Installation, Operation, and Maintenance Manual Balston Model 76-01, 76-02, 76-10, and Membrane Air Dryers

Similar documents
Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

Nitrogen Generation Systems Compressed Air Dryers

Drying Compressed Air

Nitrogen Generation Systems Compressed Air Dryers

High Efficiency Coalescers Parker Filtration 8000 Series

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

Nitrogen Generation Systems Compressed Air Dryers

DRYAIRE DESICCANT SYSTEM MODEL 6760

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

MDX. Non-Cycling Refrigerated Compressed Air Dryers with Intellidrain Condensate Drain Trap. Operation & Maintenance Manual

Compressed Air Filters

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual

SYNRAD Technical Bulletin # 0015d

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

GRF-SERIES REFRIGERATION TYPE NON CYCLING STANDARD

DRYAIRE MEMBRANE AIR DRYING SYSTEM MODEL 6770

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

BULLETIN: APPL-QAF-133R1

VSA Series Air Dryer. User s Guide

Desiccant Air Drying System

CMMD Series Membrane Air Dryer

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL


Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250

DHW Series INSTRUCTION MANUAL. Pressure Swing Desiccant Compressed Air Dryer Models 7 through 50 scfm

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX

MDH Series Air Dryer. User s Guide

UltraDry s Features and Benefits

MODEL MW200 MODEL MW600 AIR DRYER

HEATLESS REGENERATIVE DRYERS

Desiccant Air Drying System

Moduflex. Desiccant Air Dryer P3TJA13A1AN - P3TJA13A7AN. USER GUIDE (Original Language) Dry Air System NL DE FR FI SV NO DA EL ES PT IT PL SK CS ET HU

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS

SFD. Suburban Filter Dryer. User Manual Installation Instructions

Pressure Swing Desiccant Dryers

20 21,250 SCFM GLOBAL AIR TREATMENT. FIL Series

DAD-500 (130026) DESICCANT AIR DRYING SYSTEM

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

D-Series 2 D 3. ultra-high purity compressed air dryers. Flow Capacity: Nm 3 /hr ( scfm)

ModulAir Air Dryer with External Purge Tank - Changeover from Bendix AD-IS for Peterbilt Installation. Air Dryer Mounting Bracket (Item 1)

Dry Air Pac ENGINEERED COMPRESSED AIR DRYING SYSTEMS FOR COLD STORAGE/ FREEZER ROOM DRY PIPE SPRINKLER SYSTEMS

Corrosion Dry Air Pak

industry revolves around VMMD Series Membrane Air Dryer

SECTION AIR COMPRESSORS AND ACCESSORIES

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

THERMAL MASS CYCLING REFRIGERATED AIR DRYERS. GTRC Series

Filters & Centrifugal Separators

Refrigerated & Desiccant Compressed Air Dryer Product Selector

Operations and Maintenance Manual

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Condensate Drain Valves

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

Compressed Air Dryers

NON-CYCLING REFRIGERATED AIR DRYERS. GSRN Series

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

P3X Series Membrane dryers

Clean, Dry Air System

Hybrid Refrigerated/Desiccant Compressed Air Dryers

ECS Protector Nitrogen Generator PGEN-40FK/PGEN-50FK/PGEN-60FK PGEN-40M/PGEN-50M/PGEN-60M

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

Membrane Technologies DMD Series Dryers ESM Series Dryers

Model OP155 Air Dryer

CFH Series High Efficiency Filters

HIGH INLET TEMPERATURE REFRIGERATED AIR DRYERS. GHRN Series

Operating Instructions Manual. Condensate Separators. Models 4GNL3 thru 4GNL9 and 53RG84 thru 53RG95

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252

New standard in compressed air treatment, providing Energy Savings up to 99%

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

DAD-500 (130026) DESICCANT AIR DRYING SYSTEM

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

Blower Purge Desiccant Compressed Air Dryers IBP SERIES 500-4,300 SCFM

One Less Thing to Forget...

