PRODUCT INFORMATION. Solar DHW storage tank SKL. Technical description. High performance solar tank, bivalent

Similar documents
PRODUCT INFORMATION. Technical description. Hygienic stratification storage tank HSK ÖKO Universal heat center for legionella safe preparation of DHW

Storage systems. Solarbayer. Fire protection insulation ISO B1

PRODUCT INFORMATION. Satellite collector NANOSOL. Solarbayer GmbH (29.14) 1

Storage systems. Warmth for coziness. New: HSK SLS. We develop for your future. System technology made in Bavaria

Flat plate collector SILVERSUN Mounting instruction Please read carefully before installation. Solarbayer GmbH [21.14] Solarbayer GmbH 1

ECOplus Solar Cylinder

Mounting instruction Please read carefully before installation

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

Installation instructions

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

Installation manual Operating instructions

Buffer Tank FWSS 1000 V7-RH

Installation and operating instructions. DK energy storage and DK energy buffer

TERMO Combi Cylinder TECHNICAL INFORMATION

ThermoClean Domestic water heating system with legionella growth prevention through thermal disinfection

DOMESTIC HOT WATER TANK

INDIRECT WATER HEATERS

Domestic Hot Water Tank

STORAGE WATER HEATERS

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

VERTINOX. AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type

Operating Instructions!

ThermoDual Domestic hot water charging system

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems

Pro-Clean Stratified Tank scope of delivery:

In cooperation with. sustainable energy solutions

Heat Accumulation. thermal stores hot water storage tanks. Energy-saving solutions

Akva Vita Instantaneous water heater

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

Technical information Installation instructions. Modul-plus (F21-52) High performance calorifiers

ENAMELED INDIRECT WATER HEATERS

HW 22 District heating substation for indirect heating and domestic hot water systems

CIRCO 6 Solar Circulation Unit

Product news 2018/19. Heat pump system WIKOSOL HPS. Tank for wall boiler WBO TN. Vacuum tube collector WIKOSUN HP 2340 / 1240

sustainable energy solutions

and Installation Instructions The installation instructions for the Unit pressure jet oil burner is included in the pressure jet oil burner pack.

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

REMKO Comfort-WP The versatile heat pump

SBB 300, 400 S & Sbb 300, 400, 600 Plus

INSTALLATION GUIDE. soft duomatik evoline

OPERATING and INSTALLATION MANUAL

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

SUN EQUINOX HEATING SYSTEMS

REMKO HYBRID HEAT PUMPS

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

MASTER VITRO - VITREOUS ENAMELLED STEEL. Models with COILS, production and efficiency! DHW PRODUCTION/STORAGE TANKS

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

Akva Lux VX District heating substation for indirect heating and domestic hot water systems

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15

Technical information for installation and operation

TECHNICAL PROPERTIES OF THE APPLIANCE

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

SECTION DOMESTIC WATER HEATERS

OPERATING AND INSTALLATION MANUAL

ACCUMULATION OF EUROPEAN CLASS

AE PV Heating Element. Screwing in Heating Unit. Installation Manual. Version 01.6

3-way switching valve

Operating and Installation Instructions

Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

WL Instantaneous water heater

OPERATING and INSTALLATION MANUAL

Waste water ejection unit

Wood log boiler HVS. Solarbayer Gasifying wood log boiler. Ecological hea ng with highest comfort! HVS E ECONOMIC HVS LC.

Gas wall system and combination boilers. Why Vaillant? For more technology and experience. atmotec plus turbotec plus atmotec pro turbotec pro

Avensys Avensys FIN EST SLO RUS UAE

Fresh Water Station FWS 20 / FWS 30. Manual. Masterpieces. Art.-Nr.: (V1.0) of Solar Technology

CALORIFIERS (Energy Storage Tanks) for domestic, commercial and industrial applications.

ir-range 8G /03.15 Changes reserved.

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

COMPACT FLAME CONTROLLER CFC 1000

General Terms and Conditions of Connection and Warranty

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

WATER HEATERS FOR CENTRAL UTILITY WATER ENSOL/1

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

INSTALLATION GUIDE. soft duomatik evoline

COMPACT FLAME CONTROLLER CFC 2000

FINO Kältetrockner. Original FINO

WHE 2.24 / WHE 2.24 FF

Heat pumps. Why Vaillant? Because heating your home should be done naturally.

