ECHOLINE LOW PRESSURE MONITOR. Prevents Unwanted Shutdown Time and Space Saving UL Recognized

Similar documents
Vanguard. Toxic & combustible gas detector

ue short form catalog Leaders in Safety, Alarm & Shutdown

180 Dexter Ave, P.O. Box 9143 Watertown, MA USA Phone: Fax: CP031210K

CO2 Sensor User and Installation Guide

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Controllers. Instruction Manual WARNING

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Instruction Manual WARNING

ion Genesis Pump Controller

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

External Wireless Sounder

Remote Relay Module (RRM)

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

ACL TC 200 TEMPERATURE CONTROLLER

Analog Room Pressure Monitor RPC Series

Installation and Operations Manual

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

short form catalog SFC 08

LMA LINE MONITOR ALERT USER S MANUAL

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

Desiccant / Pump Dehumidification System. Model Operating Manual

EQUIPMENT Operation Manual

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

SEC Signature Process Gas Analyzer

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

NT DUAL CHANNEL DISPLAY. User Guide

Duct Mount. Installation Instructions

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

CO Guardian LLC Document No E. AIRPORT DRIVE Date: TUCSON, AZ CO Guardian LLC 1951 E. Airport Dr.

Original instructions Sense7-series Non-contact coded safety switch

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

OM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.

OWNERS MANUAL MODEL 451 (-101 & -201)

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

Oxygen (O2) Single-Point Gas Detection System

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS TALKBACK MODULE

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

INSTRUCTION MANUAL P Heating and 1 Cooling

Long Range Radio Alarm Transmitter

esense CO2 Transmitter and Alarm

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

External Wireless Sounder

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

EQUIPMENT Operation Manual

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance...

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

Document No

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

Figure 1 DirectLine DL423 Sensor. Description, continued

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Active Infrared Multi Beam Sensors

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

WITH OMRON E5CC CONTROL

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

Mini. Level Control systems For Manual Sump Pumps up to 750W 1 or 2 Pump Systems

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

INSTALLATION INSTRUCTIONS

Active Infrared Multi Beam Sensors. R Series

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

FUME HOOD MONITOR ALNOR AIRGARD 200

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

XT Series Thermostats

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

OPERATION & INSTALLATION MANUAL

Air Pump Up to 800 gallons

AS570 Chill-Out Combination Sensor Installation and Operating Instructions

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Preamplifier Power Supply PPS-02 user's guide

Corrosion Resistant Fluid and Air Handling Systems.

installation & operation manual

MaxLite LED MICRO-T PANEL

Interrupted Ignition Series Oil Primary Control

Next Generation Corona Discharge Auto Voltage Sensing Installation Manual

Static Pressure Control

IN020 Rev F Page 1 of 8

SEC 2000 Millenium Infrared Gas Detector

Chargebuster Ion Gun Installation, Operation and Maintenance

COOPER POWER SERIES. CT Protector Retrofit Kit. Voltage Regulators MN225057EN. Effective March 2017 Supersedes March 2010 (S )

EQUIPMENT Operation Manual

Transcription:

ECHOLINE LOW PRESSURE MONITOR Prevents Unwanted Shutdown Time and Space Saving UL Recognized P R E C I S I O N S E N S O R S

ECHOLINE overview ECHOLINE was designed in cooperation with a leading semiconductor manufacturer to prevent costly system shutdowns and reduce maintenance costs associated with low pressure monitoring of gas cabinet exhaust systems. ECHOLINE s Maintenance Mode feature prevents false alarms during system maintenance and balancing. A customer defined time delay prevents false trips which can cause system shutdowns. ECHO (Electronic Circuit Health Output) diagnostics alert the user to loss of external power or internal electronics failure. Four ECHOLINE units fit into the space of one old-fashioned gauge/switch. Four LDP switches will fit in the same space as one older gauge/switch features LED display of process and alarm state Alarm status indicator Independently adjusted front panel zero adjustment Independentlyset low and high set points Conformance to S2-0200 and CE, complies with the requirements of UL 991 Latching relay output with adjustable time delay Maintenance Mode to prevent false trips during ventilation system balancing LED status indication Applications STATIC PRESSURE APPLICATION Gas Cylinder Cabinets Gas Isolation Box (GIB) Mini Environments Wet Bench & Wet Station Chemical Dispensing Diffusion Furnace Scavenger Cleaning Hoods Glove Boxes Pump & Equipment Exhaust Supplemental Exhaust ECHOLINE FULL SCALE RANGES 1 to 5 WC 1 to 5 WC 0.2 WC 1 to 5 WC 1 to 5 WC Self-diagnostics Optional 4-20 ma output Terminal block wiring 12 to 24 VDC power Adjustable time delay to eliminate false trips and unwanted system shut down Front cover cleanroom image courtesy of Pentagon Technologies. 2 U N I T E D E L E C T R I C C O N T R O L S

