Air Vents for Hot and Chilled Water Systems

Similar documents
VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

The. Steam ONE-PIPE STEAM SYSTEMS

Hoffman Specialty General Catalog

Thermostatic Radiator Valves (Caleffi)

WAL-RICH CORPORATION SINCE 1950

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

Radiator Valve Program

Series 1156F, 1450F ( 1 2") Feed Water Pressure Regulators and Dual Controls for Hot Water Boilers

HYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

HEATING- Heating Accessories RW List Prices Page X - 1. Bronze B&G Circulator Pumps. Iron Body Red Fox B&G Circulator Pump

Spirax-Sarco Industrial Thermostatic Steam Traps

Series 1140 and 1141 Temperature Regulators

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

THERMOSTATIC STEAM TRAPS

HEATING- Heating Accessories RW List Prices Page X - 1. Iron Body Red Fox B&G Circulator Pump. Bronze B&G Circulator Pumps

SECTION SECTION DESIGN REQUIREMENTS

A. This Section includes the following domestic water piping specialties:

STEAM TRAPS

THE THERMOSTATIC STEAM TRAP

Heat Transfer Packages

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

Silhouette. Feedwater Heater. Boiler Feedwater

MASCOT Quick Setup Guide

STEAM ANGLE RADIATOR VALVE HOT WATER ANGLE VALVES DIMENSIONS IN INCHES DIMENSIONS IN INCHES

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

TEMPERATURE CONTROLLERS

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

EXTROL EXPANSION TANKS

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

PureFlow. PureFlow. Fittings system This section doesn t meet California AB1953, Vermont ACT 193 and NSF 61 Annex G Standards.

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat

Blowdown Separator & Aftercoolers

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps.

Liquid Drainers LIQUID DRAINERS

Taco 00 Series Cartridge Circulators

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

WASHER & DRYER REPAIR

RA15/6T & TB Conversion Valve

High Capacity Instantaneous Steam Fired Water Heater

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Threaded. Flanged. Model PSH. Primary Secondary Header A-451

Pump & Trap Combinations

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

Thermostatic Steam Traps

Radiator Trap Radiator Valve

CSD-1 COMMERCIAL BOILER CONTROLS

HEATING & HYDRONICS ZOELLER PUMPS HOUSTON ORLANDO GREENVILLE 800/ / / TOTAL MAINTENANCE SOLUTIONS

Installation, commissioning and servicing instructions

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

YALE Site Specifications AIR VENT SCHEDULE

Hydronic Specialties and Circulator Pumps

Flow Control for Fire Protection

General System Layout Sketch

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

11.4 Component Assembly Diagrams and Parts Lists Case Assembly

SECTION METERS AND GAUGES FOR HVAC PIPING

HVAC No. MFG Part No. Description Size Price

Hydronic Product & Application Catalog

Product Family Overview

Settlement Agreement. Schedule 1: Covered Products

The. Steam TWO-PIPE STEAM & PUMPED RETURN

SECTION METERS AND GAGES FOR PLUMBING PIPING

Packaged Steam Fired Water Heater

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

Wood Boiler Plumbing Schematics

Bringing Energy Down to Earth

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

GWC. User s Information Manual. Gas-Fired Water Boilers. Model

MODEL P. 2 ft. NPSH Cast Iron Bronze Fitted Low NPSH Centrifugal Pumps. BULLETIN 112 Revised 7/09. PH (Horizontal Flange Mounted)

STEAM CONSERVATION GUIDELINES

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

Residential Fire Meter

DIRTCAL - DIRTMAG dirt separator

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

Tuzio Milano Towel Warmer

Transcription:

