Split Type Air Conditioners

Similar documents
Split Type Air Conditioners

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

Lineup of DC Inverter Air Conditioners with R-32 Refrigerant

A wider lineup of DC Inverter and Non-Inverter air conditioners with 19 models is currently available. You can choose whichever that fits your

PCR0709A. Options. Indoor unit

Inverter Wall Mounted

CHI NHAÙNH HAØ NOÄI Taàng 12, toøa nhaø Ocean Park Tower, 1 Ñaøo Duy Anh, Quaän Ñoáng Ña, Haø Noäi

Inverter Wall Mounted

The Comfort and Luxury You Deserve

Inverter Wall Mounted

w w w. d a i k i n. e u ATXS-E

Daikin air conditioners for your home

The World s No.1 Heat Pump Company HEATING AND COOLING SOLUTIONS SUPER MULTI NX MULTI-SPLIT AIR CONDITIONERS DC INVERTER CONTROL

for your home FTYN-GX FT(Y)N-F

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only

PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V

LV Series. SEER 20+ Wall Mount Heat Pump

The Comfort and Luxury You Deserve

Daikin air conditioners for your home

BENEFIT FROM LOWER FUEL COSTS.

Daikin air conditioners for your home

Inverter Wall Mounted Series

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps. FTXS-G

MULTI SYSTEM TECHNOLOGY. 1. Ururu Humidification PART 2 - URURU MULTI

for your home FTXS-G WALL MOUNTED UNIT

The Comfort and Luxury You Deserve

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

Up to SEER 26.1 Wall Mount Heat Pump

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

DAIKIN FAQ SERIES HEATING & COOLING SYSTEMS. INDOOR WALL-MOUNTED UNITS Up to 18.6 SEER / Up to 9.4 HSPF Up to 12.7 EER

DAIKIN Modular Inverter Air Cooled Chiller

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

DAIKIN S URURU SARARA

Remote Controller. <Open the front cover> <ARC452A4>

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU

DAIKIN FCQ SERIES HEATING & COOLING SYSTEMS. ROUNDFLOW CEILING-MOUNTED CASSETTE Up to 18.6 SEER / Up to 10.2 HSPF Up to 13.0 EER

About Daikin: WARNINGS:

Air conditioners Heating & Cooling

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Air conditioners Heating & Cooling

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

Air Conditioners. Technical Data FTXS-G

Now with WiFi as standard Find out more at

Pure comfort & design

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

FAQ. Wall Mount Heat Pump or Cooling Only

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

Pure comfort & design

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump

Pure comfort & design

Pure comfort & design

LIFESTYLE R A NGE W A L L M O U N T E D N EW STYLISH, SLIM AN D ELEGANT 5 YEAR F U LL P A R TS & LABOUR W A RRANTY

Split Type Air Conditioners DC Inverter Power Control Heat Pump [50 Hz]

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

Daikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

The Comfort and Luxury You D eserve

PCRAU0726F. Multi-Split Type Air Conditioners L Series with DC Inverter Power Control Cooling Only & Heat Pump [50 Hz]

DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

QUATERNITY SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

HEAT PUMPS BY DAIKIN. Energy efficient heating and cooling solutions for your home

Cooling Only & Heat Pump

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

RC-0219-A. Single-Split Non Inverter Series

Split System Air Conditioning

for your home FLXS-B Flexi type unit air to air heat pumps

Information for end users. Wall mounted units. Total comfort at home

Owner's Manual TABLE OF CONTENTS

HEAT & COOL MODEL (REVERSE CYCLE)

. Creating Maximum Comfort

Service Manual. Inverter Pair Floor Standing Type K-Series. Draft. SiBE [Applied Models] Inverter Pair : Heat Pump

AIR CONDITIONERS LINE-UP

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Consumer Guide. Split System: Wall Mounted Inverter Heat Pumps

LV Series. SEER 15+ Concealed Built in Heat Pump

Daikin 19 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

AIR CONDITIONERS, HEATING & COOLING for your home

PLXSID1605. Warning HEAD OFFICE :

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

DESIGN & TECHNICAL MANUAL

SiBE041525F. Service Manual. Inverter Pair Wall Mounted Type FTX/ATX-K Series. [Applicable Models] Inverter Pair: Heat Pump

DAIKIN EMURA. FORM. FUNCTION. REDEFINED. THE NEW INDOOR AIR CONDITIONING UNIT FROM DAIKIN.

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

Compact Cassette Type

SiUS181631EA. Service Manual. Multi-Split Type Air Conditioners RMXS-L Series. [Applied Models] Inverter Multi : Heat Pump

Transcription:

PCRMT1448Baprv Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the user s manual carefully before using this product. The user s manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Split Type Air Conditioners DC Inverter Control 50/60 Hz Urusara 7 FTKJ Series FTKV Series Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. FTKC Series Urusara 7 FTKJ Series Specifications, designs and other content appearing in this brochure are current as of January 2016 but subject to change without notice. c All rights reserved PC

Lineup of DC Inverter Air Conditio ners with R-32 Refrigerant Daikin is the sole manufacturer to produce both air conditioning equipment and refrigerants worldwide. Our cutting-edge technologies and use of advanced R-32 refrigerant provide enhanced comfort while reducing the impact on climate change. 1.5 Class 2.0 Class 2.5 Class 3.5 Class 5.0 Class 6.0 Class 7.1 Class Urusara 7 FTXZ25NVM FTXZ35NVM FTXZ50NVM FTKJ Series FTKJ25NVMW (white) FTKJ35NVMW (white) FTKJ50NVMW (white) FTKJ25NVMS (silver) FTKJ35NVMS (silver) FTKJ50NVMS (silver) FTKV Series FTKV25NVM FTKV35NVM FTKV50NVM FTKV60NVM FTKV71NVM FTKC Series NEW NEW NEW NEW NEW NEW FTKC15PVM FTKC20PVM FTKC25QVM FTKC35QVM FTKC50QVM FTKC60QVM FTKC71QVM NEW indicates a model with a new design. NEW indicates a model with a new capacity class. 1 2

