Instructions for use / Alarm unit, Fiber optic cable & Sensor patch ENGLISH

Similar documents
Enhance DX. Mattress Replacement System. User Manual

COOLFLOW IRRIGATION PUMP USER MANUAL

Veterinary Patient Warming System Controller User Manual

TM Machine WetAlert TM Wireless Wetness Detector Home User s Guide

CLETEF-786. Infrared Thermometer Instruction Manual

ULTRASONIC AIR SALINIZER. Owner s Manual. Saltair Home Salt Therapy

PEAK Platelet Rich Plasma System

Veterinary Patient Warming System Service Manual. For information on operating the Hot Dog Patient Warming System, refer to the Instructions for Use

Transcend Heated Humidifier User Manual

Operator s Manual. WarmTouch. Model WT-5900 Patient Warming System

Instruction Manual Mini SAD Light Box Code: A54LC

Operator s Manual. WarmTouch. Model WT-5300A Patient Warming System

CONTENTS IMPORTANT SAFEGUARDS INTRODUCTION PRODUCT DESCRIPTION INSTALLATION OPERATIONS CLEANING...

User Manual. Mistral-Air Plus Warming Unit. MA1100-EU ( V~, 50/60 Hz) MA1100-US ( V~, 60 Hz) MA1100-JP ( V~, 50/60 Hz)

Directions for use MACH LED 300DF

ASPIRE Laboratory Aspirator

HydraTherm TM OPERATION MANUAL

EkoSonic Control Unit Instructions for Use

Owner s/service Manual. LED Light Source for A-Series TM. Microscopes M A801-LED

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

RESmart CPAP System. User Manual

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

OPERATION MANUAL. Multi Function Ultrasonic Scaler. Varios 970. Please read this Operation Manual carefully before use, and file for future reference.

MaxiCompressor. Limited Warranty. High Performance 50 PSI Compressor 501-S

Instructions For Use

micomme, Sepray,, are registered trademarks of Micomme Medical Technology Development Co., Ltd. All rights reserved. Modes: Sepray CPAP 25,Sepray CPAP

Important user information

BNT-1000 Infant Radiant Warmer Operate Manual

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

CARESTREAM DRX-1 System

5. Instrument and accessories discharging must be done following current law regulations in every country of use.

CVX-300 Excimer Laser System. Gen 4.0 Operator s Manual

STS Directory Accreditation number: STS 0009

Bio Compression s SC-3004-DL

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Model IC-1545-DL Multi-Flo DVT Combo

CARESTREAM DRX-1 System Detector CARESTREAM DRX-1C System Detector CARESTREAM DRX 2530C Detector Model DRX User Guide

Companion 5. Oxygen Concentrator PROVIDER TECHNICAL MANUAL

CVX-300 CVX-300 -P Excimer Laser System

INTERNATIONAL STANDARD

WARNINGS AND PRECAUTIONS FOR THE USE OF THE IQ TM Intelligent Driver

Compliance Engineering Ireland Ltd

REMstar SE USER MANUAL

INFUSION PUMP J1060MN OPERATOR MANUAL

SC-3008-DL SEQUENTIAL CIRCULATOR

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

User Instruction Manual

OPERATION & CARE MANUAL FOR P-2010-S BLANKET WARMING CABINET

NPWT PRO and PRO to GO PATIENT USER MANUAL

Compliance Engineering Ireland Ltd

INTERNATIONAL STANDARD

This is a preview - click here to buy the full publication

Instructions For Use SC-2004-OC, SC-2004FC-OC and SC-2008-OC. Sequential Circulators

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Dear customer, Be sure to use the device properly according to the instructions given by medical professionals.

