Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Similar documents
STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Improvement of Temperatures Stratification caused by Air-conditioner. by means of Ceiling Fan in Classroom

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

power-saving period in summer, in which one of the indoor units was forced to change from a cooling mode to a fan mode, was introduced, and the effect

American Society of Heating, Refrigerating and Air-Conditioning Engineers

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

STUDY FOR SAFETY AT A RELATIVELY SHORT TUNNEL WHEN A TUNNEL FIRE OCCURRED

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

STUDY ON THE EFFECTIVENESS OF AIR-CONDITIONING AND VENTILATION SYSTEMS BY CFD ANALYSIS IN HOUSES

Comparison of Thermal Comfort by Radiant Heating and Convective Heating

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM

Numerical Simulation of Ventilation Efficiency in Commercial Kitchen

Optimized fan system design for the one-year cycle of a Heat Pump. Ziehl-Abegg SE Frieder Lörcher

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Analysis of Triangle Heating Technique using High Frequency Induction Heating in Forming Process of Steel Plate

Numerical Analysis of Water Temperature Distribution in the Tank of. ASHPWH with a Cylindrical Condenser

A Study of Drying Uniformity in a New Design of Tray Dryer

Heat Transfer in Evacuated Tubular Solar Collectors

Stock Vessels for Improved Quality and Energy Savings

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

Sandeep V. Lutade 1, Krunal Mudafale 2, Ranjan Kishore Mallick 3 1, 2

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

Aalborg Universitet. Diffuse Ceiling Inlet Systems and the Room Air Distribution Nielsen, Peter Vilhelm; Jensen, Rasmus Lund; Rong, Li

Design And Analysis Of Centrifugal Pump

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

[Eswaran, 3(3): March, 2014] ISSN: Impact Factor: 1.852

Development of Large Size Hybrid Fan

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Heat transfer and heating rate of food stuffs in commercial shop ovens

Study of air circulation inside the oven by computational fluid dynamics.

Vertical Distribution of Air Temperatures in Heated Dwelling Rooms

Compression of Fins pipe and simple Heat pipe Using CFD

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

The Experimental Validation of Numerical Modeling of the Air Distribution in the Indoor Ice Rink Arena

Experimental Study on Crawl-Space Heating with Thermal Storage using Heat Pump

HEAT REMOVAL TESTS FOR THE HIGH PERFORMANCE VAULT STORAGE SYSTEM OF SPENT NUCLEAR FUEL

Control of temperature and humidity surrounding the stone chamber of Takamatsuzuka tumulus during its dismantlement

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Using FDS Modelling to Establish Performance Criteria for Water Mist Systems on Very Large Fires in Tunnels

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

ICSV14. Cairns Australia 9-12 July, Noise reduction of handheld vacuum cleaners according to geometric optimization of air passages

Leakage of Mildly Flammable Refrigerants into a Room

AN ANALYSIS OF THE ACTUAL THERMAL PLUMES OF KITCHEN APPLIANCES DURING COOKING MODE

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Numerical Simulation of Thermal Comfort Degree in Radiant Floor Cooling Room. Architecture, Beijing , China

Impact of heat load distribution and strength on airflow pattern in rooms with exposed chilled beams

FREQUENCY ENHANCEMENT OF DUAL-JUNCTION THERMOCOUPLE PROBES

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

RESPONSE OF ANCHOR IN TWO-PHASE MATERIAL UNDER UPLIFT

AIRFLOW STUDY OF A SPILT-TYPE OUTDOOR UNIT SUBJECTED TO NEAR WALL EFFECT USING COMPUTATIONAL FLUID DYNAMIC (CFD) SIMULATION

EXPERIMENTAL STUDIES ON THE EFFECT OF THE FIRE POSITION ON PLUME ENTRAINMENT IN A LARGE SPACE

The Role of Computational Fluid Dynamic and Aeroacoustic Simulations in Reducing the Noise of a Forward-Curved Blade Radial Fan

A STUDY ON THE DEVELOPMENT OF A DEODORIZATION UNIT FOR THE TOILET BIDET

APPLICATION OF CFD SIMULATIONS FOR LOCATING OUTDOOR UNITS ON HIGH RISE TOWER Basant Kumar Gupta 1, Anand Patil 2