Urusara 7 A New Kind of Cool Urusara 7 puts the latest Japanese air conditioning technology at your fingertips, offering a unique, total comfort experience for any lifestyle. Powerful year-round cooling and dehumidifying are just the beginning. Urusara 7 is also the world s first air conditioner to use next-generation R-32 refrigerant 1. Along with its many energy-saving features, this higher performance refrigerant gives Urusara 7 unrivalled energy efficiency 2. Features Redesigned air intake and heat exchanger World-first 3 humidity control technology Precision circulation airflow Reliable streamer discharge air purification Convenient automatic filter cleaning system Innovative design with Japanese aesthetic Remote control via smartphone (optional adaptor) Category: Product Design 2013 Notes: 1. This is for residential-use wall-mounted type air conditioners as of November 2012, when Daikin launched Urusara 7 in the Japanese market. 2. In January 2013, the 4.0 to 7.1 class models for the Japanese market received the Minister s Prize from Japan s Ministry of Economy, Trade and Industry in the Fiscal 2012 Grand Prizes for Excellence in Energy Efficiency and Conservation. 3. As of 1999, when Daikin launched Ururu Sarara in the residential-use air conditioner market. 3 4

FTKJ Series Form. Function. Design. Sleek Europiean style of FTKJ series proves once again that design is everything. Yet this elegant body also houses cutting-edge smart technology which provides outstanding comfort and performance in any situation. The series also delivers Daikin s well-known energy efficiency, thanks to features such as its redesigned swing compressors. This versatile system truly is a total solution for designers, architects and home-owners alike. Features Energy-saving COP of 3.59 to 4.81 Stylish finish in eye-pleasing colours Wide selection of comfort technologies Whisper quiet sound level Remote control via smartphone (optional adaptor) White Silver Category: Product Design 2014 5 6

Urusara 7 Heat Pump FTXZ25/35/50 Contents of FTKV and FTKC Series Model name Indoor unit FTXZ25 FTXZ35 FTXZ50 Outdoor unit RXZ25 RXZ35 RXZ50 Capacity Cooling Heating 2.45 (0.6-3.9) 3.45 (0.6-5.3) 4.95 (0.6-5.8) 8,400 (2,000-13,300) 11,800 (2,000-18,100) 16,900 (2,000-19,800) 3.6 (0.6-7.5) 5.0 (0.6-9.0) 6.3 (0.6-9.4) 12,300 (2,000-25,600) 17,100 (2,000-30,700) 21,500 (2,000-32,100) P9 It s Time for DC Inverter P23 Choice of Wide Range of Airflow Patterns Power consumption Indoor unit Cooling Heating W 430 (110-880) 680 (110-1,330) 1,150 (110-1,600) 620 (100-2,010) 1,000 (100-2,530) 1,410 (100-2,640) FTXZ25 FTXZ35 FTXZ50 P11 P13 Lineup of FTKV Series Lineup of FTKC Series P25 Quiet Nights in Your Neighbourhood Dimensions (H W D) 295 798 370 Outdoor unit RXZ25 RXZ35 RXZ50 Dimensions (H W D) 595 795 300 Solar radiation Greenhouse gas See the Urusara 7 catalogue for details. P15 Infrared radiation Sea Land Next Generation R-32 Refrigerant P27 Set and Forget On/Off Operation FTKJ Series Cooling Only FTKJ25/35/50 (white) FTKJ25/35/50 (silver) Model name Indoor unit Outdoor unit FTKJ25 (white) FTKJ35 (white) FTKJ50 (white) FTKJ25 (silver) FTKJ35 (silver) FTKJ50 (silver) RKJ25 RKJ35 RKJ50 P17 Inverter Air Conditioners Reduce Electricity Consumption P29 Photocatalytic Air Purifying Cooling capacity 2.5 2.45 (1.2-3.4) (0.6-3.9) 3.45 3.5 (1.3-4.1) (0.6-5.3) 4.95 5.2 (1.7-5.5) (0.6-5.8) 8,500 (4,100-11,600) 11,900 (4,400-14,000) 17,700 (5,800-18,800) Power consumption W 520 855 1,450 Indoor unit FTKJ25 (white) FTKJ35 (white) FTKJ50 (white) FTKJ25 (silver) FTKJ35 (silver) FTKJ50 (silver) P19 All Models Feature High Energy Efficiencies P31 Remote Control via Smartphone Dimensions (H W D) Outdoor unit Dimensions (H W D) See the FTKJ series catalogue for details. 303 x 998 x 212 RKJ25 RKJ35 RKJ50 550 x 765 x 285 735 x 825 x 300 P21 Less Wasted Energy with Infrared Sensors P33 Function List of FTKV and FTKC Series P35 Functions P37 Wireless Remote Controller P39 Specifications for FTKV Series P40 Options for FTKV Series P41 Specifications for FTKC Series Options for FTKC Series

FTKV and FTKC Series It s Time for DC Inverter Inverter air conditioners are well known for their precise control. In fact, their outstanding efficiency can cut energy bills compared to non-inverter models. This precision also means greater comfort, plus full power at the touch of a button. With its strong environmental coitment, Daikin has been using its market-leading position to promote inverter systems worldwide. DC Inverter models feature advanced DC motors. These motors use high-power magnets to generate rotation, giving them greater efficiency than AC motors. Features Improved performance over non-inverter models Optimal control with Intelligent Eye and Econo Mode Advanced comfort features including 3D Airflow Greater convenience with weekly scheduling Titanium Apatite Photocatalytic Air-Purifying Filter Remote control via smartphone (optional adaptor) FTKV25/35 The FTKC series feature Daikin s new smile curve design for the front panel. The smile curve creates a stylish, modern appearance which blends easily with any interior decor. FTKC25/35

Lineup of FTKV Series FTKV Series Cooling Only FTKV25/35NVM RKV25/35NVM 2.5 Class FTKV25NVM / RKV25NVM 2.5 (1.2-3.4) 8,500 (4,100-11,600) 3.5 Class FTKV35NVM / RKV35NVM 3.5 (1.3-4.1) 11,900 (4,400-14,000) FTKV50/60NVM FTKV71NVM RKV50/60NVM RKV71NVM 5.0 Class FTKV50NVM / RKV50NVM 5.2 (1.7-6.0) 17,700 (5,800-20,500) 6.0 Class FTKV60NVM / RKV60NVM 6.0 (1.9-7.0) 20,500 (6,500-23,900) 7.1 Class FTKV71NVM / RKV71NVM 7.1 (2.3-8.9) 24,200 (7,800-30,400) 11 12

