PCRAU0726F. Multi-Split Type Air Conditioners L Series with DC Inverter Power Control Cooling Only & Heat Pump [50 Hz]

Similar documents
The Comfort and Luxury You Deserve

The Comfort and Luxury You Deserve

A wider lineup of DC Inverter and Non-Inverter air conditioners with 19 models is currently available. You can choose whichever that fits your

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

The Comfort and Luxury You Deserve

PCR0709A. Options. Indoor unit

Inverter Wall Mounted

Inverter Wall Mounted

Inverter Wall Mounted

CHI NHAÙNH HAØ NOÄI Taàng 12, toøa nhaø Ocean Park Tower, 1 Ñaøo Duy Anh, Quaän Ñoáng Ña, Haø Noäi

The Comfort and Luxury You D eserve

The World s No.1 Heat Pump Company HEATING AND COOLING SOLUTIONS SUPER MULTI NX MULTI-SPLIT AIR CONDITIONERS DC INVERTER CONTROL

PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V

LV Series. SEER 20+ Wall Mount Heat Pump

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home

Split Type Air Conditioners

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only

Up to SEER 26.1 Wall Mount Heat Pump

LV Series. SEER 15+ Concealed Built in Heat Pump

PVVVN1325aprv. PCVAU1327 Preview. Cooling Only / Heat Pump 50 Hz

VRV IV S-series heat pump

DAIKIN Modular Inverter Air Cooled Chiller

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home

Split Type Air Conditioners

FBQ. DC Duct Heat Pump or Cooling Only

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home

w w w. d a i k i n. e u ATXS-E

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C

FAQ. Wall Mount Heat Pump or Cooling Only

HEAT PUMPS BY DAIKIN. Energy efficient heating and cooling solutions for your home

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

PLXSID1605. Warning HEAD OFFICE :

Daikin air conditioners for your home

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home

Si REMOVAL PROCEDURE. 2.5/3.2/3.5 kw Class. Outdoor Unit Inverter Pair Type

Air Conditioners. Technical Data FTXS-G

Daikin air conditioners for your home

PCRAU0306K. Happiness starts at home.

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

HEATING AND COOLING SOLUTIONS DUCTED SYSTEMS PCDUAU1117

Si REMOVAL PROCEDURE. 4.0/5.0/5.2/5.8/6.8/7.5 kw Class. Outdoor Unit Inverter Multi Type

SiUS181631EA. Service Manual. Multi-Split Type Air Conditioners RMXS-L Series. [Applied Models] Inverter Multi : Heat Pump

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

FOR REPLACEMENT USE PCV1213. Cooling Only 50 Hz

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

Single outdoor unit series suitable for homes, offices, shops, and middle-sized buildings

Service Manual. Inverter Pair Floor Standing Type K-Series. Draft. SiBE [Applied Models] Inverter Pair : Heat Pump

air conditioners for your home, apartments, shops, restaurants, offices, hotels, w w w. d a i k i n. e u S U P E R M U L T I P L U S

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

Energy-saving operation

COOLING ONLY HEAT PUMP PCV0612F. Cooling Only 50 Hz/60 Hz. Heat Pump 50 Hz/60 Hz

HEATING AND COOLING SOLUTIONS DUCTED SYSTEMS PCDUAU0517

HEAT PUMPS BY DAIKIN. Energy efficient heating and cooling solutions for your home

SHOPS, RESTA URA NTS, OFFICES, HOTELS,

HEATING AND COOLING SOLUTIONS DUCTED SYSTEMS PCDUAU0517

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

MULTI SYSTEM SHOPS RESTAURANTS SMALL OFFICES COMMERCIAL MULTI SYSTEM.

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

S p l i t S y S t e m S heating & cooling SolutionS

DAIKIN FCQ SERIES HEATING & COOLING SYSTEMS. ROUNDFLOW CEILING-MOUNTED CASSETTE Up to 18.6 SEER / Up to 10.2 HSPF Up to 13.0 EER

HEATING AND COOLING SOLUTIONS DUCTED HEAT PUMPS PCDUNZ0717

E 1E. small offices and shops. The ideal air conditioning system for. 5S+1E concepts of

DUCTED HEATING AND COOLING SOLUTIONS From daikin. Whole house comfort for your home

Inverter Wall Mounted Series

Daikin air conditioners for your home

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Daikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS

BENEFIT FROM LOWER FUEL COSTS.

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

Product Brochure 2017

DUCTED SYSTEMS PCDUAU0216 HEATING & COOLING SOLUTIONS

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

About Daikin: WARNINGS:

COOLING ONLY HEAT PUMP

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps. FTXS-G

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

MULTI SYSTEM TECHNOLOGY. 1. Ururu Humidification PART 2 - URURU MULTI

for your home FTYN-GX FT(Y)N-F

AIR PURIFICATION SOLUTIONS PCAPNZ1017 AIR PURIFIER

Heat Pump Air Conditioning Systems

for Light Commercial Use

HEATING AND COOLING SOLUTIONS SPLIT SYSTEMS PCSPAU1117

Product Brochure Smart Power. Low Profile Ducted

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

Air conditioners, heating & cooling for shops,restaurants and offices

SPLIT SYSTEMS PCSPAU1015 HEATING & COOLING SOLUTIONS

DAIKIN FAQ SERIES HEATING & COOLING SYSTEMS. INDOOR WALL-MOUNTED UNITS Up to 18.6 SEER / Up to 9.4 HSPF Up to 12.7 EER

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

RC-0219-A. Single-Split Non Inverter Series

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

. Creating Maximum Comfort

HEATING AND COOLING SOLUTIONS SPLIT SYSTEMS PCSPAU1018

Transcription:

Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion and may have resultant impacts on warranty. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. PCRAU07F Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Multi-Split Type Air Conditioners L Series with DC Inverter Control Only & Heat Pump [0 Hz] Cautions on product corrosion. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.. If the outdoor unit is to be installed close to the sea, direct exposure to sea breeze should be avoided. If you need to install the outdoor unit close to the sea, contact your local distributor. JMI-007 Organization: DAIKIN INDUSTRIES, LTD. AIR CONDITIONING MANUFACTURING DIVISION Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, COMPRESSORS AND VALVES. JQA- Organization: DAIKIN INDUSTRIES (THAILAND) LTD. Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM Daikin Australia Pty Limited (ISO900) QEC May, 00 Sydney, Brisbane, Adelaide, Melbourne, Newcastle, Townsville, Perth, Auckland All of the Daikin Group s business facilities and subsidiaries in Japan are certified under the ISO 00 international standard for environment management. Daikin Australia Pty Limited (ISO00) CEM07 October 7, 00 Sydney, Brisbane, Melbourne, Adelaide Dealer Specifications, designs and other content appearing in this brochure are current as of August 0 but subject to change without notice. Head Office: Umeda Center Bldg., --, Nakazaki-Nishi, Kita-ku, Osaka, 0-8 Japan Tokyo Office: JR Shinagawa East Bldg., -8-, Konan, Minato-ku, Tokyo, 08-007 Japan http://www.daikin.com/global_ac/ c All rights reserved 09/ DN Connectable to max. 9 indoor units