User Instruction Manual

Patient Warming System Controller Model WC5X Service Manual

SUCTION PUMPS CareLinc Home Medical Equipment and Supply, LLC SS170CE00101

IB-CB200GB _Layout 1 16/12/ :02 Page 1. Instruction Manual. Customer Service Number +44 (0) CB-200-GB


OPERATORS GUIDE Rocket R54569 PSU

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

MyKi Care Thermometer (MCT 1.0) USER MANUAL

Tesla M3. MRI Patient Monitoring System. Instructions for Use. Version 4.0

Regulatory Information and Specifications

User Manual. Advanced Markus Chamber Ionization Chamber Type 34045

Iron - low. - medium - high Do not iron. Bleach - chlorine. Do not bleach. Tumble dry - low - medium - high Do not tumble dry

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Neptune 2 Waste Management System

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Components of the device. Appearance of the device. ihealth thermometer User s manual LED screen. Manufacturer info. LED screen.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. F2 LABS Peters Road Middlefield, OH Wendy Fuster Phone: Ext.

Operating Instructions ATMOS LS 31 LED. English GA1GB Index 02

Portable Oxygen Concentrator Model: RS User Manual

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Titan Series Blanket Warmer

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CE EMC Test Report EN :2015 EN :2017. Folder with powerbank ZKS E. Lieber Ouyang (Engineer) Lahm Peng (Manager)

Elite Series Blanket Warming Cabinet

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SmokeCheck Operating Manual

Tesla M3. MRI Patient Monitoring System. Instructions for Use. Version 3.1

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

This symbol indicates an insulation class I device. This Symbol indicates a type B applied part. This symbol indicates alternate current

Flowtron ACS900. Instructions For Use. ...with people in mind INT1 Rev A - 05/2015

Blanket Warming Cabinet

AtmosAir Mattress Replacement System User Guide Instructions for Use

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Audible warning devices for external alarm

Operating Instructions

AUGUST 2016 CONTENTS:

Technical Service Manual KANMED Babywarmer BW3

Contents. Introduction...5. Chapter 1 Safety Precautions & Warnings Chapter 3 General Operations Chapter 2 Product Overview...

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Operating Manual. Kangaroo TM. 924 Enteral Feeding Pump with Pole Clamp

Transcription:

Instructions for use / Alarm unit, Fiber optic cable & Sensor patch ENGLISH

Manufacturer: Redsense Medical AB Gyllenhammars väg 26 302 92 HALMSTAD SWEDEN www.redsensemedical.com These instructions are released with the following date/version: 2014-02-20 Instructions RM-1RM188 Instructions Warnings and precautions 3 Mounting Redsense 5 During dialysis 7 After completing dialysis 7 Maintenance 7 Cleaning 7 Charging the battery 7 Replacing the battery 7 Symbols and terms 8 Technical Information 9 EMC Information 10 2

Warnings and precautions At this time, no hemodialysis equipment is cleared for Nocturnal HD treatment at home. Please refer to the hemodialysis equipment indication statement to confirm usage is consistent with its labeled indication. The Redsense device model RA-1-RA201 is is designed to detect potential blood loss from the needle access site during hemodialysis. Read and follow all instructions carefully. This piece of equipment is only an alarm. It does not replace existing safety procedures. Redsense may only be used for its intended purpose and according to these instructions. The alarm unit may only be placed on the dialysis machine as shown in the instructions. The alarm unit shall only be used with the proper AC adapter. The alarm unit may only be used by persons who have received proper training from Redsense Medical or who have been approved by Redsense Medical. Use by untrained or improperly trained personnel may pose a danger to the patient. Modifying the equipment is not permitted. Modification of the equipment will void all guarantees and product liability on the part of the manufacturer. Servicing of the equipment may only be performed by Redsense Medical or by persons authorized by them. External equipment intended for connection to signal input, signal output or other connectors shall comply with the relevant product standard e.g. IEC 60950-1 for IT equipment and the IEC 60601- series for medical electrical equipment. In addition, all such combinations systems shall comply with the safety requirements stated in the collateral standard IEC 60601-1-1 or the general standard IEC 60601-1, edition 3, clause 16. Any equipment not complying with the leakage current requirements in IEC 60601-1 shall be kept outside the patient environment i.e. at least 1.5 m from the patient support. Any person who connects external equipment to signal input, signal output or other connectors has formed a system and is therefore responsible for the system to comply with the requirements. If in doubt, contact Redsense Medical or your local representative. Redsense is a laser class I product. All use must be administrated under physician s prescription. and must be observed by a trained and qualified person, considered to be competent in the use of this device by the prescribing physician. Before use, a test must be performed to make sure the observing person can clearly hear the alarm signal. The test is further described at page 6 under point 9. This device should not be relied upon as the sole monitor for blood loss at the blood access site. Redsense requires special precautions in terms of EMC and must be subsequently used in accordance with the EMC information in these instructions. Portable and mobile radio communication equipment may affect Redsense. Redsense is not intended to be used in a highly oxygenated environment. 3

