NABCO SENSORS ACCESSORIES. For AUTOMATIC DOORS

Similar documents
Acusensor 3. Instruction Manual

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

WIRELESS RAIN GAUGE WITH IN/OUT TEMPERATURE INSTRUCTION MANUAL

Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE

DESIGN EASY ADJUSTMENT

Buttons on remote controller

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

CONVENTIONAL FIRE ALARM CONTROL PANEL

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

The Power To Supply... All Your Electrical Products

Vista-20SEUL System Design Sheet


Smart Anytime, Safe Anywhere. Z-Wave Accessory Catalogue. The Power of Home Control in Your Hands

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

PRODUCT LYNC IoT 37. PRODUCT: LYNC IoT

GEZE AUTOMATIC DOOR SYSTEMS GEZE ACTUATION DEVICES AND SENSOR SYSTEMS PERFECTLY CONTROLLED AUTOMATIC DOOR DRIVES BEWEGUNG MIT SYSTEM

modular system system Manufacturer: BRW sp.z o.o

Alarm System SECURE AS 302

F1 Smart Home Security Sensors. Unlocking the Potential of Your Wireless World

The Power To Supply... All Your Electrical Products

Vista-10SE System Design Sheet

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

The revolutionary code-free system as easy as

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Vista-50P/-50PUL System Design Sheet

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

POWER SOURCES MODEL NO. DESCRIPTION PRICE

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FT-EPB Series. Single Motor

Gas Safety Products. Installation, operating and maintenance 11/26/2015. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

1 Exam Prep Understanding and Servicing Alarm Systems Tabs and Highlights

5900 SERIES Low Energy Power Operator

Mini Product Guide.

Intelligent Wireless GSM Alarm System

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

IP65 High Bay Dual Sense Sensor

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

LED LANDSCAPE LIGHTING

Installation Instructions

Active Infrared Sensor OA-EDGE1/EDGE2. to the sensor module d4 = Distance from the pivot edge to the sensor module n = Number of sensor modules h

Single Door 39.5 Right Hand Push AL. Double Door (Twin) 75.5 Push AL Simultaneous 92 Push 11 + reveal BZ Independent Max reveal on a pull 2.

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

Intelligent addressable fire alarm control panel

GEZE AUTOMATIC DOOR SYSTEMS GEZE ACTIVATION DEVICES AND SENSOR SYSTEMS PERFECTLY CONTROLLED AUTOMATIC DOOR DRIVES BEWEGUNG MIT SYSTEM

System Guide.

PolyGard 2-channel Gas Controller MGC-03

BSR Addressable Fire Detection control panel. Installation operation manual

SP-1000X. Panic Device Power Controller Installation Guide. Rev

TRUST WIRELESS ALARM SYSTEM 200S

IP65 High Bay Dual Sense Sensor

DD205RF/TX Detector Installation Sheet

CONTROL YOUR HOME FROM EVERYWHERE

L O D G I N G S Y S T E M S

Car Design. Contents. Design. Car. Hall Design. Observation Cars NEXIEZ - MRL Only. Materials and Colors. Ceiling Variation & Car Finish 3-10

Split System, 18,000-48,000 Btu/h Underceiling Type MCC Series 50 Hz

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Model 17A00 Expansion Enclosure

Intelligent technology made simple

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

2. Pictographs 2.1 Basic Operation

MKTCTBLEFURTINC R001. Catalogue nd Edition

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Installation Instructions

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

DS160/161 Request To Exit PIR sensors Installation Instructions

Photoelectric Beam Detector

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

INFRARED MODULATED BARRIERS

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

1. Basic safety information 3 2. Proper use 3

Contents. Principle. Ceiling Design Signal Fixtures. Interior. Hall Design. Observation Cars NEXIEZ - MRL only. Materials and Colors

DS160/DS161 Request To Exit PIR sensors Installation Instructions

Ring Alarm Kit Base Station, Key Pad, Contact Sensor, Motion Detector, Range Extender

DUAL OPTIC. Installation manual

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Microprocessor Based 16 Channel Temperature Scanners (Product Code 7.2 To 7.3) MSI-16-H

BEA, Inc. Microwave Detector. Infrared Detectors. Time Delays/Security Modules. Accessories

PIR MOTION SENSOR. PIR Motion Sensor (EKMB, EKMC, AMN2, 3)

RTD-10 Installation Instructions

Advanced DIGITAL Wired PIR Motion Detector

CALL YOUR SALES CONSULTANT TODAY,

Ultrasonic Proximity Sensor

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

Hardwired Alarm Accessories

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FST-EPB Series. Single Motor

