SIZES AVAILABLE INDUSTRIAL: ARCHITECTUAL STEP NOSINGS

Similar documents
SAFETY TECH. RRL Pendulum Test >36 (wet test) EN Class DS Bacterial resistance

EXIT Sign model number C with optional directional chevrons.

NON ELECTRICAL LOW LEVEL GUIDANCE SYSTEMS EMERGENCY LIGHTING. Photoluminescent Low Level Wayguidance Systems - Overview

Technical Datasheets. Everlux UL 924 Listed RUNNING MAN Sign C Product. 2. Product Description. 3. Quality and Certification

mason What It Means To Be Green VINYL WALLCOVERING High Durability (Fed. Spec. CCC-W-408D) Fire Testing Type II

Low Location Lighting

Duron Seamless Floor System

JESSUP JESSUP. GLO BRITE EXIT AND EGRESS Photoluminescent signs and tapes. Adhesive Coated Films. Adhesive Coated Films. Jessup Manufacturing Company

For more information on Tarkett go to

Made for people. Designed for possibilities. Altro Wood Safety collection Pendulum test PTV year 36 R 10 product guarantee

venetian plaster exclusivewallcovering Low VOC LEED IEQ 4.2 CAL 1350 & CHPS certified VINYL WALLCOVERING Fire classification

Sports flooring - Altro in the sporting arena

A COPYRIGHT NOTICE. version 3 FLOOR COVERING STANDARD SYMBOLS ELASTISCHE, TEXTILE UND LAMINAT BODENBELÄGE INTRODUCTION.

chiang mai What It Means To Be Green VINYL WALLCOVERING High Durability (Fed. Spec. CCC-W-408D) Fire Testing Type II

Cleaning and Maintenance Guide.

Draft for Comment Please comments to Part A(i)

Photoluminescent maritime safety signs

Care and Maintenance

Y S L V i z L i t e 3 0 2

Ecoglo Photoluminescent Markings

Web:

Raw Copper Rust. Finish: Honed Recycled materials: 65% Variation: Size/thickness: 6 x 24 x 3/8 nominal 1. PRODUCT NAME 2. PRODUCT DESCRIPTION

Care and maintenance instructions for products supplied by VEKSØ A/S

CARE INSTRUCTIONS BOOKLET

Roofing Adhesive SARNACOL 2172 Spray

Flexible Heaters. of Silicone Rubber & Kapton

DUOPEX WATER MANUAL mm WM WMKA021044

Tile Tech Warnings. Paving America one step at a time! MANUFACTURER OF DETECTABLE WARNING PAVERS AND TILES

PRODUCT BULLETIN & APPLICATION INSTRUCTION

Compliance Guide 2015 NFPA 101 LIFE SAFETY CODE EXIT STAIR PATH MARKINGS. for Ecoglo Photoluminescent Markings to meet the requirements of

Successful Installation. of PHOTOLUMINESCENT EXIT PATH MARKING SYSTEMS

A proud Australian tradition for over 50 years...

Technical. Data Sheet. 3M Scotchlite Reflective Material 5535 Segmented Flame Resistant Trim. October Description. Retroreflective Performance

DURAWAY DOORMAT SYSTEMS

DUOPEX WATER MANUAL mm

FIRST-CLASS IN TRAINS

24 Hour Permanent Step Edge Contrasting and Photoluminescent Path Marking Systems

CARE INSTRUCTIONS BOOKLET

Photoluminescent emergency pathway marking systems bring a new level of safety to manufacturing environments.

SAFETY ZONE SHEET & TILE MAINTENANCE

THE FIRST CHOICE FOR LANDSCAPERS & BUILDERS CLICK TO START

Chinastars reflective fabrics

Optics & Radiometry Laboratory

GRANITE COMPOSITE SINK

Standard Test Method for the Evaluation of Texture Appearance Retention of Carpets for Minimum Carpet Standards Program 1. Scope

SAFETY ACTION NOTICE By arrangement with the NHSScotland Property and Environment Forum

SUNBEAM IRON. User Guide SR6300 SR6400. SR6300 Sunbeam Sprint Iron SR6400 Sunbeam Aerostream Iron

SAFEGUARD RANGES SLIP RESISTANT VINYL SHEET SAFEGUARD DESIGN SAFEGUARD R10, R11, R12

YOUR GUIDE. Product Maintenance Guide. How to look after your product. PVC-U Windows, Doors & Conservatories

(front cover) Tatami Nara, ashlar. (left) Tatami Straw and Rush, monolithic. (back cover) Tatami Zen.