About Redsense alarm systems Redsense is an alarm system for monitoring the blood access during hemodialysis. The Redsense system consists of the following and can be used in combination with: Alarm unit, RA-1-RA201 AC adapter, RC-1-RC201 Fiber optic extension, RE-1-RE201 Sensor patch, RS-1-RS201 When the sensor patch is placed over the blood access, it detects any blood coming in contact with the sensor. This can occur if the needle is accidentally dislodged or if blood is leaking during dialysis. Indications For Use The Redsense device is intended to monitor for potential blood loss from the hemodialysis access site in hemodialysis patients undergoing hemodialysis treatment. The device includes a blood sensor incorporated into a sensor patch. The sensor monitors potential blood leakage from the venous needle blood access via a light signal and will alarm if blood leakage is detected by the device s sensor. 4

Mounting Redsense The Redsense sensor should be placed on the patient after the needles have been inserted and before dialysis begins. Redsense must be turned on the entire time that dialysis is running. 1. Attach the alarm unit to the dialysis machine s IV pole / drip stand (see figure 1). If this isn t possible please contact Redsense Medical for consultation. Connect the AC adapter to a wall outlet and to the black-colored connector on the alarm unit. (Figure 2 shows the connector.) 2. The alarm unit indicates as follows whether the built-in battery is charged: A flashing battery indicator light means that the battery is being charged. The unit cannot be started in this case. Wait until the charging is complete. A solid battery indicator light indicates that charging is complete and monitoring can begin. 3. Connect the optical extension fiber to the alarm unit. Turn the coupling roughly a 1/3 turn to lock it. Check that the coupling is locked (see figure 3). 4. Check the date on the packaging for the sensor patch and be sure that the packaging has a Redsense label on it. Open and check that the sensor patch does not have any mechanical damage. 5. In order to start Redsense, push the on/off button and check that all the indicator lights are on and the alarm signal can be heard. The alarm signal should be a continuous signal with three different levels/tones. Check that the patient s supervising staff can clearly hear this signal at the correct distance. The observing person must be sure that the alarm signal can be heard from other rooms or while there is noise. The observing person must be situated at places where the alarm signal can be heard during the entire dialysis treatment. If this isn t possible please consult Redsense Medical. figure 1 figure 2 figure 3 1 2 5

Mounting Redsense 6. To stop testing the indicator lights and the alarm signal, push the on/off button again. The green indicator light starts to flash together with a intermittent signal. 7. Connect the fiber from the sensor patch to the optical extension fiber. Open the connector on the end of the optical extension fiber by holding in the locking button, inserting the sensor patch fiber from the sensor patch until it stops/resists, then releasing the lock button (see figure 4). When the green indicator light is solid, and the intermittent signal is turned off the monitoring function is working correctly. 8. Make sure the area around the needle is dry. 9. Apply the sensor patch to the skin over the needle with the absorbent part of the sticker centered directly over the insertion point. Be sure that the self-adhesive part of the patch does not cover the wings (see figure 5). 10. Secure the needles in place as usual using tape or similar material. Secure the needles in place according to the existing policy and procedure. Dressing material and or tape may be applied directly over the surface of the sensor patch according to the facility policy and procedure. Figure 6 shows an example of how the sensor patch and the optical extension fiber can be attached to the patient s arm. Check that the sensor patch is clean and dry. 2 1 figure 4 figure 6 figure 5 YES YES NO 6