AirCel. AG Aluminum. SH Steel. Industrial Filter Housings

AUTOTROL 363TC AUTOMATIC FILTER VALVE SERVICE MANUAL

MODULAR HIGH CAPACITY REFRIGERATED AIR DRYERS. GMRN & GMRC Series

DESICCANT AIR DRYERS. BD + CD + CD series

Heated Desiccant Air Dryer

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

ThermoStar Refrigeration Air Dryers

PROdry. High Inlet. Temperature. refrigerated. compressed air. dryers. Contents. For Sales & Service please contact:

SR Series Refrigerated Dryers SCFM

Compressed air preparation Compressed air storage Moisture management. Catalog #1

Installation Instructions PP-AS20 Anti-Scale System

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

EXTERNALLY HEATED DESICCANT AIR DRYERS. GEHD Series

Compressed Air Specialists

clean and quiet laboratory

UA Series Air Dryers. 10 Year Warranty Limited ( SCFM) Setting a new standard in Quality and Reliability WAS 360

Refrigeration Dryers WDRD

15Hp/20Hp Deluxe Compressor-Dryer System

Transcription:

Installation, Operation and Maintenance Manual Installation, Operation, and Maintenance Manual Balston Model 76-01, 76-02, 76-10, 76-20 and Membrane Air Dryers Model 76-20 Models 76-01, 76-02, 76-10 Figure 1 - Overall Dimension Drawings Model 76-40 These instructions must be thoroughly read and understood before installing and operating this product. Modification of the unit will result in voiding the warranty. If you have any questions or concerns, please call the Technical Services Department at 800-343-4048, 8AM to 5PM Eastern Time or email at balstontechsupport@parker.com (North America only). For other locations, contact your local representative. General Description CELL: SMD The Balston Membrane Air Dryers (see Figure 1) provide clean, dry compressed air from an existing compressed air supply through the use of state-of-the-art membrane technology. The dryers are capable of delivering dry air with a dewpoint of -40 F (-40 C). No electrical supply is required to use the Balston Membrane Air Dryer. Each membrane dryer is equipped with a high efficiency coalescing prefilter to remove oil, water, and particulate contamination to 0.01 micron. 1

Installation, Operation and Maintenance Manual Installation and Operation All installation, operation, and maintenance procedures for the Balston Membrane Air Dryers should be performed by suitable personnel using reasonable care. Warning: Use PTFE tape on all threaded components. Use of pipe sealants other than PTFE tape will damage the membrane and void the warranty. General Mounting For installations which run continuously, install a bypass line to handle air flow when the membrane dryer is off-line for periodic maintenance (see Figure 3). The bypass line should be equipped with a redundant drying system, or adequate filtration to condition the air to acceptable standards for short-term use. The Balston 76-01, 76-02, and 76-10 Membrane Air Dryer modules may be wall mounted in a vertical or horizontal position; however, the 76-20 and 76-40 modules may only be mounted in a vertical position. Note: Prefilters should always be mounted in a vertical position. The dryers are shipped from the factory ready to install with the module in the vertical position. For vertical installation (all models), simply secure the main bracket to the wall using the keyhole slots (see Figure 2) and install the membrane module bracket near the unsupported end of the module. For horizontal installation, the membrane module must Model 76-01, 76-02, 76-10 Model 76-20 Viewed from the rear Model 76-40 Figure 2 - Mounting Dimensions 2

