Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Similar documents
Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

Fire dampers. For diverse applications

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU

K*, R* Ventilation grilles

Kezdőlap > Termékek > Tűz és füst elleni védelem > Füstmentesítő csappantyúk > Típus EK-EU. Típus EK-EU

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

Type EK-EU FOR MECHANICAL SMOKE EXTRACT SYSTEMS AND AS AN ADDITIONAL SUPPLY AIR INLET, ALSO FOR NATURAL SMOKE AND HEAT EXHAUST SYSTEMS

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

Air distribution for clean rooms. Clever and flexible.

Type RM-O-3-D. Duct smoke detector used to prevent smoke from spreading through the ducts of ventilation and air conditioning systems

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

Ceiling diffusers. Type DLQL

Homepage > Prodotti > Sistemi di ventilazione decentralizzata > Dispositivi verticali > Type FSL-V-ZUS. Type FSL-V-ZUS

Type VDW WITH LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH INDIVIDUALLY MANUALLY ADJUSTABLE AIR CONTROL BLADES

Compact. Efficient. TROX.

Dual certification! Air handling units for potentially explosive atmospheres

Units for suspended ceilings

Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016

Decentralised ventilation

Ceiling swirl diffusers

Compact. Efficient. TROX.

Ceiling swirl diffusers

Chilled Ceiling Elements

Units for suspended cei lings

DACC Health Sciences Building Air Handler Assessment/Study

Passive chilled beams

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

SECTION AIR DUCT ACCESSORIES

Intumescent Fire Dampers

Fan Coil Unit CULTRA

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

Air distribution systems. Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

Life Safety Dampers Selection and Application Manual

TUNNEL FANS STANDARD AND HOT SMOKE

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING.

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Ceiling air diffuser INDULTHERM INDULTHERM-e

Circular Fire Damper Cartridge

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

Air distribution systems. Opticlean OC-Q...

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

ACCUBLOC high performance Heat Recovery

VL120. Multi blade smoke evacuation damper 120' C-NT-V24-A 01/2016

CONDOR. Supply air ceiling QUICK FACTS

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

Bevent Rasch BSKC6. - Fire /06/17

Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

Decentralised ventilation units

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Filter Technology from A to Z. Filter units and filter elements from TROX

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

Ceiling air diffuser INDULTHERM INDULTHERM-e

FIRE & SMOKE DAMPERS. Meeting tomorrow's requirements for fire and smoke protection today.

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Cleanroom systems. Supply air ceiling and recirculated air ceiling OP. for operating rooms with low-turbulence displacement flow

COOLflow 4E PRODUCT RANGE

Decentralised Ventilation Systems

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h

FEATURES AND BENEFITS

Orion-LØV LØV-R with Sirius

DUCT SYSTEMS CHAPTER 6

Fire protection unit

Orion-Opus LØV-R with Sirius

PDH & Professional Training

DUCT SYSTEMS CHAPTER 6

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

THE SMOKE MUST GO. Consulting - Project Planning - Supply - Installation - Service

Installation of a Brunner fireplace. General Indications

BSK-RPR Fire Damper. Additional operating instructions according to

Bevent Rasch RABC-VAV. - Fire /03/2018

Smoke extraction duct of sheet steel

Orion-PTV LØV-R with Sirius

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

Orion-LØV LØV-R with Sirius

FUME EXTRACT STRATEGY STATEMENT

Smoke Master SMIA Compact pressurisation and smoke exhaust system

Actionair. Hot/Shield PTC. BROCHURE UPDATED* High Operating Temperature Smoke Management and Fire Dampers

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

Technical data lumina PM

Schedule of Accreditation

BKA-EN Fire Damper. Additional operating instructions according to

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

TopMaster Air Handling unit. Technical data

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

TransShield ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance

Transcription:

Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES Small rectangular fire damper for the isolation of duct penetrations between fire compartments, available in many sizes Nominal sizes 200 100 to 800 200 mm Low differential pressure and sound power level Optional stainless steel casing or powder-coated casing for increased corrosion protection Can also be used as an air transfer damper or air transfer unit Integration into the central BMS with TROXNETCOM Universal installation options Optional equipment and accessories Electric actuator 24 V/230 V Release temperature 72/95 C Duct smoke detectors