Lineup of FTKC Series FTKC Series Cooling Only FTKC15/20PVM RKC15/20PVM 1.5 Class FTKC15PVM / RKC15PVM 1.5 (0.75-1.9) 5,100 (2,500-6,500) 2.0 Class FTKC20PVM / RKC20PVM 2.0 (1.0-2.4) 6,800 (3,400-8,200) NEW NEW FTKC25/35QVM FTKC50/60/71QVM RKC25/35QVM 2.5 Class FTKC25QVM / RKC25QVM 2.5 (1.0-3.4) 8,500 (3,400-11,600) 3.5 Class FTKC35QVM / RKC35QVM 3.5 (1.3-4.1) 11,900 (4,400-14,000) RKC50/60/71QVM NEW 5.0 Class FTKC50QVM / RKC50QVM 7.1 Class FTKC71QVM / RKC71QVM 5.2 (1.4-6.0) 17,700 (4,800-20,500) 6.0 Class FTKC60QVM / RKC60QVM 6.0 (1.4-6.7) 20,500 (4,800-22,900) 7.1 (2.1-7.5) 24,200 (7,200-25,600) NEW indicates a model with a new design. NEW indicates a model with a new capacity class. 13 14

Next-Generation R-32 Refrig erant ming As the sole worldwide manufacturer of both air conditioning equipment and refrigerants, Daikin is continuously researching refrigerants as well as new technologies that can reduce energy consumption. Use of refrigerants with a lower impact on global warming is urgently required as climate change has become one of the most critical global issues. Daikin has now adopted R-32. This next-generation refrigerant does not deplete the ozone layer and has a lower impact on global warming. Zero Ozone Layer Depletion The ozone layer surrounds the Earth and helps to absorb the harmful ultraviolet rays in sunlight. Although R-22 (HCFC) refrigerant had been used in air conditioners and refrigerators, it damages the ozone layer and its use is to be mostly eliminated by 2020. To replace R-22, Taiwan, Japan and European countries with more progressive regulations selected R-410A (HFC). Refrigerant Ozone depletion potential Global warming potential 1 Less Impact on Global Warming The Earth retains solar heat in the daytime for warming and then releases this heat at night, allowing it to maintain an optimal temperature range. However, with greenhouse gases increasing, it is more difficult to discharge heat and the planet is gradually becoming warmer. This is called global warming. R-32 has only around 30% of the global warming potential of R-410A and R-22. Greenhouse gas Infrared radiation Sea Land Solar radiation Greenhouse gases cause damage which allows solar radiation to pass through the Earth s outer atmosphere while also trapping infrared radiation. These gases rapidly increase and interfere with the Earth s ability to release heat into space, causing the ambient temperature to rise. 2,500 2,000 1,500 1,000 500 675 R-22 Global Warming Potential 1 R-410A R-32 0.05 0 0 1,810 2,090 675 2,090 1,810 R-32 R-410A R-22 Increased Energy Efficiency The potential refrigerating effect of R-32 is 1.5 times that of R-410A. Thus the piping diameter can be smaller. Refrigeration Cycle of R-32 Pressure (kpa) 3,500 3,100 2,700 2,300 1,900 1,500 1,100 700 Te/Tc=12/43 C SH/SC=6/6 C 300 200 300 400 500 600 Refrigerants: Heat Release in Air Conditioning Systems Similar Mechanism to Human Body An air conditioner functions in a surprisingly similar way to the human body. In the body, blood carries heat as it circulates and helps to release excess heat through sweating. Refrigerant also carries heat and helps to adjust temperature through heat exchange. R-410A refrigerating effect R-22 refrigerating effect R-32 refrigerating effect, 1.5 times that of R-22 or R-410A Enthalpy (kj/kg) Effective Release of Heat Refrigerant is changed from gas to liquid in the outdoor heat exchanger, after which it is evaporated in the indoor heat exchanger. During cooling operation, cool air is discharged from the indoor unit while heat is removed from the air taken in from inside the room. This heat is delivered to the outdoor unit and released. R-32 R-410A R-22 Refrigerant Flow during Cooling Note: 1. Global warming potential values are based on the Fourth Assessment Report from the Intergovernmental Panel on Climate Change (IPCC). 15 16

Inverter Air Conditioners Reduce Electricity Consumption Lower Electricity Consumption Powerful and Energy Saving Inverters are devices that are able to vary their capacity by adjusting operating frequency. This allows inverter air conditioners to cut electricity use compared to non-inverter models. An inverter system can help to noticeably reduce household power bills. If you select Auto Fan Speed, your inverter air conditioner will operate at maximum efficiency without any further setting. It will not start and stop its compressor to maintain the room temperature. You can also go out of the room for a short time without any worries. FTKV50NVM Inverter models operate at maximum capacity (100% load) to quickly reach the set temperature. They then reduce operation to low capacity (partial load), which is sufficient to maintain the set temperature. This allows inverter models to operate at low capacity (partial load) most of the time. Comfortable FTKV50NVM Capacity Maximum capacity 6.0 Minimum capacity 1.7 Maximum capacity 6.0 High compressor rotation speed 100% load Medium capacity 3.85 Minimum capacity Medium compressor rotation speed Partial load 1.7 Slow compressor rotation speed, Partial load Comfortable Inverter models finely adjust their capacity according to the heat load, minimising the difference between the set temperature and room temperature. This ensures higher comfort levels than with non-inverter models. Time Temperature fluctuation during cooling operation Temp. No Starting and Stopping Small temp. difference Comfortable Not cool Non-inverter Inverter air conditioners vary their capacity by adjusting the rotation speed of their compressors. In contrast, non-inverter models have a fixed capacity and can only control the room temperature by starting or stopping their compressors. Inverter Non-inverter Rotations Controls rotation according to required power Large loss of electricity Set temp. Starts Too cool Inverter Time Time 17 18

