InfinityLab Quick-Connect Bio-inert Heat Exchanger

Similar documents
Agilent InfinityLab Online SPE Solution

Agilent 1290 Infinity II Online SPE Solution

Wide-Bore Heat Exchanger Installation Kit ( )

Customers should provide all necessary operating supplies upon request of the engineer.

Installing the 30-cm Column Heater/Cooler

Installation of Hotel Drawers

ACQUITY UPLC HT Column Heater Instructions

Mariner Microspray and Low-Flow Electrospray Fused Silica Spray Tip and Capillary Kit. Operating Instructions. 1 Product Description.

The Complete and Easy Guide to Configuring Your Specific Thermo NanoLC for Mass Spec Analysis

An Advanced Heat Exchanger for the Agilent 1290 Infinity Thermostatted Column Compartment

Agilent 1100 Series Refractive Index Detector. Reference Manual

High Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity

DRAIN WATER TEMPERING INSTALL

Agilent 1260 Infinity Multi-Detector Suite

ACQUITY UPLC H-Class Column Compartments Operator s Overview and Maintenance Information

Eldex Column Heater. Operator s Manual

Installing a Fast Oven Upgrade Kit

CryoFit. Handling of Flow Cell and Capillaries. User Guide. Version 002

Agilent 1100 Series Autosampler Thermostat Reference Manual

Platen Heater Pad Replacement

Agilent 1100 Series Variable Wavelength Detector. Reference Manual

MODEL SK2750. COMPRESSOR SERVICE KIT For use on 2750 Series Compressors

Agilent 1290 Infinity Thermostat

General Animal Injections

Tool-free LC connections for HPLC, UHPLC and nano LC systems

Installation Instructions

Enhancing Throughput of Online SPE Analysis of Pesticides in Wastewater The Agilent 1200 Infi nity Series Online SPE Solution

WARNING. Failure to install this kit within the guidelines might adversely affect safety, performance, component life and warranty coverage.

Rapid Quantification of Polar and Semipolar Pesticide Metabolites with Combined Online SPE and Direct Injection

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1

TECHNICAL INSTRUCTIONS

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

Thermo Scientific. TRACE GC Ultra. Gas Chromatograph Maintenance and Troubleshooting Manual. PN , Revision March 2011

ACQUITY UPLC H-Class Sample Manager - Flow Through Needle Operator s Overview and Maintenance Information

Installation Manual Mopar Engine Compartment Upgrade Kit

WARNING DESCRIPTION PART NUMBER QTY PLUMBING, DYNATEMP DRAIN QUENCH BRACKET, THERMOSTAT DRAIN QUENCH

Installation Instructions

Bunch Length Interferometer System

Agilent 1200 Series Variable Wavelength Detector

A B A B4

Agilent 1290 Infinity II Vialsampler Data Sheet

3. DISCONNECT AIR CONDITIONING TUBE ASSY SST HINT: Disconnect in the same way as the cooler refrigerant suction hose No.1.

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST PLYMOUTH BELVEDERE

Preparing the 6850 Series II GC for 597x MSD Installation

SERVICE BULLETIN A

MODEL COMPRESSOR SERVICE KIT For use on Midmark Power Air Oil-less Compressor Models P21, P22 & P32

General System Layout Sketch

1 of 5 6/28/17, 1:54 PM

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET NOVA

Agilent 8355 Sulfur and 8255 Nitrogen Chemiluminescence Detectors

STOP! Read this notice. STOP! Read before proceeding. These instructions are for gas conversion of the Evergreen boiler only.