APPLICATION Application Fire dampers of Type FKS-EU, with CE marking and declaration of performance, for the isolation of duct penetrations between fire compartments in the event of a fire To prevent the propagation of fire and smoke through ductwork to adjacent designated fire compartments Special characteristics Declaration of performance according to Construction Products Regulation Classification to EN 13501-3, up to EI 120 (v, h, i o) S Building inspectorate licence Z-56.4212-991 for fire resistance properties Complies with the requirements of EN 15650 Tested to EN 1366-2 for fire resistance properties Hygiene complies with VDI 6022 part 1 (07/2011), VDI 3803 (10/2002), DIN 1946 part 4 (12/2008), and EN 13779 (09/2007) Corrosion protection according to EN 15650 in connection with EN 60068-2-52 Closed blade air leakage to EN 1751, class 2 Casing air leakage to EN 1751, class C Low differential pressure and sound power level Any airflow direction Integration into the central BMS with TROXNETCOM e o Classification Class of performance to EN 13501-3, up to EI 120 (v, h, i o) S e o Nominal sizes B H: 200 100 800 200 mm (width in increments of 50 mm) L: 300 mm DESCRIPTION Variants With fusible link With spring return actuator

With cover grilles both ends as air transfer unit with general building inspectorate licence: Z-19.18-2127 With spring return actuator and duct smoke detector With spring return actuator, duct smoke detector and cover grilles on both ends for use as an air transfer opening, with general building inspectorate licence Z-6.50-2231 Parts and characteristics Easy dry mortarless installation into solid walls and ceiling slabs, lightweight partition walls, fire walls and shaft walls using an installation block Release temperature 72 C or 95 C (for use in warm air ventilation systems) Attachments Limit switch for damper blade position indication Spring return actuator for 24 V AC/DC or 230 V AC supply voltage Network module for the integration with AS-i or LON networks Spring return actuator and pre-wired duct smoke detector, 24 V or 230 V supply voltage Accessories Cover plate (to keep the fire damper stable and hence facilitate mortaring) Cover grille Flexible connectors Extension piece Rectangular installation block E Useful additions Duct smoke detector RM-O-3-D Duct smoke detector with airflow monitor RM-O-VS-D Construction features Rectangular or square construction, rigid casing, both flanges with fixing holes (System 30) Suitable for the connection of ducts, flexible connectors or a cover grille

The release mechanism is accessible and can be tested from the outside Two inspection access panels Intermediate dimensions in 50 mm increments for width Remote control with spring return actuator Materials and surfaces Casing: Galvanised sheet steel Galvanised sheet steel, powder-coated RAL 7001 Stainless steel 1.4301 Damper blade: Special insulation material Special insulation material with coating Other components: Damper blade shaft in stainless steel Plastic bearings Seals of elastomer The construction variants with stainless steel or powder-coated casing meet even more critical requirements for corrosion protection. Detailed listing on request. Standards and guidelines Construction Products Regulation EN 15650:2010 Ventilation for buildings Fire dampers EN 1366-2:1999 Fire resistance tests for service installations Fire dampers EN 13501-3:2010 Fire classification of construction products and building elements EN 1751:1999 Ventilation for buildings Air terminal devices Maintenance The functional reliability of the fire damper must be tested at least every six months;

this has to be arranged by the owner of the ventilation system; functional tests must be carried out in compliance with the basic maintenance principles stated in EN 13306 and DIN 31051. If two consecutive tests, one 6 months after the other, are successful, the next test can be conducted one year later. A functional test involves closing the damper blade and opening it again; with a spring return actuator this can be done via remote control Fire dampers must be included in the regular cleaning schedule of the ventilation system. For details on maintenance and inspection refer to the installation and operating manual TECHNICAL INFORMATION FUNCTION Construction with fusible link Functional description In the event of a fire, fire dampers shut automatically to prevent the propagation of fire and smoke through ductwork to adjacent designated fire compartments. In the event of a fire, the damper is triggered at 72 C or at 95 C (use in warm air ventilation systems) by a fusible link. The release mechanism is accessible and can be tested from the outside. Construction with spring return actuator Functional description The spring return actuator enables the motorised opening and closing of the damper blade; it can be activated by the central BMS. In the event of a fire, the damper is triggered thermoelectrically at 72 C or 95 C (use in warm air ventilation systems). As long as power is supplied to the actuator, the damper blade remains open. If the supply voltage fails, the damper closes (power off to close). Motorised fire dampers can be used to shut off ducts. The torque of each actuator is sufficient to open and close the damper blade even while the fan is running. The spring return actuator is fitted with limit switches that can be used for capturing the damper blade position. Schematic illustration of FKS-EU with fusible link