All Models Feature High Ene rgy Efficiencies COPs of 3.55 to 4.63 The FTKV series achieves COPs of 3.55 to 4.63 thanks to Daikin s DC Inverter control and next-generation R-32 refrigerant. The FTKV25 achieves a COP of 4.63,13% higher than the conventional FTKS25. The FTKV35 achieves a COP of 3.85,16% higher than the conventional FTKS35. Daikin DC Inverter Technologies DC Inverter Control DC Inverter is Daikin s term for an inverter air conditioner equipped with a DC motor. These motors use magnets to generate rotation, making them more efficient than AC motors. Daikin has fitted its advanced DC motors for compressors and fan motors with powerful neodymium magnets to achieve even greater efficiency. It calls these devices Reluctance DC motors. New Conventional COP 3 4 5 FTKV25NVM 4.63 FTKS25GVMA 4.10 FTKV35NVM 3.85 FTKS35GVMA 3.31 Swing compressor Swing Compressor With its smooth rotation, the swing compressor significantly decreases friction and vibration. It also eliminates the leakage of refrigerant gas during compression. These advantages provide quiet and efficient operation. The high performance of this Daikin original technology was recognised in 1997 with the receipt of an award from the Japan Society for the Promotion of the Machine Industry 1. The compressor s reputation for reliability has grown considerably in the nearly 20 years since this award was presented. FTKV50NVM 4.00 FTKS50HVM 3.85 FTKV60NVM 3.80 FTKS60HVM 3.68 FTKV71NVM 3.55 FTKS71HVM 3.45 Reluctance DC motor Reluctance DC motor Neodymium magnet Magnetic power Reluctance DC Motor for Compressors The compressor is one of an air conditioner s core components and its performance is directly linked to the motor. Daikin was the first to successfully use a Reluctance DC motor with a scroll compressor in coercial-use air conditioners 2. It has now adapted this highefficiency motor for the swing compressors in its residential-use systems. The Reluctance DC motor saves energy by generating more power with a smaller electric current than AC or conventional DC motors. Rapid switching What Is COP? An air conditioner s COP (coefficient of performance) indicates how efficiently the unit uses energy. A higher COP means greater energy efficiency. It also means lower electricity consumption, and of course lower power bills. Capacity (W) COP = Power consumption (W) Electromagnet Repelling power Embedding high-strength neodymium magnets in the shaft turns the entire centre of the motor into a powerful magnet. By rapidly switching the poles of this electromagnet, the Reluctance DC motor is able to produce even greater speed and power. 19 Notes: 1. This marked the development of a high-performance swing compressor that was compatible with alternative fluorocarbons. 2. Daikin s achievement was recognised by the Institute of Electrical Engineers of Japan at the 54th Academic Promotion and Technical Development Awards in 1998. 20

Less Wasted Energy with Infra red Sensors Intelligent Eye Intelligent Eye prevents energy wastage by using its infrared sensors to detect human movement in a room. If there is no movement for 20 minutes, it automatically adjusts the set temperature by approximately 2 C. Once Intelligent Eye is turned on, it operates automatically without any further setting. This function is available for the FTKV series and FTKC25/35/50/60/71. Intelligent Eye indicator Intelligent Eye sensor Econo Mode This function limits the maximum power consumption. It helps to reduce power usage if the cooling load is high, for example, at startup or during large gatherings and periods of direct sunshine. Normal operation Power consumption Econo Mode Time Maximum capacity decreases during Econo Mode, requiring more time to reach the set temperature. If Intelligent Eye detects no movement for 20 minutes, it adjusts the set temperature by approximately 2 C. When a person enters the room, it automatically returns the temperature to the set level. Standby Electricity Saving Electrical appliances still use a surprising amount of power even when they are waiting in standby mode. Recognising this, Daikin has developed the Standby Electricity Saving function to reduce this hidden power consumption. This function is available for the FTKV50/60/71 and FTKC25/35/50/60/71. 21 22

Choice of Wide Range of Airfl ow Patterns Power-Airflow Flap and Power-Airflow Dual Flaps The Power-Airflow Flap and Power-Airflow Dual Flaps flatten out during cooling operation to deliver air to every part of a room. Selecting the low angle sends air right to the corners, while choosing the high angle spreads air around the centre. The Power-Airflow Flap is available for the FTKC15/20/25/35. The Power-Airflow Dual Flaps are available for the FTKV series and FTKC50/60/71. Wide-Angle Louvers The Wide-Angle Louvers provide effective airflow coverage no matter where the indoor unit is placed in a room. The louvers deliver cool air right to the corners of any space. The FTKV50/60/71 can be adjusted directly from the wireless remote controller. Other units can be set manually. The louvers cover even a spacious room. The angles of the louvers can be freely adjusted according to where people are in the room. If the indoor unit is not positioned in the centre of the wall, the louvers can be set to the left or right. When you choose the low angle, cool air slides off to reach the corners of the room. 3D Airflow Inverter Powerful Operation Inverter Powerful Operation boosts airflow to maximum volume for a 20 minute period. This function is convenient for quickly adjusting the indoor temperature to the set temperature. After 20 minutes, the unit automatically returns to its previous settings. 20 minutes 3D Airflow combines Vertical and Horizontal Auto-Swing to reduce indoor temperature fluctuation. This function circulates air to every part of a room for uniform cooling of even large spaces. To start 3D Airflow, push both the Vertical and Horizontal Auto-Swing buttons. The flaps and louvers swing in turn. This function is available for the FTKV50/60/71. 4 1 2 Comfort Airflow Mode Comfort Airflow Mode prevents uncomfortable drafts from blowing directly on to a person s body. During cooling operation, the flap moves upward to prevent cold drafts. This function is available for the FTKV50/60/71 and FTKC series. 3 The flaps and louvers swing in turn, expanding the comfort zone. 23 24

Quiet Nights in Your Neighbo urhood Indoor Unit Quiet Operation The FTKV and FTKC series give you a choice of 5-step, Quiet or Automatic settings for the fan speed. The Quiet setting selects Indoor Unit Quiet Operation, which decreases the sound pressure level by 3 to 6 db (A) below the Low setting. This wide range of settings allows you to precisely control the fan speed according to your needs. For example, the Quiet function will help you to sleep more comfortably at night. The sound pressure level is just 19 db (A) for the FTKC25. Outdoor Unit Quiet Operation This function decreases the sound pressure level by 3 to 7 db (A) below the rated operation. It provides a sound pressure level of 43 db (A) for the RKV25 and RKC50/60. Capacity may decrease when Outdoor Unit Quiet Operation is selected. This function is not available for the RKC15/20. FTKC25 Fan speed Fan speeds High (H) Low (L) Quiet (SL) Sound pressure level RKC60 19 db (A) is so quiet you can even hear whispers 1 Auto Operations (H) Quiet (SL) SL Low L Sound pressure levels 38 db (A) 25 db (A) 19 db (A) Each decrease in airflow volume reduces the sound pressure level. M Sound pressure levels 50 db (A) 43 db (A) 6 db (A) H High 7 db (A) 24 Hour On/Off Timer This timer can start or stop the air conditioner within a 24 hour period. It can be preset in 10 minute steps by pressing the On/Off Timer button on the wireless remote controller. The On Timer and Off Timer can be used in combination. This function is available for the FTKV series and FTKC15/20. Count Up-Down On/Off Timer The operation start and stop times can be set with the touch of a single button and preset for a period of one to 12 hours in one hour increments. When the Off Timer is set, Night Set Mode is activated automatically. This function is available for the FTKC25/35/50/60/71. Night Set Mode Pressing the Off timer button automatically selects Night Set Mode. This function prevents excessive cooling for a pleasant sleep. One hour after the Off timer button is pressed, the room temperature is raised by 0.5 C. OFF ON Off timer at 1:00 a.m. and On timer at 6:00 a.m. ON HR. OFF HR. Stops the unit after three hours and starts it again eight hours later. Indoor unit Outdoor unit 19 20 30 40 43 50 Rustling of leaves Pendulum of a wall clock Library Normal office (db (A)) Set temp. before Off timer begins to operate Time 60 minutes Off timer turns on +0.5 C Cooling operation: Room temperature is raised by 0.5 C after 60 minutes. Cooling Off timer stops air conditioner Note: 1. Based on Examples of Sound Pressure Levels, Ministry of the Environment, Japan, November 2002. 25 26