Air Vents for Hot and Chilled Water Systems Sparco Automatic Vent for Hot Water or Steam Heating The Sparco brand HV190 is a tiny-sized automatic air vent for hot water and steam systems. Installs in baseboards, radiators, convectors and high points in piping systems to remove the trapped air that prevents the free movement of water or steam. The nickel plated valve has a quick venting design and ball check providing positive shut-off. Rated up to 125 psig for water systems, and up to 10 psig for steam heating systems. Maximum temperature for the vent is up to 240º F. 1/8 bottom pipe connection. Height, 1¼ Hygrovent HV190 Auto Air Vent for hot water or steam. 1/8 npt connection. SA1090 Bell & Gossett Air Vents for Hot Water These Bell & Gossett Model 67 and Model 7 float type automatic air vents are designed for Hot Water radiators, baseboards, convectors, radiant panels, small unit heaters and expansion tanks. Install at the high point of the system where air can be expected to collect. Install these vents only in a vertical position with the vent connection pointing up. The Model 67 (same as Hoffman 77) has a 1/8 bottom male pipe connection. Operating pressure up to 50 pounds psi @ 240º F. 3¼ tall x 1½ wide Air Vents for Hot Water Heating & Cooling These Sparco brand air vents bring 2 to 3 times more air venting capacity than other models. The compact design takes up little space, and the advanced construction allows air venting up to 150 pounds psi. Always install in the upright position at highest point in the plumbing. 2 high x 1⅛ wide. Rated to 240. Select ⅛ or ¼ pipe connection. Honeywell-Braukmann Air Vents for Hot Water or Cooling Systems These automatic air vents are high quality, open-close vents for hot water heating systems. Installed at high point in system, both models include safety drain connections and vent caps. Easily serviceable with a built-in shut-off valve: Turn vent body counterclockwise to open; clockwise to close. Choose from two models: Model EA122A is used on water systems up to 230º F. and has a 1/8 male pipe thread connection; operating pressure up to 90 psig. Model EA79 is used on water systems up to 250º F. and has a 3/4 male x 1/2 female dual pipe connection; operating pressure up to 150 psig. 1⅞ Sparco FV147 air vent, 1/8 pipe, 150 psi Sparco FV147A air vent, 1/4 pipe, 150 psi Only 2 high! Fits almost anywhere! 1⅞ SA1050 SA1055 ⅛ pipe connection The Model 7 also has a 1/8 bottom male pipe connection. Operating pressure up to 75 pounds psi @ 240º F. 4⅛ tall x 2¼ wide Model 67(77), 1/8 male pipe conn., 50 psig Model 7, 1/8 male pipe conn., 75 psig 7A 1/4 waste connector with 1/4 tubing to drain water expelled from vents above BI1055 BI1050 BI1056 4¾ EA122A 4¾ EA79 Vents Manual or Automatically Hoffman Model 508 (formerly model 500) vent air from hot water systems manually with a coin, or automatically. Disc-type vent, built-in check valve. 1/8 male pipe connection. Operating press. to 50 psig. Temp. to 240 F. Manual/Auto 508 vent. 1/8 pipe, 50 psi, 240 HK1085 Model EA122A1002. 1/8 male pipe. For hot water to 230º F. Max pressure to 90 psi. Model EA79A1004. 3/4 male x 1/2 female pipe. Hot water to 250º F. Max press, 150 psi HN1234 HN1233 139 Copyright 1987-2013 State Supply