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

LC1350 Level Controller

BRIGHTEN YOUR LIFE. LED Troffer Light. Benefits. RoH S BB-RTGD-XXX-A-XX-D

WIRELESS RAIN GAUGE WITH IN/OUT TEMPERATURE INSTRUCTION MANUAL 1. INTRODUCTION 2 2. INSTALLATION 2

EXD-SH1/2 Controller for EX/FX/CX with ModBus Communication Capability

SERVICE REPORT REPORT SUMMARY OPTIONAL ITEMS. 1 P a g e TECHNICIAN: BOB WILDER SERVICE ADDRESS: 3047 N LINCOLN AVE SERVICE DATE: 12/2/2015

EXPANDABLE SMART HOME SECURITY KIT

Transcription:

NABCO SENSORS ACCESSORIES For AUTOMATIC DOORS

Accurate Eye of Microcomputer Importance of Sensors Transom mount Line up of sensors Ceiling mount NABCO sensors Transom embedded

and accessories ACCESSORIES Symbols Near-infrared sensor Detects persons and objects by the reflection of infrared New technology applying high sensitive active sensor Microwave sensor Detects moving persons and objects by the reflection of microwave Ultrasonic sensor Detects persons and objects by the reflection of ultrasonic wave and can be used as a support sensor Photoelectric beam sensor Is applicable to wide range of usage from a activation sensor to a support sensor Program switch Allows easy selection of the most suitable door operation Touch sensor Is mounted on the door or wall and operated by pushing the plate Electric lock Secures an entrance with low operation sound Mullion / Jamb Emergencyoperating system Operatesthe door at a power failure or when it receives an emergency signal Sensors mounted on the transom, ceiling Sensor is observable Embedded Sensors embedded in the ceiling, wall, mullion A part of sensor is obserable Door (Swing door) Colors CL Clear W White DG Darkgray Door or /Wall HL M BK Hairlinefinishing S Silver Mirror BZ Bronze Black SUS Stainless Steel Actualcolorsmaybe different fromthisbrochure.

NET-DS sensors NH-N600 PALSEARCH Detectionarea Mass250g D C1 C7 C6 B7 C5 B6 A7 C4 B5 A6 C3 B4 A5 C2 B3 A4 B2 A3 B1 A2 A1 W Max. 3.2m (3.0m at High-touch mode) Max. W 3.0m x D 2.1m [at mounting height 3.2m] 12VDC ± 10% 75mA or less NET-DS connector S BZ W M BK SUS Detectionarea size (reference value) Mounting height (m) Depth (m) Width (m) Setting 1 (C) Setting 2 (B+C) Setting 3 (A*+B+C) Setting 4 (A**+B+C) Setting 5 (A***+B+C) H=2.2 H=2.7 H=3.2 0.2 0.2 0.3 0.5 0.6 0.7 0.8 1.0 1.2 1.1 1.3 1.6 1.5 1.8 2.1 0.2 to 2.2 0.2 to 2.6 0.3 to 3.0 Preset of sensor types at PDA NH-N400 PALSEARCH Mounting hole 130 Detectionarea 200mm Ceiling thickness 0.1 ~ 50 75 Mounting height 8 Embedded Mass :350g Max. 4.0m Max. W 3.3m x D 2.0m [at mounting height 4.0m] 12VDC ± 10% 75mA or less NET-DS connector S 15 0 Detectionarea size (reference value) Mounting height (m) 2.4 4.0 MAX. 4.0 D Max. detection area (m) W2.2 x D1.2 W2.7 x D1.5 W3.3 x D2.0 W

Configuration of NET-DS System Non NET-DS switch Non NET-DS sensor Automatic sliding door Non CAN wiring NET-DS sensor NET-DS sensor Extended adapter adding contact input /output CAN transmission network Electric lock Lock Controller * Bluetooth wireless connectivity ** NET-DS Handy Terminal, for setting NET-DS System Controller for Door operator Door operator * Bluetooth Communication adapter ** NET-HT an application for PDA Standby Activating Standby