Set and Forget On/Off Opera tion Weekly Timer The Weekly Timer allows up to four actions to be prograed for each day of the week. It is possible to schedule not only the On and Off times but also to set temperatures. Once you set up the Weekly Timer, the air conditioner operates each day without controller input. The Weekly Timer synchronises the air conditioner with your family s schedule, greatly improving comfort in your home. This function is available for the FTKV50/60/71. Living room Monday to Friday Prograe 1 On 22ºC 6:30 a.m. Bedroom Monday to Friday Prograe 1 On 23ºC 11:30 p.m. If you set the Weekly Timer 30 minutes before your wake-up time, you can avoid the hot and humid morning air and enjoy a pleasantly cool room as you get up. Even if you go to bed at 0:00 a.m., the air conditioner will start operation 30 minutes before to help you fall into a comfortable sleep. Prograe 2 Off 8:00 a.m. Prograe 2 Off 3:00 a.m. The Weekly Timer will automatically stop operation after you leave home on a busy morning. You can forget about the air conditioner. Even if you go to bed at 0:00 a.m., the air conditioner will operate for another three hours so you continue to sleep comfortably. Stopping operation during the night prevents overcooling and saves you from catching a chill. Controller Buttons and Copy Function You can set up the Weekly Timer using the wireless remote controller. The copy function also enables a daily prograe to be repeated on other days as required. This makes it even easier to set the timer. Deactivates, reactivates or deletes. Moves back. Starts and completes settings. Copies settings. Prograe 3 On 21ºC 5:30 p.m. If you set the Weekly Timer an hour before you arrive home, you can enjoy a wave of cool air as soon as you step through the door. Prograe 3 On 23ºC 6:30 a.m. If you set the Weekly Timer 30 minutes before your wake-up time, you can avoid the hot and humid morning air and enjoy a pleasantly cool room as you get up. Moves forward. Selects timer, mode, setting significant number, day, time and temperature. Prograe 4 Off 0:00 a.m. Prograe 4 Off 8:00 a.m. The Weekly Timer will automatically stop operation when you go to bed. The Weekly Timer will automatically stop operation when you leave home. 27 28

Photocatalytic Air Purifying Titanium Apatite Photocatalytic Air-Purifying Filter Air filter catches dust Photocatalytic air purifying is a deodorising and antibacterial technology. Daikin was the first to apply this advance to the air-purifying filters used in air conditioners 1. Daikin s success has led manufacturers in various industries to adopt the technology for antibacterial products. Titanium apatite is an advanced photocatalytic material with great adsorption power. While a filter s micron-level fibres trap dust, titanium apatite effectively adsorbs and decomposes bacteria. The photocatalyst is activated simply by exposure to light. This filter delivers consistent performance for approximately three years if it is washed with water once every six months. Titanium Apatite Photocatalytic Air-Purifying Filter This filter is not a medical device. Benefits such as the adsorption and decomposition of bacteria are only effective for substances which are directly attached to the Titanium Apatite Photocatalytic Air-Purifying Filter. Anti-Corrosion Treatment of Outdoor Heat Exchanger Fins The outdoor unit s heat exchanger fins are processed using a special anti-corrosion treatment. The surface is covered with a thin acrylic resin layer to provide enhanced resistance to acid rain and salt corrosion. Effect of Titanium Apatite Photocatalyst Adsorbs Removes Light Cross section of anti-corrosion treated fin Hydrophilic film Aluminium Corrosion-resistant acrylic resin Odours Bacteria Decomposed Titanium Apatite Photocatalyst Heat exchanger fin Note: 1. This practical application of titanium apatite was a world first. Announced in September 2003 at the 3rd International Workshop on the Utilization and Coercialization of Photocatalytic Systems, Coatings for Clean Surfaces, Water and Air Purification. 29 30

Remote Control via Smartph one Smart Control by Smartphone The Daikin mobile controller application lets you manage Daikin inverter air conditioners from anywhere, helping to maintain a comfortable home environment while saving energy. This convenient app gives you full control of core functions such as start/stop, operation mode and set temperature as well as advanced features like weekly scheduling. The app also lets you monitor your system to ensure it is performing as desired. Setup is extremely easy. After downloading the software, you only need to connect to a private wireless network inside your home or mobile network outside. 1 Functions Start/stop operation Monitor current outdoor temperature 4 Set operation mode Set room temperature Set fan speed 3 Set airflow direction 3 Monitor current room temperature Set child-proof lock 3 Set weekly timer: actions per day, 28 actions in total) In Home Operation System Configuration Wireless Internet Environment at Home At home, the Daikin mobile controller application turns your smartphone into a centralised remote controller. 2 It only takes a few easy taps to check and adjust the temperature in a child s room on the second floor from the living room. You can also start and stop the air conditioner in the living room from your bedroom. New Page Daikin mobile controllerr (optional adaptor) BRP072A42 Remote control PC-board set 5 (optional adaptor) KRP067A41 or KRP980B2 Wireless router Smartphone Internet Daikin mobile controller application (free) Simply download the application and register your air conditioners. Out of Home Operation The Daikin mobile controller application takes care of those nagging worries about whether you turned off the air conditioner and ensures a comfortable air conditioned environment is waiting when you return home. Even outside your home, you can easily monitor and adjust points such as the operating status and room temperature or start and stop all units. This optional adaptor is not available for the FTKC15/20. For applicable models, go to http://www.daikinthai.com/dmobile/. A Daikin mobile controller (optional adaptor) is required for each indoor unit to enable control from smartphones. Required for Operation Daikin mobile controller (optional adaptor) (1) BRP072A42 Remote control PC-board set 5 (optional adaptor) KRP067A41 or KRP980B2 (2) + + + + Daikin mobile controller (3) Android TM * phone Wireless router or iphone** Users need to prepare items (1) to (3). A Daikin mobile controller (optional adaptor) is required for each indoor unit. application (free) Internet * Android is a trademark of Google Inc. ** iphone is a trademark of Apple Inc. 31 Notes: 1. For applicable OSs, go to http://www.daikinthai.com/dmobile/. An Internet connection is required to use this service. Standard smartphone charges also apply when using the Daikin mobile controller application to monitor or control air conditioners. 2. In-home control of air conditioners using the Daikin mobile controller application will depend on the effective coverage area of your LAN. 3. The controllable functions differ depending on the model. 4. Monitoring of the outdoor temperature is available for all models during operation. Some models can also perform monitoring while they are not operating. 5. An interface adaptor (KPR067A41 or KRP980B2) is also required for the FTKC25/35/50/60/71. 32