Model: 1100 Float-Controlled Condensate Trap, PN 25

DHW Tanks Indirect Tanks for Domestic Hot Water. New! Single coil tanks with electric element

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

Installation, operating and servicing instructions

ECO HOT WATER Air-water heat pump for domestic hot water with integrated solar panels and remote control via App GB 02. Ecoenergy.

ROTEX Sanicube / HybridCube High-efficiency hot water storage tank

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

User instructions DHP-AT

WATER HEATERS EN - flyer 03/z/2018 Made in Poland

General Terms and Conditions of Connection and Warranty

english language Product catalogue 09/18 Storage tanks are our element

Installation and instruction manual SOLAR STATION

SECTION ELECTRIC WATER HEATERS

SECTION ELECTRIC WATER HEATERS

Transcription:

We develop for your future PRODUCT INFORMATION High performance solar tank, bivalent Technical description Solarbayer GmbH (50.14) Solarbayer GmbH 1

Content Safety regulations........................................................................... 3 Brief description............................................................................ 4 Description of connections................................................................... 5 Technical specifications...................................................................... 6 Technical specifications, dimensions........................................................... 7 Installation / general information.............................................................. 8 Connection example....................................................................... 10 Insulation................................................................................ 11 Trouble shooting.......................................................................... 11 Abbildungen und Zeichnungen in dieser Produktinformation dienen lediglich der Information und ersetzen nicht die fachtechnische Planung. Aufgrund technischer Änderungen, Satz und Druckfehler kann keine Haftung für die inhaltliche Richtigkeit übernommen werden. 2 Solarbayer GmbH Solarbayer GmbH (50.14)

Sicherheitshinweise / Vorschriften Please read the manual carefully to prevent damages due to improper installation. The installation has to be carried out by a specialized company in accordance with the generally accepted codes of practice as well as with the valid regulations and norms. Country specific regulations have to be regarded. Non professional installation as well as other than the intended use will lead to the expiration of warranty. The following engineering rules have to be regarded: TrinkwV Drinking water regulation 1 DVGW guideline W 551/April 2004 (German Technical and Scientific Association for Gas and Water) Systems for heating up drinking water and drinking water pipelines; technical arrangements for decreasing the legionella growth; planning, isntallation,operation and renovation of DHW installations DIN 1988 Codes of practice for drinking water systems 2 DIN 4751 Safety requirements for heating installations DIN 4753 Water heaters and water heating installations for drinking water and service water; requirements, marking, equipment and testing DIN EN 12975 Thermal solar systems and components DIN 4807 Expansion vessels DIN EN 12828 Heating systems in buildings Design for water based heating systems DIN 18380 Systems for heating and central water heating DIN 18381 Gas, water and sewage plumbing works inside of buildings VDI 2035 Prevention of damage in water heating installations DIN 18382 Electric Cable and Wiring Systems Inside Buildings VDE 0100 Erection of power installations VDE 0105 Operation of electrical installations VDE 0190 Potential equalizing of electrical installations 1 The installation of a DHW storage tank with a capacity from 400 liter and higher has in multi family houses heating systems has to be announced at the responsible Health Office (TrinkwV). Before the installation it has to be checked if the Health Office is already informed. ²Before the installation it has to be tested if the DHW installation, especially the connection to the public water supply, is carried out in accordance with DIN 1988 and if the, stated in part 8, prescribed maintenance had taken place. The operability of security relevant units (e.g. pressure regulator) has to be checked in any case. Solarbayer GmbH (50.14) Solarbayer GmbH 3

Brief description The solar DHW tank SKL is used either in solar systems just for the preparation of domestic hot water or in multi tank sytems in combination with buffer tanks perfectly aligned to all our solar systems, also suitable for condensing technology bivalent tank, two plain tube heat exchangers high quality steel S235JR internal corrosion protection with double enameling (Made in Germany) magnesia anode insulation for SKL 200 to SKL 500: PU rigid foam (non removable), insulation thickness approx. 50 mm insulation for SKL 750 and SKL 1000: removable flexible foam insulation WLG 0,039, insulation thickness approx. 75 mm silver PVC jacket, fire protection classification: B2 installation of an electric heating elements Corrosion protection The DHW storage is suitable for all water conditions and in every piping system. Corrosion protection is given by the double enameling of the internal tank wall in accordance with DIN 4753 part 3. Additional corresion protection offers the magnesia anode in accordance with DIN 4753 part 6. 4 Solarbayer GmbH Solarbayer GmbH (50.14)