Steam & Hot Water Heating Products & Repair Parts Online: www.statesupply.com Air Vents for Hot and Chilled Water Systems Coin Operated Air Vent These small & inexpensive manually operated hot water air vents are specifically made for radiators. Vents bleed by turning the valve with either a coin or a key (available separately). Operating pressure to 150 psig; Maximum temperature rating to 250º F. 1/8 male pipe connection Manually operated radiator air vent Optional Key for operating above 1/8 bottom connection. Use coin to open & close vent. CG1385 CG1390 Large Air Vents for Main Water Lines Hoffman brand air vents for main water lines are the work horses of the industry. Both models 78 and 79 below are used for hot or cold water, and can discharge moisture entrained in the vented air from the top 1/8 pipe size safety drain connection. The Model 78 has a Heavy-Duty Cast Brass body with a 3/4 male pipe connection. Maximum operating pressure to 150 psig, temperature to 240 F. The Model 79 has a more modest, steel-formed body, and has a dual pipe connection: 3/4 male x 1/2 female You can connect the outside thread into a 3/4 pipe fitting, or connect a 1/2 pipe nipple into the inside 1/2 connection. Operating pressure to 75 psig, temperature to 240 F. Hot Water Air Vents for Convectors, Radiators and Small Mains 78 79 4¼ Model 790 4⅞ Model 791 Hoffman models 790 and 791 air vents have a top connection (1/8 male pipe) allowing for discharging water; or leave cap on to prevent discharge. Model 790 is for convectors, baseboard and wall radiation. It has an 1/8 male pipe bottom connection Maximum operating pressure to 30 psig Temperature to 240 Model 791 is designed for convectors & small mains. 1/4 bottom connection Maximum pressure to 50psi, temp. to 240 F 6½ 6⅝ Model 78, 3/4 pipe, pressure to 150 psig Model 79, 3/4 x 1/2, pressure to 75 psig HK1075 HK1080 Model 790, 1/8 pipe, 30 psig, temp. to 240 F Model 791, 1/4 pipe, 50 psig, temp. to 240 F Model 550 HK1090 HK1095 Convector Air Chamber The Hoffman Model 550 Air Chamber is for use on both steam and water convectors which are not provided with built-in air chambers or air collection fittings. Solid brass construction with a 1/4 NPT bottom connection and 1/8 NPT top connection. 6 cubic inch air volume. Maximum water pressure to 100 psig; maximum steam pressure to 25 psig. 550 Convector Air Chamber HK1087 High Pressure Water Venting Valve Hoffman 792 is a High Pressure Water Venting Valve for releasing air from hot, cold water or glycol mains; hydronic heating and chilling systems; storage and processing tank filters, and centrifugal pumps. Cast iron body with stainless steel interior. Max. operating press. @ 250 psig, discharging 25 cubic feet per minute of air. Max. temp. @ 300º F. 3/4 female pipe bottom connection; 1/2 pipe top connection 7 height 7 792 Vent HK1096 Copyright 1987-2013 State Supply 140 Local Phone: 651.774.5985

Air Vents for Steam Heating Vents for Steam Mains, Condensate Pumps and More! 3/4 male x 1/2 female dual connection Used on low-pressure steam heating systems running at 15 pounds psi and under. These float-type vents have a single non-adjustable port for large air venting capacity. Both models have dual pipe connections: 3/4 male x 1/2 female pipe. The Model 75 has a maximum steam pressure to 15 psig; operates efficiently up to 3 psig. The Model 75-H has a maximum pressure to 15 psig; operates efficiently up to 10 psig. Not for vacuum service. Both models 5¾ high x 2½ width. Model 75, 3/4 x 1/2, set @ 3 psig Model 75-H, 3/4 x 1/2, set @ 10 psig Super Capacity Air Vent for Steam Mains Hoffman 75 & 75H Main Vents HK1060 HK1065 Gorton 1 and 2 Main Vents Used as Main Vents on low-pressure steam heating systems running at 15 pounds psi and under. Especially great for the end of steam mains on one-pipe steam heating systems. Larger than standard discharge capacities make Gorton Air Vents the popular choice for steam heating professionals! Model 1 has dual pipe connections: 3/4 male x 1/2 female pipe. The Model 2 has a 1/2 male pipe connection. Gets rid of twice as much air as the 1 model. Gang air vents together for even more air relieving capacity See Ganged picture below. Application Examples Installation on top of Condensate Tank Hoffman Main Vents are used on the end of steam mains (for onepipe steam heating systems) and on top of condensate receivers on both two-pipe steam systems and modified one-pipe steam systems. Condensate Pump Model 75-H Vent Installation at End of Steam Main Correct Installation Steam Main or Dry Return Main Vent 6 to 10 15 minimum Here the vent is protected from water hammer with a 15 cushion between the vent and the elbow at the end of the steam supply main or dry return pipeline. Incorrect Installation Here the vent is installed in a dangerous position. Water hammer in your steam lines ram into the pipe tee and send hydraulic shock waves up into the vent, shortening its life. Steam Main or Dry Return Main Vent Model 1, Size 3/4 male X 1/2 female dual pipe connection: Install one or more of these (Ganging allows more air venting) at end of the short main, or the main running to the warmer side of the building. Install two or more of these at the end of the long main, or the main running to the colder side of the building. Model 2, 1/2 male pipe connection: This unit gets rid of lots of air! Install one or more at the end of the long main, or the main running to the colder side of the building. 6⅜ tall vent. GX1030 GX1035 Gorton vents Ganged together Ganging air vents at the end of the steam main allows the steam system to heat up fast! 141 Copyright 1987-2013 State Supply

