INSTALLATION AND OPERATING MANUAL

Similar documents
INSTALLATION AND OPERATING MANUAL

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

Flopurge TS. Operation Manual

4 & 8-POINT ANNUNCIATORS Instruction Manual

Flostop TS D7E and A8E. Operation Manual

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Software Version 2.01 LEVEL MONITOR MODEL 220

Beacon 800 Gas Monitor Operator s Manual

Door Release Power Supply

WIO200 Water In Oil measuring instrument

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

FLOW CONTROLLER TYPE S/601

Remote alarm indicator and test combination MK2430

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Operating Manual MS220DA

RFID Card Access Control Unit. Operating Instructions

DIGITAL ALARM UNIT Model ALU-AP

Operating Manual RCM420

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

RE-PR3-E-27 3-Phase Panel Mount 27kW

ASSURIX Intrinsically Safe Photoelectronic Sensors

CSP-204 CSP-208 CSP-104 CSP-108

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

RS Pro Infrared Temperature Sensor

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Carbon Monoxide Transmitter

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Snifter ATEX22 VERSION. User Manual. Distributor

Operations Manual. Motion Detector Module Model ZS10

1.7. Insulation fault evaluators EDS460/490 EDS461/491

S/601 Controller Installation Manual

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

GAS SUPRESSION CONTROL PANEL:

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

User Guide

UDC100 Universal Digital Controller Specifications

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Universal fault annunciator for panel mounting

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Single phase solid state contactors ENG. User Manual DATA MANAGEMENT CONTROLS PROCESS AUTOMATION

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

Insulation fault evaluator EDS460-DG

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Vibracon LVL-A* Level limit switch for liquids, compact design

1.7. Insulation fault evaluators EDS460/490 EDS461/491

DNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual

D-Tect 2 GJD300 Quad PIR Movement Detector

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

M15051) INSTRUCTION MANUAL

BSR Addressable Fire Detection control panel. Installation operation manual

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Installation, Operating and Maintenance Manual

PolyGard 2-channel Gas Controller MGC-03

Small in size, with grand features USER GUIDE Elle-même petite, mais avec caractéristique grand

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

eed quality electronic design USER s MANUAL

Excellence in Level Measurement

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

FCR 05, FCR 07. Power factor correction controller. User and service manual

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

Operating Manual MS220KA and MSR220KA

Beacon 410A Gas Monitor Operator s Manual

DB5 Intrinsically Safe Sounder Type DB-5

UDC 700 Universal Digital Controllers and Indicator Specifications

Installation Instructions CS3 Three Phase Solid State Relay

Conductive Leakage detectors of the Leckstar range

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

1X-F Series Installation Manual

PumpSaver ISS-105 IS Super Cell Installation Guide

Beacon 110 Gas Monitor Operator s Manual

NT DUAL CHANNEL DISPLAY. User Guide

MWS3 Ceiling Mount Microwave Occupancy Detector

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

Operation and use. Functions and characteristics

Gas Safety Products. Installation, operating and maintenance 11/26/2015. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

active infrared 875 nm < 250 mw/m² motion & presence 157 in x 157 in (emitting spots**) 2 in/s to activate detection 250 ms 15-45

SENTINEL A - Fault Passage Indicator

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

XLH210: controller for gas leak detectors

AO Annunciator Module

Analog Room Pressure Monitor RPC Series

D-TECT Dual Tech. GJD360 Triple Technology External Detector

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

WHA 3000P Hot Air Station

Technical Manual. Level Alarm Unit CARLA & WIDS

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Macurco DVP-120 Detection and Ventilation Control Panel

Instructions for the fan motor control system with integrated wiring terminals SILVER C

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

Soft Starter Centrifugal Pump Soft Starter Series

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Transcription:

INSTALLATION AND OPERATING MANUAL Spectron Gas Control Systems GmbH Fritz-Klatte-Str. 8 65933 Frankfurt Germany Tel.: +49 69 38016-0 Fax: +49 69 38016-200 Email: info@spectron.de www.spectron.de 1 GES_K12_0915.docx

Contents 1. Overview... 3 2. Set-UP... 3 2.1. Connecting Power Supply... 3 2.2. Connecting Inputs... 3 2.3. Connecting Relay Output... 3 2.4. First Power-UP... 3 3. Installation of the device... 4 3.1. Diagram Connections... 4 4. Configuration of device... 6 5. Working... 9 6. Technical Characteristics... 10 7. Reference standards... 10 8. Declaration of conformity... 10 2 GES_K12_0915.docx