An. to. kw Multi-Split system that suits large and luxurious houses Daikin s Super Multi PLUS L series is connectable to up to 9 indoor units and offers you a richer choice of indoor units to coordinate with each room décor. Advanced technology from Daikin has achieved a high COP and low sound level to suit today s modern living environment. Main features of Daikin s SUPER MULTI PLUS Wide range of outdoor units models of outdoor units are available in the wide range of., and. kw classes. A maximum of 9* indoor units can be connected. * Combination is possible with. kw class outdoor unit and.0 kw class indoor units. Connectable to max. 9* indoor units New Wide variety of indoor units models of indoor units grouped into 7 types (heat pump)ceiling-mounted cassette, ceiling-mounted built-in, ceiling-suspended, duct-connected, wall-mounted, floor-standing, and floor/ceiling-suspended dual typesprovide a wide range of options for interior coordination. Energy efficient The scroll compressor, DC inverter and DC fan motor technologies are energy efficient, achieving high COP values. * Combination is possible with. kw class outdoor unit and.0 kw class indoor units. Quiet operation Latest technologies and features achieve the quiet sound level of during night quiet mode operation for outdoor units, realising comfortable operation. Great flexibility in installation Long piping lengths of m for the. kw class outdoor unit and simplified wiring reduce restrictions on the installation position.

Wide range of choices To suit every room in large houses, small shops and small offices, the Super Multi PLUS L series offers a wide range of indoor and outdoor units. A wide range of indoor and outdoor units New A wide variety of stylish indoor units Ceiling-mounted cassette type Ceiling-mounted built-in type Outdoor unit models. kw, kw,. kw The outdoor unit can be selected from three models for the precise power to suit the size of house, shop or office. Indoor unit models 7 types (heat pump) RMK(X)SLVA (. kw) RMK(X)S0LVA ( kw) RMK(X)S0LVA (. kw) A wide range of indoor units includes heat pump models in 7 types and cooling only models in types. Indoor units can be selected to match each room and preference. Type 0 Rated.0. only. 0.0 0.0 7 7. Rated 0.0.. 0.0 0.0 7 7. Ceiling-suspended type Duct-connected type Ceiling-mounted cassette type FCQ-B FCQ-B 00 x 00 FFQ-B FFQ-B Ceiling-mounted built-in type FBQ-B FBQ-B Wall-mounted type Floor-standing type Ceiling-suspended type FHQ-B FHQ-B Duct-connected type CDKS-EA (700 width type) CDXS-EA (700 width type) CDKS-C (900/,00 width type) FDXS-C (900/,00 width type) Wall-mounted type FTKS-K FTXS-K Floor/ceiling-suspended dual type FTKS-KA FTXS-KA Floor-standing type FVXS-K Floor/ceiling-suspended dual type FLXS-B FLXS-G

Energy efficiency and quiet operation Efficient and quiet operation The Super Multi PLUS L series outdoor units use the latest technologies for energy efficient performance and quiet operation. Energy Efficient With DC inverter power control the air conditioner can operate at low most of the time. DC inverter power control is able to achieve a high COP even when multiple indoor units operate simultaneously for long periods of time. During night time RMXS0L Master bedroom. kw class Bedroom ().0 kw class Bedroom (). kw class operation operation,990 W,0 W COP.9 COP. Bedroom () Master bedroom Bedroom () The high efficiency compressor to achieve a higher COP Compressor equipped with Reluctance DC motor Daikin DC Inverter models are equipped with the Reluctance DC motor for compressor. The Reluctance DC motor uses different types of torque, neodymium magnet* and reluctance torque*. This motor can save energy because it generates more power with a smaller electric power than an AC or conventional DC motor. Motor efficiency (%) 90 80 70 0 Reluctance DC motor Conventional DC motor More than 0% AC motor 0 0 0 0 90 0 Reluctance DC motor RMK(X)SL RMK(X)S0L RMK(X)S0L Small load Low Rotational speed (rps) Large load High Quiet operation What is COP? An air conditioner's COP (coefficient of performance) indicates how efficiently it uses energy. A high COP means high energy efficiency. COP = Quietness is yet another important feature of Daikin s Super Multi PLUS L series. To reduce sound, latest technologies and features are applied to the outdoor units, achieving quiet operating sound level of in night quiet mode. Capacity (W) (W) Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory using Daikin products. *. A neodymium magnet is approximately 0 times stronger than a standard ferrite magnet. *. The torque created by the change in power between the iron and magnet parts. >> Smooth sine wave DC inverter Use of an optimised sine wave smoothes motor rotation, further improving operating efficiency. Sine wave DC inverter Night quiet mode Mode. Automatic mode Operation sound level selectable from steps for the night mode Set on the outdoor PCB. Time of maximum temperature is memorised. The low operating mode will become active 8 hours* after the peak temperature in the daytime, and operation will return to normal 0 hours* after that. The operation sound level for the night mode can be selected from 9 db (A) (Step ), (Step ) and (Step ). Mode. Manual mode Starting time and ending time can be input. (External control adaptor for outdoor unit, DTA0A or DTA0A, and a subsequently obtained timer are necessary.) Mode. Combined mode Combination of mode and can be used depending on your needs. *. Initial setting. Can be selected from, 8 and 0 hours. *. Initial setting. Can be selected from 8, 9 and 0 hours. Capacity % Load % Operation sound Mode. 00 0 0 9 Automatic mode (For RMKSL) Peak in the outdoor temperature 8 hrs 0 hrs (Initial setting) Step max. - (. kw) Step max. - (. kw) Step max. - 9 (. kw) Night mode starts (Initial setting) Night Mode Step : 9 Step : Step : Night mode ends 8:00 :00 :00 0:00 0:00 :00 8:00 Notes: This function is available in setting at site. The relationship of outdoor temperature (load) and time shown in the graph is just an example. The reduction rate differs depending on the operation sound level step selected. Smooth Air Inlet Bell Mouth and Aero Spiral Fan These two features work to reduce sound. Guides are added to the bell mouth intake to reduce turbulence in the airflow generated by fan suction. The Aero Spiral Fan features fan blades with the bent blade edges, further reducing turbulence. DC fan motor Efficiency improved in all areas compared to conventional AC motors, especially at low speeds. DC fan motor structure Efficiency (%) 00 80 0 0 0 DC motor efficiency (Comparison with a conventional AC motor) Approx. 0% increase DC motor Approx. 0% increase AC motor With the bent blade edge 0 00 00 00 00 00 700 800 900 000 Motor speed (rpm) Without the bent blade edge Escaping eddies are sucked in by the bent blade edges, reducing overall turbulence. Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory.