1 Casing 2 Inspection access 3 Fusible link 4 Damper blade with seal 5 Travel stop 6 Handle with interlock and damper blade position indicator 7 Release mechanism Schematic illustration of FKS-EU with spring return actuator

1 Casing 2 Inspection access 3 Temperature sensor 4 Damper blade with seal 5 Travel stop 6 Thermoelectric release mechanism 7 Spring return actuator Schematic illustration of the FKS-EU as air transfer unit, with fusible link and cover grille

1 Casing 2 Inspection access 3 Fusible link 4 Damper blade with seal 5 Travel stop 6 Handle with interlock and damper blade position indicator 7 Release mechanism 8 Cover grille 9 Extension piece Schematic illustration of FKS-EU as air transfer damper

1 Casing 2 Inspection access 3 Temperature sensor 4 Damper blade with seal 5 Travel stop 6 Thermoelectric release mechanism 7 Spring return actuator 8 Cover grille 9 Extension piece 10 Duct smoke detector RM-O-3-D

TECHNOLOGY Nominal sizes Casing length Volume flow rate range Differential pressure range 200 100 to 800 200 mm 300 mm Up to 1600 l/s or up to 5760 m³/h Up to 1500 Pa Operating temperature At least 0 50 C ** Release temperature Upstream velocity* 72 C or 95 C (for warm air ventilation systems) 8 m/s with standard construction; 10 m/s with spring return actuator * Data applies to uniform upstream and downstream conditions for the fire damper ** Temperatures may differ for units with attachments; details for other applications are available on request.

QUICK SIZING Volume flow rate V [m³/h] at differential pressure Δpst < 35 Pa H [mm] L WA [db(a)] B [mm] 200 300 400 500 600 700 800 100 125 150 160 200 35 300 480 660 840 1030 1230 1420 45 420 670 920 1180 1450 1720 2000 35 410 650 890 1150 1400 1700 1940 45 570 900 1250 1600 1960 2350 2700 35 520 830 1140 1470 1800 2140 2480 45 730 1160 1600 2060 2520 3000 3480 35 570 900 1250 1600 1970 2340 2700 45 790 1260 1750 2240 2750 3280 3800 35 760 1220 1690 2170 2660 3170 3680 45 1060 1700 2360 3040 3750 4430 5150 Volume flow rate V [l/s] at differential pressure Δpst < 35 Pa B [mm] H [mm] L WA [db(a)] 200 300 400 500 600 700 800 100 125 150 160 200 35 83 133 183 233 286 342 394 45 117 186 256 328 403 478 556 35 114 181 247 319 389 472 539 45 158 250 347 444 544 653 750 35 144 231 317 408 500 594 689 45 203 322 444 572 700 833 967 35 158 250 347 444 547 650 750 45 219 350 486 622 764 911 1056 35 211 339 469 603 739 881 1022 45 294 472 656 844 1042 1231 1431 SPECIFICATION TEXT