Installation, Operation and Maintenance Manual be re-oriented prior to mounting. First, disconnect the membrane module from the tee fitting at the top of the module by loosening the hex nipple (see Figure 1). Next, remove the pipe plug from the tee fitting. Install the membrane module where the pipe plug used to be, and insert the pipe plug where the membrane module used to be, using PTFE tape (included) on all threaded fittings. Finally, mount the Balston Membrane Air Dryer on the wall using the keyhole slots on the back of the main bracket (see Figure 2) and install the membrane module bracket near the unsupported end of the module for stability. All mounting hardware should be adequately sized to support the weight of the dryer in its mounted position. Compressed Air If compressed air is supplied to the dryer from an elevated air line, a drip leg must be installed directly upstream from the dryer (see Figure 3). The compressed air supply pressure should be between 60 psig and 150 psig (4.1 barg and 10.3 barg) for proper operation of the dryer. The compressed air temperature should be within 10 F (6 C) of the ambient temperature and should not exceed 100 F (38 C) for optimal operation of the membrane dryer. Do not exceed inlet air recommended temperatures or the performance and life of the module may be adversely affected and the warranty will be void. If the compressed air supply contains excess water and/or oil, install an additional coalescing prefilter upstream from the Balston Membrane Air Dryer (see Recommended Accessories section). Shutoff Valve - A shutoff valve should be installed directly upstream from the dryer to facilitate routine maintenance and troubleshooting procedures. Use only a gate valve or other slowopening valve upstream from the dryer. Use of a valve which is not slow-opening will pressurize the membrane too quickly and may cause it to rupture. Membrane failures resulting from improper valve installation will not be covered under warranty. Drain Lines Operation Pressure Regulator - A pressure regulator should be installed directly upstream from the membrane dryer to set and maintain the inlet air pressure. Maintaining a constant inlet air pressure is critical to the performance of the system. Do not exceed 150 PSI inlet pressure. A pressure regulator should also be installed downstream from the membrane dryer to control the output pressure. Flow Controller - It is important to control the output flow from the dryer to avoid exceeding the rated capacity of the dryer. Install a flow controller downstream from the membrane dryer to control the flow to the process or equipment that uses the dry compressed air. If the maximum flow rate of the dryer is exceeded, the output air may not meet the published dewpoint specification. Dryer flow capacities as a function of inlet pressure are detailed in Table 1 in the Specifications section of this bulletin. Compressor - The Balston Membrane Air Dryers maintain a constant "sweep" flow to carry water vapor laden air away from the membrane module. The sweep flow rate at different pressures is shown in Table 2 in the Specifications section of this bulletin. This sweep flow results in a constant "hiss" of air from the module. The total compressed air consumption of the dryer is the sum of the downstream demand plus the "sweep" flow. The compressor must be adequately sized to supply this volume. All inlet piping and fittings should be the same size as the inlet port on the dryer. Use only PTFE tape on fittings installed upstream and downstream from the dryer. The use of pipe dope could lead to contamination of the dryer. The high efficiency coalescing prefilter integral to the Balston Membrane Air Dryer is equipped with an automatic float drain. The 1/4" flexible drain tubing from the drain will pass small quantities of water and compressor oil and should be piped away to a suitable containment device or drain. To operate the Balston Membrane Air Dryer, simply open the shutoff valve (customer installed) on the inlet air line, adjust the inlet air pressure using the (customer installed) pressure regulator, and adjust the outlet flow using the (customer installed) flow control device. The flow capacities for different inlet pressures and dewpoints are listed in Table 1 in the Principal Specifications table. 3

Installation, Operation and Maintenance Manual Figure 3 - Recommended Installation Note: If continuous operation is required, install a bypass line with redundant drying system (see page 2) Maintenance Depressurize the dryer prior to performing any service. The only maintenance required by the Balston Membrane Air Dryer is the replacement of the prefilter cartridge or cartridges (see Table below). The prefilter cartridges on the membrane dryer should be changed every 12 months*, or more often if needed. The prefilters protect the membrane module from contamination. Failure to service the prefilters on a regular basis can result in premature failure of the membrane module and void the warranty. The part numbers for the replacement filters are listed in the Ordering Information table at the end of this Maintenance section. (Note: If the prefilter on the dryer is equipped with a Balston Differential Pressure Indicator, the prefilter cartridge should be changed annually or when the indicator moves to "change", whichever occurs first.) The filter cartridges in the prefilter assemblies are removed by loosening the filter bowl or collar from the filter head, and unscrewing the element retainer from the base of the cartridge. Insert the new filter cartridge and reassemble the housing in reverse order. The time required to change the prefilter cartridge on the Balston Membrane Air Dryer is approximately 5 minutes. To ensure consistent product performance and reliability, use only genuine Balston replacement parts and filter cartridges. *Changing filter cartridges more frequently will translate into direct energy savings and reduced operating costs. Annual electricity costs to operate a typical 100 HP compressor can be as high as $50,000. Pressure drop in the system adds to this expense. A system operating at 100 psig that is experiencing a 2 psig pressure drop through a filter, requires an additional 1% in operating energy costs or approximately $500.00+ per year. Ordering Information Model Number 76-01, 76-02 76-10 76-20 76-40 Coalescing Prefilter Assembly 2002N-0B1-BX 2104N-0B1-BX 2208N-0B1-BX 2312N-0B1-BX Replacement Prefilter Cartridges 100-12-BX 100-18-BX 150-19-BX 200-35-BX Automatic Drain Kit 21552 21552 21552 21552 Replacement Membrane Module 76209 (1) 76221AL 76282AL 76282AL(2ea.) 76216 (2) 1 Replacement Module for 76-01 is P/N 76209. 2 Replacement Module for 76-02 is P/N 76216. 4