Steam & Hot Water Heating Products & Repair Parts Online: www.statesupply.com Special Vents for Steam Heating Systems Model 4 Quick Valve Thermostatic Main Air Vent The Hoffman Model 4 Quick Valve is a thermostatic air vent for steam heating systems and steam process equipment. Operates on temperature change only and will not close against water. The valve must be installed 6 to 10 above the horizontal return and 18 above the boiler water line. Dual connection shank: 1/2 female (inside) pipe x 3/4 male (outside) pipe. Maximum operating pressure: 25 psig. Height: 2⅝ Model 4, Thermostatic Quick Valve Air Vent HK1015 Thermostatic Main Vent with Float for both 1- and 2- pipe Steam Heating This Hoffman Model 4A Float-Type Thermostatic Vent is found in residential or small one or two-pipe steam heating applications, usually one-pipe systems. Dual connection of 1/2 female NPT x 3/4 male NPT. Single, non-adjustable port. Install 6 to 10 above the horizontal return, and 18 above the water line. Maximum operating pressure to 2 psig. Model 4A, Thermostatic main vent with float Main Vent for One-Pipe Vacuum Steam Heating Systems HK1020 This Hoffman Model 76 Main Steam Vent is a Vacuum Valve used on medium and large size one-pipe vacuum steam heating systems. Float type thermostatic vent with a single, non-adjustable port. 1/2 female x 3/4 male dual thread. Max. Operating Pressure to 3 psig. Overall max. pressure to 15 psig. Air vent height: 6½ Model 3 Steam Air Line & Paul Systems Valve This Hoffman Model 3 Steam Air Line Valve is for Air Line or Paul Systems. Paul Systems were popular in the first half of the 1900 s. Many systems remain in good working order, especially in larger buildings. Thermostatic vent only - No float. 1/8 NPT inlet and 1/4 NPT outlet. The maximum operating pressure goes from 25 psig down to 30 vacuum. The Paul System Valve hooks up to an exhauster, removing system air. Height: 2¼ Model 3, for Paul or Air Line Systems only Steam Unit Heater Air Vent The Hoffman Model 74 Steam Unit Heater Air Valve is made specifically for steam unit heater applications. This floattype thermostatic vent has a single nonadjustable port. Dual connection allows for 1/2 female NPT or 3/4 male NPT piping connection. Make certain to install the Air Valve 6 to 10 above the horizontal return, and 18 above the boiler water line. Maximum operating pressure is 35 psig. Air Vent height: 6⅛ Model 74, air vent for steam unit heater Spirax-Sarco 6A Steam Air Vent HK1010 HK1055 The Spirax-Sarco Model 6A air vent is Premium Quality. It has both a float and thermostatic bellows for use where air, condensate and steam may be present, as in one-pipe steam heating systems. The 6A will discharge air, while preventing the discharge of condensate or steam. An outlet check valve prevents re-entry of air. Cast iron body with stainless steel internals. 3/4 male pipe connection; Maximum operating pressure to 15 psig; 7 height. Model 76, Main Vent for one-pipe vacuum HK1070 Model 6A, for Steam Heating, 3/4 connection SG1010 Copyright 1987-2013 State Supply 142 Local Phone: 651.774.5985

