CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

Similar documents
CONDENSERS AND CONDENSING UNITS

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Water-Source Heat Pumps

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

ALL PRODUCTS BROCHURE

Innovative Design, Performance, & Serviceability

THE ULTIMATE ROOFTOP SOLUTION

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Tulsa, OK Longview, TX

From 230 tons to. Water-Source Heat Pump Products. Premium Performance Environmentally Friendly Superior Construction

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

TECHNICAL SPECIFICATIONS

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

The ultimate fresh air solution.

RSMSD Technical Guide

TECHNICAL SPECIFICATIONS

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

T-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS MODELS UP TO 12.0 EER

RoofPak Applied Rooftop Systems

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

RSG16**S1M. Split System Air Conditioner 16 SEER

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Best Practices for Applied Rooftop ` Systems - Application and. Jerry Cohen President Jacco & Assoc. Installation

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

Best Practices for Applied Rooftop ` Systems, Applications and. Jerry Cohen President Jacco & Assoc. Installation

Energy Recovery with Cooling and Heating Model ERCH

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

C13-Series Engineering Guide

LIGHT COMMERCIAL. Product Line APPLICATIONS: » OFFICES» RETAIL STORES» RESTAURANTS» CLINICS» CONFERENCE CENTERS» RELIGIOUS» SCHOOLS.

Manufacturer Update 2014 IGSHPA

THE RIGHT SPEC. RIGHT NOW.

LIGHT COMMERCIAL. Packaged Units and Split Systems APPLICATIONS: OFFICES RETAIL STORES RESTAURANTS CLINICS

LL Series Chillers and Outdoor Mechanical Rooms. Engineering Catalog

RT-OA TM Rooftop Outdoor-Air (DOAS)

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Cultivator & Hybrid Cultivator

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Flexible & Innovative. Cooling Solutions

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

TECHNICAL SPECIFICATIONS

Greensource iseries Water Source Heat Pumps. SV Model. Made in Florida boschheatingandcooling.com

VariCool VAV Engineering Guide

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility

Commercial Packaged Rooftop Systems

VertiCool Aurora Engineering Guide

CF Series. Installation, Operation, & Maintenance. Condenser and Condensing Units WARNING

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

Reinventing Energy Efficiency

EC MODEL. EC Model & Split Systems Water Source Heat Pump. 6 to 30 tons

Commercial High-Efficiency Condensing Units

DIVISION 15 MECHANICAL

tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

Heat Pumps COMFORT NEED IT. When You

RHEEM PACKAGE GAS/ELECTRIC

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

Infinity 16 Heat Pump with Puron Refrigerant

Energy Recovery with Cooling and Heating

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

Technical Development Program

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing

Guide Specifications for InRow Direct Expansion

Commercial High-Efficiency Condensing Units

50TM TFF COMBINATION HEATING/COOLING UNITS

Air-Handling System Cooling Options

GARCIA GALUSKA DESOUSA Consulting Engineers

30GN FLOTRONIC II AIR-COOLED CHILLERS

50TM COMBINATION HEATING/COOLING UNITS

Inverter Ducted Split Air Source Heat Pump System with Inverter Drive Technology

2 shp 13 lc 1 36 t - 1 a

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Transcription:

CB/CF CONDENSERS AND CONDENSING UNITS CF CB Features: 2-70 ton air-cooled condensing units and remote air-cooled condensers Air-source heat pump configurations for energy efficient heating Variable capacity (10-100 % ) and two-step scroll compressors for load matching cooling and heat pump heating with improved part load efficiency. R-410A scroll compressors - one, two or four stages of cooling High efficiency variable speed ECM driven condenser fans CF offers an additional option of variable speed VFD controlled condenser fans Modulating hot gas reheat humidity control independently controls temperature and humidity Labeled components for quick and easy installation Labeled controls components with color-coded wiring that matches the unit wiring diagram included in the control compartment Matching indoor and outdoor air handling units available for a complete split system solution Application Flexibility Minimizes Installation Time and Reduces Cost High Efficiency Heat Pump Option Modulating Dehumidification Part Load Capability Quiet Operation