Mounting Redsense A flashing green indicator light indicates that the alarm unit is performing a self-test. During this test, a number of parameters are checked that may eventually need to be adjusted. These are displayed when the following lights and symbols appear: The yellow indicator light, which is marked with a warning symbol, can indicate any of the following: Moisture has come in contact with the sensor. The sensor has come loose, is not connected or has been broken. The optical extension fiber is not connected correctly. If all of the indictor lights are flashing, an internal error has been detected. Contact Redsense Medical for additional support. Any problems must be corrected before attempting to restart the alarm unit. If blood or moisture has come in contact with the sensor, it must be replaced with a new sensor. If some other technical problem occurs, do not use the alarm unit, rather switch to another Redsense alarm unit and contact Redsense Medical for additional support. During dialysis While the unit is running, the green indicator light will light up continuously, and in the event of an error the following alarm signals may be heard: The red indicator lights followed by a continuous alarm signal, indicate that blood has been detected by the sensor, either because the venous needle has been dislodged or leakage has occurred. First, deal with the leak and then turn off the alarm by holding in the button for at least 1 second. The yellow warning indicator light followed by an intermittent alarm signal indicates one of the fol lowing: Moisture has come in contact with the sensor. The sensor has come loose, is not connected or has been broken. The optical extension fiber is not connected correctly. Turn off the alarm by keeping the on/off button pressed, fix the cause of the alarm and then restart the alarm unit. The yellow warning indicator together with the battery indicator, followed by an intermittent alarm signal, means that the alarm unit is no longer receiving power from the AC adapter, which means that monitoring can no longer be performed correctly. In this case, turn off the alarm unit by keeping the button pressed in, then fix the cause of the AC power failure for the alarm unit. If all the indicator lights are flashing, followed by an intermittent alarm signal, this indicates an internal error. Turn off the alarm unit by holding in the button and continue running the dialysis without monitoring with Redsense. Contact Redsense Medical for additional support. After completing dialysis 1. Press the on/off button for at least 1 second to turn off the alarm. 2. Disconnect the sensor patch from the optical extension fiber. 3. Clean the optical extension fiber. 4. Remove the sensor patch and dispose of it according to the clinic s procedures for handling dialysis waste. Note: The alarm can also be turned off using the on/off button at any time during dialysis. Maintenance Cleaning The actual sensor patch is made of disposable material and should not be cleaned or reused. The alarm unit and the optical extension fiber should be wiped off with disinfectant/alcohol and a moist cloth. Charging the battery The alarm unit contains a battery in order to issue an alarm in the event of a power failure from the AC adapter. When the alarm unit is connected to the AC adapter, the charging status for the built-in battery is displayed as: A flashing battery indicator light means that the battery is being charged. The unit cannot be started in this case. Wait until the charging is complete. A solid battery indicator light indicates that charging is complete and monitoring can begin. Replacing the battery In order to replace the battery, the alarm unit must be opened and this can only be done during servicing. Servicing the equipment and changing the battery should only be done using Redsense Medical or by personnel authorized by them. 7

Symbols and terms The following symbols and terms are used in these instructions and on the product. Green indicator with operating symbol Connector for AC adapter (black) Yellow indicator with warning symbol Connection for optic fiber. On/off button Red indicator with alarm symbol Yellow indicator with battery symbol Service connector (blue, Redsense use only) Other symbols displayed on the product and its accessories indicate the following: SN Manufactured by Redsense Medical AB Sweden Last usage date, year-month (YYYY-MM) Alarm indicator On/off indicator LOT Batchnumber, includes manufacturing year Warning indicator REF SN Item number Serial number, includes manufacturing year Battery indicator Applied part of type BF Body Floating (the surface between the equipment and the patient does not conduct electricity) For single use only Consult the instruction for use The alarm unit covered by the WEEE directive and must therefore be recycled Consult warnings and precautions Class I laser product 1 Class II double insolation On/0ff-button The sensor has been sterilized using Ethylene Oxide (Sensorpatch) Do not use if package is damaged 8

