Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Bosch BVA Series Air Handler

HIGH EFFICIENCY AIR HANDLER

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Ruud Standard Efficiency Air Handler

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Rheem Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

Rheem High Efficiency Air Handler

Modular Multi-position Air Handler

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

TECHNICAL SPECIFICATIONS

AIR HANDLERS AIR HANDLERS

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

TECHNICAL SPECIFICATIONS

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

HIGH EFFICIENCY AIR HANDLER

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER

Commercial High-Efficiency Condensing Units

TECHNICAL SPECIFICATIONS

Rheem High Efficiency Air Handler

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

13 GEP A L P - 1 A

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

Variable Speed Convertible Air Handler 5 Ton

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

36,000-62,000 BTUH Nominal Capacity

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

PAJ3. Product Specifications

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

13 SEER CONDENSING UNITS & AIR HANDLERS

Commercial High-Efficiency Condensing Units

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

PAR5. Product Specifications

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Bosch BVA Series Air Handler

Advance Release September 2009

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

RGE 13 A T - 1 A

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Variable Speed Convertible Air Handler 2 1/2 Ton

50TM COMBINATION HEATING/COOLING UNITS

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Product Data. Convertible Air Handlers 1 1/2 5Ton

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

WJH4 Product Specifications

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

16 SEER TWO-STAGE AIR CONDITIONERS

Product Data. Fig. 1 - Unit 50VR -A

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Variable Speed Convertible Air Handler 4 Ton

SUBMITTAL DATA. Medbrooke ADD. Stuart Mc Munn Company 137 North Sixth Street Clarksburg, WV for. Prepared for

TECHNICAL SPECIFICATIONS

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant

TECHNICAL SPECIFICATIONS

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

Unit Features & Benefits RQPM/RQRM Series

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

COMMERCIAL AIR HANDLER

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

Modular Multi-position Air Handlers

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

13 SEER HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Product Data. Convertible Air Handlers 1 1/2 5Ton

ELECTRICAL QUANTITY WEIGHT (LB)

50TM TFF COMBINATION HEATING/COOLING UNITS

General Description. Operation

Transcription:

RHEEM Split Systems Condensers All submitted condensers meet the 15 SEER minimum All submitted condensers meet the 208/230V specification All submitted condensers contain enhanced mufflers to help dissipate vibration energy for quieter unit operation All submitted condensers are powder coated for a long lasting professional finish AHU s 1.5 ton AHU has a volumetric flow rate of 600 CFM, 2-ton AHU has a volumetric flow rate of 800 CFM, and 2.5-ton AHU has a volumetric flow rate of 1000 CFM, which meet and exceed the design specifications All submitted AHU s have factory installed 5KW electric heating kits with pullouts All submitted AHU s contain molded polymer corrosion resistant condensate drain pans All submitted AHU s DO NOT exceed the maximum dimensions: 18 in W, 50 in H, and 23 in D All submitted AHU s are Upflow, and have high efficient fan motors and drain connections All submitted AHU s meet the 208/230V specification Warranty All submitted Split Systems have registered a 10 years parts warranty

Date: Mar 11 2015 Job: U.C.F Customer: ADVANCE MECHANICAL Address: ORLANDO, FL Submitted By: SHINE LOVE

Equipment List for Project: U.C.F - Dated: Mar 11 2015 Units Tag No Model No Description HP - 1 AH - 1 HP - 2 AH - 2 HP - 3 AH - 3 RP1518AJ1 RH1T2417STANJC RP1524AJ1 RH1T2417STANJC RP1530AJ1 RH1T3617STANJC RP15: Classic 1 1/2 ton 15 SEER Single Stage Heat Pump RH1T: Constant Torque Motor Single Stage Airflow with Aluminum Evaporator Coil Voltage: 208-230/60/1 Factory Options: None RP15: Classic 2 ton 15 SEER Single Stage Heat Pump RH1T: Constant Torque Motor Single Stage Airflow with Aluminum Evaporator Coil Voltage: 208-230/60/1 Factory Options: None RP15: Classic 2 1/2 ton 15 SEER Single Stage Heat Pump RH1T: Constant Torque Motor Single Stage Airflow with Aluminum Evaporator Coil Voltage: 208-230/60/1 Factory Options: None Accessories For Tag No Field Model Description Notes For Tag No Heat Input(kW) Heater Field Model HP - 1 4.8 RXBH-1724?05J HP - 2 4.8 RXBH-1724?05J HP - 3 4.8 RXBH-1724?05J