FPD - Flame Photometric Detector

Service Bulletin

Nafion Dryer. Installation Manual QUI Version 1.4. October 2013

SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve

Universal NanoFlow Sprayer Installation and Maintenance Guide

NMR SAMPLING ACCESSORIES CLEANING NMR SAMPLE TUBES

SRI 8610C GC for PCB in Transformer Oil Analysis November 2014

Installation Instructions

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Industrial Sewing Machine TECHNICAL MANUAL SEWING MACHINE HEAD. Electronic Pattern Sewing Machine. Model PLK-G1010 A180E593P03

Replacing a Gun Thermostat

Agilent 1200 Infinity Series ELSD

Optimizing the Performance of the Agilent 1290 Infinity Evaporative Light Scattering Detector

Nexera-i Specifications Prominence-i Specifications

Agilent 1200 Series Diode Array and Multiple Wavelength Detectors

22 The Flame Ionization Detector

Industrial Sewing Machine TECHICAL MANUAL SEWING MACHINE HEAD. Electronic Pattern Sewing Machine. Model PLK-G1010 A180E593P02

TCD-to-FID Series Connection on a 6820 GC, Accessory G4319A

HISTORY OF VARIAN CAPILLARY INJECTORS

930 Compact IC Flex. 930 Compact IC Flex Oven SeS/PP/Deg. Manual Short Instructions EN /

MODEL SK2660 COMPRESSOR SERVICE KIT. For use on 2660 and 2680 Model Compressors

MODEL SK2660 COMPRESSOR SERVICE KIT. For use on 2660 and 2680 Model Compressors

SYSTEM CONTROL KIT. Model: CK-62. Designed for use on SWG Series Power Vent Hoods for controlling oil fired heating appliances with 120 VAC controls.

Mitocell: Instructions for Use

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1968 CHEVROLET IMPALA

Agilent 6400 Series. Maintenance Guide. Agilent Technologies

High Temperature High Pressure Cell User Manual

Installation Instruction. Puritan Bennett. Wall Air Water Trap For 800 Series Ventilator Basic Cart. Pla

Agilent 1200 Infinity Series ELSD

Multi-Mode Electrode pro

Operating Instructions

INVERTER SPLIT - TYPE

PAVIA INSTALLATION GUIDE

DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS

AAO100 Dosing pump. Measurement made easy. Introduction

Installation Instructions

Thermal Stability Systems

V Refrigeration Module

INSIDE ENGINE COMPARTMENT TOYOTA AIR CONDITIONING ENGLISH EUROPE

Audi-Larm Audible Alarm

USER MANUAL UN-200V / UN-200VH

INSTALLATION INSTRUCTIONS

Installation. Leveling

GE Healthcare. Mixer M-925. Instructions

Refrigerated Cooling System

Installation Instructions

Air Server & Multi Channel Samplers (MCS06 & MCS08)

Industrial Sewing Machine TECHNICAL MANUAL SEWING MACHINE HEAD. Electronic Pattern Sewing Machine. Model PLK-G2516 A180E621P01

Heat Exchanger Block Replacement Instructions

Transcription:

InfinityLab Quick-Connect Bio-inert Heat Exchanger Installation in an Agilent 1260 Infinity II MCT This technical note describes the installation of Bio-inert Heat Exchangers to an Agilent 1260 Infinity II MCT. Contents Installation 2 Installing UHP Fittings 5 Installation of stainless steel cladded PEEK capillaries to Soft Connectors 9 Installation of the Bio-inert Zero Dead Volume (ZDV) Union 11 Agilent Technologies

Installation Tools required p/n Description 5043-0915 Fitting mounting tool for bio-inert capillaries 8710-0510 Wrench open 1/4 5/16 inch 5023-2502 Hex driver SW-6.35, slitted Parts required p/n Description G5667-81005 Capillary PK/ST 0.17 mm x 500 mm RLO/RLO (bio-inert) * 5067-4780 Capillary 300 ID 0.17 w/socket OD 1.6 BIO G7116-60041 Quick-Connect Heat Exchanger Bio-inert 5067-5403 UHP fitting 5067-4741 ZDV union (Bio-inert) G7116-68003 Column Holder Clips (2/Pk) * supplied with the G5668-68705 Accessory Kit Bio-inert Multisampler supplied with the G7116-68715 Accessory Kit 1260 MCT Bio 2