TRANSOM MOUNT NH-60 PALSEARCH Mass235g Detectionarea (mm) Max. 3.0m Max. W 2.5m x D 2.0m [at mounting height 3.0m] 12V to 100VAC/DC ± 10% 3.0VA or less (at 100VAC), 70mA or less (at 12VDC) Semiconductor relay output 400VAC[peak]/DC 0.12A or less (resistance load) S BZ W M BK SUS 2000 2500 3000 NH-605 ALPHA SEARCH Mass240g Max. 3.0m Max. W 3.0m x D 2.0m [at mounting height 3.0m] 12V to 100VAC/DC ± 10% 3.0VA or less (at 100VAC), 80mA or less (at 12VDC) Semiconductor relay output 100VAC/DC 0.1A or less (resistance load) Open collector, 50VDC 0.1A (resistance load) S BZ W M BK SUS Detectionarea (mm) 3000

ND-602 HYBRID SENSOR Mass320g Detectionarea (mm) Microwave Doppller method and Active Near-Infrared reflection (Motion and Presence Detection) Max. 3.0m [Microwave] Max. W 5.0m x D 2.6m [at mounting height 3.0m] [Infrared] Max. W 3.3m x D 0.9m [at mounting height 3.0m] 100VAC ± 10% 5VA or less (at 100VAC) : Semiconductor relay output 100VAC/DC 0.1A or less (Resistance load) : Semiconductor relay output 50VAC/DC 0.1A or less (Resistance load) S BZ BK 3000 NH-502 PALSEARCH 141 16 7 56 61 65 10 3 36 3.4 3.6 Mass80g Detectionarea (mm) Max. 2.5m Max. W 2.8m x D 1.4m [at mounting height 2.5m] 12VDC ± 10% 60mA or less Open collector, 50VDC 0.1A (resistance load) S BZ W BK 1400 2800 2500

TRANSOM MOUNT SSP-1 SUPER SENSOR SSP-12 SUPER SENSOR Max. 3.2m Max. W 3.5m x D 2.6m [at mounting height 3.2m] 12V to 110VAC/DC ± 10% 3.8VA or less (at 100VAC), 120mA or less (at 12VDC) No-voltage relay contact 1a, 50VDC/0.1A (resistance load) S BZ W M BK SUS Embedded Detectionarea (mm) 3200 Mass250g The detection area can coverthe door way. Mass300g CEILING MOUNT NH-400 PALSEARCH Detectionarea Mounting hole 130 200mm Ceiling thickness 0.1 ~ 50 75 8 Mounting height 15 0 Mass :370g D W Max. 4.0m Max. W 3.3m x D 2.0m [at mounting height ht 4.0m] 12V to 100VDC ± 10% [12V to 100VAC ± 10%] 70mA or less (at 12VDC) [3W or less (at 100VAC)] Semiconductor relay output 100VAC/DC 0.1A or less (resistance load) Detectionarea size (reference value) Mounting height (m) 2.4 4.0 MAX. 4.0 Max. detection area (m) W2.2 x D1.2 W2.7 x D1.5 W3.3 x D2.0 Embedded S

TOUCH SENSOR / SWITCH NH-604 HIGH-TOUCH SENSOR Max. 3.0m Combination : Max. W 3.0m x D 2.0m [at mounting height 3.0m] Touch : Max. W 1.0m x 0.15m 12V to 100VAC/DC ± 10% 3.0VA or less (at 100VAC), 70mA or less (at 12VDC) Semiconductor relay output 100VAC/DC 0.1A or less (resistance load) S BZ W M BK SUS Mass240g Sticker 1 2 3 4 NW-800 / HW TOUCH SWITCH NW-800 Transmittal plate NW-800 TOUCH SWITCH HW-40TE/4SE English and Japanese English Pressure detection (Plate) Receiver : 12V to 100V AC/DC ± 10% Transmitter : AAA Alkaline battery Subsidiary plate HW-40TE Transmittal plate Subsidiary plate HW-4SE Receiver : 2VA or less (at 100VAC), 50mA or less (at 12VDC) Transmitter : 8mA or less Semiconductor relay output 100VAC/DC 0.1A or less (resistance load) DG HW-41T Transmittal plate Receiver : Subsidiary plate HW-41S HW-41T/41S English and Japanese 2VA or less (at 100VAC), 60mA or less (at 12VDC) Transmitter : 4mA or less No-voltage relay contact 1a, 50VDC / 0.1A (resistance load) S NW-800 HW AUTO DOOR PUSH TO OPEN Mass120g/65g Mass130g/110g

