standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

Similar documents
mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

STANDARD/quick. Sprinkler 42o. August 8, 2011

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

TECHNICAL DATA. Page 1 of 5

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

mirage standard response concealed pendent sprinkler vk492 (K5.6)

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

sprinkler vk538 (K11.2)

December 14, 2015 Page 1 of 7 TECHNICAL DATA

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

MIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

Quick response concealed horizontal sidewall sprinkler VK481

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

microfast sr/qr extended coverage pendent sprinkler

freedom residential concealed pendent Sprinkler vk458 (K7.4)

Standard Spray concealed horizontal sidewall sprinkler VK481

microfast quick response extended coverage hsw sprinkler vk606

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

TECHNICAL DATA. Page 1 of 6

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

quick response horizontal sidewall sprinkler vk360 (K8.0)

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

TECHNICAL DATA OBSOLETE

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

standard/quick response extended coverage light and ordinary hazard elo sprinklers

standard response/ quick response extended coverage

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

freedom residential concealed pendent sprinkler VK488 (K3.0)

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

microfast quick response Pendent sprinkler VK302 (K5.6)

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

micromatic Standard response Horizontal Sidewall sprinkler

TECHNICAL DATA. The Viking Corporation s Web site at Overall Length (Sprinkler Body): 2-5/16 (59 mm)

quick response Sprinkler 105a October 25, 2010

standard response Fusible Link Upright sprinkler VK204 (K8.0)

freedom residential concealed pendent lead free sprinkler

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

standard response dry horizontal sidewall sprinklers

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

microfast and microfasthp quick conventional sprinklers

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

micromatic standard response stainless steel sprinklers

standard response large orifice dry

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

standard response fusible link sidewall sprinkler VK112 (K5.6)

Microfast quick response Fusible element hsw sprinkler

standard response dry horizontal sidewall sprinklers

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

freedom residential concealed pendent sprinkler vk474 (K5.8)

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

FREEDOM RESIDENTIAL CONCEALED PENDENT LEAD FREE SPRINKLER VK4570 (K4.9) TECHNICAL DATA

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

standard response elo upright sprinkler

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

standard response elo upright and pendent sprinklers (storage-density/area)

micromatic standard response Upright sprinkler VK100 (K5.6)

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

Transcription:

January 1, 2011 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Concealed Pendent Sprinklers VK614 and VK616 are thermosensitive spray sprinklers pre-assembled with a threaded adapter for installation with a domed cover. The small glass bulb operating element and special deflector combine speed of operation and area of coverage to meet quick response standards. The cover plate provides up to 1/2 (12.7 mm) of vertical adjustment and is available with several decorative finishes to meet design requirements. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The push-on, thread-off design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. 2. LISTINGS AND APPROVALS For Light Hazard Occupancies Only culus Listed: Category VNIV Refer to the Approval Chart on page 88c and Design Criteria on page 88d for culus Listing requirements that must be followed. 3. technical data Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar). Factory tested hydrostatically The Viking Corporation s Web site at to 500 psi (34.5 bar). Testing: U.S.A. Patent No. 4,831,870 http://www.vikinggroupinc.com. Thread size: The Web site may include a more recent Part No. 06778BA-X: 1/2 (15 mm) NPT edition of this Technical Data Page. Part No. 07077A-X: 3/4 (20 mm) NPT Nominal K-Factor: Part No. 06778BA-X: 5.6 U.S. (80.6 metric ) Part No. 07077A-X: 8.0 U.S. (115.2 metric ) Metric K-factor measurement is shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 F (-55 C) Overall Length (Sprinkler Body): Part No. 06778BA-X: 2-5/16 (59.4 mm) Part No. 07077A-X: 2-7/16 (61.3 mm) Material Standards: Sprinkler Frame: Brass UNS-C84400 or QM Brass for Sprinkler 06778BA-X. Brass UNS-C84400 for all other sprinklers. Deflector: Brass UNS-C26000 or Phosphor Bronze UNS-C51000 Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Screw: Brass UNS-C36000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover: Copper UNS-C11000 and Brass UNS-C26800 Spring: Nickel Alloy Solder: Eutectic Sprinkler 88a Form No. F_061603 Replaces page 88a-f dated May 14, 2010. (Revised finish suffixes for white, black, and ivory painted cover finishes.)

Sprinkler 88b January 1, 2011 Ordering Information: (Also refer to the current Viking price list.) Viking Standard/Quick Response Extended Coverage Concealed Pendent Sprinklers and Cover Plate Assembly must be ordered separately: Sprinklers: Base Part No. 06778BA-X or 07077A-X (includes sprinkler and adapter pre-assembled, with a protective plastic cap covering the unit). Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix ( F/ C): 135 /57 = A, 155 /68 = B, 175 /79 = D For example, sprinkler VK614 with a 175 F/79 C temperature rating = 06778BADX. Note: When ordering this sprinkler using the SIN, add suffix -D. For example, concealed sprinkler VK614 = VK614-D. Cover Plate Assembly: Base Part No. 12381 Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/B Temperature Suffix ( F/ C): 135 /57 = A, 165 /74 = C For example, cover 12381 with a Polished Chrome finish and a 165 F/74 C temperature rating = 12381FC. Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the Sprinkler Accessories section of the Viking data book.) Sprinkler Wrench: Part No. 13577W/B** (available since 2006) **A ½ ratchet is required (not available from Viking). Sprinkler Cabinet: Part No. 01731A (available since 1971) 4. Installation Refer to appropriate NFPA Installation Standards. 5. Operation During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availability The Viking Model VK618 Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. Guarantee For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Figure 1: Concealed Sprinkler VK614 and Cover 12381