1 Connect the 500 mm capillary (G5667-81005) to port 6 of the Multisampler using a removable fitting (5067-5403), see Installing UHP Fittings on page 5. 2 Connect the Bio-inert ZDV (5067-4741) to the capillary using a removable fitting (5067-5403), see Installation of stainless steel cladded PEEK capillaries to Soft Connectors on page 9. 3 Connect the short part of the Quick-Connect Heat Exchanger Bio-inert (G7116-60041) to the ZDV using a removable fitting (5067-5403). 3

4 Attach the Heat Exchanger to the MCT and fix it with the Hex driver (5023-2502). 5 Attach the Column Holder to the MCT. 6 Connect a column to the long heat exchanger capillary using either a removable fitting (5067-5403) or a Quick Connect Fitting (not included) (1.). Connect the outlet of the column to the detector using the 300 mm capillary (5067-4780) and finger tight PEEK Fittings (2.). Clip the column into the column holder (3.). 4

Installing UHP Fittings Tools required p/n Description 5043-0915 Fitting mounting tool for bio-inert capillaries Parts required p/n Description Capillaries For details refer to the part section of the manual. and Fittings 1 Slide the fitting on the capillary. Let the capillary jut out 5 mm. 5

2 Insert the fitting to the receiving port and push the capillary to the bottom of the port. 3 Finger tighten the nut into the port until snug. 6

4 Use Fitting mounting tool (5043-0915) or a 5 mm hex wrench for fixing the fitting (maximum torque 0.8 Nm). CAUTION Potential damage of capillaries Do not remove fittings from used capillaries. 7

5 When using UHP-FF fittings with bioinert capillaries, do not try to remove fittings from these capillaries. Bio-inert capillaries are using a PEEK front end, which may expand under pressure especially when being in contact with some organic solvents. If a fitting is moved across an expanded PEEK end, there is a risk of damaging the capillary by ripping off its end. Before re-installing such capillaries, push the ferrule towards the rear site for a small distance. Figure 1 Capillary fitting 8

Installation of stainless steel cladded PEEK capillaries to Soft Connectors Use this procedure for soft connectors, which are typically made from PEEK. These are the following connections: to and from all bio-inert valves (injection valve in the autosampler and valves in the thermostatted column compartment and 1290 Infinity Valve Drive), bio-inert ZDV unions (detector flow cells, multi-draw upgrade kit, capillary to capillary connections, for example, for heat exchangers), to the autosampler needle and to PEEK columns (like many bio-inert columns). For the installation of bio-inert ZDV unions, see Installation of the Bio-inert Zero Dead Volume (ZDV) Union on page 11. First installation of a capillary to a soft connector 1 When tightening a fitting for the first time, start from the finger-tight position (which does not necessarily need to be a vertical wrench position) and rotate the wrench by 180 210. Staying below 180 (grey arrow) will not be sufficiently tight, more than 210 (red arrow) could damage the capillary. 9

Second and subsequent installations of a capillary to a soft connector 1 When tightening the fitting for the second and subsequent times, again start from the finger-tight position (which is not necessarily a vertical wrench position) and rotate the wrench by 135 180. Staying below 135 (grey arrow) could be insufficiently tight enough, more than 180 (red arrow) could damage the capillary. 10

Installation of the Bio-inert Zero Dead Volume (ZDV) Union The Bio-inert ZDV (p/n 5067-4741) union has two different connectors where capillaries need to be installed in the correct sequence. Otherwise, an inset of the union may be damaged and the connection may not be tight. CAUTION Potential leak or damage of the Bio-inert ZDV Union. To avoid leaks or a damage to the Bio-inert ZDV union, follow the procedure below in the prescribed sequence. 1 Install the capillary at the end marked with a ring/indentation. 2 Install the second capillary at the other end. 11

*G7116-90130* *G7116-90130* G7116-90130 Part Number: G7116-90130 Edition: 08/2017 Printed in Germany Agilent Technologies, Inc 2017 Agilent Technologies, Inc Hewlett-Packard-Strasse 8 76337 Waldbronn, Germany