AG AG Product information Description of connections Attention: The heating system has to be filled in accordance with VDI 2035. Pay attention to the BDH information sheet n 8. hot water thermometer heating flow line boiler sensor circulation heating return line solar flow line solar sensor solar return line cold water in accordance with DIN Solarbayer GmbH (50.14) Solarbayer GmbH 5

Technical specifications Solar DHW storage tank SKL 200 300 400 500 750 1000 capacity DHW approx. L 200 300 400 500 750 1000 height with insulation [A] mm 1265 1515 1630 1805 1870 2120 height without insulation [B] mm 1805 2055 tilted height mm 1450 1650 1780 1960 1900 2150 diameter with insulation [C] mm 610 650 700 750 950 950 diameter without insulation [D] mm 790 790 solid foam PU insulation (non removable) mm 50 50 50 50 flexibel foam insulation (removable) mm 75 75 jacket PVC, Farbe Silber max. operating pressure tank bar 10 10 10 10 10 10 max. operating temperature tank C 95 95 95 95 95 95 weight aaprox. kg 92 114 149 173 238 250 max. size of electric heating element (optional) kw 4,5 4,5 4,5 6 9 9 Specifications heat exchanger top 200 300 400 500 750 1000 heating surface heat exchanger m² 0,9 1,4 1,4 1,4 2,5 2,5 capacity heat exchanger L 5,5 6,5 6,5 6,5 15 15 max. operating pressure heat exchanger bar 10 10 10 10 10 10 max. operating temperature heat exchanger C 95 95 95 95 95 95 Specifications output performance 200 300 400 500 750 1000 continuous output 10/45 80/60 (kw) heat exchanger top L/h 340 (20) performance indicator N L at 70/50 WT top N L 2,4 3,1 3,6 4,8 11,6 16,8 continuous output 10/45 80/60 (kw) heat exchanger bottom L/h 480 (28) performance indicator N L at 70/50 both exchangers N L 5,6 7,2 11,4 13,7 26,5 34,2 1020 (41) 1290 (52) 1020 (41) 1570 (64) 1020 (41) 1720 (70) 1850 (75) 1850 (75) 1850 (75) 1850 (75) Specifications heat exchanger bottom 200 300 400 500 750 1000 heating surface heat exchanger m² 0,9 1,8 2,2 2,4 2,5 2,5 capacity heat exchanger L 5,5 8,3 10,5 13,5 15 15 max. operating pressure heat exchanger bar 10 10 10 10 10 10 max. operating temperature heat exchanger C 110 110 110 110 110 110 recommended min. collector surface m² 4 6 8 10 14 17 6 Solarbayer GmbH Solarbayer GmbH (50.14)

Technical specifications, dimensions series: SKL 300 SKL 400 SKL 500 1 2 3 4 5 6 series: SKL 200 SKL 750 SKL 1000 1 2 3 4 5 6 A B 8 7 9 A B 8 7 9 10 11 10 12 13 11 12 13 C D C D Connections with dimensioning 200 300 400 500 750 1000 anode (from SKL 400 on an additional anode in the flange) [1] oben 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ hot water [2] mm 1165 (1 IG) 1345 (¾ IG) 1505 (¾ IG) 1640 (¾ IG) 1590 (1¼ IG) 1840 (1¼ IG) heating flow line [3] mm 995 (1¼ IG) 1245 (1 IG) 1355 (1 IG) 1510 (1 IG) 1440 (1¼ IG) 1440 (1¼ IG) thermometer [4] mm 930 (½ IG) 1200 (½ IG) 1300 (18x2) 1450 (18x2) 1460 (½ IG) 1680 (½ IG) boiler sensor [5] mm 915 (½ IG) 1080 (½ IG) 1125 (½ IG) 1285 (½ IG) 1340 (½ IG) 1340 (½ IG) circulation [6] mm 885 (¾ IG) 985 (¾ IG) 1030 (¾ IG) 1185 (¾ IG) 1235 (1 IG) 1235 (1 IG) heating return line [7] mm 680 (1¼ IG) 885 (1 IG) 935 (1 IG) 1060 (1 IG) 990 (1¼ IG) 990 (1¼ IG) electric heating element [8] mm 630 (1½ IG) 830 (1½ IG) 880 (1½ IG) 1010 (1½ IG) 890 (1½ IG) 890 (1½ IG) solar flow line [9] mm 580 (1¼ IG) 770 (¾ IG) 805 (¾ IG) 885 (¾ IG) 835 (1¼ IG) 835 (1¼ IG) solar sensor [10] mm 475 (½ IG) 400 (½ IG) 420 (½ IG) 370 (½ IG) 685 (½ IG) 685 (½ IG) flange Ø 114 mm (from SKL 400 on with anode) [11] mm 260 400 420 (M8x30) 390 (M8x30) 400 (M8x30) 400 (M8x30) solar return line [12] mm 265 (1¼ IG) 245 (1 AG) 265 (1 AG) 285 (1 AG) 385 (1¼ IG) 385 (1¼ IG) cold water [13] mm 70 (1 IG) 145 (¾ IG) 110 (¾ IG) 165 (¾ IG) 220 (1¼ IG) 220 (1¼ IG) Thermotechnical facts 200 300 400 500 750 1000 rate of heat loss in stagnancy according to DIN EN 12976 or DIN ENV 12977 3 W/K 1,07 1,31 1,54 1,84 1,40 1,62 rate of standby loss ΔT 45 C according DIN 4753 8 kwh/d 1,15 1,41 1,66 1,99 1,52 1,75 Solarbayer GmbH (50.14) Solarbayer GmbH 7