1. Overview FLOALARM is especially conceived to monitor alarm conditions in compressed gas storages and supply pipelines. Three types are available: K4 with four inputs, K8 with eight inputs and K12 with twelve inputs. All alarm inputs are compatible with popular switch sensors and inductive proximity sensors type NAMUR. The alarm status is testified by the visual and acoustic signals. Visual signals include 4 (8 or 12) red LEDs associated to each alarm input. Two green LEDs: one green LED (Power) to indicate that the device is powered and one green LED (OK) to indicate that there are no alarm conditions. Blinking status of red LED testifies that the corresponding alarm input is active and this alarm condition is still unacknowledged. Fixed lighted status of red LED testifies that the corresponding alarm input is active and this alarm condition was already acknowledged. Acoustic alarm signal indicates one or more unacknowledged alarm conditions. All current unacknowledged alarm conditions become acknowledged and the acoustic signal is switched off by pushing CANCEL HOOTER button. The TEST button starts the standard test of all signaling devices and programming check cycle. A relay output is available to drive an additional hooter or an external alarm indicator. All programming functions can be set and modified by two buttons on the back of the frontal part of the alarm device. 2. Set-UP WARNING: For safety reasons, the qualified operators must only carry out the installation in accordance with this instruction manual. The manufacturer rejects any responsibility for accidents or damages due to negligence of these instructions. 2.1. Connecting Power Supply Use 1.5 mm 2 section cables. Put a 2 A bipolar security interrupter on the power supply line. 2.2. Connecting Inputs Connect each sensor using bipolar 0.25-0.5 mm 2 section cable. Shielded cables with shields connected to earth are suggested, but not mandatory. 2.3. Connecting Relay Output Use 0.5 to 1.5 mm 2 section cables, in function of switching current and line length. 2.4. First Power-UP At the first power-up, all the inputs are set normally closed (NC), the green LEDs of OK and POWER must be on and all the red LEDs are off; the ringtone is not active. 3 GES_K12_0915.docx

To program each inputs, open the front part of the box and enter in the configuration mode (please, read the following instructions). 3. Installation of the device 3.1. Diagram Connections FLOALARM K12 Connections Legend Clamp Description Clamp Description 1 17 Input Kanal / Line 1 2 18 Input Kanal / Line 9 3 19 Input Kanal / Line 2 4 20 Input Kanal / Line 10 5 21 Input Kanal / Line 3 6 22 Input Kanal / Line 11 7 23 Input Kanal / Line 4 8 24 Input Kanal / Line 12 9 10 Input Kanal / Line 5 11 27 Relay N.O. Input Kanal / Line 6 12 28 Relay N.C. 13 29 Common Relay Input Kanal / Line 7 14 30 15 Power Supply Input Kanal / Line 8 16 32 Attention: In case of FUSE substitution, use one of 500mA. For the connection between the device and sensors, use wires with section 0.25 0.50 mm 2, for the power supply wires with section 1.5 mm 2. 4 GES_K12_0915.docx

FLOALARM K8 Connections Legend Clamp Description Clamp Description 1 27 Relay N.O. Input Kanal / Line 1 2 28 Relay N.C. 3 29 Common Relay Input Kanal / Line 2 4 30 5 Power Supply Input Kanal / Line 3 6 32 7 8 Input Kanal / Line 4 9 10 Input Kanal / Line 5 11 12 Input Kanal / Line 6 13 14 Input Kanal / Line 7 15 16 Input Kanal / Line 8 Attention: In case of FUSE substitution, use one of 500mA. For the connection between the device and sensors, use wires with section 0.25 0.50 mm 2, for the power supply wires with section 1.5 mm 2. 5 GES_K12_0915.docx

FLOALARM K4 Connections Legend Clamp Description 1 Input Kanal / Line 1 2 3 Input Kanal / Line 2 4 5 Input Kanal / Line 3 6 7 Input Kanal / Line 4 8 27 Relay N.O. 28 Relay N.C. 29 Common Relay 30 Power Supply 32 Attention: In case of FUSE substitution, use one of 500mA. For the connection between the device and sensors, use wires with section 0.25 0.50 mm 2, for the power supply wires with section 1.5 mm 2. 6 GES_K12_0915.docx