January 1, 2011 Sprinker 88c Sprinkler Temperature Classification TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Nominal Temperature Rating 1 Maximum Ambient Ceiling Temperature 2 Bulb Color Temperature Rating of the Required Cover Assembly Ordinary 135 F (57 C) 100 F (38 C) Orange 135 F (57 C) Ordinary 155 F (68 C) 100 F (38 C) Red 135 F (57 C) Intermediate 175 F (79 C) 150 F (65 C) Yellow 165 F (74 C) Cover Plate Finishes: Polished Chrome, Painted White, Painted Ivory, or Painted Black 1 The sprinkler temperature rating is stamped on the deflector. Footnotes Cover Plate Assembly Base Part Number 3 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 12381 Figure 3: Identification of Custom Paint Color for Concealed Covers Figure 2: Sprinkler Installation and Correct Use of Wrench 13577W/B

Sprinkler 88d January 1, 2011 Sprinkler Base Part Number 1 SIN Approval Chart Standard/Quick Response Extended Coverage Concealed Pendent Sprinklers NPT Thread Size Nominal K-Factor For Light Hazard Occupancies Only. Maximum 175 PSI (12 Bar) WWP Maximum Areas of Coverage 4 Minimum Water Supply Requirements 4 Flow/Pressure Listings and Approvals 3 (Refer also to Design Criteria on page 88e.) Inches mm U.S. metric 2 (Length x Width) culus 5 FM NYC Sprinkler Temperature Ratings A - 135 F (57 C) and 155 F (68 C) B - 135 F (57 C) C - 155 F (68 C) D - 175 F (79 C) Standard Response Applications 7 Quick Response Applications 16 x 16 (4.9 m x 4.9 m) 16 x 16 (4.9 m x 4.9 m) Cover Assembly Temperature Ratings 8 W - 135 F (57 C) cover 12381 1 X - 165 F (74 C) cover 12381 1 Footnotes 33 gpm @ 34.7 psi (124.9 L/min @ 2.39 Bar) 33 gpm @ 17.0 psi (124.9 L/min @ 1.17 Bar) 40 gpm @ 51.0 psi (151.4 L/min @ 3.52 Bar) 40 gpm @ 25.0 psi (151.4 L/min @ 1.72 Bar) 26 gpm @ 21.6 psi (98.4 L/min @ 1.49 Bar) 26 gpm @ 10.6 psi (98.4 L/min @ 0.73 Bar) 33 gpm @ 34.7 psi (124.9 L/min @ 2.39 Bar) 33 gpm @ 17.0 psi (124.9 L/min @ 1.17 Bar) 40 gpm @ 51.0 psi (151.4 L/min @ 3.52 Bar) 40 gpm @ 25.0 psi (151.4 L/min @ 1.72 Bar) 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. AW1, DX1 -- See Footnote 6. AW1, DX1 -- See Footnote 6. Cover Plate Finishes 9 1 - Polished Chrome, Painted White, Painted Ivory, or Painted Black 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 For areas of coverage smaller than shown, use the Minimum Water Supply Requirement for the next larger area listed. Flows and pressures listed are per sprinkler. 5 Listed by Underwriter s Laboratories, Inc. for use in the U.S. and Canada for Light Hazard occupancies with smooth, flat, horizontal ceilings only. 6 Meets New York City requirements, effective July 1, 2008. 7 culus Listings are limited to Light Hazard occupancies, where allowed by the installation standards being applied. 8 The 135 F cover has an orange label. The 165 F cover has a white label. 9 Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3.

January 1, 2011 Sprinkler 88e culus Listing Requirements: DESIGN CRITERIA (Also refer to the Approval Chart on page 88d.) Standard/Quick Response Extended Coverage Concealed Pendent Sprinklers VK614 and VK616 are culus Listed for installation in accordance with the latest edition of NFPA 13 for pendent spray sprinklers: Limited to Light Hazard occupancies, where allowed by the installation standards being applied, with smooth, flat, horizontal ceilings only. DEFLECTOR POSITION: Install with the deflector 3/8 (9.5 mm) to 7/8 (22.2 mm) below the ceiling. Refer to Figures 3 and 4. Minimum spacing allowed is 8 ft. (2.4 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to pages EC1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Figure 4: Sprinkler Dimensions and Cover Installation for Sprinkler VK614 with up to 1/2 (12.7 mm) Cover Adjustment Available

Sprinkler 88f January 1, 2011 Figure 5: Sprinkler Dimensions and Cover Installation for Sprinkler VK616 with up to 1/2 (12.7 mm) Cover Adjustment Available Form No. F_061603 Replaces page 88a-f dated May 14, 2010. (Revised finish suffixes for white, black, and ivory painted cover finishes.)