Installation / general information Location The tank hast to be located in a frost protected place. Ice formation inside the system may lead to the tank s destruction. The location has to have the necessary space for maintenance and repair work, as well as sufficient load bearing capacity of the ground! Site clearance for dismounting the tank and for transport has to be ensured permanently. Insulation The insulation has to be mounted before piping begin. Do not get near the insulation with fire, brazing flame, welding torch, etc.; fire hazard! Piping The tank is to be installed in accordance with the piping diagram [chapter: Description of connections]. This diagram is only a mounting proposal and does not replace professional planning. The connection has to be carried out in accordance with DIN.. The minimum diameter of the safety valve has to be DN20 (¾"). Attention has to be paid to possible electro chemical reactions when choosing the installation material (mixed installation)! Galvanzied pipe installations have to be replaced. With DHW temperatures of more than 60 C it is generally recommended to limit the temperature by a mixing valve to 60 C! The connection components have to be aligned to these temperatures or the temperature has to be limited by means of a mixing valve! Operating pressure The permissible operating pressures according to our technical specifications [chapter: technical specifications] have to be observed. Exceeding the permissible operating pressure may lead to leakages and destruction of the tank! Pressure reducing valve The installation of a pressure reducing valve is recommended. If the DHW supply is operated with higher pressure a pressure reducing valve has to be installed. In order to reduce sounds caused by fluxion inside the building the pipeline pressure should be adjusted to approx. 3,5 bar. DHW filter It is highly recommended to install a DHW filter in the cold water pipeline since floating particles may block fittings, etc. and may cause corrosion in the pipes. Safety devices The tank has to be equipped with a non lockable safety valve. Moreover, an expansion vessel has to be installed that is dimensioned according to the tank s capacity. It is to be locked only with a cap valve. An expansion vessel for sanitary water has to be installed for the stainless steel heat exchanger. A safety temperature limiter has to be installed in accordance with heating system regulations for scalding protection means. 8 Solarbayer GmbH Solarbayer GmbH (50.14)