SUPPORT SENSOR BEAM and ULTRASONIC SENSOR NP-10B/NP-10LB BEAM SENSOR NP-10B / NP-10LB Embedded NP-10B NP-10LB Between photocells Between photocells 0.9m to 5.0m 5.0m to 8.0m CL CL MassNP-10B 120g NP-10LB 230g NZ-1 ULTRASONIC SENSOR NZ-1R NZ-1U NZ-1H NZ-1R NZ-1U(A=14) NZ-1H(A=40) Mass50g/60g/65g Detectionarea (mm) Embedded Ultrasonic reflection still object detection method NZ-1R, NZ-1U : Max. 2.5mNZ-1H : Max. 3.0m NZ-1R, NZ-1U : Max. 1.5mNZ-1H : Max. 1.3m 100VAC ± 10% 4.0VA or less No-voltage relay contact 1a, 50VDC/0.1A (resistance load) NZ-1R S BZ NZ-1U NZ-1H S BZ HL M Model NZ-1R NZ-1U NZ-1H Detection area (mm) D=1500 D=1500 D=1300

SIDE BEAM SENSOR / DOOR MOUNT SENSOR NH-101 SIDE BEAM SENSOR Mass120g Detectionarea (mm) NH-101 SIDE BEAM SENSOR Near Infrared method (Perfect Presence Detection) 0.5 to 1.5m 12VDC ± 10% 50mA or less Open collector, 50VDC 0.1A (resistance load) BK S BZ NH-202 ACUGARD NH-202 ACUGARD Near Infrared distance surveying (Presence Detection only) 1.7m to 2.5m 12V to 24VDC ± 10% or 24VAC ± 10% 3.0VA or less (at 24VAC), 85mA or less (at 12VDC) Semiconductor relay output 50VAC/DC 0.1A or less (resistance load) BK Mass1,500g

ACCESSORIES NEW EL-01U / EL-01L ELECTRIC LOCK Control unit Main unit 57 208 126 64 Mass900g EL-01U EL-01L Fail-safe (Unlock at power off) Fail-secure (Lock at power off) Available (Option) 100VAC ± 10% 50/60Hz Operation: 0.6A, Holding: 0.3A (at 100VAC), Max. 30mA (at 12VDC) SKD-2 ELECTRIC LOCK 56 (11.7) Lead wire 167 38 SKD-2US ELECTRIC LOCK MassSKD-2U/SKD-2US1,000g SKD-2 L /SKD-2LS1,100g SKD-2U SKD-2US SKD-2UE SKD-2UES Fail safe (Unlock at power off) Available 1000N more SKD-2L SKD-2LS Fail secure (Lock at power off) Lock: 2.0s or less / 0.7s or less, Unlock: 0.6s or less/ 0.3s or less Lock: 3.0 to 0.7s, Unlock: 0.7s to 0.3s (for NET-DS Lock controller) Over 1,000,000 times

PL-1U PULLEY LOCK PL-1U PULLEY LOCK Fail safe (Unlock at power off) Approx. 800N Replaced with idler pulley Mass1,300g APS-N1 / APS-1 ADVANCED PROGRAM SWITCH APS-N1 NET-DS controller 12VDC±10 75mA or less Passcode APS-1 DS controller 50mA or less Door operation mode Mass270g AUTO The door operates as a normal automatic door. OPEN The door opens and holds the full (partial) open position.useful when moving cargo through the door. ONE-WAY When the door is in a closed position, only the indoor sensor is activated. CLOSE The door closes and all sensors are deactivated. FULLOPEN The door operates at the normal opening width. PARTIALOPEN The opening width is partial. Useful in cold weather or during heavy wind / rain conditions.

ACCESSORIES EOS EMERGENCY OPERATING SYSTEM 370 27.4 313.2 R-N150 EOS CONTROLLER 65.3 43.5 33.5 48.6 12 Mass500g 230 173.2 65.3 43.5 33.5 48.1 BATTERY UNIT EOS Emergency Operating System 100V AC±10V, 50/60Hz, 5A Ni-Cd rechargeable battery -10 to 50 degrees Celsius Panic-open or panic-close No-voltage contact input / 24VDC input 30 times or 30 minutes operation Approx. 12 hours Mass600g DS TRANSFORMER L=200 OUTPUT L=200 INPUT 64 Max.63 98 118 2 Max.84 Mass1,500g DS DOWN TRANSFORMER 220VAC, 50/60Hz 100VAC, 1.0A

Sensor list of NABCO automatic door Notes concerning sensor detection area for NABCO automatic door

Cautions for safe operation When using automatic door Don't halt! 1 2 Don't run in! 3 4 Don't lean on the automatic door! Don't play near automatic door! 5 Accompany your children! Pay attention to the door! 6 NABCO Company