SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

Similar documents
E x t E N d e d Co v e r ag e S p r i n k l e r s. Office Buildings Hotels Hospitals Libraries. High-Piled Storage Big-Box Retailing

TECHNICAL DATA. UL/C-UL Listed as a standard response. horizontal ceilings. Listings up to a OBSOLETE

A sprinkler operates automatically when the heat-actuated element is heated to, or above, its thermal rating.

microfast quick response extended coverage hsw sprinkler vk606

standard/quick response extended coverage light and ordinary hazard elo sprinklers

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

STORAGE FIRE PROTECTION SPRINKLERS

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

Non-Storage / Special Protection / Storage Sprinklers

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

Sprinkler Identification Numbers

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2)

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

microfast sr/qr extended coverage pendent sprinkler

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

SPRINKLER HEAD. Upright, Pendent & Recessed Pendent Sprinklers MODEL: SD1010, SD1015, SD1030, SD1032 DESCRIPTION TECHNICAL SPECIFICATION

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

Residential Sprinkler For Sloped Ceilings

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE

Norminal Sprinkler Temperature Rating

Norminal Sprinkler Temperature Rating

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

freedom residential horizontal sidewall sprinkler Vk450 (k4.2)

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

freedom residential flush pendent sprinkler vk476 (K4.9)

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Exaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

SPRINKLER HEAD. Vertical Sidewall Sprinkler MODEL: SD2133, SD2121 DESCRIPTION MAXIMUM COVERAGE TECHNICAL SPECIFICATION SPRINKLER OPERATION RATINGS

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

micromatic standard response Upright sprinkler VK100 (K5.6)

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

micromatic standard response stainless steel sprinklers

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

esfr pendent sprinkler vk510 (k25.2)

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

mirage standard response concealed pendent sprinkler vk492 (K5.6)

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

TECHNICAL DATA OBSOLETE

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

micromatic Standard response Horizontal Sidewall sprinkler

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

DISCONTINUED PRODUCT

TECHNICAL DATA OBSOLETE

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

TECHNICAL DATA OBSOLETE

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

standard response elo upright sprinkler

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

freedom residential Upright sprinkler vk467 (k4.9)

TECHNICAL DATA MODEL V-HIP SPECIFIC APPLICATION ATTIC SPRINKLER VK660

TECHNICAL DATA. Page 1 of 5

File Ex643 Project 95NK34821 Project 96NK19119 Project 97NK2995 Project 98NK20794 Project 99NK21353 *Project 03NK33

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

STANDARD/quick. Sprinkler 42o. August 8, 2011

December 14, 2015 Page 1 of 7 TECHNICAL DATA

freedom residential horizontal sidewall lead free sprinkler VK4840 (k4.2)

freedom residential pendent sprinkler vk466 (K5.2)

standard response elo upright and pendent sprinklers (storage-density/area)

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

freedom residential concealed pendent sprinkler vk474 (K5.8)

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

Standard Spray concealed horizontal sidewall sprinkler VK481

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

standard response/ quick response extended coverage

esfr pendent sprinkler vk510 (k25.2)

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK460 (K5.8) TECHNICAL DATA

Storage Sprinkler U.S. Quick Reference Guide

esfr dry pendent sprinkler Vk502 (k14.0)

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

Transcription:

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL 60202 fpeschulte@aol.com 847/866-7479 SPRINKLER PROTECTION BASICS: TYPES OF : SPRAY - standard response - quick response - extended coverage - quick response extended coverage RESIDENTIAL OLD-STYLE FAST RESPONSE - quick response (QR) - quick response extended coverage (QREC) - early suppression fast response (ESFR) - quick response early suppression (QRES) - residential LARGE-DROP Building Code Resource Library 1 December 26, 2009

SPRINKLER ORIFICE SIZES: ORIFICE TYPE NOMINAL ORIFICE SIZE "K" FACTOR Small 1/4 Inch 1.3-1.5 Small 5/16 Inch 1.8-2.0 Small 3/8 Inch 2.6-2.9 Small 7/16 Inch 4.0-4.4 Standard 1/2 Inch 5.3-5.8 Large 17/32 Inch 7.4-8.2 Extra Large 5/8 Inch 11.0-11.5 Very Extra Large 3/4 Inch 13.5-14.5 Small orifice sprinklers permitted to be used under the following conditions: - Light hazard occupancy only and - Hydraulically calculated systems only and - Wet systems only and - Less water flow required than 1/2 inch sprinkler flowing at 7 psi and - Listed strainer provided for sprinklers with orifice size less than 3/8 inch. Building Code Resource Library 2 December 26, 2009

SPRINKLER TEMPERATURE CLASSIFICATION: TEMPERATURE CLASSIFICATION Ordinary Intermediate High Extra-high Very Extra-high Ultra-high Ultra-high TEMPERATURE RATING 135-170 o F 175-225 o F 250-300 o F 325-375 o F 400-475 o F 500-575 o F 650 o F MAXIMUM CEILING TEMPERATURE 100 o F 150 o F 225 o F 300 o F 375 o F 475 o F 625 o F Building Code Resource Library 3 December 26, 2009

