EC MODEL. EC Model & Split Systems Water Source Heat Pump. 6 to 30 tons

Similar documents
EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

Greensource iseries Water Source Heat Pumps. SV Model. Made in Florida boschheatingandcooling.com

Greensource Residential Geothermal Heat Pumps. Think Green Think Renewable Think. iseries: SV Model Split System. boschheatingandcooling.

Residential Geothermal Heat Pumps Geo 3000 WA

Reinventing Energy Efficiency

Manufacturer Update 2014 IGSHPA

GUIDE SPECIFICATIONS AQUARIUS ii

Outstanding Performance; Application Flexibility

water to water heat pumps

Greensource Residential Geothermal Heat Pumps. Simply Smart. CDi Series: SM Model. boschheatingandcooling.com

GUIDE SPECIFICATIONS AQUARIUS ii

ES Model Water Source Heat Pump

DXair Pool Dehumidifiers

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

LM Split Systems Water Source Heat Pump

CONDENSERS AND CONDENSING UNITS

Greensource Residential Geothermal Heat Pumps. Invisible Comfort. Si Series: CE Model. boschheatingandcooling.com

Inverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com

LV Model Water Source Heat Pump

Greensource Residential Water Source Heat Pumps

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

18 SEER IDS Inverter Ducted Split

Inverter Ducted Split Air Source Heat Pump System with Inverter Drive Technology

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

MODULE-AIRE VERTICAL PACKAGE UNITS MB SERIES MB SERIES. Energy Wise HVAC Equipment

Flexible & Innovative. Cooling Solutions

C13-Series Engineering Guide

EP Model Water Source Heat Pump

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

Think Green Think Renewable Think

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

MC SERIES. Optional reverse cycle heating Takes full advantage of building diversity

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

VariCool VAV Engineering Guide

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

T-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS MODELS UP TO 12.0 EER

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

62DA,DB,DC,DD,DE,DF07-38

About Us Product Overview Complete Commercial Product Line Water Cooled Chillers Versatec Compact Series... 12

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

HORIZONTAL LOW PROFILE FAN COIL IN ROOM HORIZONTAL LOW PROFILE FAN COIL UNITS IN ROOM

Mammoth Water Source Heat Pumps

Rev. 2/13

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

PRODUCTS. Configurable Packaged Air Handling Equipment VRC SERIES

Guide Specifications PART 1 GENERAL 1.01 SUMMARY

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)

CoolSpot Engineering Guide

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

CA Model Water Source Heat Pump

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Think Green Think Renewable Think

Reinventing Energy Efficiency WARMNESS.

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Product Specifications. Vertical Floor Consoles By First Co.

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Are uncontrollable humidity problems costing you a bundle?

LV Split Systems Water Source Heat Pump

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Mission Critical Air Conditioning Systems

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

The ultimate fresh air solution.

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

LZT High efficiency air to water heat pumps with E.V.I. compressors

Modular Supply Make-Up Air Unit

THE ULTIMATE ROOFTOP SOLUTION

30GT FLOTRONIC AIR-COOLED CHILLERS

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

From 230 tons to. Water-Source Heat Pump Products. Premium Performance Environmentally Friendly Superior Construction

PACKAGED AIR COOLED Product Data Catalog

Split System Heat Pump Product Data

AMERICAN STANDARD 14 MODELS 4A7B E

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Water-Source Heat Pumps

Advance Release September 2009

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

SECTION WATER-SOURCE UNITARY HEAT PUMPS

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

ALL PRODUCTS BROCHURE

Product Data. Split System Heat Pump

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Self-Contained & Split System Reverse Cycle Air Conditioners Models

COMMON WATERSIDE ECONOMIZER APPLICATIONS:

AIR HANDLER R-410A Refrigerant 2-5 Tons. Submittal Data English Language/IP Units SD1008HN 07/15

Guide Specifications for InRow Direct Expansion

Transcription:

E & Split Systems Water Source Heat Pump 6 to 30 tons The E, including Split Systems, provides the best combination of performance, comfort and one-of-a-kind features that satisfy the high demands of any commercial building. E MODEL UP TO UP TO OP 24.5 5.6 GLHP WSHP ommercial Sales rochure fhp-mfg.com