SEMI S2-0200 SAFETY CONSIDERATIONS ECHOLINE was created using widely accepted best practices in an ISO 9001/AS 9000 quality environment. Components used in the design and production of ECHOLINE have been selected for their time proven performance, availability and reliability. ECHOLINE contains no moving parts that can wear out, or microprocessors that are susceptible to hidden software problems. When Used To Provide Safety Interlock, Monitor Ventilation Or Optimize Exhaust, ECHOLINE Features: Discrete all analog electronic components - no microprocessor Self-monitoring "ECHO" diagnostics Complies with the requirements of UL 991 Fault tolerant design Maintenance mode User selected time delay Convenient interfacing with facility alarm system When Used To Monitor Non- Critical Ventilation, ECHOLINE Features: Maintenance mode to prevent false trips during ventilation system balancing Optional non-latching relay Bright LED display of process pressure Operation High and low limit alarms are independently set from the front panel. In normal operation, the LED display will indicate the sensed pressure and the High Limit/Low Limit LED status indicators will be green. When a preset limit is exceeded, the LED signals an alarm condition by turning red. After a customer selected time delay, the electromechanical relay contacts will be latched open and the LED display will flash the process pressure once every second. Manually depressing the reset button will cause the relay contacts to close if and when the process pressure is within set limits. Maintenance Mode The "Maintenance Mode" option is a unique and convenient safety feature which allows the user to widen the alarm set points during system maintenance. By closing terminal circuits 3 and 4, using a key switch or password protected computer, the user can expand the limits to 5% and 90% of the range to continue monitoring and prevent false trips. Opening terminal circuits 3 and 4 immediately returns the set points to the previous settings. Time Delay ECHOLINE includes an adjustable "stand alone" time delay to prevent intermittent tripping due to brief transient upsets. When the unit senses a pressure outside the limits, the status LED will immediately turn red, but the relay will not open for a pre-selected time delay. The time delay will reset to zero if the process pressure returns to within the limits during the transient conditions. This feature provides a degree of "fault tolerance" for exhaust flow interlock uses. The time delay is field settable through a jumper located on the rear of the enclosure for 1, 10, 20 or 30 seconds. ECHO Diagnostics The ECHO function is an internal electronic check of certain circuit parameters. In the event of an internal failure, the ECHO output relay immediately opens to communicate the fault condition and the unit display goes blank. The electromechanical output relay has isolated contacts that monitor the circuit in real time. U N I T E D E L E C T R I C C O N T R O L S 3

ECHOLINE specifications INDICATING PRESSURE RANGES DISPLAY ALARM SET POINT RANGE RESET CALIBRATION ACCURACY SWITCH AND ECHO OUTPUTS RELAY RATING STATUS LEDS TIME DELAY ANALOG OUTPUT (OPTIONAL) OVERPRESSURE PRESSURE CONNECTION MEDIA 0.2 to 10 WC (see model chart) 3 digit, 0.30 high red LED Independently set high and low limits, 5 to 90% of indicating range Alarm condition will remain until front panel reset button is pressed, and pressure is within limits Field adjustable zero via front panel screw adjustment 1% of range @ 20 C Electro-mechanical relay, SPDT, Form A Dry Contacts 1.0A @ 30 VDC, resistive Green in normal state, red in alarm state 1, 10, 20, 30 seconds. Factory set at 10 seconds. Changeable via rear panel jumper. 4-20 ma, non-isolated, current sinking. Maintenance Mode feature disabled. ± 14.5 psi (1 WC and above), ± 80 WC (under 1 WC) Push-to-connect fitting(s) for 0.25 O.D. tubing or dual barbed fitting for 0.170" I.D. hose Dry air, or inert non-conductive gas OPERATING AMBIENT TEMPERATURE 0 to 40 C ENCLOSURE WIRING WEIGHT POWER 1/16 th DIN 43700, panel mounted polycarbonate, plastic Plugable terminal block, 18-26 AWG 7 oz (200 g) maximum 12-24 VDC, 1.4 Watts 4 U N I T E D E L E C T R I C C O N T R O L S

