POINT ROLLOVER LIGHTS PRL LED HELIPORT INSET LIGHT

Similar documents
POINT ROLLOVER LIGHTS PRL LED HELIDECK SEMIFLUSH LIGHT

POINT HELIDECK LIGHTS PRL-LSM LED LOW SURFACE MOUNT LIGHT

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

POINT FLASHING BEACON PFB EX LED HAZARDOUS AREA CLASS I, DIVISION 2

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

POINT STATUS LIGHTS PSL LED HELIDECK STATUS LIGHT SYSTEM SAFE AREA & CLASS I, DIVISION 2 (ZONE 2)

Heliport & Helideck Lighting System. For Non Hazardous and Hazardous Locations. Option: Marine Treatment for superior corrosion protection

SUPPLEMENTAL INSTRUCTION SHEET POL S2 POINT OBSTRUCTION LIGHT SINGLE WITH ALARM

Rugged LED shelter lighting

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

Applications. Standard Materials

Vigilant LED Based Obstruction Lights

Product Specifications MaxLumen MRI LED Diffused Lighting

Obelux MI-2KR-A Page 1/5 ICAO Medium Intensity Type B and C, FAA L-864 and L-885, cd flashing / fixed red obstacle light

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

IVR15-RPS O.D. Solid State Illuminated Rail Remote Power Supply

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

1. PURPOSE. This advisory circular (AC) contains the Federal Aviation Administration (FAA) specification for obstruction lighting equipment.

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

Vigilant LED Based Obstruction Lights

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

Moon Visions Lighting

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

LMV Series W Low Profile - Medium Base

150W Explosion Proof LED Flood Light - Surface Mount Lumens - C1D V AC

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

LIGHTING TEF 9980 STATUS LIGHT, MAIN LIGHT & REPEATER LIGHT ZONE 1, ZONE 2 & SAFE AREA USER MANUAL

Product Specifications MaxLumen MRI LED Diffused Lighting

Airfield lighting. Product Brochure

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

Product Specifications MaxLumen MRI LED Diffused Lighting

Vigilant LED Based Obstruction Lights

Date: 3/11/2019 Initiated By: AAS-100

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

REFRACTOPACK. Corrosion resistant construction allows this luminaire to be installed in corrosive and marine outdoor applications.

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

Choice of factory set distributions. Thermally set white polyester powder paint. Optional wet location listing

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

Obstruction Lighting Guide

High-Intensity cd Aviation Light

DuroSite LED High Bay - UL for Indoor and Outdoor Industrial Applications. Patent Pending

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

DuroSite Series LED High Bay - UL for Indoor and Outdoor Industrial Applications. Patent Pending

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

SOLID STATE ILLUMINATED RAIL

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Vaya Linear LP, White & Mono

300W EXP LED Light - 35,000 Lm - 3' Cart Mount - Quick Change Mount - C1D1-100' 16/3 SOOW- EXP Plug

SECTION SOLAR PHOTOVOLTAIC (PV) POWER GENERATION SYSTEM

Installation Instruction Manual

SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS)

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

Altman Lighting Spectra Cyc UV 50 Specification

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

WLS-T25 Solar Powered Low Intensity Duty & Stand-by Aviation Obstruction Light

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

LIGHTING COMMERCIAL AQUATICS

33 Watt Low Voltage LED Fixture for Hazardous Location Lighting - Low Profile Linear Fixture - C1D2

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

Infrared LED Light - 3 watts - stud mount v - 750nm, 850nm or 940nm

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps

UTILITY LIGHT INTRODUCTION

American Railway Engineering and Maintenance of Way Association Letter Ballot. Draft

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

HL-2449_flg:8 pager 6/17/10 11:19 AM Page 1 Tear Drop LED Series

COMPACT SIZE INTRODUCTION & LOGIC

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

480W High Intensity LED Light - 60,000 Lumens V AC - High Mast Lighting - Pole Top Mount

OWNER S MANUAL Model A702 / A702-5 Aviation Light with Switch

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

General Specifications for Lighted Crosswalk Warning Equipment and Miscellaneous Materials, Rev 4

Dialight Obstruction LED Solutions

ecolor Graze Powercore Linear LED surface light for wall washing and grazing

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

PRODUCT CATALOG HUGHEYANDPHILLIPS.COM

Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'

Evolve LED Garage Light

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

Transcription:

Compliances: ETL Listed to UL 98 ETL Listed to UL 98A Marine Vessels ETL Listed to CSA C22.2 No..-4 Canada FAA AC /39-2B Heliport Design Guide ICAO Annex 14, Volume II UK CAA CAP 437, Chapter 4, paragraph 3.1 US Army Aviation Lighting Manual TM -811-, Figure -3 Transport Canada TP14371, AGA 7.17 American Bureau of Shipping (ABS) Type Approved Product The Point Rollover Light is used for heliport lighting applications where an inset light is required providing better visibility and circling guidance than comparable incandescent. The may be serviced without removing the fixture from its mounting base. The lens and optical assembly are sealed mechanically without the use of chemical sealants. The thick soda lime glass dome lens will withstand high rollover loads. Silicone-filled connectors are included. See MOUNTINGS details H9 & H11 PLB and PLS bases are standard with 2 x 1-inch NPT at entries & 18-deg Point Type Voltage Array Color Mounting & Options PRL-972 1: 12v P: note 1 G: Green VB: Variable Brightness 2: 22v H: note 2 Y: Yellow PLB: Base & Gasket 3: 12v DC F: note 3 C: White PLS: Shallow Base & Gasket 4: 24v DC N: NVG * R: Red TRH: Tamper Resistant Hardware B: Blue DH: Drain Hole in Base IR: Infrared* GR: Ground Lug in Base MT: Marine Treatment NC: NVG compatibility** Note 1: Array P is good for general use fixed brightness (no dimming) at approximately PHC brightness step 2 Note 2: Array H exceeds ICAO Annex 14, Vol II & is suggested to use with variable brightness PHC controller. Note 3: Array F is for UK CAA CAP 437 compliance. * For NVG tactical use only: PRL-972-1N-IR-MT-PLB ** For use with visible (non-ir) arrays P or H; adds IR LEDs. Option NC2 is IR or visible mode switchable. Option MT is recommended for all marine, high salt content air and other corrosive environments. The fixture shall be treated for marine conditions by cleaning per US MIL method III of TT-C-49, chromate priming per US MIL-C-41, epoxy powder base coat and glossy polyester powdercoat finish coat in color RAL 63 (FED-STD-9 color #1497) green. Oven cured per US MIL-PRF-24712A. PRL-972-1H-G-PLS-VB-GR WITH PLS RECESSED BASE, GASKET & GROUND LUG HL-1.1. June, 212

4 PHOTOMETRIC CHART: GREEN ARRAY H LED Array H in Green: 2 cd at 12-deg V -18 - -12-9 -6-6 9 12 18 ICAO Annex 14 Volume II, Chapter : Minimum cd at & 2 deg V 4 PHOTOMETRIC CHART: YELLOW ARRAY H LED Array H in Yellow: 6 cd at -deg V 2 The lights are dimmable by installing: POINT LIGHTING CORP PHC-62 Heliport Controller -18 - -12-9 -6-6 9 12 18 4 PHOTOMETRIC CHART: GREEN ARRAY P LED Array P in Green: cd at 12-deg V 2 7. -18 - -12-9 -6-6 9 12 18 3.

SPECIFICATIONS The (specify: color), (specify: voltage) /6 Hz aviation inset light shall operate properly within an input voltage supply range of +/- 2% for 12V units (93V to 144V) and for 22V units (176V to V). Within the preceding ranges, the output to the LED board shall be a controlled, stabilized constant current. The heliport lights shall be listed and labeled Suitable for Use in Wet Locations to UL98A Marine Vessels, UL98 2nd Edition Luminaries; CSA C22.2 No..-4, 2nd Edition; UL 11th Edition Standard for Enclosures for Electrical Equipment and CSA C22.2 No. 94-M91 Special Purpose Enclosures. Sealed to IP66 ingress protection. The inset light shall be cast aluminum and assembled with all stainless steel hardware. All exterior stainless steel hardware shall be recessed so as not to protrude above the fixture surface. The highest point of the lens shall not exceed.7-inch (19-mm) above finished grade. The lens and lamp housing (optical assembly) shall be sealed mechanically without the use of chemical sealants. The fixture shall be capable of being serviced without removing the fixture ring from its mounting base. Flexible epoxy sealant may be used to moisture seal the fixture and pavement interface and will not have to be disturbed for service. The inset light shall be prewired with three conductors (line, neutral, ground). Entry to the light housing shall be by means of a watertight cable compression fitting. The manufacturer shall include silicone-filled wire connectors for installer use for watertight connections. The LED lighting circuits shall be remotely dimmable by means of a heliport controller designed and produced by the lighting manufacturer. Option -VB: For use with the PHC-62 or PHC-63 adjustable brightness heliport controller, this option is required. The PHC Heliport Lighting Controller shall incorporate an IEC approved surge suppressor and current limiting circuit breakers on each load output. The photometric performance shall exceed candelas over a range defined by ICAO Annex 14, Volume II, Figure - 9. The LED light shall have a tested and verified power consumption not to exceed (see chart next page). The light casting shall be powdercoat painted aviation yellow for corrosion resistance certified by the manufacturer to comply with the US Military Standard Salt Fog Test conducted per MIL-STD-8E, Method 9.3, Procedure I. All hardware shall be stainless steel. The colored outer glass lens shall be smooth and rounded to reduce the adhesion of dirt, ice and snow. The glass color shall be matched to the LED wavelength to maximize light transmissivity. The unit shall be warranted to withstand an ambient temperature range of +1 deg F (+ deg C) to -67 deg F (- deg C). Option -MT: The fixture shall be treated for marine conditions by cleaning per US MIL method III of TT-C-49, chromate priming per US MIL-C-41, epoxy powder base coat and glossy polyester powdercoat finish coat in color RAL 63 (FED-STD-9 color #1497) dark green. Oven cured per US MIL-PRF-24712A. The color emitting LEDs shall meet the chromaticity requirements of US MIL-C-. The high output LED s shall not exceed six (6) in number and shall be the latest technology providing uniform light output over the range three (3) to twenty (2) degrees vertical and in 36 degrees horizontal. The LED average life shall exceed, hours. The LEDs shall be soldered in a factory set position to insure consistent light output. Wire mounted raised LEDs that can be bent out of position shall be unacceptable and cause for rejection. The LED board shall be treated with a protective dielectric conformal coating for protection from moisture and corrosion. The power supply board shall include short circuit and open circuit protection and the unit shall be protected from line surges by metal oxide varistors (MOVs). There shall be a clear design element for the dissipation of LED heat to insure the LEDs do not fail prematurely. Note: It is strongly recommended that the circuit also be directly protected by a Point Lighting Corporation surge suppression device such as a PHC, SPU or PRC unit. The cast aluminum mounting base shall be PLB-4 (option -PLB) with two (2) 1-inch NPT hubs located at & 18 degrees near the bottom of the -inch deep base. The PRL shall be secured by three (3) socket head stainless steel screws supplied by the manufacturer. There shall be a disposable plywood cover to set the base at the proper depth to recess the light. PL71-X spacer rings may be required to adjust the height of the light to match grade. The LED heliport inset light shall be POINTSPEC Series PRL-972 manufactured by Point Lighting Corporation. LED signals can be expected to provide an additional margin of conspicuity over incandescent light sources with the same luminous intensity. --- Transport Canada 23 Study TP1443E