Design flexibility and easy installation The Super Multi PLUS L Series is connectable to up to 9 indoor units. While the BP unit and the REFNET joint make installation simple, long piping length and simplified wiring broaden design flexibility. As many as 9 indoor units can be connected to a single outdoor unit Thin refrigerant piping makes handling and connecting easier, resulting in significantly reduced installation time. For outdoor unit. kw installation Simplified electrical wiring connection The outdoor unit and the BP units operate from separate single-phase power supplies, so no power supply wiring is needed between them. The size of the wiring pipe from the outdoor unit to the BP units can be reduced, making installation easier. Earth leakage circuit breaker Safety breaker supply 0 A Outdoor unit D transmission line ( lines) (Outdoor unit--bp, BP--BP) Transmission line ( lines) (Indoor unit--bp / including earth wire) Earth wire 7 8 9 units supply A BP unit ( ports) BP unit ( ports) BP unit ( ports) BP unit >> 8 indoor units for a kw installation >> indoor units for a. kw installation REFNET joint Safety breaker Earth leakage circuit breaker Earth wire The BP unit is an innovative development which allows Super Multi PLUS outdoor units to be connected to a wide range of different indoor unit types. The BP unit has the ability to precisely vary refrigerant volume to meet the cooling requirements of individual room spaces. ports BPMKS97A ports BPMKS97A The REFNET joint reduces the amount of work involved in installation and increases the reliability of the system. Optional REFNET joint: KHRPAT Durable outdoor unit The outdoor unit s heat exchanger fins are processed using a special anticorrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins resistance to acid rain and salt corrosion. A hydrophilic film layer also prevents rust caused by the run off of water droplets. Heat exchanger fin Space saving A single high- outdoor unit can drive up to 9 indoor units, making it powerful enough to aircondition a whole residence. This powerful unit can be easily installed on a balcony with its slimline design, which measures (H), x (W) 900 x (D) 0. 900 0, Long refrigerant piping Wide Operation Range A maximum total piping length of m offers flexibility in the choice of installation positions for the indoor units, and simplifies system planning. Hydrophilic film Aluminium Corrosion-resistant acrylic resin The Super Multi PLUS has the wide operation range required for coercial-use air-conditioning systems. Piping length for RMK(X)S0L Total main piping length Total branch piping length m 90 m Total main and branch piping length m ( + 90) Note: Refrigerant charge is required. (Chargeless piping length 0 m) Max. height difference 0 m Main piping Branch piping BP unit Branch piping BP unit Cross section of anticorrosion-treated fin Outdoor temperature ( C DB) 0 0 0 0 0 0-0 C DB - C DB Outdoor temperature ( C WB) 0 0 0-0 -0. C WB C WB 7 8

Centralised Control system Indoor unit lineup Both Super Multi PLUS and VRV systems are compatible with the Building Air-Conditioning Control System. This allows Super Multi PLUS and VRV units to be conveniently operated from the same coon controller when the two systems are installed together in a building. Type Ceiling-mounted cassette type 0 Rated.0 only.. 0.0 0.0 7 7. Rated 0.0.. 0.0 0.0 7 7. Central remote controller DCS0CA Central remote controller (option) groups (zones) of indoor units can be controlled individually same as LCD remote controller. Max. groups controllable Zone control Malfunction code display 00 x 00 FCQ-B FFQ-B FCQ-B FFQ-B Unified on/off controller (option) Ceiling-mounted built-in type groups of indoor units can be operated simultaneously/individually. FBQ-B FBQ-B Unified on/off controller DCS0BA Max. groups controllable Operating status indication Centralised control indication Ceiling-suspended type FHQ-B FHQ-B Schedule timer (option) 8 indoor units can be operated on a 7-day prograed schedule. Max. 8 indoor units controllable The start and stop time for twice a day can be set for the week in a unit of one minute. Duct-connected type CDKS-EA (700 width type) CDXS-EA (700 width type) Schedule timer DST0BA CDKS-C (900/,00 width type) FDXS-C (900/,00 width type) -room centralised controller KRC7 -room centralised controller (option) indoor units can be controlled. This is a low cost system which can only control about on/off. Max. indoor units controllable Contribute to save energy by eliminating turn-off of lamps. Wall-mounted type FTKS-K FTKS-KA FTXS-K FTXS-KA Compatible indoor units FCQ, FFQ FBQ FHQ C(F)DK(X)S FTK(X)S FVXS FLXS Floor-standing type Central remote controller* FVXS-K Unified on/off controller* Schedule timer* Floor/ceiling-suspended dual type -room centralised controller* Notes: *. An interface adaptor (KRP98BBS or DTABA) is also required for each indoor unit. *. A wiring adaptor (KRPABS) is also required for each indoor unit. FLXS-B FLXS-G 9 0

Ceiling-mounted cassette (multi flow) type Specially designed for false ceilingsfor a smooth, modern interior finish The ideal air conditioner for installation inside narrow false ceilingswith only the decoration panel visible after installation. A simple design makes it comfortable to the public eye in shops and small offices in tenant buildings, as well as right at home in the living rooms with false ceilings found in multi-storey apartment blocks. Comfort and quietness Three convenient patterns for auto-swing operation Standard: a swing range of 0 to Draft prevention: a limited swing range of 0 to 0 prevents airflow from blowing directly onto people. Soiling prevention: a limited swing range of 0 to prevents ceilings from becoming dirty due to direct airflow. Standard Design flexibility Compact decoration panel All models feature a decoration panel with the same compact size and simple design for easier planning of lighting systems and harmonising of interior décor. 90 Same for all models Draft prevention 90 Decoration panel is optional only Heat pump. kw class FCQBVE FCQBVE.0 kw class FCQ0BVE FCQ0BVE.0 kw class FCQ0BVE FCQ0BVE 7. kw class FCQ7BVE FCQ7BVE Option Note: Remote controller cables not included. Cables should be obtained locally. Option Signal receiver unit Note: Wireless remote controllers and signal receiver units are sold as a set. Soiling prevention Light and compact main units The indoor units weigh only and require an installation space with a height of just. Min. High-lift drain pump Quiet operation The turbofan was designed using aviation technology to reduce draft resistance inside the unit, achieving quiet sound level of /9 to /0. A system provides lift for the drain pump of up to 70 from the ceiling. This is convenient for multi-storied buildings, which have a large amount of other 70 piping and wiring inside the ceiling. Diffuser -dimensional blade Installation flexibility High-ceiling applications FCQ /9 db(a) FCQ0 /9 db(a) FCQ0 /0 db(a) FCQ7 /0 db(a) (H/L) These models have the power to provide a comfortable airflow even with a ceiling height of up to.8 m. Max..8 m Optional fresh air intake kit Allows fresh air to be circulated using only the fan for improved room ventilation. This is useful in buildings where ventilation fans cannot be installed. Optional branch duct chamber A chamber can be connected to the air conditioner to provide additional airflow for crowded spaces or areas sensitive to outside temperatures. Fresh air intake kit Intake duct Air filter (Outdoor) Hood Branch duct chamber Discharge duct Discharge panel Note: The intake duct, hood, air filter, insect screen, fireproof damper, etc. should be obtained locally if required. Note: The discharge duct, discharge panel, etc. should be obtained locally if required.

