Discover how much Water You re Using and Use that Information to Optimize Your Facility

Similar documents
Energy / Temp / Flow Monitoring with Ultrasonic Flow Meters

Passive House Northwest AIA CEU Provider. Aubrey Gewehr March 27, 2015

Water is a resource shared by all, and as Florida s population increases, so does the need for all of Florida s residents to conserve.

LED Lighting: Technology Selection and System Commissioning Course Number: CXENERGY1519

Richard B. Alpert, P.E. Senior FPE, Clark Nexsen

Hot Water a Hot Commodity Better Buildings by Design, February 2012 Burlington, VT

Green and Gray Infrastucture

Design for New Construction and

WATER WISE SURV EY. Santa Barbara City College

Welcome! AIA/CES Approved Seminar 1.0 LU/HSW. RAB8: Specifying a Networked Lighting Control System

Convergence: The Integration of Lighting and Micro Sensor Technology

MA Electric Code Challenges for Architects

FCSI Conference April 20 th and 21 st Presentation by: Richard Young Senior Engineer and Director of Education

Case Study: Furman University Charles H. Townes Center for Science. Michael K. Mantai, PE, CCP President System WorCx

Questions related to specific materials, methods, and services will be addressed at the conclusion of this presentation.

Stage 1 Drought Restrictions Lifted

End-Use Data Collection Requirements Data Trend Type

Every Drop Counts: Conserve WATER. Pamela R. Turner, Ph.D. Laurie Cantrell, MHS Winter School - January 22, 2008

Compliance with Lighting Standards and Management Systems (ANSI C137)

Beyond the Great Debate: Assessing Post Installation Manufactured Soils Performance

WHERE THE WATER IS FLOWING

2016 Annual Conference

Open to Below: A Discussion of Allowed Floor Openings. Jay A. Ierardi, Ph.D., P.E., LEED AP. Kevin S. Hastings, P.E., LEED AP

Impact of Minimum Fan Efficiency Grade. Dr. John Cermak Executive Vice President ACME Engineering and Manufacturing Corp.

YEARLY VIEW. 6/28/2016

Common Building Code Misinterpretations

Conduct your own water audit!

111 Ways of Conserving Water in Your Home

Fixing leaks and installing a few inexpensive water-saving devices in

What Is Retrofit? Most retrofit devices will reduce your water and sewer bill enough to pay for themselves within six months.

Sizing Guide. For the Estimating of Flow Rates and Water Usage

Efficiency Vermont The American Institute of Architects Continuing Education Systems (AIA/CES) AIA/CES AIA/CES

Waterwise Rainwater Saving Guide

Yakima Health District 1210 Ahtanum Ridge Drive Union Gap, Washington Phone (509) Fax (509)

Steven Winter Associates, Inc. J827

Modified Everitt-Jennings (MEJ) Method and the Gibbs Method: Downhole Card Comparison

The Public Architect as City Builder

TYPICAL WATER SERVICE INSTALLATION SPECIFICATIONS AND REGULATIONS

Sprinklers in Wood-Frame Construction:

FORM ACCL-PC1 ACCL WITNESS TEST PROCEDURE AND CHECKLIST

Emerson s Pervasive Sensing strategies enable plants to realize full potential of Industrial IoT

RAINWATER HARVESTING. An Overview of Rainharvesting Systems

PRESSURE SEWER SYSTEMS GUIDE FOR HOME OWNERS AND BUILDERS

National Grid s Direct Install Program for Commercial Customers

Water Conservation Information. Regarding water well pump selection

SPOTLIGHT ON WATER CONSERVATION

Sanitary Drainage Systems

WATER SAVING TIPS SAMPLE. for Your Home

Appendix A. Glossary of Common Terms

Building Analytics and Compliance: How analytics can be used to aid in performancebased certifications. Bryant M. Kirkland Jr, PE, CCP, LEED AP

2015 IRC Significant Changes For Mechanical and Fuel Gas with LSUCCC Amendments

Cool Savings Program Report

June Copyright Climatec

Hot Food Holding Cabinets Test for FWE HLC

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

WATERSMART GUIDEBOOK. A Water-Use Efficiency Plan Review Guide for New Businesses

Softened Water Benefits Study: Energy Savings Detergent Savings. Independent studies demonstrate the link. Executive Summaries

LEAK GUIDE HOW TO IDENTIFY COMMON PLUMBING LEAKS

Engelska English. Help us economise on. our precious water! Tips and information on saving water in the Municipality of Eksjö

Welsh Commissioning Group, Inc.

Southwest Florida Water Management District. Saving Water INDOORS

White Paper. Fog Detection and Defog Technology. hanwhasecurity.com

Modular Construction. Live/Work Urban Infill Townhome. Modular Construction. Enclosure Design. San Francisco Bay Area Net Zero Urban Infill

Roofing Industry Update. Welcome!