Installation, Operation and Maintenance Manual Recommended Accessories Balston Grade DX Compressed Air Filter Assembly The Balston Compressed Air Grade DX Filter Assembly is an excellent auxiliary prefilter for the Balston Membrane Air Dryer. See the table below for the recommended filter assembly for each dryer. When used as a prefilter, the Balston Grade DX Compressed Air Filter Assembly will remove excess oil, water and particulate contamination from the compressed air supply which feeds the Membrane Air Dryer. Ordering Information Recommended Accessories Part No. Description 2002N-1B1-DX Auxiliary Coalescing Prefilter Assembly, 1/4" ports (76-01, 76-02) 2104N-1B1-DX Auxiliary Coalescing Prefilter Assembly, 1/2" ports (76-10) 2208N-1B1-DX Auxiliary Coalescing Prefilter Assembly, 1" ports (76-20) 2312N-1B1-DX Auxiliary Coalescing Prefilter Assembly, 1-1/2" ports (76-40) 5

Installation, Operation and Maintenance Manual Pricipal Specifications Membrane Air Dryers Model Number 76-01 76-02 76-10 76-20 76-40 Dew Point -40 F (-40 C) -40 F (-40 C) -40 F (-40 C) -40 F (-40 C) -40 F (-40 C) Min/Max Inlet 60 psig/150psig 60 psig/150 psig 60 psig/150 psig 60 psig/150 psig 60 psig/150 psig Air Pressure (4.1 barg/10.3 barg) (4.1 barg/10.3 barg) (4.1 barg/10.3 barg) (4.1 barg/10.3 barg) (4.1 barg/10.3 barg) Maximum 5 psid 5 psid 5 psid 5 psid 5 psid Pressure Drop (1) (0.35 bar) (0.35 bar) (0.35 bar) (0.35 bar) (0.35 bar) Min/Max Ambient 40 F-100 F 40 F-100 F 40 F-100 F 40 F-100 F 40 F-100 F Temperature (2) (4 C-38 C) (4 C-38 C) (4 C-38 C) (4 C-38 C) (4 C-38 C) Inlet/Outlet Port Size 1/4" NPT (female) 1/4" NPT (female) 1/2" NPT (female) 1" NPT (female) 1 1/2" NPT (female)(3) Shipping Weight (4) 9 lbs (4 kg) 10 lbs (5 kg) 18 lbs (9 kg) 35 lbs (16 kg) 53 lbs (24 kg) Note: The Dryers in this bulletin are not recommended for use with FT-IR Spectrometers. Please refer to the AGS Product Catalog for FT-IR Purge Gas Generators. Notes: 1 5 psid (0.35 barg) @ -40 F (-40 C) dewpoint operating parameters. 2 The temperature of the inlet compressed air should be no more than 10 F (5.5 C) warmer than the ambient temperature. 3 The outlet port on the 76-40 is 1" NPT. 4 Shipping weights are approximate. Packaging materials may cause variations. Table 1 Flow Rates Outlet Flow (SCFM/lpm) at Indicated Operating Pressure (psig) for -40 F(-40 C) Atmospheric Dewpoint Model 60 psig (4 barg) 80 psig (5.5 barg) 100 psig (7 barg) 120 psig (8.3 barg) 140 psig (9.6 barg) 76-01 0.3(9) 0.6 (16) 1.0 (28) 1.3 (37) 1.7 (48) 76-02 0.6 (17) 1.0 (28) 2.0 (56) 2.6 (74) 3.4 (96) 76-10 3.0 (85) 5.0(142) 10 (283) 13 (368) 17 (481) 76-20 6.0 (170) 10 (283) 20 (566) 26 (736) 34 (962) 76-40 12.0 (340) 20 (566) 40 (1132) 52 (1472) 68 (186) Table 2 Membrane Module Regeneration Flow Regeneration Flow (SCFM/lpm) at Indicated Operating Pressure (psig) Model 60 psig (4 barg) 80 psig (5.5 barg) 100 psig (7 barg) 120 psig (8.3 barg) 140 psig (9.6 barg) 76-01 0.2 (4.8) 0.2 (5.9) 0.3(7) 0.3 (8.5) 0.3 (9.3) 76-02 0.3 (9.3) 0.4 (12) 0.5 (14) 0.6 (16) 0.7 (19 76-10 1.6 (45) 2.1 (59) 2.5 (71) 3.0 (85) 3.3 (93) 76-20 3.4 (96) 4.2 (119) 5.0 (142) 6.0 (170) 6.6 (186) 76-40 6.8 (192) 8.4 (238) 10.0 (283) 12.0 (340) 14.0 (396) 6