Function List of FTKV and FTKC Series Indoor Unit Models FTKV Series FTKC Series FTKV25/35 FTKV50/60 FTKV71 FTKC15/20 FTKC25/35 FTKC50/60/71 Functions DC Inverter Control Power-Airflow Dual Flaps Comfortable Airflow Power-Airflow Flap Wide-Angle Louvers Vertical Auto-Swing (up and down) Horizontal Auto-Swing (left and right) 3D Airflow Comfort Airflow Mode Comfort Control Indoor Unit Quiet Operation Auto Fan Speed Intelligent Eye Prograe Dry Function Standby Electricity Saving Lifestyle Convenience Cleanliness Econo Mode Inverter Powerful Operation Wireless Remote Controller with Backlight Daikin Mobile Controller (optional adaptor) Indoor Unit On/Off Switch Titanium Apatite Photocatalytic Air-Purifying Filter Wipe-Clean Flat Panel 24 Hour On/Off Timer Timers Count Up-Down On/Off Timer Weekly Timer Night Set Mode Worry Free Auto-Restart after Power Failure Self-Diagnosis with Digital Display Outdoor Unit FTKV Series FTKC Series Models RKV25/35 RKV50/60 RKV71 RKC15/20 RKC25/35 RKC50/60/71 Functions Comfort Control Worry Free Outdoor Unit Quiet Operation Anti-Corrosion Treatment of Outdoor Heat Exchanger Fins 33 34

Functions Comfortable Airflow Comfort Control Lifestyle Convenience Timers Power-Airflow Dual Flaps The Power-Airflow Dual Flaps can flatten out during cooling operation to deliver cool air to the corners of a room. See page 23 Power-Airflow Flap The Power-Airflow Flap flattens out during cooling operation to deliver cool air to the corners of a room. See page 23 Wide-Angle Louvers The Wide-Angle Louvers provide wide airflow coverage for effective operation no matter where the indoor unit is placed in a room. See page 24 Vertical Auto-Swing (up and down) This function automatically moves the flaps up and down to distribute air across a room. Horizontal Auto-Swing (left and right) Horizontal Auto-Swing automatically moves the louvers to the left and right to cover a room with cool air. 3D Airflow This function combines Vertical and Horizontal Auto-Swing to circulate a cloud of cool air right to the corners of even large spaces. The flaps and louvers swing in turn. See page 23 Comfort Airflow Mode This function prevents uncomfortable drafts from blowing directly on to the body. To prevent drafts, the flap moves upward during cooling operation. See page 24 Indoor unit operating sound pressure levels can be decreased from the Low setting fan speed using the wireless remote controller. See page 25 Outdoor unit operating sound pressure levels can be decreased from the rated operation sound using the wireless remote controller. See page 25 Auto Fan Speed The microprocessor automatically adjusts the fan speed to high to rapidly reach the set temperature. Once the temperature is achieved, this function reduces the fan speed to low. Intelligent Eye Intelligent Eye with its infrared sensor automatically controls air conditioner operation according to human movement in a room. When there is no movement for 20 minutes, it adjusts the temperature by approximately 2 C for energy savings. See page 21 Cleanliness Indoor Unit Quiet Operation Outdoor Unit Quiet Operation 7 m Top view 110 Side view Prograe Dry Function The microprocessor works to eliminate humidity while maintaining the most consistent temperature possible. It automatically controls the temperature and fan speed. Titanium Apatite Photocatalytic Air-Purifying Filter This filter contains the advanced photocatalytic material titanium apatite. While the filter s micron-level fibres trap dust, this photocatalyst adsorbs and decomposes bacteria. The filter can be used for up to three years with proper maintenance. See pages 29 and 30 Wipe-Clean Flat Panel The flat panel design can be cleaned with only the single pass of a cloth across its smooth surface. The flat panel can also be easily removed for more thorough cleaning. 90 7 m Standby Electricity Saving Even when an air conditioner is not operating, it requires standby power. However, thanks to this function, the required standby power can be reduced. See page 22 Econo Mode This mode limits maximum power consumption. It improves operating efficiency and also prevents circuit breakers from being overloaded. See page 22 Inverter Powerful Operation This function boosts cooling performance for 20 minute period. It is convenient when the air conditioner is first turned on or it is necessary to change the room temperature quickly. See page 24 Wireless Remote Controller with Backlight The backlit LCD allows easy operation in the dark. Frequently used functions are conveniently located on the front of the controller. Daikin Mobile Controller (optional adaptor) This optional adaptor and its application turn a smartphone into a remote controller that can be used inside or outside the home. Together they help to maintain comfort while saving energy and eliminate any worries about forgetting to turn off the air conditioner. See pages 31 and 32 Indoor Unit On/Off Switch The unit can be conveniently started by hand if the wireless remote controller is misplaced or its batteries are not charged. Bottom view Indoor Unit On/Off Switch This timer can start or stop the air conditioner within a 24 hour period. It can be preset in 10 minute steps by pressing the On/Off Timer button on the wireless remote controller. The On Timer and Off Timer can be used in combination. See page 26 Count Up-Down On/Off Timer The operation start and stop times can be set with the touch of a single button and preset for a period of one to 12 hours in one hour increments. When the Off Timer is set, Night Set Mode is activated automatically. See page 26 Weekly Timer The Weekly Timer allows up to four actions to be prograed for each day of the week. It is possible to schedule not only the on and off times, but also the desired temperatures during these periods. The copy function also makes the setting much easier and enables a daily prograe to be repeated on other days as required. See pages 27 and 28 Pressing the Off Timer button automatically selects Night Set Mode. This function prevents excessive cooling for a pleasant sleep. After 60 minutes, the room temperature is raised by 0.5 C for cooling operation. See page 26 +0.5 C Set temp. before Off timer begins to operate Worry Free 24 Hour On/Off Timer Night Set Mode Off timer turns on 60 min. Cooling Time Unit: minutes Off timer stops air conditioner Auto-Restart after Power Failure The air conditioner memorises the settings for operation mode (cooling, dry and fan only), airflow, temperature, etc., and automatically returns to them when power is restored after a power failure. Self-Diagnosis with Digital Display Malfunction codes are shown on the digital display panel of the wireless remote controller for fast and easy maintenance. Anti-Corrosion Treatment of Outdoor Heat Exchanger Fins The outdoor unit s heat exchanger fins are processed using a special anti-corrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins resistance to acid rain and salt corrosion. See page 30 Cross section of anti-corrosion treated fin Smile Curve The FTKC series features Daikin's new smile curve design for the front panel. The smile curve creates a stylish, modern appearance which blends easily with any interior decor. Hydrophilic film Aluminium Corrosion-resistant acrylic resin Heat exchanger fin 35 36