Consumer Flooring Guide. Maintenance and Warranty Information.

Care and Maintenance

ENCIMERAS DE COCCIÓN VITROCERÁMICAS PIANI DI COTTURA IN VETROCERAMICA TABLES DE CUISSON VITROCÉRAMIQUES

MAINTENANCE AND CARE GUIDELINES

High-Speed Roll Doors An intelligent entrance solution for every location. ASSA ABLOY Entrance Systems

SilverScreen. The innovation in solar heat and light control

Page PRODUCT DESCRIPTION

For more information on Smart Architectural Aluminium visit The art of creative living. alitherm windows & doors

Maintenance Guide. for your Mercier prefinished floor PRINTED IN CANADA SP-CAREGUBIL 04-15

How to Maintain Your Resin Floor

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

MAINTENANCE AND CARE GUIDELINES

INSTALLATION & MAINTENANCE

Teles Rubber Tile Maintenance Instructions

The Supporting Facts About Carpet Cushion

SOFA BUYING GUIDE A FIRSTLY CHECK THE DIMENSIONS OF THE INTENDED LOCATION FOR THE PRODUCT

Fortrac 3D Geogrid. High-Tensile Anti-Slip Reinforcement with Soil Retention Function

marmoleum modular tiles planks

Graphic Products,

The Supporting Facts About Carpet Cushion

SPIDER P SPIDER P mineral

Smart Compact Mobile "L" Cabinet

KARCHER RANGE 2016 JANUARY 2016

METAL PEDESTALS. By Actiu.

V100/V200. Providing spacious environment

ANSI NFSI B101.0 Walkway Auditing Standard. Brent Johnson Traction Auditing LLC

U V S R2 W INSTRUCTION MANUAL ENGLISH G H PRINTED IN P.R.C /01

DUCTING & VACUUM HOSE

RoHS. Specification SAWW9H0A. 서식번호 : SSC-QP (Rev.00)

laboratory & sterilization technology

HD 5/11 C Plus. Automatic pressure cut-off. Pump technology

ILLUMINO TASK SEATING. The Australian made Illumino task, contemporary task. Lic: C H S GECA Furniture and Fittings

made in germany The art of controlling light ARTec Alulux external Venetian blind technology Alulux zip textile screens

Quality comes as Standard

Luckdrops. Technical Spec Sheet. Studio+ Modular Home

LOVIN MY LAMINATE FLOORING CARE & MAINTENANCE TIPS

RESILIENT FLOORING CARE AND MAINTENANCE GUIDE

Maintain and restore hard floors

This document is a preview generated by EVS

Radiation and Laser Safety

Rhinoskin Spray On Insulation Ceramic Insulation Coating

VIBRA-series: VIBRA, VIBRA +

LIMITED METAL WARRANTY

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

Smarter Surfaces Product. Catalogue. website

The Yellow Can Removes oils & fatty acids

Report of Materials and Equipment Acceptance Division

Operation & maintenance information. for windows, doors and conservatories

Transcription:

SIZES AVAILABLE INDUSTRIAL: pg1 PRODUCT CODE DIMENSIONS ALN1 ALN2 ALN3 ALNCP VISISTRIP

SIZES AVAILABLE pg2 Architectural Step Covers are available at any lengths up to 6 metres. Special run profile can be produced subject to order volume. Maximum length of extrusion is 6.0 meters. Please be aware that the shipping of longer lengths can sometimes be problematic and expensive. Maximum length of clear front lens and non-slip insert material is 2.4 meters. Maximum length of GlowStrip is 2.0 meters. COLOURS AVAILABLE The aluminium profiles are supplied with a robust, easy to maintain anodised finish as standard. The colour of the anodised finish is natural or sometimes called bright metal finish. The safety non-slip inserts are available in black or in yellow colour. GLOWSTRIP is a green/yellow colour in daylight and glows green in darkness.