Rectangular or square fire dampers with flanges, for the isolation of duct penetrations between fire compartments. Tested for fire resistance properties to EN 1366-2, with CE marking and declaration of performance according to the Construction Products Regulation. Ready-for-operation unit, which includes a fire-resistant damper blade and a release mechanism. For mortar-based installation and dry mortarless installation into solid walls and ceiling slabs, lightweight partition walls and fire walls with cladding on both sides; also in shaft walls with metal support structure and cladding on one side. Casing length 300 mm, for the connection to ducts made of non-combustible or combustible materials. Thermal or thermoelectric release at 72 C or 95 C (warm air ventilation systems). Constructions with spring return actuator for opening and closing the fire damper independent of the nominal size and even while the ventilation system is running, e.g. for a functional test. Construction with installation block for easy dry mortarless installation. Special characteristics Declaration of performance according to Construction Products Regulation Classification to EN 13501-3, up to EI 120 (v, h, i o) S e o Building inspectorate licence Z-56.4212-991 for fire resistance properties Complies with the requirements of EN 15650 Tested to EN 1366-2 for fire resistance properties Hygiene complies with VDI 6022 part 1 (07/2011), VDI 3803 (10/2002), DIN 1946 part 4 (12/2008), and EN 13779 (09/2007) Corrosion protection according to EN 15650 in connection with EN 60068-2-52 Closed blade air leakage to EN 1751, class 2 Casing air leakage to EN 1751, class C Low differential pressure and sound power level Any airflow direction Integration into the central BMS with TROXNETCOM Materials and surfaces Casing: Galvanised sheet steel Galvanised sheet steel, powder-coated RAL 7001 Stainless steel 1.4301 Damper blade:

Special insulation material Special insulation material with coating Other components: Damper blade shaft in stainless steel Plastic bearings Seals of elastomer The construction variants with stainless steel or powder-coated casing meet even more critical requirements for corrosion protection. Detailed listing on request. Technical data Nominal sizes: 200 100 mm 800 200 mm Casing length: 300 mm Volume flow rate range: up to 1600 l/s or 5760 m³/h Differential pressure: up to 1500 Pa Operating temperature: at least 0 50 C ** Release temperature 72 C or 95 C (for use in warm air ventilation systems) Upstream velocity: 8 m/s with standard construction; 10 m/s * with actuator * Data applies to uniform upstream and downstream conditions for the fire damper ** Temperatures may differ for units with attachments; details for other applications are available on request. ORDER CODE Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-06-07 TROX GmbH

Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU Type FKS-EU Fire damper Accessories 1 No entry: none Construction No entry: standard construction 1 Powder-coated casing E B Installation block Cover plate Accessories 2 2 Stainless steel casing 7 Coated damper blade 1 7 Powder-coated casing and coated damper blade 2 7 Stainless steel casing and coated damper blade No entry: none A0 SS Attachments Z00 ZA12 W¹ With fusible link 95 C (only for use in warm air ventilation systems) Country of destination ¹ W can be combined with all constructions listed under, but not with attachments Z43RM Z45RM DE Germany Other destination countries upon request Nominal size [mm] B H L Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-06-07 TROX GmbH

Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU Type FKS-EU Fire damper Accessories 1 No entry: none Construction No entry: standard construction 1 Powder-coated casing, RAL 7001 2 Stainless steel casing 7 Coated damper blade B AA Cover plate Accessories 2 Cover grilles on both ends Attachments 1 7 Powder-coated casing, RAL 7001, and coated damper blade 2 7 Stainless steel casing and coated damper blade Z00 Z03 Country of destination DE Germany Other destination countries upon request Nominal size [mm] B H L Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-06-07 TROX GmbH

Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU Type FKS-EU Air transfer damper Accessories 1 No entry: none Construction No entry: standard construction 1 Powder-coated casing, RAL 7001 2 Stainless steel casing 7 Coated damper blade 1 7 Powder-coated casing, RAL 7001, and coated damper blade E B AA Installation block Cover plate Accessories 2 Cover grilles on both ends Attachments 2 7 Stainless steel casing and coated damper blade Z43RM Z45RM Country of destination DE Germany Other destination countries upon request Nominal size [mm] B H L TROX GmbH Online-Services Service-Hotlines Heinrich-Trox-Platz D-47504 Neukirchen-Vluyn Tel.: +49 (0)2845 202-0 Fax: +49 (0)2845 202-265 Order-Status (My TROX NET) TROX Academy Catalogue Download Your contact partner Online fault report BIM Sales Germany and technical consulting +49 (0)2845 202-0 Contact Technical service +49 (0)2845 202-400 Contact Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-06-07 TROX GmbH