Your floor to ceiling guide

Pipe Sizing Table. Hydraulic Load Served (fixture units)

DHR Accessories Requirements. Site Preparation Guide

BNWAT28: Water consumption in new and existing homes

Water Conservation Tips

How Green Contractors Can Go

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South

COMMERCIAL PERMIT APPLICATION AND CHECKLIST. Depending on the scope of your project, the following submittal requirements will apply:

WATER CONSERVATION TOOLS AND TIPS R E D U C I N G W A T E R U S E S T A R T S W I T H U S!

Water Conservation. Fact Sheet

Wastewater. Guidelines for Sizing mscdirect.com. Call MSC today to learn about the latest LittleGiant products.

Water Appliance Stock Survey and Usage Pattern Melbourne 2012

Historic Preservation s Future : Willowbank School of Restoration Arts. Lisa Prosper

*Put a sign at each sink in the office and in bathrooms "Please turn off the water when not in use"

Byrd Barr Place PSE HELP Program:

Boil Water Emergency Action Plan

Estimating Water Use and Savings in Your Home

RESORT MUNICIPALITY OF WHISTLER OUTDOOR POTABLE WATER USAGE BYLAW NO. 2179, 2018 A BYLAW TO REGULATE THE USE OF OUTDOOR POTABLE WATER

UL's Effort to Harmonize Product Safety Requirements for A2L, A2, and A3 Refrigerants. San Antonio, Texas 2012 Annual Conference

How to Heat Water in All-Electric Homes & Apartments?

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Mayor s Neighborhood Summit

Focused Evaluation of Rainwater Harvesting: A Case Study in Sandakan, Sabah, Malaysia

2. No plumbing fixture shall be replaced with fixtures which allow greater water use. C. Residential Water Efficiency Standards for New Structures.

Aspe Domestic Hot Water Heating Design Manual Pdf

House Efficiency Survey Report

Prescriptions for Critical Healthcare Cx. John D. Villani, P.E. Associate Grumman/Butkus Associates

BACKFLOW PREVENTION GUIDE FOR COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL DEVELOPMENTS

Energy Management and Controls

TIPS ENERGY THE LESS YOU USE, 65 WAYS TO REDUCE HOME ENERGY USE THE MORE YOU SAVE CONSERVATION

Copyright 2017 by Eddy Home Inc. All Rights Reserved.

By Thomas H. Durkin, P.E., Member ASHRAE, and James B. (Burt) Rishel, P.E., Fellow/Life Member ASHRAE

Sensor Cloud User Manual

REGULATIONS GOVERNING WATER SERVICE TO CUSTOMERS OF THE EAST BAY MUNICIPAL UTILITY DISTRICT SECTION 31 WATER EFFICIENCY REQUIREMENTS

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

Conducting Residential Cross Connection Inspections

Transcription:

AABC Commissioning Group AIA Provider Number 50111116 Discover how much Water You re Using and Use that Information to Optimize Your Facility Course Number: CXENERGY1704 Brent Baird Instruments Direct April 26, 2017

Credit(s) earned on completion of this course will be reported to AIA CES for AIA members. Certificates of Completion for both AIA members and non-aia members are available upon request. CES for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or dealing in any material or product. Questions related to specific materials, methods, and services will be addressed at the conclusion of this presentation. This course is registered with AIA

SAMPLE OPTIONAL SLIDE Copyright Materials This presentation is protected by US and International Copyright laws. Reproduction, distribution, display and use of the presentation without written permission of the speaker is prohibited.

Course Description The question all balancers need to answer is how much water are we using. Without this critical data, there is no basis to adjust or balance a hydronic system. This session explores the different water applications in a typical facility and breaks down the technologies on how to monitor the flow and energy from both a flow survey discovery process and a long term dedicated metering solution.

Learning Objectives At the end of the this course, participants will be able to: 1. Learn about different water application inside a typical facility. 2. Learn about hydronic requirements and effect. 3. Learn about the performance and limitation of old metering equipment as well as the flow meter tool to better balance and commission a facility. 4. Learn about technologies and tools to optimize your facilities water usage.

How much water does the average person use at home per day? Estimates vary, but each person uses about 80-100 gallons of water per day.

How much water do you use? Bath: 35 to 50 gallons of water. Larger units, soaking tubs or freestanding tubs, 60 to 80 gallons of water

How much water do you use? Shower: 5 gallons per min, water saver head is 2 gallon per min

How much water do you use? Toilet flush: 3 gallons. Newer toilets use 1.5 gallons.

How much water do you use? Dishwasher: Newer energy efficiency 6 gallons, older up to 16 gallons. Dish washing by hand: 8 27 gallons

How much water do you use? Office Buildings, Commercial & Institutional Facilities in the USA account for 17% of the public water supply. Example hotels, restaurants, office buildings, schools, hospitals, laboratories, government and military institutions.