approvals Conformance to S2-0200 SEMI standards EN61326-1:1997 Electromagnetic compatibility UL Recognized Component, Complies with the requirements of UL 991 Model Range / Units* Minimum Set Pressure Proof Pressure Burst Pressure LDP0.2 WC 0.2 x 0.001" WC.002 WC ± 80 WC 7 psig LDP0.5 WC 0-0.5 x 0.001" WC 0.03 WC ± 80 WC 7 psig LDP1 WC 0-1" x 0.01 WC 0.05 WC ± 14.5 psig 20 psig LDP2 WC 0-2" x 0.01 WC 0.10 WC ± 14.5 psig 20 psig LDP5 WC 0-5" x 0.01 WC 0.3 WC ± 14.5 psig 20 psig LDP10 WC 0-10 x 0.1 WC 0.5 WC ± 14.5 psig 20 psig LDP20 WC 0-20 x 0.1 WC 1.0 WC ± 14.5 psig 20 psig LDP50 P 0-50 Pascal x 0.1 Pascal 3 Pa ± 80 WC 7 psig LDP100 P 0-100 Pascal x 1 Pascal 5 Pa ± 14.5 psig 20 psig LDP500 P 0-500 Pascal x 1 Pascal 25 Pa ± 14.5 psig 20 psig LDP1000 P 0-1000 Pascal x 1 Pascal 50 Pa ± 14.5 psig 20 psig LDP2000 P 0-1999 Pascal x 1 Pascal 100 Pa ± 14.5 psig 20 psig * For user selectable scale ( WC to Pa) consult factory

ECHOLINE how to order Create a part number by using the system below. The part number will follow this form: LDP 1WC N M C M05 Type Setting Pressure Standard Accessory Options Range Connection Feature LDP 1WC N M C M05 TYPE CODE LDP DESCRIPTION Low Differential Pressure SETTING RANGE Inches of Water Column 0.2WC 0-0.2" WC 0.5WC 0-0.5" WC 1WC 0-1" WC 2WC 0-2" WC 5WC 0-5" WC 10WC 0-10" WC 20WC 0-20" WC Pascal 50P 0-50 Pascal 100P 0-100 Pascal 500P 0-500 Pascal 1000P 0-1000 Pascal 2000P 0-1999 Pascal PRESSURE CONNECTION N P D Single push-to-connect for Negative Pressure Single push-to-connect for Positive Pressure Dual barbed tube for Differential Pressure STANDARD FEATURES (only one can be selected) M Maintenance Mode A 4-20 ma Analog Output ACCESSORY C Clear watertight cover (when ordering separately, specify p/n 9728) P Retrofit mounting plate (when ordering separately, specify p/n 9729) OPTIONS M01 M02 M05 Non-latching arm 6mm Metric push-to-connect fitting D Sub connector (9 pin) The specified example denotes a 0 to 1" WC ECHOLINE with a single negative pressure port, maintenance mode option, watertight cover and D Sub connector. 6 U N I T E D E L E C T R I C C O N T R O L S

dimensional drawings U N I T E D E L E C T R I C C O N T R O L S 7

specifications INDICATING PRESSURE RANGES DISPLAY ALARM SET POINT RANGE RESET CALIBRATION ACCURACY SWITCH AND ECHO OUTPUTS RELAY RATING STATUS LEDS TIME DELAY ANALOG OUTPUT (OPTIONAL) OVERPRESSURE PRESSURE CONNECTION MEDIA 0.2 to 10 WC (see model chart) 3 digit, 0.30 high red LED Independently set high and low limits, 5 to 90% of indicating range Alarm condition will remain until front panel reset button is pressed, and pressure is within limits Field adjustable zero via front panel screw adjustment 1% of range @ 20 C Electro-mechanical relay, SPDT, Form A Dry Contacts 1.0A @ 30 VDC, resistive Green in normal state, red in alarm state 1, 10, 20, 30 seconds. Factory set at 10 seconds. Changeable via rear panel jumper. 4-20 ma, non-isolated, current sinking. Maintenance Mode feature disabled. ± 14.5 psi (1 WC and above), ± 80 WC (under 1 WC) Push-to-connect fitting(s) for 0.25 O.D. tubing or dual barbed fitting for 0.170" I.D. hose Dry air, or inert non-conductive gas OPERATING AMBIENT TEMPERATURE 0 to 40 C ENCLOSURE WIRING WEIGHT POWER 1/16 th DIN 43700, panel mounted polycarbonate, plastic Plugable terminal block, 18-26 AWG 7 oz (200 g) maximum 12-24 VDC, 1.4 Watts United Electric Controls 37 Meadowood Drive Larkspur, CA 94939 Phone: 415-924-5801 Fax: 415-924-5802 E-mail: rreis@ueonline.com