4. Configuration of device To configure the device, it is necessary to enter in the configuration mode. CONFIGURATION MODE To enter in the configuration mode, follow these steps: - Open the box removing the screws under the cover strips. - Push for 5 seconds one of the yellow push button behind the front panel. The green LED of POWER will start to blink. SELECTION OF THE INPUT To select the input that must be configured, follow these steps: - Push the TEST button. Scroll the inputs; the input selected is indicated by the red LED. - Push the HUPE AUS/CANCEL HOOTER button. The red LED start to blink. CONFIGURATION OF THE INPUT SELECTED To configure the parameters of the inputs selected, check the LEDs on the bottom PCB on the device (their locations are indicated in the connection diagram of the previous page). - Push the TEST button to scroll the LEDs - Push the HUPE AUS/CANCEL HOOTER to choose the status of the LED (blinking or fixed) Meaning of the LED status LED Parameter Blinking Fixed LED 1 LED behavior Blinking Fixed LED 2 Contact configuration Normally Open Normally Closed LED 3 Ringtone configuration Active Disabled LED 4 Relay configuration Active Disabled LED 5 Exit LED - Scroll till the LED 5 - Push HOPE AUS/CANCEL HOOTER to exit from the configuration of the input. The RED led correspondent return fixed. 7 GES_K12_0915.docx

RINGTONE SOUND LEVEL To choose the sound level of the ringtone, move the SWITCH on the bottom PCB (in the diagram of previous page, it is indicated with SWITCH). LEFT position: HIGH sound level. RIGHT position: LOW sound level. DEFAULT PARAMETERS To load the default parameters, follow these steps: - Push the two yellow button behind the front panel. All LEDs start to blink. - Push the TEST button. Start a consecutive activation of all LEDs. Default parameters (same for each inputs): - LED behavior: Blinking. - Contact configuration: Normally Closed. - Ringtone configuration: Active. - Relay configuration: Active. EXIT FROM THE CONFIGURATION MODE To exit from the configuration mode, follow these steps: - Scroll the input until arrive to the POWER LED. - Push HUPE AUS/CANCEL HOOTER - The 5 LEDs on the bottom PCB will blink in sequence and all LEDs on the front panel lights. - After that, the configuration is set and the device is ready to work. 8 GES_K12_0915.docx

5. Working Alarm management The standard alarm sequence includes three steps: Case 1: acknowledgement before the end of the alarm event 1. Start of alarm event: input switches from normal to alarm condition. Buzzer switches on and the corresponding alarm LED becomes blinking or fixed (depending to the setting), indicating an unacknowledged alarm status. 2. Alarm acknowledgements: user pushes CANCEL HOOTER button. Buzzer stops and alarm LED switches from blinking to fixed (if in the setting it was configured to blink), indicating an acknowledged alarm status. 3. End of alarm event: input switches from alarm to normal condition. Alarm LED switches from active to off. Case 2: acknowledgement after the end of the alarm event 1. Start of alarm event: input switches from normal to alarm condition. Buzzer switches on and the corresponding alarm LED becomes blinking or fixed (depending to the setting), indicating an unacknowledged alarm status. 2. End of alarm event: input switches from alarm to normal condition. Same signals continue, system remains in previous alarm status. 3. Alarm acknowledgement: user pushes CANCEL HOOTER button. Buzzer stops and alarm LED turns off. The alarm management is with memory ; namely, if the end of the alarm event occurs before the acknowledgement, the equipment remains in unacknowledged alarm status, until the acknowledgement. Acknowledgement operation is effective over all the current alarms. 9 GES_K12_0915.docx

6. Technical Characteristics INPUTS specifications INPUTS compatibility RELAY OUTPUT: SUPPLY VOLTAGE: V(max) = 15 Vdc; I(max) = 20 ma Standard mechanical switch sensors Solid state PNP / NPN switch sensors. DC only Inductive proximity sensors type NAMUR V(max) = 24 Vac Imax = 1 A NO and NC contact available 110-230 V AC /50 60 Hz, P (max) = 3 W Fuse: 230V / 0,1 A and 110 V / 0,25 A HOUSING: IP65 plastic box for wall mounting K4/K8/K12 type: 200 x 120 x (h) 60 mm Namur specifications SUPPLY VOLTAGE 5 Vdc < +Vs < 25 Vdc target present IL<1mA LOAD CURRENT target absent 3mA < IL < 15 ma 7. Reference standards The device is in compliance with CE standards directive: EN 50081-1: Electromagnetic compatibility - Generic emission regulation. EN 50082-1: Electromagnetic compatibility Generic immunity regulation. EN 61000-3-2: Electromagnetic compatibility (EMC) Part 3: Limits. EN 61000-4-3: Electromagnetic compatibility (EMC); Parts 4-3: Technical and measurement test Immunity test to radiofrequency and irradiated electromagnetic fields. EN 61000-4-4: Fast transient immunity EN 61000-4-2: Electrostatic discharge immunity 10 GES_K12_0915.docx

8. Declaration of conformity 11 GES_K12_0915.docx