High-Performance E Split Systems ll the excellent features, functions and benefits that are encompassed in the E package unit are available for the E Split System along with increased flexibility in installation and availability of applications. Increased Flexibility for Installation The E Split condensing section can be placed remotely up to a equivalent 75 feet from the air handler section, which allows for the unit installation to be in locations where space is limited. dditionally, this orientation allows installing the condensing section, which is the major contribu tor to noise and vibration, away from occupied areas. Multiple condensing units may be centrally located to facilitate servicing. The location of the E Split air handlers can be concealed within a variety of areas inside the building where it will connect to air and ventilation ducts to deliver comfort able air. ir handling sections are available in vertical or horizontal configurations to respect many different job site applications. See the below illustrations and the wide range of capacities the E Split System has available for designing in commercial buildings. NOTE: Extended performance data for the E Split Systems can be calculated by deducting 3% from the E package unit performance. (extended performance data is located in the E catalog or on the website at fhp-mfg.com) Technical Specifications E072-120 Vertical ir Handler E072-150 Horizontal ir Handler E072-120 Split Systems ondensing Section E150-360 Split Systems ondensing Section E150-360 Vertical ir Handler E150-3 ondensing Section Unit Dimensions (width) (depth) (height) E072 42.00 32.00 22.00 E096 42.00 32.00 22.00 E120 42.00 32.00 22.00 E150 80.00 32.00 22.00 E151 80.00 32.00 22.00 E180 80.00 32.00 22.00 E181 80.00 32.00 22.00 E210 80.00 32.00 22.00 E240 80.00 32.00 22.00 E300 80.00 32.00 26.50 E360 80.00 32.00 27.00 E072-360 Vertical ir Handler Unit Dimensions (width) (depth) (height) E072 42.00 32.00 41.00 E096 42.00 32.00 41.00 E120 42.00 32.00 41.00 E150 80.00 32.00 41.00 E151 80.00 32.00 41.00 E180 80.00 32.00 41.00 E181 80.00 32.00 41.00 E210 80.00 32.00 41.00 E240 80.00 32.00 41.00 E300 80.00 32.00 41.00 E360 80.00 32.00 61.00 E072-150 Horizontal ir Handler Unit Dimensions (width) (depth) (height) E072 38.00 78.00 21.00 E096 38.00 78.00 21.00 E120 38.00 78.00 21.00 E150 42.00 82.00 25.00 NOTE: ll dimensions in inches unless otherwise noted. ll dimensions within +-0.125". Specifications subject to change without notice.

ommercial Water Source Heat Pumps High-Performance E & E Split Systems The E water-to-air heat pump provides one of the best combinations of performance and efficiency available. Safety devices are built into each unit to provide the maximum system protection possible. Quiet omfort abinet - ll panels are insulated with ½" thick, 1.5 lb./cu. ft. dual-density fiberglass insulation for both thermal insulation and noise reduction. For vibration isolation, all compressors are mounted on rubber grommets. Vertical cabinets have an insulated divider panel between the blower compartment and the compressor section to minimize the transmission of compressor noise, and to permit operational service testing without air bypass losed-cell Foam Insulation (option) - Helps to provide cleaner, fiber-free air and reduces sound transmission ompressor lanket (option) - high density sound blanket that minimizes the transmission of compressor noise Service Friendly Unit rrangement - ll units are designed to be serviced from the front of the unit. Schrader valves for the high and low pressure gauges are standard, along with easily accessible electrical box components, allow the diagnosing and servicing of the unit to become a simple task. Insulated bulkheads in all vertical E s separate the compressor section from the blower section, allowing the unit to be serviced easily during operation. Panels are removable to facilitate servicing of the unit. Separate electrical knockouts in the unit corner post allow for easy and safe routing of high and low voltage lines to the inside of the cabinet Robust and Durable onstruction G90 Galvanized Steel abinet - Provides strength and corrosion protection upro-nickel oaxial Heat Exchanger (option) - Protects against corrosion when water conditions are of low quality Heat Pump Reciprocating and Scroll compressors* - Provides durability and ensures that each unit will provide many years of trustworthy performance Safety Flow Proving Switch (option) - Prevents the operation of the compressor should the water supply fail Unit Protection Module (UPM) - Monitors the unit operation and safety controls that protect the unit Dual Refrigerant Freeze Sensors - Monitors if refrigerant temperatures reach freeze limitations and disables unit to protect it ondensate Overflow Protection - ontinuously monitors the drain pan for high condensate water level, and if this exceeds normal operating levels, the compressor operation is interrupted to protect against drain pan overflow Quality Design & Efficiency oilerless ontrol (option) - Disables the compressor and/or activates a remote electric heater should the water temperature dropbelow set point Waterside Economizer (option) - Provides free-cooling without the use of mechanical cooling (compressors) Dual apacity - ll units are designed with dual refrigeration circuits for staged operation Options Designed for any pplication DuoGuard ir oil Protection The E is available with this state-of-the-art coil protection option that features two layers of corrosion protection. ll active copper heat transfer surface on the air coil is coated in a tin plating to resist all common forms of formicary coil corrosion. dditionally, the aluminum fins are pre-coated in a state-of-the-art gold enamel protective layer to provide a long service life in the harshest of environments, including sea coast installations. DuoGuard protected coils exceed 1000 hours of STM 117 salt spray testing. DD ontrols The optional factory mounted DD ontroller is preprogrammed and installed on the unit with the Unit Protection Module (UPM) to be job site ready. The unit will operate in a 100% stand-alone control mode or connect to a uilding utomation System (S) using open protocols net, Modbus, N2 or LonWorks (with an optional Lon card). Stand-alone DD modules must use FHP remote intelligent sensors; minor changes to operating points are made using a separate FHP view hand-held tool connected to either the DD unit controller or through NOTE: *E072 & E096 are provided with dual reciprocating compressors