CB/CF CB/CF split system condensing units reflect the proven reliability and engineering excellence from the premier manufacturer of heating and cooling products. All selected options are factory installed to minimize field installation time and reduce cost. AAON CB/CF condensing units boast the same benefits that customers have come to expect from other AAON equipment: serviceability, quiet operation, reliability, high efficiency, durable construction, and a number of premier options that provide the flexibility to suit a wide variety of job requirements. CB Superior Features Cabinet is constructed of painted heavy gauge galvanized steel that surpasses a 2,500 hour salt spray test to provide the unit with corrosion protection. Single, easily removable, panel that provides access to the unit service compartments. Factory supplied and labeled split system copper stub outs with shut off valves for easy installation without the need to cut holes in the cabinet. Wrap-around, single row, high efficiency condenser coil with no additional rows to trap dirt and debris. A single row wrap-around coil is easier to clean than a multi-row wrap-around coil. Refrigerant circuits contain automatic low pressure and manual reset high pressure safety cut-outs, suction and liquid line Schrader valves, and a factory holding charge of R-410A. Heavy duty wire guards or painted louvered panels protect the condenser coil from damage and debris. Forklift slots in the base provide easy handling at the job site. Unit specific color-coded point-to-point wiring diagrams are provided and are laminated and permanently affixed inside the control compartment. CB Model 024 036 048 060 Compressors/ Circuit Discharge Direction 1/1 Vertical 37 All dimensions are in inches. Width Height Length 39 31 43 37 H W L CB (2-5 ton; 24-60 MBH)

Premier Options Lead variable or all variable capacity R-410A scroll compressors for load matching cooling, heat pump heating, and improved part load efficiency. Modulating hot gas reheat is available to provide energy efficient dehumidification, even with low sensible heat loads, without the temperature swings common with on/off reheat systems. Polymer e-coated or copper finned coils with stainless steel casing are available to extend the life of the coils and protect them in corrosive environments. Low ambient fan cycling or modulating head pressure control options (ECM driven or VFD controlled condenser fans) available to allow cooling operation down to 35 F ambient. Flooded condenser head pressure control options available to allow cooling operation down to 0 F ambient. 24v control circuit transformer to prevent exceeding the capacity of the air handling unit s control circuit transformer is standard in CF (option in CB ). High density foam compressor sound suppression blanket to reduce radiated noise. Hail guards protect the CF condenser coil from damage and debris. Optional 5 year compressor warranty. CB/CF Options } 10-100% variable capacity scroll compressors provide load matching cooling and improve part load efficiency. } Modulating hot gas reheat provides energy efficient dehumidification without temperature swings } ECM driven condenser fans for head pressure control and complete capacity modulation CB/CF

CB/CF CF Superior Features Cabinet is constructed of painted heavy gauge galvanized steel that surpasses a 2,500 hour salt spray test to provide the unit with corrosion protection. Unit compressors and controls are housed in a service compartment. Access doors with full length stainless steel piano hinges and lockable handles provide superior access and serviceability for the isolated compressor and controls compartment. Factory supplied and labeled split system copper stub outs with shut off valves for easy installation without the need to cut holes in the cabinet. CF 9 70 ton units are designed with removable access panels designed to simplify coil cleaning and service to the fans. Refrigerant circuits contain automatic low pressure and manual reset high pressure safety cut-outs, suction and liquid line Schrader valves, and a factory holding charge of R-410A. Rigid base design with forklift slots (2 25 & 30 tons) and lifting lugs (9 70 tons) provide easy handling at the job site. Unit specific color-coded point-to-point wiring diagrams are provided and are laminated and permanently affixed inside the control compartment. CF A Cabinet (2-7 tons) Condenser Coil Guards CF B Cabinet (9-15 tons) CF C Cabinet (16-25 & 30 tons) CF D Cabinet (26 & 31-70 tons)