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

Numerical Analysis of the Bearing Capacity of Strip Footing Adjacent to Slope

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

CHAM Case Study Numerical Simulation of a Air-to-air Cross-flow Heat Exchanger

Numerical study of heat pipe application in heat recovery systems

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

An Experimental Study on Drying of Pistacia Terebinthus in a Fixed Bed Dryer

A Novel Approach for the Thermal Management. of PC Power Supply

Improving Single-Sided Room Ventilation by Using a Ceiling Fan

IMPLEMENTATION OF DISPLACEMENT VENTILATION SYSTEM BY USING A WALL-MOUNTED AIR CONDITIONER

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Finned Heat Sinks for Cooling Outdoor Electronics under Natural Convection

THE CONTROL METHOD OF THE INFLOW TURBU- LENCE INTERACTION NOISE FOR ROUTER COOLING FAN

Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics

NUMERICAL SIMULATION OF FIRE SPREAD IN TERMINAL 2 OF BELGRADE AIRPORT. PO Box 522, Belgrade, Serbia and Montenegro

Indoor Air of a Double-Storey Residential House in Malaysia

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Performance Study of Triple Concentric Pipe Heat Exchanger

EFFECT OF GEOMETRICAL CHANGES OF IMPELLER ON CENTRIFUGAL PUMP PERFORMANCE

Computerized Simulation of Automotive Air-Conditioning System: A Parametric Study

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Analysis of Pullout Resistance of Soil-Nailing in Lateritic Soil

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Thermo-Fluid Simulation Technique for Achieving Energy Saving in Open Showcases

An Experimental Study on Evacuated Tube Solar Collector for Heating of Air in India Avadhesh Yadav, V.K. Bajpai

Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products

Effect of the Use Pattern on Performance of Heat Pump Water Heater

AIRFLOW PATTERN AND PERFORMANCE ANALYSIS OF DIFFUSE CEILING VENTILATION IN AN OFFICE ROOM USING CFD STUDY

The Effect of Quantity of Salt on the Drying Characteristics of Fresh Noodles

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

CFD Analysis of Co-current Spray Dryer with Swirler at Air Inlet

A Method of Heat Exchange Structure Optimization of the Cricoid Plastic Parts

Investigations Of Chinese Cabbage Cold Storage Chamber Operation

Effects of Volute Tongue Clearance and Rotational Speed on Performance of Centrifugal Blower Nitin S. Jadhav *, S. R. Patil

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Transcription:

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room Y. Momoi 1, K. Sagara 1, T. Yamanaka 1 and H. Kotani 1 1 Osaka University, Graduate School of Eng., Dept. of Architectural Eng., 2-1 Yamadaoka, Suita, Osaka, Japan Email: momoi@arch.eng.osaka-u.ac.jp http://www.arch.eng.osaka-u.ac.jp/~labo4/ Summary: This study examines the way of utilizing a ceiling fan for airflow control in a large air-conditioned room. Although it seems that CFD simulation is useful in predicting the airflow around a ceiling fan, modeling of a ceiling fan as a body of rotation is very complicated. Therefore, in this study, airflow of a ceiling fan is modeled as boundary conditions of air velocity data measured near the ceiling fan. In this paper, the measured airflow pattern around a ceiling fan is compared with the CFD simulation result using the airflow model of the ceiling fan, in order to examine the validity of the airflow model. The CFD result was in good agreement with the measurement result concerning the average of air velocity. Keywords: Ceiling fan, CFD, Boundary condition, Measurement data, Large room Category: Modeling techniques 1. Introduction This study examines the way of utilizing a ceiling fan [1, 2, 3] in a large air-conditioned room for the dissolution of an indoor vertical temperature gradient in winter and the prevention of draft in summer. Although it seems that Computational Fluid Dynamics (CFD) simulation is useful in predicting the airflow around a ceiling fan, modeling of a ceiling fan as a body of rotation is very complicated. Since the number of divisions of the space increases, calculation load becomes heavy. As for complex-shaped supply openings, some techniques of modeling and decreasing calculation load are proposed by Nielsen [4]. In this study, these techniques will be applied to a ceiling fan, and airflow of a ceiling fan is modeled as the boundary conditions based on velocity data measured near the ceiling fan. In this paper, the measured airflow pattern around the ceiling fan is compared with the CFD simulation result using the airflow model of the ceiling fan, in order to examine the validity of the airflow model. 2. Airflow model of ceiling fan A ceiling fan (Matsushita Electric Industrial, F- M131H-W) used in this research is shown in Fig.1. In the CFD simulation of an indoor airflow induced by this ceiling fan, two virtual planes whose each side length is 14 cm are assumed at the position of 2cm above and below the ceiling fan. Measured values of air velocity and turbulent parameters near the ceiling fan are given as boundary conditions for airflow of the ceiling fan (Fig.2). The influence of a ceiling fan on an indoor airflow can be taken into consideration in the CFD simulation. It becomes unnecessary to simulate correctly the space between two planes where airflow is complicated in reality, and calculation load can be reduced. φ U, V, W, k, U, V, W, k, U, V, W, k, U, V, W, k, Fig.2 Schematic diagram of airflow model of ceiling fan φ Fig.1 Ceiling fan φ φ