SPRINKLER TEMPERATURE RATING IDENTIFICATION: TEMPERATURE CLASSIFICATION FRAME COLOR GLASS BULB COLOR Ordinary Brass or Black Orange or Red Intermediate White Yellow or Green High Blue Blue Extra-High Red Purple Very Extra-High Green Black Ultra-High Orange Black Ultra-High Orange Black Building Code Resource Library 4 December 26, 2009

STANDARD RESPONSE vs. FAST RESPONSE : Response Time Index (RTI) determined using the "plunge test". The "plunge test" involves placing a sprinkler in a test oven with a heated laminar airflow and determining the operating time of the sprinkler. 1/2 1/2 Fast response sprinkler definition: RTI < 50 meters -seconds 1/2 1/2 Standard response sprinkler definition: RTI > 80 meters -seconds Building Code Resource Library 5 December 26, 2009

GENERAL REQUIREMENTS: Only listed sprinklers permitted. Sprinklers required to be listed for a minimum working pressure of 175 psi. Coatings for corrosion-resistant sprinklers only permitted to be applied by the manufacturer. Sprinklers not permitted to be painted (except by the manufacturer). Upright sprinklers required to be installed with frame parallel to the branch line. Special (extended coverage) sprinklers permitted to be used based on testing. - Maximum area of protection per sprinkler protecting light or ordinary hazard occupancies limited to a maximum of 400 SF. - Maximum area of protection per sprinkler protecting extra hazard or high piled storage occupancies limited to a maximum of 196 SF. Special sprinklers designed for the protection of specific hazards or construction features permitted to be used based upon testing. Old-style sprinklers not permitted to be used in new installations. - Exception permits use of old style sprinklers in fur vaults and in special situations (such as the protection of piers and wharves). Upright and pendent spray sprinklers permitted to be used to protection all occupancy hazards in all building construction types. - Quick response sprinklers not permitted to be used to protect extra hazard occupancies (when the area/density (hydraulic) design method is used). Building Code Resource Library 6 December 26, 2009

(CONTINUED) GENERAL REQUIREMENTS: Sidewall spray sprinkler application limited to light hazard occupancies with smooth flat ceilings. - Exception permits sidewall sprinklers to protect ordinary hazard occupancies with smooth flat ceilings when specifically listed for ordinary hazard. Extended coverage sprinklers are only permitted to be used with unobstructed construction with smooth flat ceilings with a slope < 2 inches per foot. - Exception for specially listed sprinklers. - Exception for upright and pendent extended coverage sprinklers used with truss or bar joist structural system where the web members have dimensions < 1 inch. - Exception for specially listed sprinklers to be used with smooth flat ceilings with a slope < 4 inches per foot. Residential sprinklers permitted to be used in dwelling units and corridors adjoining the dwelling units. Residential sprinklers are only permitted to be used with wet systems. - Exception indicates that residential sprinklers are permitted to be used with dry system when the sprinklers are specifically listed for this application. When residential sprinklers are used within a compartment, all sprinklers within the compartment are required to be fast response type sprinklers. Building Code Resource Library 7 December 26, 2009

GENERAL REQUIREMENTS: Ordinary temperature sprinklers required to be used, except as follows: o - Ceiling temperatures exceed 100 F or - In ordinary or extra hazard occupancies, intermediate or high temperature sprinklers are permitted or - Sprinklers are located near heat-producing devices such as suspended heaters, ducts etc. Building Code Resource Library 8 December 26, 2009

STANDARD SPRINKLER LISTING REQUIREMENTS-UL 199: FIRE TEST: Sprinklers ability to control ceiling temperatures and limit fire damage (weight loss) is measured in the fire test. Test for standard sprinklers: - 4 open sprinklers arranged on a 10 ft x 10 ft spacing used. - Sprinkler discharge: a. Standard orifice (1/2 inch) sprinklers: between 15 and 25 gpm. b. Large orifice (17/32 inch) sprinklers: between 21 and 35 gpm. - Test fire consist of a 350 pound wood crib constructed of lumber which is ignited by n-heptane flowing continuously at a rate of 1 gpm. - Test room size: a. 60 FT X 60 FT b. Ceiling height: 15 feet, 9 inches - Water discharge from the sprinklers is not started until the crib is allowed to burn for a minimum of 1 minute after ignition; the ceiling temperature prior to water discharge must reach 1,400 o F. - Test criteria: o a. Limit the ceiling temperature to less than 530 F above ambient within 6 min- utes after crib ignition and b. Limit the weight loss to the crib to not more than 20% after a 30 minute burn. * * * * * Building Code Resource Library 9 December 26, 2009