Ceiling-mounted cassette (compact multi flow) type Compact dimensions suitable for the light coercial market Design flexibility Comfort and quietness The ideal air conditioner for installation inside narrow false ceilingswith only the smooth and simply finished decoration panel visible after installation. The compact dimensions are suitable even for the light coercial market as well as for the living rooms with false ceilings found in multistorey apartment blocks. 00 x 00 Designed to fit 00 wide ceiling grids 8 700 7 7 Compact decoration panel Quiet sound level of only. At low fan speeds, the. kw model produces sound of only., and even the.0 kw model as low as. This is due to a spiral hub cover that reduces internal airflow resistance. Spiral hub cover only Heat pump. kw class FFQBVB FFQBVB. kw class FFQBVB FFQBVB.0 kw class FFQ0BVB FFQ0BVB.0 kw class FFQ0BVB FFQ0BVB Option Note: Remote controller cables not included. Cables should be obtained locally. Option Signal receiver unit Note: Wireless remote controllers and signal receiver units are sold as a set. 700 T-bar grid does not need to be cut. Ceiling panel T-bar (H/L) FFQ FFQ FFQ0 FFQ0 /. db(a) / db(a) /7 db(a) / db(a) Low draft performance is designed for your comfort. 00 00 0 Horizontal Flow 0 Even for modules other than 00 x 00, no inspection opening is required. Maintenance can be performed after simply removing the grille, because the switchbox is built into the unit. Less draught Multi-flow system offers a selection of air discharge patterns that suit all areas. -way flow -way flow -way flow Comfortable across all areas Conditioned air is distributed evenly by Auto-swing operation. AUTO-SWING Adjustable airflow angle to suit all room conditions. direction Standard setting 0 0 Auto-swing between 0 and 0 0 0 Settable to different levels between 0 and 0 Draft prevention setting (Set on site) 0 Auto-swing between 0 and 0 Settable to different levels between 0 and pattern patterns pattern " " denotes piping direction. " " denotes sealing member for air discharge outlet (option). Note: For -way or -way flow installation, the sealing member for air discharge outlet (option) must be used to close off the unused outlet(s). Setting to prevent soiling of ceiling (Set on site) Auto-swing between and 0 0 0 Settable to different levels between and 0 Note: Angles shown above are provided as a guide. They may differ depending on the installation site.

Ceiling-mounted built-in type Flexible air discharge unit to fit various forms of space This ceiling-mounted built-in air conditioner is highly flexible in installation. The visible part is small, with a simple finish that blends in with any type of room. Installation flexibility Meets diverse installation needs The indoor unit can be installed in rooms with as little as 0 between the drop ceiling and ceiling slab. It also works with both flexible and ordinary ducts. Standard installation examples In crawl space With canvas bellows and air intake panel (sold separately) only Heat pump.0 kw class FBQ0BV FBQ0BV 7. kw class FBQ7BV FBQ7BV Option Note: Remote controller cables not included. Cables should be obtained locally. Air blow Air conditioner Air conditioner 0 or more Long-life filter 9 Air intake With high-efficiency filter Air blow 7 7 Long-life filter Ceiling return with high-efficiency filter Air blow Air conditioner Air intake Air conditioner 0 or more 8 0 or more Air intake Air blow Ceiling return Air blow Air blow Ordinary duct (procured locally) Long-life filter Air conditioner Air intake Air conditioner With ordinary ducts 0 9 8 Air intake or more 8 Ordinary duct (procured locally) 0 or more 0 or more Air intake Options Decoration panel Air discharge opening adaptor Canvas bellows and air intake panel Flexible duct Air discharge grille Air discharge chamber 7 High-performance filter 8 Inspection panel 9 Rear intake blocking pad 0 Air discharge opening flange Rear intake filter chamber Branch duct Low-draft filter chamber Flexibly adapts to room interiors To cope with the challenges of L-shaped or U-shaped spaces, it is possible to install the air discharge unit away from the main unit. This extends the possibilities for coping with human gathering patterns or sun lighting. At the same time, different types of architectural space can be kept comfortable. Provided with drain water lift-up High-efficiency filter (option) mechanism as standard equipment Available in two types: % and 90% colourimetry. Drainage pipes can be run as high as 0 above the drain outlet. 0 Air discharge opening adaptor Flexible duct (dia. 00 ) Canvas bellows Decoration panel and air intake panel Flexible duct (dia. 0 ) Branch duct Air discharge chamber Air discharge grille L-shaped room U-shaped room Long room Comfort and quietness Quiet operation Comfort and quietness FBQ0 / db(a) FBQ7 / db(a) (H/L)

Ceiling-suspended type Slim body with quiet and wide airflow This ceiling-suspended type air conditioner features a slim body with a quiet and wide airflow. Comfort and quietness Spreads comfortable air throughout the room Auto-swing for comfort in all directions. Wide air discharge openings produce a spreading 00 airflow Design and installation flexibility Easier installation for greater freedom of design Uniform height and depth. Narrower design for small- models to meet tighter dimensional constraints. Indoor unit () FHQ FHQ0 FHQ0 00 Height Width 9 90,0 Installable on ceilings. m high Depth 80 only Heat pump. kw class FHQBVVB FHQBVVB.0 kw class FHQ0BVVB FHQ0BVVB.0 kw class FHQ0BVVB FHQ0BVVB Option Note: Remote controller cables not included. Cables should be obtained locally. Option Signal receiver unit Note: Wireless remote controllers and signal receiver units are sold as a set. Drain pump kit (option) can be easily incorporated Drain pipe connection can be done inside the unit. Refrigerant and drain pipe outlets are at the same opening. Quiet operation Quiet operation has been emphasised even more on the exposed ceiling suspended type unit. FHQ 7/ db(a) * Capacity may be affected. FHQ0 8/ db(a) FHQ0 9/ db(a) (H/L) 00 Drain pump kit (built inside main unit) Uses quiet stream fan and other quiet technologies. Sound damper Turbulent flow is produced Straightening vane Quiet stream fan Easier to maintain Long-life filter lasts approximately year* Non-dew flap without bristles * For dust concentration of 0. mg/m Absence of bristles minimises clinging dirt and simplifies Two time settings (00 hrs and 0 hrs) are available to cleaning. match the installation environment. Maintenance time warning is displayed on the remote controller (filter sign). Easy-clean, flat surfaces It is easy to wipe dirt off the flat side and lower surfaces of the unit. Non-dew flap 7 8