3. Experimental set-up The experiments were carried out in the large experimental room. The iron framework with dimensions of 3.m x 1.5m x 3.m was constructed and the ceiling fan with a rotational radius of 65 cm was installed in the height of 2 m above the floor level (Fig.3). Measurement for 3 seconds was performed by 1Hz of sampling frequencies using the 3-dimensional ultrasonic anemometer (KAIJO, WA-59), and the average value of each air velocity component was calculated. Measurement for 2 seconds was carried out by 25Hz of sampling frequencies using hot-wire anemometer of constant temperature type (5µm tungsten, KANOMAX JAPAN, 251 R-T5), and turbulent kinetic energy k [m 2 /s 2 ] and energy dissipation of it [m 2 /s 3 ] were computed from the auto-correlation of measured air velocities. Measurement was performed at intervals of 5cm or 1cm. The measuring field was set between 8 cm above the ceiling fan and 12 cm below it, and horizontally up to 12 cm from the rotational center of the ceiling fan at each point of the cross section passing through the center of the ceiling fan (see Fig.4). The speed of rotation was fixed at 16 rpm. As the ceiling fan can generate either upward or downward flow depending on the rotational direction, the measurements were conducted under the two experimental conditions that airflow directions from the ceiling fan were upward and downward (Table 1). 4. Boundary Condition First, regression curves were obtained from the measured velocity data on the line (see Fig.5). Second, the boundary surface set at the position of 2cm above and below the ceiling fan was divided into the mesh of 1cm interval, and the values of air velocity components and turbulent parameters in the central point of each mesh were computed using the regression curves. Finally, the values given to a boundary surface were acquired by averaging them in 1cm mesh. The application section of a regression formula was divided considering the rotational radius (X=65cm) and the position where measured air velocity was the maximum value (upward: X=35cm, downward: X=45cm). All regression formulae were taken as a cubic function. In this way, the boundary conditions on the meshed plane of CFD simulation are determined. The boundary conditions under downward condition and upward condition are shown in Fig.6. Fig.3 Experimental equipment Fig.4 Measuring points Table 1 Experimental condition