Installation, Operation and Maintenance Manual Recommended Accessories All troubleshooting activities should be performed by suitable personnel using reasonable care. Symptom Moisture Indicator (optional accessory) Turns Yellow Course of Action Check Inlet air temperature. If higher than 10 F (5 C) above ambient temperature, install aftercooler upstream from the dryer. Check inlet air pressure (60 psig/4.1 barg minimum). Check flow rate. Do not exceed dryer capacity (see Table 1). Install flow controller downstream. High Pressure Drop Through Dryer (low flow) Check drain for leaks. Replace automatic drain kit (P/N 21552) if necessary. Check flow demand. Match process flow requirements to dryer capacity (see Table 1). Check inlet filter for particulate clogging; replace if necessary. Check for leaks in dryer and downstream piping and process. No Flow Through Dryer Check supply line source (compressor). Check to make sure all customer installed valves are open. Check fittings and drain for leaks. Note: To arrange for system service, contact the Technical Services Department at 1-800-343-4048, 8AM-5PM Eastern Time or email at balstontechsupport@parker.com (North America only). For locations outside North America, please call your local representative. Don t Forget To: 1 Complete and mail your registration card. 2 Keep your product certification in a safe place. 3 Call the Technical Services Department at 800-343-4048, 8AM to 5PM Eastern Time with any questions or email at balstonthechsupport@parker.com (North America only). For locations outside North America, please contact your local representative. Serial Numbers The serial number label for the unit (76-01, 76-02, 76-10, 76-20, 76-40) is attached to the mounting bracket, between the prefilter and the membrane module. For your own records, and in case service is required, please record the following: DATE IN SERVICE SERIAL NO. Please have the serial number available when calling for assistance. Warranty (NORTH AMERICA ONLY) (FOR INFORMATION CONTACT YOUR LOCAL REPRESENTATIVE) Parker Hannifin guarantees to the original purchaser of this product, that if the product fails or is defective within 12 months from the date of purchase, when this product is operated and maintained according to the instructions provided with the product, then Parker guarantees, at Parker s option, to replace the product, repair the product, or refund the original price for the product. This warranty applies only to defects in material or workmanship and does not cover: ring and valve wear on compressors, routine maintenance recommended by the instructions provided with this product, or filter cartridges. Any modification of the product without written approval from Parker will result in voiding this warranty. Complete details of the warranty are available on request. This warranty applies to units purchased and operated in North America. 7

Installation, Operation and Maintenance Manual Member of 242 Neck Road, P.O. Box 8223 Haverhill, MA 01835-0723 Tel: 978-858-0505 Fax: 978-556-7501 www.parker.com/balston Parker Filtration & Separation Filtration Group Europe Hermitage Court, Hermitage Lane Maidstone, Kent ME16 9NT England Tel: +44 (01622) 723300 Fax: +44 (01622) 728703 www.parker.com/pag RECYCLABLE RECYCLABLE RECYCLABLE 8 Copyright 1994, 2008 Printed in U.S.A.