the wall sensor. Zone temperature, leaving air temperature, and leaving water temperature can be monitored from the central control computer and unit fault indication displayed. DD Room and Zone Sensors To complement the controller, osch Thermotechnology orp. offers a line of intelligent FHP space sensors, which provide precision measurement and communication capabilities in an attractive low profile enclosure. On/Off Hot Gas Reheat llows the user to not only control space temperature, but also humidity levels within the conditioned space. Modulating hot gas reheat will maintain the leaving air temperature at a preset value to deliver neutral air to the space. 100% Outside ir The E is capable (as a special order) of providing 100% fresh outside air to most commercial buildings. The purpose is to deliver the make-up air dehumidified and reheated per the design requirements for space temperature, humidity and not to burden the recirculating units Technical Specifications Take-part onstruction To make installations possible into buildings where all that is available are standard-sized doorways and elevators, the take-apart option is the natural choice. dditional Features elt driven TXV 75V transformer dditional Options 100V transformer Hot water or chilled water coil Inverter duty fan motor Relays - EMS, blower monitor, compressor monitor, and pump/valve Phase monitor Fire alarm relay/dual power Wire to 208V Extended range with Schrader valve for head pressure control (by others) Variable frequency drive for fan motors Rotate blower 2" MERV-8 filter Single lower Large Vertical Dual lower Large Vertical E072-120 Single lower Large Dimensions (width) (depth) (height) E072 42.00 32.00 62.00 E096 42.00 32.00 62.00 E120 42.00 32.00 62.00 E0151-181 Single lower Large Dimensions E210-360 Dual lower Large Dimensions (width) (depth) (height) E210 80.00 32.00 62.00 E240 80.00 32.00 66.50 E300 80.00 32.00 66.50 E360 80.00 32.00 86.50 (width) (depth) (height) E151 52.50 32.00 70.00 E181 52.50 32.00 70.00 NOTE: ll dimensions in inches unless otherwise noted. ll dimensions within +-0.125". Specifications subject to change without notice.

Technical Specifications fhp-mfg.com E072-150 Large Horizontal E180-242 Large Horizontal E072-150 Large Dimensions (width) (depth) (height) E072 38.00 78.00 21.50 E096 38.00 78.00 21.50 E120 38.00 78.00 21.50 E150 42.00 82.00 21.50 E180-242 Large Dimensions (width) (depth) (height) E180 60.25 106.50 25.25 E242 60.25 106.50 36.00 NOTE: ll dimensions in inches unless otherwise noted. ll dimensions within +-0.125". Specifications subject to change without notice. Height excludes mounting rails. SHRE/HRI/ISO 13256-1 HRI ertified Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump GPM ooling 86 F Heating 68 F ooling 59 F Heating 50 F ooling 77 F Heating 32 F apacity tuh tuh/w apacity tuh OP apacity tuh tuh/w apacity tuh OP apacity tuh tuh/w apacity tuh OP E072 16 72000 13.0 92000 4.5 80400 18.6 72400 3.8 75600 14.2 54800 3.2 E096 21 96000 14.0 116000 4.8 116000 20.6 93200 4.2 104000 15.4 73600 3.5 E120 28 124000 13.2 158000 4.4 134000 18.3 123000 3.9 127200 14.7 100000 3.2 Performance in accordance with RI/ISO 13256-1 E150 35 157000 16.0 181000 5.6 185000 24.0 140000 5.0 166000 17.9 107000 4.2 E151 35 147000 16.0 181000 5.6 175000 24.0 140000 5.0 155000 17.9 107000 4.2 E180 42 182000 14.2 204000 5.0 195000 20.0 156000 4.2 185000 15.4 118000 3.5 E181 42 170000 14.2 204000 5.0 185000 20.0 156000 4.2 175000 15.4 118000 3.5 E210 50 220000 14.6 270000 5.1 292000 22.5 204000 4.5 250000 17.2 152000 3.9 E240 60 248000 14.4 315000 5.0 310000 21.1 250000 4.5 275000 16.0 180000 3.9 E242 60 248000 14.4 315000 5.0 310000 21.1 250000 4.5 275000 16.0 180000 3.9 E300 75 295000 13.0 376000 4.2 365000 18.8 300000 3.8 318000 14.0 222000 3.2 E360 90 386000 14.8 435000 4.2 472000 22.0 342000 4.0 412000 16.4 252000 3.3 NOTE: Ratings based upon HRI/NSI 13256-1 with 1" disposable filter