Wireless Remote Controller FTKV25/35 The backlit LCD allows easy operation in the dark. FTKC15/20 On and Off switch 1 Selects fan speed. Auto Fan Speed and Indoor Unit Quiet Operation Inverter Powerful Operation 3 Selects operation mode: Cooling, Dry and Fan Only. Outdoor Unit Quiet Operation 5 24 Hour Off Timer and Night Set Mode 2 4 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 8 9 10 11 12 13 14 Sets room temperature. Econo Mode Sets vertical airflow direction. Vertical Auto-Swing Intelligent Eye Selects time. 24 Hour On Timer Sets clock. Sets room temperature. 1 Econo Mode 2 Inverter Powerful Operation 3 Selects operation mode: Cooling, Dry and Fan Only. Comfort Airflow Mode 5 4 24 Hour On Timer 6 24 Hour Off Timer and Night Set Mode 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 8 9 10 11 12 13 14 On and Off switch Selects fan speed. Auto Fan Speed and Indoor Unit Quiet Operation Sets vertical airflow direction. Vertical Auto-Swing Cancels timer. Selects time. Resets settings. Sets clock. Cancels timers. 7 FTKV50/60/71 The backlit LCD allows easy operation in the dark. FTKC25/35/50/60/71 On and Off switch 1 9 Sets room temperature. Selects fan speed. Auto Fan Speed and Indoor Unit Quiet Operation Inverter Powerful Operation 3 Selects operation mode: Cooling, Dry and Fan Only. Comfort Airflow Mode and Intelligent Eye Selects timer, mode, setting significant number, day, time and temperature. 24 Hour Off Timer and Night Set Mode 2 4 5 6 7 Cancels timers. 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 10 11 12 13 Econo Mode and Outdoor Unit Quiet Operation Sets vertical airflow direction. Vertical Auto-Swing and 3D Airflow Sets horizontal airflow direction. Horizontal Auto-Swing and 3D Airflow Weekly Timer: Weekly Deactivates, reactivates or deletes Weekly Timer settings. Copy Back Next Starts and completes settings. Copies settings. Moves back. Moves forward. 24 Hour On Timer Starts cooling operation. 1 Starts dry operation. 2 Sets room temperature. 3 Inverter Powerful Operation 4 Intelligent Eye 5 Outdoor Unit Quiet Operation Night Set Mode and Count Up-Down Off Timer Count Up-Down On Timer 8 6 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 9 10 11 12 13 14 15 Off switch Starts fan only operation. Selects fan speed. Auto Fan Speed and Indoor Unit Quiet Operation Econo Mode Selects airflow angle. Vertical Auto-Swing Comfort Airflow Mode Cancels timers. 14 Sets clock. 37 38

Specifications for FTKV Series Options for FTKV Series Model name Capacity Power supply Running current (220-230-240 V, 50 Hz / 220-230 V, 60 Hz) Power consumption COP Indoor unit Front panel colour Airflow rate Fan speed Sound pressure levels Dimensions Machine weight Outdoor unit Casing colour Compressor Refrigerant Sound pressure levels Dimensions Machine weight Operation range Piping connection Max. piping length Max. level difference Indoor unit Outdoor unit H H/L/SL H x W x D Type Motor output Charge H/SL H x W x D Liquid Gas Drain Type A W W/W m 3 /min (cfm) db (A) kg W kg db (A) kg CDB m FTKV25NVM RKV25NVM 2.5 (1.2-3.4) 8,500 (4,100-11,600) 2.7-2.9-2.8 / 2.7-2.9 540 4.63 FTKV25NVM 7.8 (275) 37/25/22 38/26/23 283 x 800 x 195 RKV25NVM 46/43 9 800 0.9 550 x 765 x 285 34 ø9.5 20 15 FTKV35NVM RKV35NVM 3.5 (1.3-4.1) 11,900 (4,400-14,000) 4.4-4.2-4.0 / 4.4-4.2 910 3.85 FTKV35NVM 8.0 (282) RKV35NVM 47/44 FTKV50NVM RKV50NVM 5.2 (1.7-6.0) 17,700 (5,800-20,500) 6.0-5.7-5.5 / 6.0-5.7 1,300 4.00 FTKV50NVM 14.3 (504) 43/34/31 RKV50NVM FTKV60NVM RKV60NVM 6.0 (1.9-7.0) 20,500 (6,500-23,900) 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz Pure white 5 steps, quiet and automatic Ivory white 290 x 1,050 x 250 12 Hermetically sealed swing type R-32 7.4-7.1-6.8 / 7.4-7.1 1,580 3.80 FTKV60NVM 15.4 (544) 45/35/32 RKV60NVM 48/44 52/46 735 x 825 x 300 19.4 to 46 FTKV71NVM RKV71NVM 7.1 (2.3-8.9) 24,200 (7,800-30,400) 9.3-8.9-8.5 / 9.3-8.9 2,000 3.55 FTKV71NVM 18.2 (643) 46/37/33 340 x 1,050 x 248 14 RKV71NVM 2,400 1.5 52/49 770 x 900 x 320 Measurement conditions 1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m. 2. Sound pressure levels are based on the temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions. ø6.4 ø18.0 1,300 1.2 43 ø12.7 30 20 60 ø15.9 Indoor Unit No. Item 1 2 3 4 5 Notes: *1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit. *2. The time clock and other devices should be obtained locally. *3. The filter is a standard accessory. 5-room centralised controller KRC72A Outdoor Unit No. Item 1 2 Air direction adjustment grille Drain plug Note: *1. One set includes five pieces for five units. Control System No. Item 1 2 3 4 5-room centralised controller Wiring adaptor for time clock/remote controller (Normal open pulse contact/normal open contact) Titanium apatite photocatalytic air-purifying filter Remote controller loss prevention with chain Daikin mobile controller Central remote controller Unified On/Off controller Schedule timer Air direction adjustment grille KPW945A4 Interface adaptor for DIII-NET use Titanium apatite photocatalytic air-purifying filter KAF970A46 * 1 * 1 * 2 * 3 Drain plug KKP937A4 * 1 * 1 * 1 RKV25/35 KPW937A4 KKP937A4 FTKV25/35/50/60/71 KRC72A KRP413AB1S KAF970A46 KKF910A4 BRP072A42 RKV50/60 KPW945A4 FTKV25/35/50/60/71 DCS302CA61 DCS301BA61 DST301BA61 KRP928BB2S RKV71 KKP945A4 Note: *1. Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit. Central remote controller DCS302CA61 Unified On/Off controller DCS301BA61 Schedule timer DST301BA61 39 40