Air Vents for One-Pipe Steam Heating Huh? One-Pipe Steam? If you have a boiler producing steam to heat the building, and the radiators have an air vent installed on the side and there is no steam trap installed on the radiator, you most likely have a one-pipe steam heating system: Only one pipe supplies the steam and allows for condensate (steam turned into water) to leave the radiator and head back for the boiler where the condensate, once again, is heated into steam. These systems need good air vents! Simple One-Pipe Steam System Radiator Supply Valve One pipe supplies steam Same pipe returns condensate Air Vent No steam trap or return piping here! Main Vent important! One-pipe steam systems don t have radiator steam traps like this... Here s a guy working on a steam trap which you don t have on your radiators if you have a one-pipe steam heating system. STEAM CONDENSATE Gorton Air Vents Great for One-Pipe Steam These Gorton air vents have received critical acclaim as one of the best one-pipe steam heating vents on the market. By installing a correctly-sized Gorton air vent on each radiator, and a main vent near the end of your condensate return line, you will balance your one-pipe steam heating system. Well, at least in theory. Air needs to be removed from your steam heating system. Air trapped in your system will prevent steam from getting where it needs to go And if the steam heat can t get there, you re one cold camper. Model 2 Models 4, 5, 6, C and D are used on radiators. Select from different air venting capacities Big radiators need more venting capacity than small radiators. Model 1 Models 1 and 2 are high capacity air vents for the end of steam mains, unit heaters, condensate receiver tanks and more! The Model 1 is found in both homes and smaller commercial buildings. The Model 2 is generally used in larger commercial buildings where large steam heating systems are found. Model 4, Standard Vent for the room where thermostat installed, 1/8 angle pipe. Height: 2⅜ GX1005 Model 5, Vent for standard radiators that are normally easy to heat, 1/8 angle pipe. Height: 2⅜ EQUAL TO Four standard type air valves Model 6, Vent for larger radiators and those harder to heat, ⅛ angle pipe. Height: 2⅜ EQUAL TO Eight standard type air valves Model C, Vent for even larger and harder to heat radiators, 1/8 angle pipe. Height: 2⅜ EQUAL TO Fifteen standard type air valves Model D, Vent for your largest and/or hardest to heat radiators. 1/8 angle pipe. Height: 2⅜ EQUAL TO Twenty-seven standard type air valves Model 1965, 3/8 Main Vent: Use one for short main, or main running to warm side of building; use two or three vents at end of the long main or main running to cold side of building. 3/8 straight male pipe connection. Height: 3⅜ Model 1, 3/4 Main Vent: Same as above but with 3/4 straight pipe connection Model 2, Main Vent: Install one or more of these air eliminators at the end of the long main, or the main running to the cold side of the building. 1/2 straight connection. Height: 6⅜ GX1010 GX1015 GX1020 GX1025 GX1040 GX1030 GX1035 143 Copyright 1987-2013 State Supply

Steam & Hot Water Heating Products & Repair Parts Online: www.statesupply.com Air Vents for One-Pipe Steam Heating Systems Port lets you control the heat output from the radiator! Model 1A Hoffman Specialty Radiator Vents for One-Pipe Steam Model 1A vent, 1/8 HK1005 The Hoffman 1A is a great radiator air vent for one-pipe steam heating systems. The adjustable port on top of the vents lets you be in control of air discharge from the radiator. Got a hard-to-heat radiator? Crank that baby up to level 6 and watch that radiator heat up! Got a radiator that s too hot? Crank that baby down to level 1 and allow more air to stay in the radiator reducing heat output. Maximum operating pressure: 1½ psi steam. Pipe connection: ⅛ Radiator Supply Valve One-Pipe Radiator Example Radiator Air Vent Air Vents on one-pipe steam systems are critical to efficient steam heating operation. Air vents may last from 2 to 10 years. Longevity is related to the dirt and debris that may be clogging the vents. To extend the life of the air vent: In the summer, when the boiler is off, remove the air vents and place them in boiling vinegar. The acid in vinegar may remove the build-up of junk stuck in your vents. Call us if that doesn t work We can sell you some new ones. The Hoffman 70A is a standard radiator vent for one-pipe steam heating systems. Non-adjustable port. Not as popular as the 1A (above) or the model 40, below. This float-type vent is rated to work at pressures up to 11 pounds psi steam. One-pipe steam systems should generally operate with less than 2 pounds psi steam pressure. Pipe connection: ⅛ angle pattern Non- Port Model 70A Model 70A vent, 1/8 HK1050 The Hoffman 40 is a standard radiator air vent for onepipe steam heating systems. Non -adjustable port. Less popular than the 1A or 70A models. This float-type vent is rated to work at pressures up to 6 pounds psi steam. One-pipe steam systems should generally operate with less than 2 pounds psi steam pressure. Pipe connection: ⅛ angle pattern Non- Port Model 40 Model 40 vent, 1/8 HK1025 Air Vent Operator The 1PS thermostatic air valve assembly replaces the old air vent installed on the side of your radiator Valve Body Simply remove the old air vent and install the 1PS thermostatic air valve assembly One-Pipe Venting and Automatic Temperature Control Get the temperature control you ve always wanted in every room! Don t you just hate it when the den is nice and toasty, the kitchen is as hot as a pistol, and the bedroom is as cold as Siberia? Well, forget about it Those days are history! The Macon OPSK non-electric thermostatic valve assembly includes the valve (replaces the old air vent on the side of your radiators), an air vent (goes on top of the valve) and the non-electric thermostatic operator (that works like a thermostat!). The temperature controlling operator attaches to the side of the valve. Simply turn the dial for the room temperature you want! For one-pipe steam heating only. all 3 pieces for a complete assembly OPSK One-pipe steam kit: Includes 1/8 valve (installs in place of old air vent), new air vent & vacuum breaker (attaches to valve), and non-electric thermostatic operator (attaches to side of valve). Macon brand. MV1200 The operator works just like a thermostat! Copyright 1987-2013 State Supply 144 Local Phone: 651.774.5985