RECOMMENDED PRACTICES AND WARNINGS United Electric Controls Company recommends careful consideration of the following factors when specifying and installing UE pressure and temperature units. Before installing a unit, the Installation and Maintenance instructions provided with unit must be read and understood. To avoid damaging unit, proof pressure and maximum temperature limits stated in literature and on nameplates must never be exceeded, even by surges in the system. Operation of the unit up to maximum temperature is acceptable on a limited basis (i.e., start-up, testing) but continuous operation must be restricted to the designated adjustable range. Excessive cycling at maximum temperature limits could reduce sensor life. A back-up unit is necessary for applications where damage to a primary unit could endanger life, limb or property. A high or low limit switch is necessary for applications where a dangerous runaway condition could result. The adjustable range must be selected so that incorrect, inadvertent or malicious setting at any range point cannot result in an unsafe system condition. Install unit where shock, vibration and ambient temperature fluctuations will not damage unit or affect operation. Orient unit so that moisture does not enter the enclosure via the electrical connection. When appropriate, this entry point should be sealed to prevent moisture entry. Unit must not be altered or modified after shipment. Consult UE if modification is necessary. Monitor operation to observe warning signs of possible damage to unit, such as drift in set point or faulty display. Check unit immediately. Preventative maintenance and periodic testing is necessary for critical applications where damage could endanger property or personnel. For all applications, a factory set unit should be tested before use. Electrical ratings stated in literature and on nameplate must not be exceeded. Overload on a switch can cause damage, even on the first cycle. Wire unit according to local and national electrical codes, using wire size recommended in installation sheet. Do not mount unit in ambient temp. exceeding published limits. LIMITED WARRANTY OF REPAIR AND REPLACEMENT Seller warrants that the product hereby purchased is, upon delivery, free from defects in material and workmanship and that any such product which is found to be defective in such workmanship or material will be repaired or replaced by Seller (F.O.B. UE Milford); provided, however, that this warranty applies only to equipment found to be so defective within a period of 36 months from the date of manufacture by the Seller. Seller shall not be obligated under this warranty for alleged defects which examination discloses are due to tampering, misuse, neglect, improper storage, and in any case where products are disassembled by anyone other than authorized Seller s representatives. EXCEPT FOR THE LIMITED WARRANTY OF REPAIR AND REPLACEMENT STATED ABOVE, SELLER DISCLAIMS ALL WARRANTIES WHATSOEVER WITH RESPECT TO THE PRODUCT, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. U.S. SALES OFFICES United Electric Controls 12630 Summerwood Glen Houston, TX 77041 Phone: 832-243-0119 Fax: 832-243-0140 E-mail: rhooker@ueonline.com United Electric Controls 37 Meadowood Drive Larkspur, CA 94939 Phone: 415-924-5801 Fax: 415-924-5802 E-mail: rreis@ueonline.com INTERNATIONAL OFFICES AUSTRALIA United Electric Controls, (Aust) PTY Ltd. 615 Warrigal Rd. (Locked Bag 600) Ashburton, Victoria 3147, Australia Phone: 613-9567-0750 Fax: 613-9567-0755 BELGIUM United Electric Controls, Europe G. Van Gervenstraat 19A B-9120 Beveren-Waas, Belgium Phone: 32-3-755 43 83 Fax: 32-3-755 27 47 CANADA United Electric Controls, Canada Ltd. 5320 Bradco Blvd. Mississauga, Ontario L4W 1G7, Canada Phone: 905-625-5082 Fax: 905-625-5709 GERMANY United Electric Controls, Europe An Der Zentlinde 21 D-64711 Erbach, Germany Phone: 49-6062-7400 Fax: 49-6062-7501 INDIA United Electric Controls, India Amar Hill, Saki, Vihar Road Powai, Mumbai 400 072, India Phone: 91-22-857-6921 Fax: 91-22-857-1707 MALAYSIA United Electric Controls, Far East No. 1-2-2, 2nd Floor Jalan 4/101C Cheras Business Centre Batu 5, Jalan Cheras 56100 Kuala Lumpur, Malaysia Phone: 603-933 4122 Fax: 603-933 4155 LIABILITY LIMITATION SELLER S LIABILITY TO BUYER FOR ANY LOSS OR CLAIM, INCLUDING LIABILITY INCURRED IN CONNECTION WITH (I) BREACH OF ANY WARRANTY WHATSOEVER EXPRESSED OR IMPLIED, (II) A BREACH OF CONTRACT, (III) A NEGLIGENT ACT OR ACTS (OR NEGLIGENT FAILURE TO ACT) COMMITTED BY SELLER, OR (IV) AN ACT FOR WHICH STRICT LIABILITY WILL BE IMPUTED TO SELLER, IS LIMITED TO THE LIMITED WARRANTY OF REPAIR AND REPLACEMENT STATED HEREIN. IN NO EVENT SHALL THE SELLER BE LIABLE FOR ANY SPECIAL, INDIRECT, CONSEQUENTIAL OR OTHER DAMAGES OF A LIKE GENERAL NATURE, INCLUDING, WITHOUT LIMITATION, LOSS OF PROFITS OR PRODUCTION, OR LOSS OR EXPENSES OF ANY NATURE INCURRED BY THE BUYER OR ANY THIRD PARTY. ECHOLINE02 UNITED ELECTRIC CONTROLS Precision Sensors Division 50 Seemans Lane Milford, CT 06460 USA Telephone: 203 877 2795 Fax: 203 877 8752 Email: sales@precisionsensors.com www.precisionsensors.com BHA2K0702