Duct-connected type Slim and smooth design suits your shallow ceiling The visible parts have a smooth and sophisticated finish that blends with any type of interior décor. A wireless remote controller is a standard feature with prewired receiver, offering you great convenience. 700 width type 900/,00 width type Option Installation flexibility Slim and compact design Models in the CDKS-EA and CDXS-EA series are only 700 in width and in weight, so are easily installed in limited spaces. Just 00 in height, all models can be installed in rooms with as little as 0 depth between the drop ceiling and ceiling slab, making them ideal for even shallow ceilings. CDKS-EA CDXS-EA 0. kw class. kw class. kw class. kw class.0 kw class.0 kw class only CDKSEAVMA CDKSEAVMA only CDKSCVMA CDKSCVMA CDKS0CVMA CDKS0CVMA Heat pump CDXSEAVMA CDXSEAVMA Heat pump FDXSCVMA FDXSCVMA FDXS0CVMA FDXS0CVMA Only 700 00 Signals from the wireless remote controller are transmitted to the signal receiver. Comfort and quietness Dimensions (H x W x D) Weight External static pressure 900 CDKS-C FDXS-C CDKSEA CDXSEA CDKSEA CDXSEA 00 x 700 x 0 /s 0 Pa 00 * Width for the CDKS0C and FDXS0C models is,00. CDKSC CDKSC FDXSC FDXSC 00 x 900 x 0 8 /s 7 /s 0 Pa Quiet operation Quiet operation sound level of only 9 is achieved. (H/L/SL) CDKS C(F)DXS //9 db(a) * Capacity may be affected. CDKS C(F)DXS //9 db(a) Home Leave Operation CDKS0 FDXS0 7// db(a) CDKS0 FDXS0 8// db(a) Home Leave Operation prevents large rises or falls in the indoor temperature by continuing operation* while you are sleeping or out of your home. This means that an airconditioned welcome awaits when you wake or return. It also means that the indoor temperature can quickly return to your favourite comfort setting. * Home Leave Operation can be selected for any temperature from 8 to C for cooling operation and 0 to 0 C for heating operation. * Home Leave Operation function must be set using the remote controller when going to sleep or leaving the house, and after waking up or returning home. Air discharge duct* Air discharge grille* AIR Suspension bolt* Suction duct* * Locally obtained parts Air filter Option Suction grille (KDGF9A) Signal receiver wire Length =,900 Chamber Signal receiver AIR Air suction grille* Notes:. To prevent an increase in operation noise, avoid installing the air suction grille directly below the suction chamber.. Grilles, piping connections, ducts, and installation parts should be obtained locally. Duct-connected types do not have drain-up pumps.. The signal receiver unit must be located near the air suction inlet, because the unit includes a sensor that detects room temperature. 9 0

Wall-mounted type Stylish flat panel harmonises with your interior décor The simple and sophisticated flat panel design coordinates smoothly with any type of interior décor. Its refined design and functions provide you with a comfortable living environment, all year round. only Heat pump only Heat pump.0 kw class FTKS0KVMA FTXS0KVMA.0 kw class FTKS0KAVMA FTXS0KAVMA. kw class FTKSKVMA FTXSKVMA.0 kw class FTKS0KAVMA FTXS0KAVMA. kw class FTKSKVMA FTXSKVMA 7. kw class FTKS7KAVMA FTXS7KAVMA Option Option Comfort and quietness Quiet operation Wall-mounted type indoor units achieve quiet sound level of. (H/L/SL) FTKS0/ 8// db(a) FTKS // db(a) * Capacity may be affected. FTKS0 // db(a) FTKS0 // db(a) FTKS7 /7/ db(a) Intelligent Eye Intelligent Eye with its infrared sensor automatically controls air conditioner operation according to human movement in a room. When there is no movement, it adjusts the temperature by C for energy savings. Versatile remote control The remote controller with a backlit liquid crystal display and luminescent control buttons also features a built-in Weekly Timer that can be prograed to suit your lifestyle, with up to four actions per day for each day of the week. This controller not only allows you to prograe on and off times, but also the desired temperature during those times. Furthermore, the copy function enables any daily prograe to be replicated on any other day or days as required. The LCD panel with backlight A luminescent material is used for the buttons on the surface. Weekly Timer operation button When you are in the room Comfort Airflow Mode When you go out Comfort Airflow Mode prevents uncomfortable drafts from blowing directly on to your body. With this function, when you press the COMFORT button during cooling operation, the flap moves upward to prevent direct cold drafts. During heating operation, it also moves downward to prevent direct drafts and deliver warm air to the floor. Clean air Titanium Apatite Photocatalytic Air-Purifying Filter Air filter Catches dust Econo Mode operation Econo Mode reduces the maximum running current and the maximum power of the outdoor unit to the rated values. This is useful when using multiple air conditioners and other electrical devices at the same time. Running current and power Maximum Normal operation Maximum during normal operation operation Titanium Apatite Photocatalytic Air-purifying Filter Titanium apatite is a photocatalytic material with high adsorption power. Titanium apatite also effectively adsorbs and decomposes bacteria across its entire surface. The photocatalyst is activated simply by exposure to light. These filters are not medical devices. Benefits such as the adsorption and decomposition of bacteria are only effective for substances that are collected on and in direct contact with the Titanium Apatite Photocatalytic Air-Purifying Filter. Rated Econo Mode Maximum during Econo Mode Bacteria Removal Test Testing method: dropping method Result certificate: No. 0- and 0- Testing organisation: Japan Spinners Inspecting Foundation Time From start-up until set temperature is reached This diagram is a representation for illustrative purposes only. Maximum decreases during Econo Mode, requiring more time to reach the set temperature.