CF Compressors/ Discharge Model Cabinet Width Height Circuits Direction 002 003 004 005 006 007 009 011 013 015 016 018 020 025 030 026 031 040 050 060 070 A B C D 1/1 Horizontal 2/2 4/2 or 4/4 Vertical Length Base Length Top 30 57 63 63 46 53 61 95 61 62 58 91 82 69 105 121 Variable Capacity Scroll Compressors CB and CF series units are available with variable capacity scroll compressors that can modulate from 10-100% capacity. This allows the system, with a matching AAON air handling unit, to maintain consistent supply air temperatures at all operating conditions. During part load operation, reducing compressor capacity increases part load efficiency and ultimately saves valuable system operating costs. Dehumidification CB and CF series units are available with modulating humidity control to provide energy efficient dehumidification, even with low sensible heat loads, without the temperature swings common with on/off reheat systems. Factory installed modulating valves allow only the necessary amount of reheat to create a consistent supply air temperature while maintaining space relative humidity. Air-Source Heat Pumps Air-source heat pumps provide energy efficient cooling and heating through the unit s refrigeration circuit. Air-source heat pumps transfer heat to the outside in the summer and to the space in the winter to provide both space heating and cooling. When paired with AAON air handling units, CB/CF air-source heat pumps can create a complete dual fuel split system with hot water, steam, electric, or gas heating. L T L T H H W CF Horizontal Discharge L B W L B CF Vertical Discharge CB/CF

CB/CF Serviceability Compressors are isolated from the condenser airflow and are included in the control compartment for easy service and scheduled maintenance. Durable double wall foam insulated access doors with lockable handles Removable panels provide access to clean the coils and service the fans. }

Optional WattMaster VCC-X controller includes onboard BACnet with a keypad and display. Only two shielded pairs run from the air handler to the CB/CF condensing unit (one system, one diagnostic) which simplifies field wiring. Split System Matching CB/CF condensing units can be paired with AAON H3, V3, M2, RQ, and RN air handling units. The AAON ECat selection software includes refrigeration options, such as Modulating Hot Gas Reheat or Flooded Condenser 0 F Low Ambient Controls, when matching an AAON split system. Pairing a CF condensing unit with an AAON air handling unit simplifies installation with factory supplied split system refrigerant line piping and wiring diagrams. A unit specific color-coded wiring diagram matches the labeled electrical components and color-coded wiring to make component identification simple. Labeled split system piping stub outs with shut-off valves allow for easy installation. CB/CF

AAON Environmentally Friendly HVAC Product Family Custom & Cataloged Air Handling Units (800-200,000+ cfm) Condensers & (2-230 tons) Chillers (Air-Cooled & Evaporative-Cooled) (4-540 tons) Rooftop Units (2-240 tons) Outdoor Equipment Rooms (Chillers, Boilers & Pumps) Self-Contained Units (3-70 tons) Residential Systems (2-5 tons) Heating and Cooling for... Auditoriums Convenience Stores Health Clubs Healthcare Facilities Homes Lodgings Manufacturing Museums & Libraries Natatoriums Office Buildings Restaurants Retail Stores Schools Supermarkets Geothermal & WSHP Units (1/2-230 tons) Air-Source Heat Pumps (2-230 tons) Heating and Cooling Coils (Booster, Hydronic, & DX) Defining Quality. Building Comfort. 2425 S. Yukon Ave. Tulsa, OK 74107-2728 www.aaon.com Fluid Coolers (50-450 tons) It is the intent of AAON to provide accurate and current product information. However, in the interest of product improvement, AAON reserves the right to change pricing, specifications, and/or design of its product without notice, obligation, or liability. Copyright AAON, all rights reserved throughout the world. AAON and AAONAIRE are registered trademarks of AAON, Inc., Tulsa, OK. CB/CF V76530 160425