Technical Information Parameter Alarm unit Extension fiber Sensor patch Size 128 x100 x 35 mm Ø10mm x diffent lenghts 140 x 60 x 1 mm Weight 150 g ca 10-30 g 150 g Usage Temperature +15 to +40 C +15 to +40 C +15 to +40 C Temperature Transportation -20 to +60 C -20 to +60 C -20 to +60 C Temperature Storage -10 to +40 C -10 to +40 C -10 to +40 C Usage humidity Transportation Humidity Storage Humidity Air pressure Shelf life 5 years 5 years See expiry date EMC precautions See EMC Information The Redsense power adapter is approved according to EN60601-1 01/2006 and EN 60601-1-2 10/2006.10 EMC Information Redsense has been tested and approved according to the IEC 60601-1-2 standard for electromagnetic compatibility (EMC). Guidance and manufacturer s declaration electromagnetic emissions Redsense is intended for use in the electromagnetic environment specified below. The customer or the user of Redsense should ensure that it is used in such an environment. Emissions test Compliance Electromagnetic environment - guidance RF-emissions CISPR 11 RF-emissions CISPR 11 Harmonic emissions IEC 61000-3-2 Voltage fluctuations/ flicker emissions IEC 61000-3-3 Group 1 Class B Class A Complies Redsense uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. Redsense is suitable for use in all establish- ments including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. 9

Guidance and manufacturer s declaration electromagnetic immunity Redsense is intended for use in the electromagnetic environment specified below. The customer or the user of Redsense should ensure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment Electrostatic discharge (ESD) IEC 61000-4-2 +/- 6 kv contact +/-8kVair +/- 6 kv contact +/-8kVair Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %. Electrical fast transient / Burst IEC 61000-4-4 +/- 2 kv for power supply lines +/- 1 kv for input/ output lines +/- 2 kv for power supply lines n/a. for input/ output ines Mains power quality should be that of a typical commercial or hospital environment. Surge IEC 61000-4-5 +/- 1 kv differential mode +/- 2 kv common mode +/- 1 kv differential mode n/a. for common mode Mains power quality should be that of a typical commercial or hospital environment. Voltage dips, short interruptions and voltage variations on power supply nput lines IEC 61000-4-11 <5%UT (>95%dipinUT) for 0,5 cycle 40%UT(60%dipinUT) for 5 cycles 70%UT(30%dipinUT) for 25 cycles <5%UT(>95%dipinUT) for 5 sec <5%UT (>95%dipinUT) for 0,5 cycle 40%UT(60%dipinUT) for 5 cycles 70%UT(30%dipinUT) for 25 cycles <5%UT(>95%dipinUT) for 5 sec Mains power quality should be that of a typical commercial or hospital environment. If the user of the [Equipment or System] requires continued operation during power mains interruptions, it is re- commended that the [Equipment or System] be powered from an uninterruptible power supply or battery. Power frequency (50/60 Hz) magnetic field IEC 61000-4-8 3A/m 3A/m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment NOTE: UT is the a.c. mains voltage prior to application of the test level. 10

Guidance and manufacturer s declaration electromagnetic immunity Redsense is intended for use in the electromagnetic environment specified below. The customer or the user of Redsense should ensure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Conducted RF IEC 61000-4-6 Radiated RF IEC 61000-4-3 3 Vrms 1 50 khz to 80 MHz 3 V/m 80MHz to 2,5GHz 3 Vrms 3 V/m Portable and mobile RF communications equip- ment should be used no closer to any part of Red- sense, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance 80 MHz to 800 MHz 800 MHz to 2,5 GHz Where P is the maximum output power rating of the transmitter in watts (W) according to the trans- mitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a should be less than the compliance level in each frequency range. b Interference may occur in the vicinity of equipment marked with the following symbol. NOTE 1 At 80MHz and 800MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflected from structures, objects and people. a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which Redsense is used exceeds the applicable RF compliance level above, Redsense should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating Redsense. b Over the frequency range 150 khz to 80 MHz, field strengths should be less than 10 V/m. 11

Recommended separation distances between portable and mobile RF communications equipment and Redsense Redsense is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of Redsense can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and Redsense as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 khz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2.5 GHz 0.01 0.12 0.12 0.24 0.1 0.38 0.38 0.73 1 1 1.2 1.2 2.3 0 3.8 3.8 7.3 100 12 12 23 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. Note 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. 12