Floor-standing type Dual discharges to evenly distribute air across the whole room A space-saving air-conditioner of simple and neat appearance. It distributes airflow to the furthest corners with efficient Vertical Auto-Swing and Wide-Angle Louvres. Dual air discharge for enhanced comfort Daikin s inverter floor standing units are especially effective in heating. The unit features dual air outlets that diffuse warm air at floor level, and vertical auto swing louvers on the top air outlet, providing uniform distribution of heated air in the room. In warmer months, the lower air outlet can be shut off, leaving the top air diffuser to stream cool refreshing air upwards. Stylish and compact flat panel The clever construction of the elegant flat panel unit allows the flexibility of fully exposed installation against a wall or semi-recessed installation in spaces such as in a mantelpiece.. kw class. kw class.0 kw class Heat pump FVXSKVA FVXSKVA FVXS0KVA Double airflow keeps feet warm during heating operation. Easy to clean The flat panel design makes cleaning the front face of the unit a breeze. Surface dust can be simply wiped away with a soft cloth. Furthermore, the unit can be installed off the floor to allow for cleaning of the floor space under the unit. Wiping clean the flat panel is a breeze. Clean air Easily clean beneath the unit. Versatile remote control The remote controller with a backlit liquid crystal display and luminescent control buttons also features a built-in Weekly Timer that can be prograed to suit your personal lifestyle, with up to four actions per day for each day of the week. This controller not only allows you to prograe on and off times, but also the desired temperature during those times. Furthermore, the copy function enables any daily prograe to be replicated on any other day or days as required. Correct prograing of the unit may also result in considerable energy savings. Weekly Timer operation button D air filter catches dust. Titanium apatite photocatalytic air-purifying filter Internal structure Uses a Titanium Apatite Photocatalytic Air-Purifying Filter. Titanium apatite is a photocatalytic material with high adsorption power. It effectively adsorbs and removes bacteria. These filters are not medical devices. Benefits such as the adsorption and decomposition of bacteria are only effective for substances that are collected on and in direct contact with the Titanium Apatite Photocatalytic Air-Purifying Filter. Bacteria Removal Test Testing method: dropping method Result certificate: No. 0- and 0- Testing organisation: Japan Spinners Inspecting Foundation

Floor/ceiling-suspended dual type Floor/ceiling dual use maximises free space Two-way installation The floor/ceiling-suspended dual type s slim, rounded design allows both ceiling-suspended and floor-level installation. Ceiling-suspended installation frees up wall and floor space, while floor-level installation is possible. Comfort and quietness Comfortable airflow Vertical Auto-Swing and Wide-Angle Louvres realise that comfortable airflow spreads throughout a large room. With these functions, the whole room can be evenly air-conditioned from either a floor-level or ceiling-suspended installation. The louvres can be adjusted by hand. Design and installation flexibility Slim and attractive indoor unit The curved design of the indoor unit merges smoothly with the wall or floor to enhance the décor of any room. Compact and lightweight indoor unit The indoor unit is only 90 in height and weighs a featherlight, which means it can be quickly and efficiently installed by one person. Heat pump. kw class FLXSBVMA. kw class FLXSGVMA.0 kw class FLXS0GVMA.0 kw class FLXS0GVMA 90,00 00 Clean air The Vertical Auto-Swing and Wide-Angle Louvres direct warm/cool air to every corner of your room. Quiet operation The floor/ceiling-suspended dual type indoor units achieve quiet sound level of 8. Photocatalytic Deodorising Filter The Photocatalytic Deodorising Filter is able to decompose odours and even removes bacteria and viruses. This filter can be used indefinitely if regular maintenance is carried out. Bacteria Removal Test Testing method: dropping method Result certificate: No. 980897-00 Virus Removal Test Testing method: washout method Result certificate: No. 980897-00 Testing organisation: Japan Food Research Laboratories (H/L/SL) FLXS FLXS FLXS0 FLXS0 7//8 db(a) 8//9 db(a) 7/9/ db(a) 8//9 db(a) During cooling operation * Capacity may be affected. Ceiling-suspended installation Floor-level installation

Function list Models Indoor unit Ceiling-mounted cassette type Ceiling-mounted built-in type Ceiling-suspended type Duct-connected type Wall-mounted type Floor-standing type Floor/ceiling-suspended dual type Outdoor unit Functions Comfortable airflow Comfort control Lifestyle convenience Cleanliness Timers Worry free Flexibility -airflow dual flaps Wide-angle louvres Vertical auto-swing (up and down) Horizontal auto-swing (left and right) -D airflow Comfort airflow mode Indoor unit quiet operation Night quiet mode Intelligent eye Automatic operation ( only) Prograe dry function Auto fan speed Hot-start function ( only) Quick warming function ( only) Automatic defrosting ( only) Inverter powerful operation Econo mode Home leave operation Indoor unit on/off switch Titanium apatite photocatalytic air-purifying filter Photocatalytic deodorising filter Long-life air filter High-efficiency filter kit (option) Fresh air intake kit (option) Wipe-clean flat panel Filter cleaning indicator -hour on/off timer 7-hour on/off timer Weekly timer Night set mode Auto-restart after power failure Self-diagnosis with digital display Anticorrosion treatment of outdoor heat exchanger fins Drain pump mechanism Ceiling soiling prevention FCQ FFQ FBQ FHQ CDK(X)S/FDXS FTK(X)S0// FTK(X)S0/0/7 FVXS FLXS 7 8