Specifications for FTKC Series Model name Capacity Power supply Running current Power consumption COP Indoor unit Front panel colour Airflow rate Fan speed Sound pressure levels Dimensions Machine weight Outdoor unit Casing colour Compressor Refrigerant Sound pressure levels (220-230-240 V, 50 HZ / 220-230 V, 60 HZ) Dimensions Machine weight Operation range Piping connection Max. piping length Max. level difference Indoor unit Outdoor unit H H/L/SL H x W x D Type Motor output Type Charge H SL H x W x D Liquid Gas Drain A W W/W m 3 /min (cfm) db (A) kg W kg db (A) kg CDB m FTKC15PVM RKC15PVM 1.5 (0.75-1.9) 5,100 (2,500-6,500) 2.2 337 4.45 FTKC15PVM RKC15PVM 278 FTKC20PVM RKC20PVM 2.0 (1.0-2.4) 6,800 (3,400-8,200) FTKC25QVM RKC25QVM 2.5 (1.0-3.4) 8,500 (3,400-11,600) 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz 2.6 3.2 500 4.00 FTKC20PVM Shiny pure white 9.0 (318) 38/25/22 283 x 770 x 203 46-47-47/48-49 680 (210-1,100) 3.67 5 steps, quiet and automatic 38/25/19 RKC20PVM FTKC25QVM FTKC35QVM Shiny white RKC25QVM Hermetically sealed swing type 441 641 0.50 23 8 Ivory white R-32 47 283 x 770 x 223 44 550 x 658 x 275 19.4 to 46 FTKC35QVM RKC35QVM 3.5 (1.3-4.1) 11,900 (4,400-14,000) 4.5 960 (250-1,455) 3.65 10.8 (381) 39/26/22 RKC35QVM Measurement conditions 1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m. 2. Sound pressure levels are based on the temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions. ø6.4 ø9.5 ø16.0 15 12 913 0.70 49 26 Model name Capacity Power supply Running current Power consumption COP Indoor unit Front panel colour Airflow rate Fan speed Sound pressure levels Dimensions Machine weight Outdoor unit Casing colour Compressor Refrigerant Sound pressure levels Dimensions Machine weight Operation range Piping connection Max. piping length Max. level difference Indoor unit Outdoor unit H H/L/SL H x W x D Type Motor output Type Charge H/SL H x W x D Liquid Gas Drain A W W/W m 3 /min (cfm) db (A) kg W kg db (A) kg CDB m FTKC50QVM RKC50QVM 5.2 (1.4-6.0) 17,700 (4,800-20,500)) 6.3 1,365 (260-1,730) 3.80 FTKC50QVM 44/35/29 RKC50QVM 49/43 FTKC60QVM RKC60QVM 6.0 (1.4-6.7) 20,500 (4,800-22,900) 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz 8.0 16.7 (590) 1,200 1.00 36 ø12.7 1,740 (300-2,060) 3.45 FTKC60QVM Shiny white 5 steps, quiet and automatic 45/36/30 295 x 990 x 263 13 RKC60QVM Ivory white Hermetically sealed swing type R-32 50/43 595 x 845 x 300 19.4 to 46 FTKC71QVM RKC71QVM 7.1 (2.1-7.5) 24,200 (7,200-25,600) 10.9 2,365 (400-2,550) 3.00 FTKC71QVM 17.3 (611) 46/37/31 RKC71QVM Measurement conditions 1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m. 2. Sound pressure levels are based on the temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions. ø6.4 ø16.0 30 20 1,300 1.05 51/46 40 ø15.9 Options for FTKC Series Indoor Unit No. Item 1 2 3 4 Titanium apatite photocatalytic air-purifying filter Remote controller loss prevention with chain Daikin mobile controller Remote control PC-board set Notes: *1. The filter is a standard accessory. *2. Remote control PC-board set (KRP067A41 or B2KRP980B2) is also required for each indoor unit. * 1 * 2 FTKC15/20 KKF917A4 FTKC25/35 FTKC50/60/71 KAF970A46 KKF910A4 BRP072A42 KRP067A41 or KRP980B2 Daikin mobile controller Dimensions (H x W x D) Gross weight Standby electricity Wireless LAN standard Accessories BRP072A42 79 x 52 x 17.5 Note: 40 g 1.2 W or less (adaptor only) * 1 IEEE802.11 b/g/n (2.4 GHz) Wire harness (1,600 ), screws (two pieces), double-faced tape, installation manual *1. When using a wireless LAN adaptor, there is continuous transmission between the air conditioner and the adaptor, so the air conditioner will not enter standby electricity saving mode. When the adaptor is connected, the standby electricity consumption of the product is about one Watt. Outdoor Unit No. Item 1 Air direction adjustment grille 2 Drain plug Note: *1. One set includes five pieces for five units. RKC15/20 KPW937B4 KKP937A4 RKC25/35 RKC50/60/71 KPW937D4 KPW5E112 * 1 Titanium apatite photocatalytic air-purifying filter KAF970A46 Remote controller loss prevention with chain KKF917A4 41 42