PHYSICAL PROPERTIES INDUSTRIAL: pg3 Architectural Stair Covers are assembled from a number of individual components and the physical properties of each of these components is examined below. ALUMINUM The aluminium metal used in the manufacture of Safety Step architectural step covers is the highest grade architectural alloy available. Alloy 6060 temper T5 is used. The ANODISED FINISH is a full 15 micron clear finish that provides a robust, durable and attractive finish. PVC SAFETY INSERT or GripStrip is a high performance, custom manufactured material that offers high traction and high wear characteristics. It is made from a reinforced, multi layered PVC based material including a stable base layer followed by a reinforcement layer to provide dimensional stability then a coloured PVC layer and finally topped off with a unique textured layer that provides the non-slip feature. Technical Data of the Gripstrip Product Parameter Dimension Specification Tolerance Test method Width cm 20 min. MSZ EN 426 Thickness mm 1,3 +0,13; -0,10 MSZ EN 428 Weight g/m2 1900 +13%; -10% MSZ EN 430 Wear layer density kg/m3 1250 ±50 MSZ EN 436 Dimensional stability (L/C) % ±0,20 Max. MSZ EN 434 Curling mm 8 Max. MSZ EN 434 Flexibility (diameter 20/40 mm) visual evaluation no damage - MSZ EN 435 Light fastness grade 6 min. MSZ EN ISO 105-B02 3. method Adhesion resistance of top layer N/50 mm 50 min. MSZ EN 431 Abrasion group - T - MSZ EN 660-1 Wear layer thickness mm 0,5 +13%; -10% MSZ EN 429 Castor chair visual evaluation no damage - MSZ EN 425 Residual indentation mm 0,1 Max. MSZ EN 433 Informative Data of the Gripstrip Product Parameter Dimension Specification Tolerance Test method Chemical resistance visual evaluation high resistance - MSZ EN 423 Slip resistance class DS - EN 13893 Wet COF: 0.51 AS/NZS3661.1:1993 Reaction to fire class Cfls1 - EN 13501-1 Standard roll length lm 25 - MSZ EN 426

INSTALLATION pg4 Architectural Step Covers are most commonly fixed in place with strong and permanent urethane adhesive mastic. We recommend a fast curing medium foaming urethane adhesive. The underside of Adverstep top plate has been carefully profiled to assist with strong bonding by adhesives. Recommended adhesives include: Sika 11FC Simson 70-02 Selleys Liquid Nails Direct Stick LF Ensure that both the underside of the Step Cover and the stair tread are dry, clean and free from grease oil and dirt. A solvent such as isopropyl alcohol is ideal to clean the surfaces. Apply the mastic is a bead as shown below and ensure the Step Cover beds down into the mastic without actually touching the stair tread. Alloy sufficient time for the adhesive to dry before allowing traffic on the stair. MAINTENANCE Architectural Stair Covers can be easily maintained to preserve the smart appearance and effective non-slip qualities. Because of the extreme hardness and chemical resistance of Architectural Stair Covers, cleaning can be effected with low pressure steam or water, degreasers or detergents. Stubborn soilage can be removed with a stiff deck broom. Do not use scrapers, strong solvents or wire brushes

TECHNICAL SPECIFICATIONS INDUSTRIAL: pg5 SLIP REISTANCE The coefficient of friction (COF) is a number which represents the friction between two surfaces. Friction is of course the resistance an object encounters in moving over another, so when we quote a COF figure for our anti-slip products we are quoting the measure of our products ability to provide safe traction and thereby prevent slips and falls. Different countries and indeed different agencies within a country adopt and rely on different testing apparatus to gain COF results. Safety Step has had test results produced from the three internationally most widely accepted slip metres: The Brungraber Mark II The English XL VIT The British Pendulum Slip Tester Safety Step Architectural safety products have been tested with the above apparatus and found to comply with and exceed the requirements the following Standards: ASTM F1677 ASTM F1679 NFPA 1901 DIN 51130 AS/NZS 4586 LUMINANCE DATA GLOWSTRIP Blended Strontium Aluminate pigment applied over a sheet aluminum base makes up the material included within Architectural Stair Covers to cause them to glow in the dark. This material is non-toxic and non-radioactive. The following chart maps the luminance decay of Safety Step glow in the dark GlowStrip. Luminance performance has been measured and charted from initial darkness to a condition of 0.3 milli candelas per square meter, the visibility threshold of the human eye. The luminance measurements were made on the photo luminescent test samples with the ITS License Plate Test Apparatus. The center of each test sample was measured initially, after 5 minutes, after 10 minutes, after 30 minutes, after 1 hour and after 2 hours. The aperture of the Pritchard Telephoto meter was adjusted to achieve the proper measuring area (two inches diameter) on the test samples. The ITS License Plate Test Apparatus is traceable to the National Institute of Standards and Technology through the calibration of the Optronic Luminance Standard. The test samples were exposed to 1,000 lux illumination from a 150 watt Xenon light source for 5 minutes immediately prior to the initial luminance measurements. Luminance measured in mcd/m2 Product Initial 5 mins 10mins 30mins 60mins 120mins Time to 0.3 Mcd/m2 Strontium Aluminate 2,980 550 292 87 40 18 5,170