Function dictionary 9 Comfortable Airflow -Airflow Dual Flaps -Airflow Dual Flaps can flatten out during cooling operation to deliver cool air to the corners of a room. The flaps can direct warm air straight down to the floor during heating operation. Wide-Angle Louvres Smoothly curved Wide-Angle Louvres provide wide airflow coverage for effective cooling/heating operation. Vertical Auto-Swing (up and down) Vertical Auto-Swing automatically moves the flaps up and down to distribute air across a room. Horizontal Auto-Swing (left and right) Horizontal Auto-Swing automatically moves the louvres to the left and right to cover a room with cool/warm air. -D Airflow This function combines Vertical and Horizontal Auto-Swing to circulate a cloud of cool/warm air right to the corners of even large spaces. Comfort Airflow Mode This function prevents uncomfortable drafts from blowing directly on to the body. The flap changes the airflow direction. To prevent drafts, the flap moves upward during cooling operation and downward during heating operation. Comfort Control Indoor Unit Quiet Operation Indoor unit operating sound level is decreased by or db (A) from the low setting fan speed using the wireless remote controller. Night Quiet Mode Operation sound level is selectable from steps for the night mode. This function is available in setting at site. Intelligent Eye Intelligent Eye with its infrared sensor automatically controls air conditioner operation according to human movement in a room. When there is no movement, it adjusts the temperature by ± C for energy savings. Automatic Operation ( only) This function automatically selects cooling or heating operation mode based on the room temperature at start-up. Prograe Dry Function This function automatically reduces the level of humidity. Auto Fan Speed The microprocessor automatically controls fan speed to adjust the room temperature to the set temperature. Hot-Start Function ( only) After defrosting or when starting heating operation, air is preheated before discharge to prevent uncomfortable cold drafts. Quick Warming Function ( only) During low outdoor temperatures, this function preheats the compressor to shorten the time required to discharge warm air. Automatic Defrosting ( only) Before starting heating operation, a sensor checks for frost in the outdoor unit and performs automatic defrosting if necessary so that only warm air is discharged. Lifestyle Convenience Inverter ful Operation This function is convenient for boosting cooling/heating performance for a 0-minute period both when you first turn on your air conditioner and want to quickly change the room temperature. Econo Mode Econo Mode reduces the maximum running current and maximum power of the outdoor unit to the rated values. This is useful when using multiple air conditioners and other electrical devices at the same time. Home Leave Operation Home Leave Operation continues operation to prevent a room from becoming too hot or cold while you are sleeping or out of your home. Select any temperature from 8 to C for cooling operation and 0 to 0 C for heating operation. Indoor Unit On/Off Switch The unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged. Cleanliness Titanium Apatite Photocatalytic Air-Purifying Filter Uses a Titanium Apatite Photocatalytic Air-Purifying Filter. Titanium apatite is a photocatalytic material with high adsorption power. It effectively adsorbs and removes bacteria. It lasts for years without replacement if washed about once every months. Photocatalytic Deodorising Filter This filter decomposes odours and even removes bacteria and viruses. This power is maintained simply by exposing the filter to sunlight once every months. Long-Life Air Filter Maintenance is not required for one year. High-Efficiency Filter Kit (option) Two types are available: % and 90% colorimetry. Fresh Air Intake Kit (option) You can provide air-conditioning with fresh air from outside. Convenient for places where a ventilation fan cannot be installed. Note:. Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally.. Outside air fan interlocked with air conditioning unit is necessary. Optional PCB (KRPC) is required for interlocking.. It is recoended that the volume of outdoor air introduced through the kit is limited to 0% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating sound and may also influence temperature sending. Wipe-Clean Flat Panel The flat panel models can be cleaned with only the single pass of a cloth across their smooth surface. The flat panel can also be easily removed for more thorough cleaning. Filter Cleaning Indicator Dust deposited on the air filters is not only unhygienic, it also reduces the operating efficiency of the air conditioner. A message indicates when the air filters need cleaning. Timers -Hour On/Off Timer This timer can be preset to start and stop at any time within a -hour period. The air conditioner is started/stopped simply by pressing the On/Off timer button on the wireless remote controller. 7-Hour On/Off Timer This timer can be set to start and stop at any time within a 7-hour period. Simply press the On timer button, and the air conditioner will automatically start to operate at the preset time. Weekly Timer This timer can be preprograed with settings for day of the week, time of day, temperature, and operation on/off. A maximum of four air conditioner start or stop points can be entered per day for each of seven days in a one-week period simply by pressing the WEEKLY button. Night Set Mode Pressing the Off timer button automatically selects the Night Set Mode. This function prevents excessive cooling or heating for pleasant sleep conditions. Worry Free Auto-Restart After Failure The air conditioner memorises the settings for mode, airflow, temperature, etc., and automatically returns to them when power is restored after a power failure. Self-Diagnosis with Digital Display Malfunction codes for each indoor unit are shown on the digital display panel of the wireless remote controller for fast and easy maintenance. Anticorrosion Treatment of Outdoor Heat Exchanger Fins The outdoor unit s heat exchanger fins are processed using a special anticorrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins resistance to acid rain and salt corrosion. Flexibility Drain Pump Mechanism Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping. Ceiling Soiling Prevention Air discharge mechanism keeps airflow away from the ceiling. Ceiling cleaning is less frequently required. 0

Specifications Outdoor unit Indoor unit Outdoor unit Ceiling-mounted cassette (multi flow) type only FCQBVE FCQ0BVE FCQ0BVE FCQ7BVE FCQBVE FCQ0BVE FCQ0BVE FCQ7BVE supply phase, 0-0 V/0 V, 0/0 Hz /s (cfm) (9) 0 (0) 7 (7) (9) (9) 0 (0) 0 (0) 7 (7) 7 (7) supply Capacity (rated) Number of indoor units to be connected Number of BP to be connected Casing colour Compressor Refrigerant Refrigerant oil Sound level Sound power level Type Motor output Type Charge Model Charge kw kw kw /s (cfm) RMKSLVA.. to.. only RMKS0LVA.0 7.0 to 8. 8.0 RMKS0LVA RMXSLVA phase, 0-0 V, 0 Hz... 8.0 to 0.8. to. 9 Ivory white Hermetically sealed scroll type..,77 (,7) R-0A.0 DAPHNE FVC8D.7 7 7 RMXS0LVA.0.0 7.0 to 8. 8.0,77 (,7) 8 RMXS0LVA. 8.0 to 0.8 9. 7 9 Sound level* Sound power (H/L) level (H) Fan speed Temperature control Unit dimensions (H x W x D) Liquid (flare) Piping connections Gas (flare) Drain Heat insulation Model Panel Colour (option) Dimensions (H x W x D) Weight Note: * For 0 V operation. ø /9 8 Ceiling-mounted cassette (compact multi flow) type /0 /9 /0 /9 /0 0 8 0 8 0 steps Microcomputer control 0 x 80 x 80 ø. ø ø. ø.7 ø.9 ø ø.7 I.D ø x O.D ø Both liquid and gas pipes BYCK-W White 0 x 90 x 90 00 x 00 ø ø.9 Dimensions (H x W x D), x 900 x 0 CDB - to Operating range CWB - to. Number of wiring connections for power supply (including earth wiring), for interunit wiring (outdoor unit-bp) Piping connections Liquid (flare) ø Gas (brazing) ø9. Total main piping and branch piping m Max. interunit Total main piping m piping length Total branch piping m 0 80 90 0 80 Max. length for each room m Necessity of additional charge /m m Necessary* Between indoor or BP unit and outdoor unit: 0 Max. height difference m Between indoor and BP unit: Note: * Refrigerant charge is required. (Chargeless piping length 0 m) Formula for calculation charge: R () R = Total length (m) of liquid pipe size at ø x 0.0 + Total length (m) of liquid piping size at ø. x 0.0 Measurement conditions. operation data is based on the following conditions: indoor temp. 7 CDB, 9 CWB; outdoor temp. CDB; Equivalent piping length from outdoor unit to BP unit m; from BP unit to each indoor unit m; level difference 0m.. operation data is based on the following conditions: indoor temp. 0 CDB; outdoor temp. 7 CDB, CWB; Equivalent piping length from outdoor unit to BP unit m; from BP unit to each indoor unit m; level difference 0m.. Sound levels are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions. 90 supply /s (cfm) Sound level* Sound power (H/L) level (H) Fan speed Temperature control Unit dimensions (H x W x D) Liquid (flare) Piping connections Gas (flare) Drain Heat insulation Panel Model Colour (option) Dimensions (H x W x D) Weight only FFQBVB 0 (8) /.. FFQBVB 7 () / 9 FFQ0BVB 00 () /7 FFQ0BVB FFQBVB FFQBVB FFQ0BVB FFQ0BVB phase, 0-0 V, 0 Hz 0 (0) / 8 0 (8) 0 (8) /. /... 7 () 7 () / / 9 9 00 () 00 () /7 /7 0 (0) 0 (0) / / 8 8 steps Microcomputer control 8 x 7 x 7 ø. ø ø.7 ø ø.7 VP0 (External Dia. /Internal Dia. 0) Both liquid and gas pipes BYFQ0B8W White x 700 x 700.7 Note: * Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.