Next to the exhaust line of the safety valve, or even better, on the valve itself, an indication plate has to be installed, saying: : "Water is leaking from the valve s pipe for safety reasons during the heating. Do not close!" Draining/de airing The tank hast to be installed in such a way that it can be drained without demounting it. While draining, hot water might exit and cause injuries. The upper socket is provided for de airing the tank. We do not recommend the use of an automatic bleeder. Immersion heater (optional) The tank can additionally be equipped with an electric heating element. You have to respect the regulations of your local public utility when installing an immersion heater. The electric heating elements have to be insulated. It is only with insulation that the corrosion protection is guaranteed. Electric heating elements with insulation and integrated temperature control and safety temperature limiter are optional available at Solarbayer. If electric heating elements without insulation are used, the tank s warranty expires. Initial operation Connections that are not used have to be sealed professionally with plugs. Thoroughly rinse pipes and tank after mounting, heating system has to filled with treated water according to VDI 2035 and bleeded. The DHW temperature control for tanks with a capacity of 400l and more have to adjusted that they will meet the requirements of the DVGW guidlinew 551/April 2004; Systems for heating up drinking water and drinking water pipelines; technical arrangements for decreasing the legionella growth; planning, isntallation,operation and renovation of DHW installations Maintenance: The protection effect is based on an electro chemical reaction when a magnesia anodes is installed. Its result is the decomposition of the magnesia anode. When the magnesia anode is used up the corrossion protection of the tank is no longer guaranteed! Result: perforation, water emersion. Thus, the anode has to be checked every 2 years and replaced when wasted more than 2/3! In order to exchange the magnesia anode the tank has to be depressurized. Close the cold water outlet, shutt off circulation pump and open any hot water tap in the house. The DHW tank should be drained in regular intervals (e.g. every 2 years) and cleaned. Flange: After demounting the flange the sealing has to be renewed when the flange is re installed. The tightening of the screw nuts is 20 25 Nm. Note for installers: Record the check of the magnesia anode, the pressure test as well as the correct filling of the system in accordance with VDI 2035 and let your customer sign the record. Record the adjustment of the temperature control with tanks from 400 l on in accordance with DVGW guideline W 551 and inform the system owner that changings in the settings might lead to objections of the health office during routine checks of DHW quality. Let your customer sign the adjusted settings and the given isntructions. The initial operation of systems with a tank capacity of 400 l onwords in multi family houses has to be indicated with the local health office since November 1st 2011 (Drinking water regulation). Solarbayer GmbH (50.14) Solarbayer GmbH 9

Connection example This connection diagram is only an installation proposal and does not replace technical planning! Connection example of the hot water circulation with DHW storage tank at high tank temperatures due to heating up with solar system and wood log boiler. cold water connection according to DIN 1988 This connection diagram is only an installation proposal and does not replace technical planning! 10 Solarbayer GmbH Solarbayer GmbH (50.14)

Insulation With the SKL 300 500 the PU insulation is a solid foam one foam to the tank,the PVC jacket is removable From SKL 750 on the PVC jacket as well as the insulation are removable. SKL 300 500 SKL 750 1000 material: solid foam flexible foam thermal conductivity λ: 0,024 (+/ 5% ) W/mK 0,039 (+/ 5% ) W/mK insulation thickness: 50 mm 70 mm fire protection classification: B2 jacket with zipper: PVC foil 0,8 mm + 5 mm flexible foam jacket color: silver Trouble shooting Problem Possible reason Solution Leakage Heating up period too long no/too small loading/unloading of the tank when heat is required (heating circuit) Unwanted tank cooling DHW temperature too low pipe connection is leaking air in the system heating water temperature set too low at the controller scaled heat exchanger surfaces heating controller not set correctly temperature inside the tank too low changeover valve defect or connected wrongly flow rate is too low in heating circuit gravity circulation in solar/heating/circulation circuit pipelines insufficiently insulated tank insufficiently insulated safety temperature limiter set too low heating water temperature too low supplementary heating is too late seal connections tighten connections de air the system adjust controller settings the temperature is set too high for the water hardness when scale occurs set controller anew check heat sources (e.g. performance data) check function de air heating circuit increase pump performance check pipe dimensions, when necessary adjust check/install gravity break insulated pipelines/tank connections mount Solarbayer tank insulation increase temperature at safety temperature limiter (thermostatic DHW mixing valve) position tank sensor correctly increase tank temperature at heating controller check parameter on the heating controller (switch on temperature difference) Solarbayer GmbH (50.14) Solarbayer GmbH 11

We develop for your future System technology made in Bavaria Solarbayer GmbH Preith, Am Dörrenhof 22 85131 Pollenfeld Telefon +49(0)8421/93598 0 Telefax +49(0)8421/93598 29 info@solarbayer.de www.solarbayer.de IStorage systems IFresh water systems IWood log boiler ISolar systems IHeat pumps This manual and the pictures and drawings within are protected by the copyright of SOLARBAYER GmbH. Technical changes and errors reserved. The effective one in each case is the current version on our homepage 1 www.solarbayer.de 1 This translation has been provided for informational purposes only and has no legal force and effect. The German version is the only official, complete and exclusive 12 Solarbayer GmbH Solarbayer GmbH (50.14)