Product Submittal Mar 11 2015 Project - U.C.F ORLANDO, FL Date: Mar 11 2015 Performance Summary Tag: HP - 1 Model No: RP1518AJ1 / RH1T2417STANJC Project: U.C.F City: ORLANDO State: FL Altitude: 95 Cooling Performance Air Discharge: Upflow/Downflow/Horizontal AHRI Ref: 7508987 AHRI Rating - Capacity: 18,800 EER: 12.5 SEER: 15 Ambient Air (F) - Dry Bulb: 92.5 Wet Bulb: 76.3 Airflow (CFM) - CFM: 600 SCFM: 600 System Entering Air (F) - Dry Bulb: 80 Wet Bulb: 67 % RH: 51.1 System Leaving Air (F) - Dry Bulb: 57.8 Wet Bulb: 56.9 Air Enthalpy (btu/lb) - Entering: 31.4 Leaving: 24.3 Design Net Cooling Capacity (btuh) - Total: 19,200 Sensible: 14,400 Latent: 4800 Total Power - Watts: 1336.8 KW: 1.3 Heating Performance AHRI Rating @ High Heating - Capacity: 17000 COP: 3.6 HSPF: 8.5 Electric Heat Input - KW: 4.8 @ 230 Volts Heating Airflow (CFM) - CFM: 600 Air Dry Bulb (F) - Outdoor: 41.7 Entering Air: 70 Leaving Air: 118.2 Air Temperature Rise (F) - Rise: 48.2 Capacity (btuh) - Total: 16,378 Total Heating Power - Watts: 5407.4 KW: 5.4 Air Moving System Characteristics External Static Pressure (inches WG) ESP: 0.1 - Blower Speed or Speed Tap - Tap: Low Motor Characteristic (watts & BHP) - Power: 0 Drive: Direct Electrical Supply Outdoor Unit Power Supply Volt/Hz/Ph: 208-230/60/1 (Volt/Hz/Ph) - Outdoor Unit Min Ampacity (amps) - Ampacity: 12 Max Overcurrent Protection (amps) - Fuse: 20 HACR Breaker: 20 Field Installed Electric Heater Kit - RXBH-1724?05J Power Supply (Voltage/Hz/Ph) - 230/60/1 Minimum Ampacity (amps) - 32 Max Overcurrent Protection (amps) - Fuse: 35 (Single circuit power supply for air handlers & heaters)

Dimensions, Weight & Clearances Dimensions - Length: 29-3/4 Width: 29-3/4 Height: 25 Outdoor Unit Weight (lb) (lb) - Weight: 133 Air Handler Dimensions (inches) - Length: 21 11/16 Width: 17 1/2 Height: 42 1/2 Air Handler Weight (lb) - Weight: 92 Outdoor Unit Clearances (inches) - Sides: 24 Top: 36 Product Submittal #: 76611873-0328-486f-9112-668553d88689 Submittal Printed on: 3/11/2015 1:04:44 PM For Model: RP1518AJ1 In keeping with its policy of continous progress and product improvement, reserves the right to make changes without notice. Gross capacity does not include the effect of motor heat. AHRI rating is net capacity and includes the effect of fan motor heat. All net capacities also accounts for the effect of motor heat. ASHRAE Weather Data 2009 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA, USA. www.ashrae.org All rights reserved. Used by permission in this program.

Unit Drawings for HP - 1 - RP1518AJ1

Air Handler Unit Drawings for AH - 1 - RH1T2417STANJC

Feature List for HP - 1 - RP1518AJ1

Air Handler Feature List for AH - 1 - RH1T2417STANJC

Product Submittal Mar 11 2015 Project - U.C.F ORLANDO, FL Date: Mar 11 2015 Performance Summary Tag: HP - 2 Model No: RP1524AJ1 / RH1T2417STANJC Project: U.C.F City: ORLANDO State: FL Altitude: 95 Cooling Performance Air Discharge: Upflow/Downflow/Horizontal AHRI Ref: 7509020 AHRI Rating - Capacity: 24,000 EER: 12.5 SEER: 15 Ambient Air (F) - Dry Bulb: 92.5 Wet Bulb: 76.3 Airflow (CFM) - CFM: 800 SCFM: 800 System Entering Air (F) - Dry Bulb: 80 Wet Bulb: 67 % RH: 51.1 System Leaving Air (F) - Dry Bulb: 57.8 Wet Bulb: 56.6 Air Enthalpy (btu/lb) - Entering: 31.4 Leaving: 24.2 Design Net Cooling Capacity (btuh) - Total: 26,100 Sensible: 19,100 Latent: 7000 Total Power - Watts: 1838 KW: 1.8 Heating Performance AHRI Rating @ High Heating - Capacity: 22200 COP: 3.6 HSPF: 9 Electric Heat Input - KW: 4.8 @ 230 Volts Heating Airflow (CFM) - CFM: 800 Air Dry Bulb (F) - Outdoor: 41.7 Entering Air: 70 Leaving Air: 112.6 Air Temperature Rise (F) - Rise: 42.6 Capacity (btuh) - Total: 16,378 Total Heating Power - Watts: 5696.7 KW: 5.7 Air Moving System Characteristics External Static Pressure (inches WG) ESP: 0.1 - Blower Speed or Speed Tap - Tap: High Motor Characteristic (watts & BHP) - Power: 0 Drive: Direct Electrical Supply Outdoor Unit Power Supply Volt/Hz/Ph: 208-230/60/1 (Volt/Hz/Ph) - Outdoor Unit Min Ampacity (amps) - Ampacity: 14 Max Overcurrent Protection (amps) - Fuse: 20 HACR Breaker: 20 Field Installed Electric Heater Kit - RXBH-1724?05J Power Supply (Voltage/Hz/Ph) - 230/60/1 Minimum Ampacity (amps) - 32 Max Overcurrent Protection (amps) - Fuse: 35 (Single circuit power supply for air handlers & heaters)