Ceiling-mounted built-in type Duct-connected type <700 width> supply /s (cfm) Sound level* Sound power (H/L) level (H) Fan speed Temperature control Dimensions (H x W x D) Liquid (flare) Piping connections Gas (flare) Drain Heat insulation Model Panel Colour (option) Dimensions (H x W x D) FBQ0BV 8 (00) ø. ø.7 only FBQ7BV FBQ0BV phase, 0-0 V, 0 Hz 7 (70) 8 (00) 8 (00) / 0 steps Microcomputer control 00 x,000 x 800 ø ø. ø.9 ø.7 I.D ø x O.D ø Both liquid and gas pipes BYBS7DJW White x,00 x 00 / 0 FBQ7BV 7 (70) 7 (70) ø ø.9 supply /s (cfm) Sound level* Sound power (H/L/SL) level (H) Fan speed Temperature control Dimensions (H x W x D) Liquid (flare) Piping connections Gas (flare) Drain Heat insulation External static pressure Pa CDKSEAVMA only CDKSEAVMA phase, 0-0 V/0-0 V, 0/0 Hz (07) //9 CDXSEAVMA steps, quiet and automatic Microcomputer control 00 x 700 x 0 ø. ø VP 0 (External Dia. /Internal Dia. 0) Both liquid and gas pipes 0 (07) //9 CDXSEAVMA Note: * The operation sound level values represent those for rear-suction operation and an external static pressure of 0 Pa. Sound level values for bottom-suction operation can be obtained by adding. Weight Note: * For 0 V operation.. Duct-connected type <900/,00 width> Ceiling-suspended type only CDKSCVMA CDKSCVMA CDKS0CVMA CDKS0CVMA FDXSCVMA FDXSCVMA FDXS0CVMA FDXS0CVMA supply Front panel colour Sound level (H/L) Sound power level (H/L) Fan speed Temperature control Dimensions (H x W x D) Piping connections Heat insulation Liquid (flare) Gas (flare) Drain /s (cfm) FHQBVVB 7/ /8 ø FHQ0BVVB FHQ0BVVB FHQBVVB phase, 0-0 V, 0 Hz White 7 (8) 8 (00) 7 (8) 7 (8) 8/ /9 9/ /9 7/ 7/ /8 /8 9 x 90 x 80 only steps Microcomputer control 9 x,0 x 80 7 ø. 9 x 90 x 80 VP 0 (External Dia. /Internal Dia. 0) Both liquid and gas pipes FHQ0BVVB 8/ 8/ /9 /9 ø.7 ø ø.7 FHQ0BVVB 8 (00) 7 () 9/ 9/ /9 /9 9 x,0 x 80 7 supply /s (cfm) Sound level* Sound power (H/L/SL) level (H) Fan speed Temperature control Dimensions (H x W x D) Liquid (flare) Piping connections Gas (flare) Drain Heat insulation External static pressure Pa phase, 0-0 V/0-0 V, 0/0 Hz 00 () 7 () 8 () 7 () 8 () 7 () 7// 8// //9 //9 steps, quiet and automatic Microcomputer control 8 () //9 7 () 7 0 ø. ø ø.7 ø ø.7 VP 0 (External Dia. /Internal Dia. 0) Both liquid and gas pipes 0 00 () 00 () 7// 7// 7 7 () 7 () 8// 8// 00 x 900 x 0 00 x,00 x 0 00 x 900 x 0 00 x,00 x 0 Note: * The operation sound level values represent those for rear-suction operation and an external static pressure of 0 Pa. Sound level values for bottom-suction operation can be obtained by adding. 0

Wall-mounted type Floor-standing type only FTKS0KVMA FTKSKVMA FTKSKVMA FTXS0KVMA FTXSKVMA FTXSKVMA FVXSKVA FVXSKVA FVXS0KVA supply phase, 0-0 V/0-0 V, 0/0 Hz supply phase, 0-0 V, 0 Hz Front panel colour White Front panel colour White /s (cfm) () 88 (99) () 7 (7) 88 (99) 9 (0) /s (cfm) 7 (90) 7 () (00) 7 () 78 (78) 97 (7) Sound level (H/L/SL) 8// // 8// 9/8/ // /9/ Sound level (H/L/SL) 8// 8// 9/7/ 9/7/ // // Sound power level (H) 8 8 8 Sound power level (H) 7 7 8 8 Fan speed steps, quiet and automatic Fan speed steps, quiet and automatic Temperature control Microcomputer control Temperature control Microcomputer control Dimensions (H x W x D) 9 x 800 x Unit dimensions (H x W x D) 00 x 700 x 0 9 0 9 0 Liquid (flare) ø. Liquid (flare) ø. Piping connections Gas (flare) ø Piping connections Gas (flare) ø ø.7 Drain I.D. ø.0/o.d. ø8.0 Drain ø0.0 Heat insulation Both liquid and gas pipes Heat insulation Both liquid and gas pipes Wall-mounted type Floor/Ceiling-suspended dual type only FTKS0KAVMA FTKS0KAVMA FTKS7KAVMA FTXS0KAVMA FTXS0KAVMA FTXS7KAVMA FLXSBVMA FLXSGVMA FLXS0GVMA FLXS0GVMA supply phase, 0-0 V/0-0 V, 0/0 Hz supply phase, 0-0 V/0-0 V, 0/0 Hz Front panel colour White Front panel colour Almond white /s (cfm) (9) 70 (7) 90 () (9) 70 (7) 70 (7) 90 () 90 () 8 (79) /s (cfm) (8) () (0) () 90 (0) 0 (7) 00 () () Sound level (H/L/SL) // // /7/ // //0 // // /7/ /7/ Sound level (H/L/SL) 7//8 7//9 8//9 9//0 7/9/ // 8//9 7/7/ Sound power level (H) 0 0 8 0 Sound power level (H) Fan speed steps, quiet and automatic Fan speed steps, quiet and automatic Temperature control Microcomputer control Temperature control Microcomputer control Dimensions (H x W x D) 90 x,00 x 0 Dimensions (H x W x D) 90 x,00 x 00 7 Liquid (flare) ø. Liquid (flare) ø. Piping connections Gas (flare) ø.7 ø.9 ø.7 ø.9 Piping connections Gas (flare) ø ø.7 Drain ø8.0 Drain ø8.0 Heat insulation Both liquid and gas pipes Heat insulation Both liquid and gas pipes