2 Fig.5 Regression curves Fig.6 Boundary conditions 2

5. CFD simulation set-up As shown in Fig.7, CFD simulation of the airflow in experimental room was performed using the above-mentioned boundary condition for the ceiling fan based on measured value. The size of simulation space was determined by preliminary simulation. It is large enough to avoid the influence of a wall on the airflow near the ceiling fan. Fig.7 Simulation space Fig.8 Cross section around ceiling fan The cross section around the ceiling fan is shown in Fig.8. Beams were arranged with at intervals of 15cm. The airflow model of the ceiling fan was installed in the middle between two beams. On account of the restriction of simulation software, the boundary conditions of the blow-off and suction airflow of the ceiling fan could not be given on one surface respectively, but the same boundary conditions are given to the upper and lower sides of a box with a height of 5cm (the inside of the box was excluded from the simulation space). That is, for example under downward airflow condition, the blow-off surfaces were set at the position of 18cm (Z=-2cm) and 185cm (Z=-15cm) from the floor, and the suction surfaces were set at 215cm (Z=+15cm) and 22cm (Z=+2cm) from the floor. Although the iron framework was constructed around the ceiling fan in the experiment, it was not taken into consideration in the simulation since it appears that the framework does not affect the airflow near the ceiling fan. Simulation field was assumed to be isothermal so that temperature field was not analyzed. CFD simulations were carried out with the commercial CFD code (STREAM ver.5, Software Cradle co. Ltd. [5]). The standard k- two-equation turbulence model and SIMPLEC algorithm were applied with standard log-law wall function and finite-volume resolution. A computational grid was set up with 1cm interval. 6. Comparison between the measurement and CFD result 6.1 Air velocity distribution The measurement and CFD result of air velocity under downward condition and upward condition are shown in Fig.9. (1) Downward airflow condition In both measurement and CFD result, it is seen that the airflow goes toward the rotational center of the ceiling fan (X=cm) at Z=-2cm (blow-off side). Although the maximum downward air velocity is about 2m/s near X=45cm, air velocity falls suddenly outside it and becomes almost m/s outside the rotational radius of the ceiling fan (X=65cm). At Z=-4cm, -8cm, and -12cm in the measurement result, it turns out that the direction of blow-off airflow is changing outward gradually as it becomes far from a ceiling fan. There seems to be the influence of the floor at 2cm under the ceiling fan. However, in the CFD result, such a change of airflow direction observed in the measurement result can t be seen. The downward flow was struck on the floor and changed the upward flow near the rotational center in the measurement result. The upward airflow caused by rebounding of the downward flow was not observed at Z=-12cm near the rotational center in the CFD result. The insufficient grid division in the CFD field might cause this inconsistency. (2) Upward airflow condition In both measurement result and CFD result, in Z= 2cm (blow-off side), the maximum upward air velocity is about 1 m/s near X=45cm. Outward flow is observed as a whole. Outside X=65cm, air velocity was almost cm/s. At the height of Z= 4cm and 8cm, it turns out that the airflow blown by the ceiling fan has spread outside since the peak of air velocity distribution is moving outside while upward flow becomes weaker. In a suction side, the horizontal airflow changed into the perpendicular airflow as the airflow approaches the rotational center of the ceiling fan, and the airflow was sucked toward the blades of the ceiling fan. In the outer side of the ceiling fan, the horizontal suction flow that goes to the center of the ceiling fan can be seen. The influence of suction toward the ceiling fan becomes small as it becomes far from the ceiling fan. Concerning the suction flow of the ceiling fan, the CFD and measurement results are enough in agreement and it would be said that it is analyzable with sufficient accuracy.

Z [cm] 8 4 2-2 -4-8 -12 k [m2/s2].5.45.4.35.3.25.2.15.1.5 : Experiment (downward) [Z=-4cm] : CFD (downward) [Z=-4cm] 3 4 5 6 7 8 9 1 11 12 Fig.1 Turbulent kinetic energy distribution 1 2 : CFD (upward) [Z=4cm] : Experiment (upward) [Z=4cm] 1 m/s 1.4 8 Z [cm] 2 4 6 8 1 12 2 4 6 8 1 12 Experiment CFD Simulation (1) Downward airflow condition [m2/s3] 1.2 1..8.6.4 : Experiment (downward) [Z=-4cm] : CFD (downward) [Z=-4cm] : CFD (upward) [Z=4cm] : Experiment (upward) [Z=4cm] 4.2 2-2 -4-8.6.5 3 4 5 6 7 8 9 1 11 12 Fig.11 Dissipation rate of k distribution 1 2 : Experiment (downward) [Z=-4cm] -12 1 m/s 2 4 6 8 1 12 Experiment CFD Simulation (2) Upward airflow condition Fig.9 Air velocity distribution 6.2 Distribution of turbulent kinetic energy and its dissipation rate Turbulent kinetic energy can be calculated as follows: k = 1 2 3 2 u' 2 ( ) and its dissipation rate is given by: = C D k 3 2 l Turbulent length is expressed as follows: 2 4 6 8 1 12 1 l = C 4 D is integral length and obtained from the autocorrelation of measured air velocities: = u u'( t )u'( t+ ) d 2 u' ( t) l [m].4.3.2.1 3 4 5 6 7 8 9 1 11 12 Fig.12 Turbulent length distribution 1 2 : CFD (downward) [Z=-4cm] : Experiment (upward) [Z=4cm] : CFD (upward) [Z=4cm] The CFD and measurement results of turbulent kinetic energy distribution and its dissipation rate distribution are shown in Fig.1 and 11, respectively. The CFD result was compared with the measurement result in blow-off side (at Z=- 4cm under downward airflow condition and at Z=4cm under upward airflow condition). In the measurement result, they have tendency to become large significantly at X=5cm to 55cm. On the other hand, although the maximum values in the CFD result have appeared in the almost same position as those in the measured result, they are smaller than the measured values. Since boundary conditions are equalized among the width of a mesh

