressures, temperatures and amps to determine if the unit is operating as designed. 15.a. demonstrate understanding of unit construction. 15.b. recover refrigerant to proper EPA required vacuum level. 15.c. charge unit to namelplate requirement. 15.d. evaluate unit performance as compared to manufactures specifications. 16. Replace a hermetic compressor. Domain Cognitive Level Applying Status Pending Approval 16.1. Skill Demonstration Course Outcome Summary - Page 9 of 10

Performance will be satisfactory when: 16.1. you will recover refrigerant from a window air conditioner. 16.2. you will remove the compressor from the system. 16.3. you will replace the filter drier. 16.4. you will leak test the system. 16.5. you will evacuate the system to 500 microns. 16.6. you will charge the unit to nameplate data. 16.7. you will evaluate system performance as compared to manufactures specifications. 16.a. recover refrigerant to EPA required vacuum level. 16.b. remove and replace compressor according to manufactures specifications. 16.c. leak test the system. 16.d. evacuate the system to 500 microns. 16.e. evaluate the system Course Outcome Summary - Page 10 of 10