How much water do you use? Office Buildings 40% 35% 30% 25% 20% 15% 10% 5% Office Building Water Usage 0% 1 Kitchen Domestic/Restroom Cooling & Heating Landscape

How much water do you use? Hospitals Hospitals Water Usage 40% 35% 30% 25% 20% 15% 10% 5% 0% 1 Kitchen Domestic/Restroom Cooling & Heating Landscape Med Eqpt Laundry Other

How much water do you use? Hotels Hotels Water Usage 35% 30% 25% 20% 15% 10% 5% 0% 1 Kitchen Domestic/Restroom Cooling & Heating Landscape Pools Laundry Other

How much water do you use? Restaurants 60% 50% 40% 30% 20% 10% Restaurants Water Usage 0% 1 Kitchen Domestic/Restroom Cooling & Heating Landscape Other

How much water do you use? Educational Educational Water Usage 50% 40% 30% 20% 10% 0% 1 Kitchen Domestic/Restroom Cooling & Heating Landscape Pools Laundry Other

How much water do you use? Industrial Industrial Water Usage 50% 40% 30% 20% 10% 0% 1 Kitchen Domestic/Restroom Cooling & Heating Landscape Pools Laundry Other

How much water do you use? Reason for monitoring Inventory - How much water are you using - Control or regulate a regulation - Control a manufacturing process Billing - Support water distribution infrastructure - Submetering - Enforce usage / regulations

How do you determine the efficiencies of your current system? Discover Process Use a reference flow meter to establish a baseline and map out your sources: -Hot and Chilled water -Temperature (Differential) BTU You need a Tool to Measure your water usage.

Ultrasonic Flow Meters THE SOUND'S TIME OF FLIGHT IS ACCURATELY MEASURED IN BOTH DIRECTIONS AND THE DIFFERENCE IN TIME OF FLIGHT CALCULATED.

Ultrasonic Flow Meters

Sound Speeds The speed of sound c is given by the Newton-Laplace equation: C is a coefficient of stiffness, the bulk modulus (or modulus of bulk elasticity), ρ is the density. Therefore the speed of sound increases with the stiffness of the material, and decreases with the density.

NOTE ON WATER/GLYCOL APPLICATIONS Sound speed of Water 4,908 fps @25 deg C Typical mixture of 30% Glycol and 70% water. Sound speed of Glycol 5440 fps @25 deg C 30% Glycol = 1,632 fps 70% Water = 3,435.6 fps Total 5,067.6 fps <10% change on Sound speed Just Program the sound speed for Water.. Most new technology meters auto adjust for optimal Sound Speed.

Bulk Modulus The bulk modulus K can be formally defined by the equation: where P is pressure, V is volume, and P/ V denotes the partial derivative of pressure with respect to volume. The inverse of the bulk modulus gives a substance's compressibility.

Flow profile : Single (Z) path, Symmetrical

Flow profile : Single (Z) path, Symmetrical

Water Meters Type of water you want to monitor Potable - Potable water meters need to be NSF/ANSI 61 compliant. - Application: Clean water. Cold and hot water. Example: Drinking, edible, etc.. Non-potable - Application: Clean/Dirty, can contain solids or slurries. Example: Irrigation, chilled water, wastewater, process chemicals and more.

Ultrasonic Flow Meters Applications Industrial / Manufacturing Agricultural Food / Beverage Government / Municipal / City / County Commercial Residential Submetering Private - Fido s water dish

Using Portable Ultrasonic Meters Discover process. Spot check flows Water usage study Energy usage study Balancing Hydronic system Economics

Program meter with application details Determine Transducer site Pipe/Transducer Preparation Adjust Transducer spacing Install Transducer to Pipe Adjust transducer knobs until sensors are snug to pipe surface.

Water Meters Is my current water meter accurate?

Building City Water / Influent City Water Meter M Test Meter Flow E-1 Pump

Submetering????????

Data Storage Data Collection Log flow rate, total & Energy (BTU) Save to SD card or down load to PC Now you can adjust, graph, copy or export your files.

Facilities Water usage Flow Study

Chiller Blow Down Facilities Drawoff (or Blowdown) Blowdown

Facilities Drawoff (or Blowdown) Blowdown Trap

Facilities Water usage Leak Detection

Energy Monitoring

Temperature sensor mounting Mount the RTD temperature sensors in the identical location on the supply and the return (metal) pipes. Failure to-do so will result in temperature differentials that can effect your performance of the BTU calculations

Dedicated Metering / Submeter Ultrasonic Transit time Flow Meters

New Technology Meter Data Collection Cloud Dash Board Wi-Fi Network Algorithms Details Learn your application provide decision making information

Summary: Clamp-on Ultrasonics, important tool for monitoring water usage, hydronic balancing & commissioning. New technology and lower cost will enhance submetering. More submetering will expand the number of meter test points. Better Data Saves Water & Energy.

This concludes The American Institute of Architects Continuing Education Systems Course Contact Information: Brent Baird Instruments Direct p(888)722-5543 bbaird@instrumentsdirect.com