Electrical Data elt Drive Motor Voltage ode Voltage/ Ph/Hz Voltage Min/ Max ompressor Quantity RL LR Motor Quantity FL Total Unit w/elt Drive Motor Min ircuit mps Max Fuse mps E072 E096 E120 E150 E151 E180 E181 E210 E240 E242 E300 E360 1 208-230/1/60 197/253 2 13.0 74 1 7 36.3 45 3 208-230/3/60 197/253 2 7.8 68 1 3.6 21.2 25 4 460/3/60 414/506 2 3.9 34 1 1.8 10.6 15 1 208-230/1/60 197/253 2 15.7 84 1 8.4/9.8* 47.6/45.1* 50/60* 3 208-230/3/60 197/253 2 11.0 88 1 4.8/6.2* 29.5/31.0* 40/40* 4 460/3/60 414/506 2 5.4 44 1 2.4/3.1* 14.6/15.2* 15/20* 5 575/3/60 518/632 2 4.4 36 1 2.0/2.6* 11.9/12.5* 15/15* 1 208-230/1/60 197/253 2 26.3 134 1 9.8 69.0 90 3 208-230/3/60 197/253 2 15.6 110 1 6.2/9.2* 41.3/44.3* 50/50* 4 460/3/60 414/506 2 7.8 52 1 3.1/4.3* 20.6/21.9* 25/25* 5 575/3/60 518/632 2 5.8 39 1 2.6/3.7* 15.7/16.8* 20/20* 3 208-230/3/60 197/253 2 19.2 136 1 9.2 52.4 70 4 460/3/60 414/506 2 8.7 66 1 4.3 23.9 30 5 575/3/60 518/632 2 6.9 55 1 3.7 19.2 25 3 208-230/3/60 197/253 2 19.2 136 1 9.2 52.4 70 4 460/3/60 414/506 2 8.7 66 1 4.3 23.9 30 5 575/3/60 518/632 2 6.9 55 1 3.7 19.2 25 3 208-230/3/60 197/253 2 22.4 149 2 6.2 62.8 80 4 460/3/60 414/506 2 10.6 75 2 3.2 30.1 40 5 575/3/60 518/632 2 7.7 54 2 2.6 22.5 30 3 208-230/3/60 197/253 2 22.4 149 1 12.2 62.6 80 4 460/3/60 414/506 2 10.6 75 1 6.1 30.0 40 5 575/3/60 518/632 2 7.7 54 1 5.4 22.7 30 3 208-230/3/60 197/253 2 29.5 195 2 4.8 76.0 100 4 460/3/60 414/506 2 14.7 95 2 2.4 37.9 50 5 575/3/60 518/632 2 12.2 80 2 2 31.5 40 3 208-230/3/60 197/253 2 30.1 225 2 6.2 80.1 110 4 460/3/60 414/506 2 16.7 114 2 3.1 43.8 60 5 575/3/60 518/632 2 12.2 80 2 2.6 32.6 40 3 208-230/3/60 197/253 2 30.1 225 2 6.2 80.1 110 4 460/3/60 414/506 2 16.7 114 2 3.1 43.8 60 5 575/3/60 518/632 2 12.2 80 2 2.6 32.6 40 3 208-230/3/60 197/253 2 48.1 245 2 9.2 126.6 150 4 460/3/60 414/506 2 18.6 125 2 4.3 50.5 60 5 575/3/60 518/632 2 14.7 100 2 3.7 40.5 50 3 208-230/3/60 197/253 2 55.8 340 2 12.2 150.0 200 4 460/3/60 414/506 2 26.9 173 2 6.1 72.7 90 5 575/3/60 518/632 2 23.7 132 2 5.4 64.1 80 NOTE: *First value is for vertical configurations and second value is for horizontals. osch Thermotechnology orp. 555 NW 65th ourt Fort Lauderdale, FL 33309 Phone: 866-642-3198 Fax: 954-776-5529 fhp-mfg.com Printed on Elemental hlorine Free, FS-certified, minimum 10% PW paper with vegetable-based inks. Scan the QR code to the right to access product information. opyright 2014 osch Thermotechnology orp. ll rights reserved. Subject to change without notice. 76P995054 11-14