Air Vents for One-Pipe Steam Heating Systems One-Pipe Steam Air Vents for Steam Convectors Port lets you control the heat output from the radiator! Model 1B Operating Pressure up to 1½ psi steam The Hoffman 1B is a great convector air vent for one-pipe steam heating systems. The Port on top of the vents lets you be in control of the air discharge. Got a hard-to-heat radiator? Crank that baby up to level 6 and watch that radiator heat up! Got a radiator that s too hot? Crank that baby down to level 1 and allow more air to stay in the radiator reducing heat output. Maximum operating pressure: 1½ pounds psi steam Pipe connection: ⅛ straight connection. Max. temp: 240º F. Model 1B air vent, 1/8 straight pipe connection HK1007 The Hoffman Models 41, 43 and 45 are all single, non-adjustable port air vents for steam heating pressures up to 6 pounds psi. The internal telescopic, angle cut siphon tube within the vent assures drainage. Max. temp: 240º Model 41 pipe connection: 1/8 straight Model 43 pipe connection: 1/4 straight Model 45 pipe connection: Dual threads 1/2 inside (female) x 3/4 outside (male), straight pipe connection. Port is not adjustable Models 41, 43 & 45 Operating Pressure up to 6 psi steam Model 41 air vent, 1/8 straight pipe connection HK1030 Model 43 air vent, 1/4 straight pipe connection HK1035 Model 45 air vent, dual straight pipe connection: 1/2 female x 3/4 male HK1040 Model 71C Shown here. Models 71-A, -B, -C Operating Pressure up to 11 psi steam The Hoffman Models 71A, 71B and 71C are all single, nonadjustable port air vents for steam heating pressures up to 11 pounds psi. Max. temp: 240º F. The internal telescopic, angle cut siphon tube within the vent assures drainage. Model 71-A pipe connection: 1/8 straight Model 71-B pipe connection: 1/4 straight Model 71-C pipe connection: Dual threads 1/2 inside (female) x 3/4 outside (male), straight pipe connection. Maximum operating pressure: All models, 11 pounds psi steam 71-C air vent, dual straight pipe connection: 1/2 female (inside) x 3/4 male (outside) 71-A air vent, 1/8 straight pipe connection HK1052 71-B air vent, 1/4 straight pipe connection HK1052B HK1052C Automatic Venting for One-Pipe Steam Convectors and Radiators The Sparco brand HV190 is a tiny-sized automatic air vent for hot water and steam systems. Installs in baseboards, radiators, convectors and high points in piping systems to remove the trapped air. Rated up to 125 psig for water systems, & to 10 psig for steam heating systems. Maximum temperature for the vent is up to 240º F. Height, 1¼ 1/8 bottom pipe connection. Hygrovent HV190 Auto Air Vent for hot water or steam. 1/8 npt connection. SA1090 The BIG Catalog - FREE with any order! Jam-packed with over 600-pages of the product, repair parts & replacement components needed to keep your plumbing and heating systems purring like a kitten. Comprehensive schematic drawings, repair part tables and ordering guides allow you to easily determine the product or repair parts you need! Ask for Catalog CT1002 when you place your order. 145 Copyright 1987-2013 State Supply