(1cm), it is considered that non-uniform distribution like the measurement result is not observed in the CFD result. In the other positions, the values in the CFD result are larger than those in the measurement result. As a cause, the production of turbulent kinetic energy due to air velocity distribution may have been estimated too greatly. Furthermore, since turbulent kinetic energy and its dissipation rate distribution of the CFD simulation differ from those of the measurement in this way, it is thought that the difference would induce air velocity distribution near the rotational center of the ceiling fan. 6.3 Turbulent length distribution The CFD and measurement results of turbulent length distribution are shown in fig.12. Turbulent length is compared in blow-off side in the same way as turbulent kinetic energy and its dissipation rate. In the measurement result, it shows the maximum value at X= 25cm to 35cm. On the other hand, in the CFD result, its value is smaller than the measured value as a whole, and it becomes large in the distant position from the rotational center of the ceiling fan. 7. Conclusions Air velocity near a ceiling fan was measured. Then the CFD simulations of the experimented space were performed using the boundary conditions of the ceiling fan based on air velocity measurement, and validity of the boundary conditions was examined by comparing the measurement result with the CFD result. The conclusions can be drawn as follows: The floor affects the airflow pattern greatly in the distant position from the ceiling fan. The measurement value and the CFD value were in good agreement about the suction airflow. Under the downward condition, air velocity near the rotational center of the ceiling fan in the CFD result was larger than that in the measurement result. As a cause, it is possible that large distribution resulting from the rotational cycle of the ceiling fan is also included in turbulent parameters given as boundary conditions and that the division interval of space is not fully fine. In order to account for the influence of the division interval of space, CFD simulations with fine division are required. It may not be appropriate to input the value computed from the measurement result into CFD simulation as it is, and then the further examination is required about turbulent parameters given to the boundary conditions of the ceiling fan. Moreover, the size and position of the boundary surface should be examined, too. More research would be needed to investigate the effect of the size of the computational grid and the turbulence parameters on the accuracy of the simulation with this airflow model. Acknowledgements The authors would like to thank Machiko Kuise for her help in carrying out the measurements and CFD simulations. The provision of the ceiling fan from Matsushita Ecology System Co., Ltd. is gratefully acknowledged. Nomenclature k u' 2 C D l u = turbulent kinetic energy [m 2 /s 2 ] = mean-square fluctuating component of velocity [m 2 /s 2 ] = dissipation rate of turbulent kinetic energy [m 2 /s 3 ] = constant (.9) = turbulent length [m] = integral length [m] = mean velocity [m/s] References [1] F. H. Rohles, S. A. Konz and B. W. Jones. Ceiling Fans as Extenders of the Summer Comfort Envelope. ASHRAE Transactions, Vol.89 (1983), Part 1A, pp.245-262 [2] S. Chandra. Fans to Reduce Cooling Costs in the Southeast. Florida Solar Energy Centre FSEC- EN-13-85, Cape Canaveral, FL, 1985 [3] R. Aynsley. Fan Size and Energy Efficiency. International Journal of Ventilation, Volume 1 Number1, 22 [4] P.V. Nielsen. Description of Supply Openings in Numerical Models for Room Air Distribution. ASHRAE Transactions (1992): symposia. [5] STREAM ver.5, Software Cradle co. Ltd. http://www.cradle.co.jp/eindex.htm