Dimensions, Weight & Clearances Dimensions - Length: 29-3/4 Width: 29-3/4 Height: 25 Outdoor Unit Weight (lb) (lb) - Weight: 131 Air Handler Dimensions (inches) - Length: 21 11/16 Width: 17 1/2 Height: 42 1/2 Air Handler Weight (lb) - Weight: 92 Outdoor Unit Clearances (inches) - Sides: 24 Top: 36 Product Submittal #: 76611873-0328-486f-9112-668553d88689 Submittal Printed on: 3/11/2015 1:04:48 PM For Model: RP1524AJ1 In keeping with its policy of continous progress and product improvement, reserves the right to make changes without notice. Gross capacity does not include the effect of motor heat. AHRI rating is net capacity and includes the effect of fan motor heat. All net capacities also accounts for the effect of motor heat. ASHRAE Weather Data 2009 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA, USA. www.ashrae.org All rights reserved. Used by permission in this program.

Unit Drawings for HP - 2 - RP1524AJ1

Air Handler Unit Drawings for AH - 2 - RH1T2417STANJC

Feature List for HP - 2 - RP1524AJ1

Air Handler Feature List for AH - 2 - RH1T2417STANJC

Product Submittal Mar 11 2015 Project - U.C.F ORLANDO, FL Date: Mar 11 2015 Performance Summary Tag: HP - 3 Model No: RP1530AJ1 / RH1T3617STANJC Project: U.C.F City: ORLANDO State: FL Altitude: 95 Cooling Performance Air Discharge: Upflow/Downflow/Horizontal AHRI Ref: 7509100 AHRI Rating - Capacity: 30,200 EER: 13 SEER: 15.5 Ambient Air (F) - Dry Bulb: 92.5 Wet Bulb: 76.3 Airflow (CFM) - CFM: 1000 SCFM: 1000 System Entering Air (F) - Dry Bulb: 80 Wet Bulb: 67 % RH: 51.1 System Leaving Air (F) - Dry Bulb: 58.6 Wet Bulb: 57.3 Air Enthalpy (btu/lb) - Entering: 31.4 Leaving: 24.6 Design Net Cooling Capacity (btuh) - Total: 30,700 Sensible: 23,100 Latent: 7600 Total Power - Watts: 2034.1 KW: 2.0 Heating Performance AHRI Rating @ High Heating - Capacity: 28200 COP: 3.54 HSPF: 8.2 Electric Heat Input - KW: 4.8 @ 230 Volts Heating Airflow (CFM) - CFM: 1000 Air Dry Bulb (F) - Outdoor: 41.7 Entering Air: 70 Leaving Air: 108.9 Air Temperature Rise (F) - Rise: 38.9 Capacity (btuh) - Total: 16,378 Total Heating Power - Watts: 6352.8 KW: 6.4 Air Moving System Characteristics External Static Pressure (inches WG) ESP: 0.1 - Blower Speed or Speed Tap - Tap: Low Motor Characteristic (watts & BHP) - Power: 0 Drive: Direct Electrical Supply Outdoor Unit Power Supply Volt/Hz/Ph: 208-230/60/1 (Volt/Hz/Ph) - Outdoor Unit Min Ampacity (amps) - Ampacity: 19 Max Overcurrent Protection (amps) - Fuse: 30 HACR Breaker: 30 Field Installed Electric Heater Kit - RXBH-1724?05J Power Supply (Voltage/Hz/Ph) - 230/60/1 Minimum Ampacity (amps) - 32 Max Overcurrent Protection (amps) - Fuse: 35 (Single circuit power supply for air handlers & heaters)

Dimensions, Weight & Clearances Dimensions - Length: 33-3/4 Width: 33-3/4 Height: 31 Outdoor Unit Weight (lb) (lb) - Weight: 160 Air Handler Dimensions (inches) - Length: 21 11/16 Width: 17 1/2 Height: 42 1/2 Air Handler Weight (lb) - Weight: 99 Outdoor Unit Clearances (inches) - Sides: 24 Top: 36 Product Submittal #: 76611873-0328-486f-9112-668553d88689 Submittal Printed on: 3/11/2015 1:04:51 PM For Model: RP1530AJ1 In keeping with its policy of continous progress and product improvement, reserves the right to make changes without notice. Gross capacity does not include the effect of motor heat. AHRI rating is net capacity and includes the effect of fan motor heat. All net capacities also accounts for the effect of motor heat. ASHRAE Weather Data 2009 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA, USA. www.ashrae.org All rights reserved. Used by permission in this program.

Unit Drawings for HP - 3 - RP1530AJ1

Air Handler Unit Drawings for AH - 3 - RH1T3617STANJC

Feature List for HP - 3 - RP1530AJ1