POWER CONSUMPTION POINT ROLLOVER LIGHTS Code Type Voltage Frequency Watts* ma VA* -1P Array P 12 AC /6 Hz.7 8 7. -2P Array P 22 AC /6 Hz.6 33 7.2-3P Array P 12 DC ---.6 47 --- -4P Array P 24 DC ---. 2 --- -1H Array H 12 AC /6 Hz 7.7 8 9.6-2H Array H 22 AC /6 Hz 7.6 43 9. -3H Array H 12 DC --- 8.4 7 --- -4H Array H 24 DC --- 8.3 34 --- -1F Array F 12 AC /6 Hz 9.7 91.8-2F Array F 22 AC /6 Hz 9.7 49.8-3F Array F 12 DC --- 13. 96 13. -4F Array F 24 DC --- 13. 4 13. *Power consumption for AC units includes the effect of the unit s power factor which accounts for the difference between watts and volt-amperes. Measurements were made at the nominal AC voltages. The operating range for 12v units is 93-144v. The operating range for 22v units is 176 - v. RECOMMENDED TOOLS Point Lighting Corporation recommends return for factory repair and refurbishment of LED PRL lights. In the event of field service, the PL839 preset torque wrench kit use with the instruction manual is recommended to assure proper resealing of the fixture. PL86 Tool, T-handle Wrench For the three socket head screws fixing the PRL fixture to the PLB mounting base. PL839 Tool, Preset Torque Wrench Kit For the socket head screws fixing the PRL lens clamp ring and for fixing the power supply subassembly. Consult the factory and the manual before attempting field repair.

Night Vision Goggles (NVG) Point Lighting Corporation offers several options for combining infrared and color LEDs to render our lights visible with and without NVG. Please contact us with your specific application requirements. Instruction Sheet: IS972 LED Life (hours):, Projection:.7 (18) Base Diameter: 8. (23) PLB Depth:. (4) PLS Depth: 4. (2) Weight: 12 lbs. kg Volume:.37 ft3.13 m3 Replacement Parts PL23-G Lens, Green PL23-Y Lens, Yellow PL6-H-6G LED Array H, Green PL6-F-8G LED Array F, Green PL6-P-4G LED Array P, Green PL6-P-4Y LED Array P, Yellow PL Gasket, Lens Upper PL31 Gasket, Lens Lower PL32 Gasket, Lamp Housing PL49-4 Gasket, Base PL24-118 Screw, Socket Head PL71-X Spacer Ring x/8-inch PL6 Tool, option TRH PL839 Tool, preset torque wrench kit PL86 Tool, T-handle wrench P O I N T L I G H T I N G C O R P O R A T I O N Mail: P.O. Box 686, Simsbury, CT 67 Plant: West Dudley Town Rd, Bloomfield, CT Tel 1 86.243.6 USA Fax 1 86.243.66 email: Info@PointLighting.com website: www.pointlighting.com